arm64: dts: ls1088a: add one more thermal zone node
Subsystems (2)
PATCH v6 1/1 arm64: dts: ls1088a: add one more thermal zone node
Ls1088a has 2 thermal sensors, core cluster and SoC platform. Core cluster sensor is used to monitor the temperature of core and SoC platform is for platform. The current dts only support the first sensor.
This patch adds the second sensor node to dts to enable it.
---
v6:
- add cooling device map to cpu0-7 in platform node.
arch/arm64/boot/dts/freescale/fsl-ls1088a.dtsi | 43 +++++++++++++++++++++-- 1 files changed, 39 insertions(+), 4 deletions(-)
arch/arm64/boot/dts/freescale/fsl-ls1088a.dtsi +39 -4
@@ -129,19 +129,19 @@ }; thermal-zones { - cpu_thermal: cpu-thermal { + core-cluster { polling-delay-passive = <1000>; polling-delay = <5000>; thermal-sensors = <&tmu 0>; trips { - cpu_alert: cpu-alert { + core_cluster_alert: core-cluster-alert { temperature = <85000>; hysteresis = <2000>; type = "passive"; }; - cpu_crit: cpu-crit { + core_cluster_crit: core-cluster-crit { temperature = <95000>; hysteresis = <2000>; type = "critical";
@@ -150,7 +150,42 @@ cooling-maps { map0 { - trip = <&cpu_alert>; + trip = <&core_cluster_alert>; + cooling-device = + <&cpu0 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>, + <&cpu1 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>, + <&cpu2 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>, + <&cpu3 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>, + <&cpu4 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>, + <&cpu5 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>, + <&cpu6 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>, + <&cpu7 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>; + }; + }; + }; + + platform { + polling-delay-passive = <1000>; + polling-delay = <5000>; + thermal-sensors = <&tmu 1>; + + trips { + platform_alert: platform-alert { + temperature = <85000>; + hysteresis = <2000>; + type = "passive"; + }; + + platform_crit: platform-crit { + temperature = <95000>; + hysteresis = <2000>; + type = "critical"; + }; + }; + + cooling-maps { + map0 { + trip = <&platform_alert>; cooling-device = <&cpu0 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>, <&cpu1 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
Signature · 1 line
1.7.1
Quoted 9 lines · Yuantian Tang
Ls1088a has 2 thermal sensors, core cluster and SoC platform. Core cluster sensor is used to monitor the temperature of core and SoC platform is for platform. The current dts only support the first sensor.
This patch adds the second sensor node to dts to enable it.Signed-off-by Yuantian Tang <[email protected]>---
v6:
- add cooling device map to cpu0-7 in platform node.
@Daniel, are you fine with this version?
Shawn
Quoted 12 lines
-----Original Message-----
From: Shawn Guo <[email protected]>
Sent: 2019年5月10日 11:14
To: Andy Tang <[email protected]>
Cc: Leo Li <[email protected]>; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]
Subject: [EXT] Re: [PATCH v6] arm64: dts: ls1088a: add one more thermal zone node
Quoted 12 lines
Caution: EXT Email
Quoted 9 lines · Yuantian Tang
Ls1088a has 2 thermal sensors, core cluster and SoC platform. Core cluster sensor is used to monitor the temperature of core and SoC platform is for platform. The current dts only support the first sensor. This patch adds the second sensor node to dts to enable it.
Signed-off-by Yuantian Tang <[email protected]>---
v6:
- add cooling device map to cpu0-7 in platform node.
I like to explain a little. I think it makes sense that multiple thermal zone map to same cooling device. In this way, no matter which thermal zone raises a temp alarm, it can call cooling device to chill out. I also asked cpufreq maintainer about the cooling map issue, he think it would be fine. I have tested and no issue found.
Daniel, what's your thought?
Thanks,
Andy
Quoted 4 lines
@Daniel, are you fine with this version?
Shawn
WARNING: This email was created outside of NXP. DO NOT CLICK links or attachments unless you recognize the sender and know the content is safe.
