ubi: fix bug creating partitions for non-existent volumes
Subsystems (2)
PATCH v2 1/1 ubi: fix bug creating partitions for non-existent volumes
The part_get_info_ubi() function was incorrectly returning 0 (success) when a UBI volume was not found for a given partition index. This caused the part_create_block_devices() function in blk-uclass.c to continue creating devices for non-existent partitions up to MAX_SEARCH_PARTITIONS
Fix the issue by returning -1 when a volume is not found, signaling to the part_create_block_devices() function that no more valid volumes exist.
Before patch, 128 blk_partition are created:
Class Index Probed Driver Name
-------------------------------------------------
root 0 [ + ] root_driver root_driver
thermal 0 [ ] imx_thermal |-- imx_thermal
simple_bus 0 [ + ] simple_bus |-- soc
mtd 0 [ + ] mxs-nand-dt | |-- nand-controller@1806000 blk 0 [ ] ubi_blk | | `-- [email protected] partition 0 [ ] blk_partition | | |-- [email protected]:1
...
partition 127 [ ] blk_partition | | `-- [email protected]:128
After patch, the expected blk_partition are created:
Class Index Probed Driver Name
-------------------------------------------------
root 0 [ + ] root_driver root_driver
thermal 0 [ ] imx_thermal |-- imx_thermal
simple_bus 0 [ + ] simple_bus |-- soc
mtd 0 [ + ] mxs-nand-dt | |-- nand-controller@1806000 blk 0 [ ] ubi_blk | | `-- [email protected]
partition 0 [ ] blk_partition | | |-- [email protected]:1 partition 1 [ ] blk_partition | | |-- [email protected]:2 partition 2 [ ] blk_partition | | |-- [email protected]:3 partition 3 [ ] blk_partition | | `-- [email protected]:4 simple_bus 1 [ + ] simple_bus | |-- bus@2000000
Changed in v2:
- Change return from -1 to -ENOENT
--- drivers/mtd/ubi/part.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-)
drivers/mtd/ubi/part.c +1 -1
@@ -47,7 +47,7 @@ static int __maybe_unused part_get_info_ubi(*/ vol =ubi_get_volume_by_index (part_idx -1 );if (!vol) -return 0 ; +return -ENOENT ;snprintf (info->name,PART_NAME_LEN , vol->name);
Signature · 1 line
2.43.0
Hello Oskar,
Quoted 41 lines · Oskar Nilsson
The
part_get_info_ubi()function was incorrectly returning 0 (success) when a UBI volume was not found for a given partition index. This caused thepart_create_block_devices()function inblk-uclass.cto continue creating devices for non-existent partitions up toMAX_SEARCH_PARTITIONSFix the issue by returning -1 when a volume is not found, signaling to the
part_create_block_devices()function that no more valid volumes exist.Before patch, 128
blk_partitionare created:
Class Index Probed Driver Name
-------------------------------------------------
root 0 [ + ] root_driverroot_driver
thermal 0 [ ] imx_thermal |--imx_thermal
simple_bus 0 [ + ] simple_bus |-- soc
mtd 0 [ + ] mxs-nand-dt | |-- nand-controller@1806000 blk 0 [ ] ubi_blk | | `-- [email protected] partition 0 [ ] blk_partition | | |-- [email protected]:1
...
partition 127 [ ] blk_partition | | `-- [email protected]:128After patch, the expected
blk_partitionare created:
Class Index Probed Driver Name
-------------------------------------------------
root 0 [ + ] root_driverroot_driver
thermal 0 [ ] imx_thermal |--imx_thermal
simple_bus 0 [ + ] simple_bus |-- soc
mtd 0 [ + ] mxs-nand-dt | |-- nand-controller@1806000 blk 0 [ ] ubi_blk | | `-- [email protected]partition 0 [ ] blk_partition | | |-- [email protected]:1 partition 1 [ ] blk_partition | | |-- [email protected]:2 partition 2 [ ] blk_partition | | |-- [email protected]:3 partition 3 [ ] blk_partition | | `-- [email protected]:4 simple_bus 1 [ + ] simple_bus | |-- bus@2000000Signed-off-by Oskar Nilsson <[email protected]>Cc Kyungmin Park <[email protected]>Cc Heiko Schocher <[email protected]>Cc Alexey Romanov <[email protected]>
Quoted 6 lines
Changed in v2:
- Change return from -1 to-ENOENT--- drivers/mtd/ubi/part.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-)
Thanks!
bye,
Heiko
Signature · 3 lines
DENX Software Engineering GmbH, Managing Director: Erika Unter HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany Phone: +49-8142-66989-52 Fax: +49-8142-66989-80 Email: [email protected]
Hello Oskar,
Quoted 41 lines · Oskar Nilsson
The
part_get_info_ubi()function was incorrectly returning 0 (success) when a UBI volume was not found for a given partition index. This caused thepart_create_block_devices()function inblk-uclass.cto continue creating devices for non-existent partitions up toMAX_SEARCH_PARTITIONSFix the issue by returning -1 when a volume is not found, signaling to the
part_create_block_devices()function that no more valid volumes exist.Before patch, 128
blk_partitionare created:
Class Index Probed Driver Name
-------------------------------------------------
root 0 [ + ] root_driverroot_driver
thermal 0 [ ] imx_thermal |--imx_thermal
simple_bus 0 [ + ] simple_bus |-- soc
mtd 0 [ + ] mxs-nand-dt | |-- nand-controller@1806000 blk 0 [ ] ubi_blk | | `-- [email protected] partition 0 [ ] blk_partition | | |-- [email protected]:1
...
partition 127 [ ] blk_partition | | `-- [email protected]:128After patch, the expected
blk_partitionare created:
Class Index Probed Driver Name
-------------------------------------------------
root 0 [ + ] root_driverroot_driver
thermal 0 [ ] imx_thermal |--imx_thermal
simple_bus 0 [ + ] simple_bus |-- soc
mtd 0 [ + ] mxs-nand-dt | |-- nand-controller@1806000 blk 0 [ ] ubi_blk | | `-- [email protected]partition 0 [ ] blk_partition | | |-- [email protected]:1 partition 1 [ ] blk_partition | | |-- [email protected]:2 partition 2 [ ] blk_partition | | |-- [email protected]:3 partition 3 [ ] blk_partition | | `-- [email protected]:4 simple_bus 1 [ + ] simple_bus | |-- bus@2000000Signed-off-by Oskar Nilsson <[email protected]>Cc Kyungmin Park <[email protected]>Cc Heiko Schocher <[email protected]>Cc Alexey Romanov <[email protected]>
Quoted 6 lines
Changed in v2:
- Change return from -1 to-ENOENT--- drivers/mtd/ubi/part.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-)
Applied to u-boot-ubi master
Thanks!
bye,
Heiko
Signature · 3 lines
DENX Software Engineering GmbH, Managing Director: Erika Unter HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany Phone: +49-8142-66989-52 Fax: +49-8142-66989-80 Email: [email protected]