Quoted 70 lines · Andy Tang
Hi Viresh,
Sorry to bother you. I have a question, hope I can get you help. Here it is:
I want to add multiple "Thermal Zone" support in dts ( driver is ready). The final dts looks like below:
thermal-zones { cpu_thermal: cpu-thermal { polling-delay-passive = <1000>; polling-delay = <5000>; thermal-sensors = <&tmu 0>; trips { ccu_alert: ccu-alert { temperature = <85000>; hysteresis = <2000>; type = "passive"; }; ccu_crit: ccu-crit { temperature = <95000>; hysteresis = <2000>; type = "critical"; cooling-maps { map0 { trip = <&ccu_alert>; cooling-device = <&cpu0 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>, <&cpu1 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>, <&cpu2 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>, <&cpu3 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>, <&cpu4 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>, <&cpu5 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>, <&cpu6 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>, <&cpu7 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>; }; }; }; platform { polling-delay-passive = <1000>; polling-delay = <5000>; thermal-sensors = <&tmu 1>; trips { plt_alert: plt-alert { temperature = <85000>; hysteresis = <2000>; type = "passive"; }; plt_crit: plt-crit { temperature = <95000>; hysteresis = <2000>; type = "critical"; }; }; cooling-maps { map0 { trip = <&plt_alert>; cooling-device = <&cpu0 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>, <&cpu1 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>, <&cpu2 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>, <&cpu3 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>, <&cpu4 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>, <&cpu5 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>, <&cpu6 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>, <&cpu7 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>; } }
Quoted 2 lines
Here we have 2 thermal zones, but both map cpu0-7 as cooling device. I have tested and didn't find any issues. My query is: is it allowed to map same device as "cooling device" to more than one "thermal zone"?
That should be fine IMO.
--
viresh
_______________________________________________
linux-arm-kernel mailing list
[email protected]
http://lists.infradead.org/mailman/listinfo/linux-arm-kernel
Quoted 24 lines · Andy Tang
Quoted 12 lines
-----Original Message-----
From: Shawn Guo <[email protected]>
Sent: 2019年5月10日 11:14
To: Andy Tang <[email protected]>
Cc: Leo Li <[email protected]>; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]
Subject: [EXT] Re: [PATCH v6] arm64: dts: ls1088a: add one more thermal zone nodeQuoted 12 lines
Caution: EXT Email
Quoted 9 lines · Yuantian Tang
Ls1088a has 2 thermal sensors, core cluster and SoC platform. Core cluster sensor is used to monitor the temperature of core and SoC platform is for platform. The current dts only support the first sensor. This patch adds the second sensor node to dts to enable it.
Signed-off-by Yuantian Tang <[email protected]>---
v6:
- add cooling device map to cpu0-7 in platform node.
Quoted 6 lines
I like to explain a little. I think it makes sense that multiple thermal zone map to same cooling device. In this way, no matter which thermal zone raises a temp alarm, it can call cooling device to chill out. I also asked cpufreq maintainer about the cooling map issue, he think it would be fine. I have tested and no issue found.
Daniel, what's your thought?
If there are multiple thermal zones, they will be managed by different instances of a thermal governor. Each instances will act on the shared cooling device and will collide in their decisions:
- If the sensors are closed, their behavior will be similar regarding
the temperature. The governors may take the same decision for the cooling device. But in such case having just one thermal zone managed is enough.
- If the sensors are not closed, their behavior will be different
regarding the temperature. The governors will take different decision regarding the cooling device (one will decrease the freq, other will increase the freq).
As the thermal governors are not able to manage several thermal zones and there is one cooling device (the cpu cooling device), this setup won't work as expected IMO.
The setup making sense is having a thermal zone per 'cluster' and a cooling device per 'cluster'. That means the platform has one clock line per 'cluster'. The thermal management happens in a self-contained thermal zone (one cooling device - one governor - one thermal zone).
In the case of HMP, other combinations are possible to be optimal.
Signature · 5 lines
<http://www.linaro.org/> Linaro.org │ Open source software for ARM SoCs Follow Linaro: <http://www.facebook.com/pages/Linaro> Facebook | <http://twitter.com/#!/linaroorg> Twitter | <http://www.linaro.org/linaro-blog/> Blog
+ Viresh for help.
Quoted 64 lines
-----Original Message-----
From: Daniel Lezcano <[email protected]>
Sent: 2019年5月10日 15:17
To: Andy Tang <[email protected]>; Shawn Guo <[email protected]>
Cc: Leo Li <[email protected]>; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]
Subject: Re: [EXT] Re: [PATCH v6] arm64: dts: ls1088a: add one more thermal zone nodeCaution: EXT Email
Quoted 20 lines · Andy Tang
Quoted 20 lines
-----Original Message-----
From: Shawn Guo <[email protected]>
Sent: 2019年5月10日 11:14
To: Andy Tang <[email protected]>
Cc: Leo Li <[email protected]>; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]
Subject: [EXT] Re: [PATCH v6] arm64: dts: ls1088a: add one more thermal zone nodeCaution: EXT Email
Quoted 5 lines · Yuantian Tang
Ls1088a has 2 thermal sensors, core cluster and SoC platform. Core cluster sensor is used to monitor the temperature of core and SoC platform is for platform. The current dts only support the first sensor. This patch adds the second sensor node to dts to enable it.
Quoted 5 lines
Quoted 4 lines
Quoted 4 lines
Signed-off-by Yuantian Tang <[email protected]>---
v6:
- add cooling device map to cpu0-7 in platform node.I like to explain a little. I think it makes sense that multiple thermal zone
map to same cooling device.
Quoted 1 line
In this way, no matter which thermal zone raises a temp alarm, it can call
cooling device to chill out.
Quoted 1 line
I also asked cpufreq maintainer about the cooling map issue, he think it
would be fine.
Quoted 3 lines
I have tested and no issue found.
Daniel, what's your thought?
If there are multiple thermal zones, they will be managed by different instances of a thermal governor. Each instances will act on the shared cooling device and will collide in their decisions:
- If the sensors are closed, their behavior will be similar regarding the
temperature. The governors may take the same decision for the cooling device. But in such case having just one thermal zone managed is enough.- If the sensors are not closed, their behavior will be different regarding the
temperature. The governors will take different decision regarding the cooling device (one will decrease the freq, other will increase the freq).As the thermal governors are not able to manage several thermal zones and there is one cooling device (the cpu cooling device), this setup won't work as expected IMO.
Quoted 6 lines
The setup making sense is having a thermal zone per 'cluster' and a cooling device per 'cluster'. That means the platform has one clock line per 'cluster'. The thermal management happens in a self-contained thermal zone (one cooling device - one governor - one thermal zone).
In the case of HMP, other combinations are possible to be optimal.
Hi Viresh,
I want to map multiple thermal zones to the same cooling device. The above is the discussion about it. It seems reasonable. But I am not expert on this. Could you please provide some thoughts? Thanks.
BR,
Andy
Quoted 29 lines
--
<https://eur01.safelinks.protection.outlook.com/?url=http%3A%2F%2Fwww.
linaro.org%2F&data=02%7C01%7Candy.tang%40nxp.com%7C935b7a08 31cc466da40808d6d5176f8e%7C686ea1d3bc2b4c6fa92cd99c5c301635%7C0 %7C0%7C636930693965540189&sdata=WK9NDBVwzhCC9WMkmjLObJ OBQwRG%2Fboed%2FKx18xiBNQ%3D&reserved=0> Linaro.org │ Open source software for ARM SoCsFollow Linaro:
<https://eur01.safelinks.protection.outlook.com/?url=http%3A%2F%2Fwww.
facebook.com%2Fpages%2FLinaro&data=02%7C01%7Candy.tang%40nx p.com%7C935b7a0831cc466da40808d6d5176f8e%7C686ea1d3bc2b4c6fa92c d99c5c301635%7C0%7C0%7C636930693965550202&sdata=O0mWO76 9sK2ZMGX9AxgLGYNVfkFHBD4ZIGCclttvyPI%3D&reserved=0> Facebook |
<https://eur01.safelinks.protection.outlook.com/?url=http%3A%2F%2Ftwitte
r.com%2F%23!%2Flinaroorg&data=02%7C01%7Candy.tang%40nxp.com %7C935b7a0831cc466da40808d6d5176f8e%7C686ea1d3bc2b4c6fa92cd99c5 c301635%7C0%7C0%7C636930693965550202&sdata=tV%2Bi8Bk3OqO h%2FZHpBr2NQDACVvtGi8KNGQt5dZaTeyg%3D&reserved=0> Twitter |
<https://eur01.safelinks.protection.outlook.com/?url=http%3A%2F%2Fwww.
linaro.org%2Flinaro-blog%2F&data=02%7C01%7Candy.tang%40nxp.co m%7C935b7a0831cc466da40808d6d5176f8e%7C686ea1d3bc2b4c6fa92cd99 c5c301635%7C0%7C0%7C636930693965550202&sdata=0E8a938xEt7l2 MBLnMETsCQKfhJMgmzFNtuCKPXf5SY%3D&reserved=0> Blog
Quoted 46 lines · Andy Tang
+ Viresh for help.
Quoted 44 lines
-----Original Message-----
From: Daniel Lezcano <[email protected]>
Sent: 2019年5月10日 15:17
To: Andy Tang <[email protected]>; Shawn Guo <[email protected]>
Cc: Leo Li <[email protected]>; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]
Subject: Re: [EXT] Re: [PATCH v6] arm64: dts: ls1088a: add one more thermal zone nodeCaution: EXT Email
Quoted 20 lines · Andy Tang
Quoted 20 lines
-----Original Message-----
From: Shawn Guo <[email protected]>
Sent: 2019年5月10日 11:14
To: Andy Tang <[email protected]>
Cc: Leo Li <[email protected]>; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]
Subject: [EXT] Re: [PATCH v6] arm64: dts: ls1088a: add one more thermal zone nodeCaution: EXT Email
Quoted 5 lines · Yuantian Tang
Ls1088a has 2 thermal sensors, core cluster and SoC platform. Core cluster sensor is used to monitor the temperature of core and SoC platform is for platform. The current dts only support the first sensor. This patch adds the second sensor node to dts to enable it.
Quoted 5 lines
Quoted 4 lines
Quoted 4 lines
Signed-off-by Yuantian Tang <[email protected]>---
v6:
- add cooling device map to cpu0-7 in platform node.I like to explain a little. I think it makes sense that multiple thermal zone
map to same cooling device.
Quoted 1 line
In this way, no matter which thermal zone raises a temp alarm, it can call
cooling device to chill out.
Quoted 1 line
I also asked cpufreq maintainer about the cooling map issue, he think it
would be fine.
Yes, you asked me and I said it should be okay.
Quoted 20 lines
Quoted 20 lines
Quoted 3 lines
I have tested and no issue found.
Daniel, what's your thought?
If there are multiple thermal zones, they will be managed by different instances of a thermal governor. Each instances will act on the shared cooling device and will collide in their decisions:
- If the sensors are closed, their behavior will be similar regarding the
temperature. The governors may take the same decision for the cooling device. But in such case having just one thermal zone managed is enough.- If the sensors are not closed, their behavior will be different regarding the
temperature. The governors will take different decision regarding the cooling device (one will decrease the freq, other will increase the freq).As the thermal governors are not able to manage several thermal zones and there is one cooling device (the cpu cooling device), this setup won't work as expected IMO.
Quoted 6 lines
Quoted 6 lines
The setup making sense is having a thermal zone per 'cluster' and a cooling device per 'cluster'. That means the platform has one clock line per 'cluster'. The thermal management happens in a self-contained thermal zone (one cooling device - one governor - one thermal zone).
In the case of HMP, other combinations are possible to be optimal.
But not sure how I missed the obvious, though I do remember thinking about this.
So the problem is that the cpu_cooling driver will get requests in parallel to set different max frequencies and the last call will always win and may result in undesired outcome.
Sorry about creating the confusion.
Signature · 6 lines
viresh _______________________________________________ linux-arm-kernel mailing list [email protected] http://lists.infradead.org/mailman/listinfo/linux-arm-kernel
Thanks Viresh for your explanation.
BR,
Andy
Quoted 110 lines
-----Original Message-----
From: Viresh Kumar <[email protected]>
Sent: 2019年5月10日 18:12
To: Andy Tang <[email protected]>
Cc: Daniel Lezcano <[email protected]>; Shawn Guo <[email protected]>; Leo Li <[email protected]>; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]
Subject: Re: [EXT] Re: [PATCH v6] arm64: dts: ls1088a: add one more thermal zone nodeCaution: EXT Email
Quoted 6 lines · Andy Tang
+ Viresh for help.
Quoted 4 lines
-----Original Message-----
From: Daniel Lezcano <[email protected]>
Sent: 2019年5月10日 15:17
To: Andy Tang <[email protected]>; Shawn GuoQuoted 22 lines
Quoted 22 lines
Cc: Leo Li <[email protected]>; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]
Subject: Re: [EXT] Re: [PATCH v6] arm64: dts: ls1088a: add one more thermal zone nodeCaution: EXT Email
Quoted 12 lines · Andy Tang
Quoted 12 lines
-----Original Message-----
From: Shawn Guo <[email protected]>
Sent: 2019年5月10日 11:14
To: Andy Tang <[email protected]>
Cc: Leo Li <[email protected]>; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]
Subject: [EXT] Re: [PATCH v6] arm64: dts: ls1088a: add one more thermal zone nodeQuoted 6 lines
Quoted 6 lines
Quoted 6 lines
Quoted 6 lines
Caution: EXT Email
Quoted 3 lines · Yuantian Tang
Ls1088a has 2 thermal sensors, core cluster and SoC platform. Core cluster sensor is used to monitor the temperature of core and SoC platform is for platform. The current dts only support the first
sensor.
Quoted 8 lines
Quoted 8 lines
Quoted 8 lines
Quoted 6 lines
Quoted 6 lines
This patch adds the second sensor node to dts to enable it.
Signed-off-by Yuantian Tang <[email protected]>---
v6:
- add cooling device map to cpu0-7 in platform node.I like to explain a little. I think it makes sense that multiple thermal zone
Quoted 7 lines
Quoted 7 lines
map to same cooling device.
Quoted 2 lines
In this way, no matter which thermal zone raises a temp alarm, it can call
cooling device to chill out.
Quoted 2 lines
I also asked cpufreq maintainer about the cooling map issue, he think it
would be fine.
Yes, you asked me and I said it should be okay.
Quoted 11 lines
Quoted 11 lines
Quoted 3 lines
I have tested and no issue found.
Daniel, what's your thought?
If there are multiple thermal zones, they will be managed by different instances of a thermal governor. Each instances will act on the shared cooling device and will collide in their decisions:
- If the sensors are closed, their behavior will be similar
regarding the temperature. The governors may take the same decision for the cooling device. But in such case having just one thermal zonemanaged is enough.
Quoted 4 lines
Quoted 4 lines
- If the sensors are not closed, their behavior will be different
regarding the temperature. The governors will take different decision regarding the cooling device (one will decrease the freq, otherwill increase the freq).
Quoted 7 lines
Quoted 7 lines
As the thermal governors are not able to manage several thermal zones and there is one cooling device (the cpu cooling device), this setup won't work as expected IMO.
The setup making sense is having a thermal zone per 'cluster' and a cooling device per 'cluster'. That means the platform has one clock line
per 'cluster'.
Quoted 4 lines
Quoted 4 lines
The thermal management happens in a self-contained thermal zone (one cooling device - one governor - one thermal zone).
In the case of HMP, other combinations are possible to be optimal.
But not sure how I missed the obvious, though I do remember thinking about this.
So the problem is that the
cpu_coolingdriver will get requests in parallel to set different max frequencies and the last call will always win and may result in undesired outcome.Sorry about creating the confusion.
--
viresh