Skip to contentSkip to conversation

arm64: dts: ls1088a: add one more thermal zone node

PATCH In review Yuantian Tang 4 participants 7 messages Apr 23, 2019 – May 11, 2019

Subsystems (2)
lore
Share & tools
lore
#0 lore raw

PATCH v6 1/1 arm64: dts: ls1088a: add one more thermal zone node

Ls1088a has 2 thermal sensors, core cluster and SoC platform. Core cluster sensor is used to monitor the temperature of core and SoC platform is for platform. The current dts only support the first sensor.
This patch adds the second sensor node to dts to enable it.

---
v6:
- add cooling device map to cpu0-7 in platform node.

 arch/arm64/boot/dts/freescale/fsl-ls1088a.dtsi |   43 +++++++++++++++++++++--
 1 files changed, 39 insertions(+), 4 deletions(-)
arch/arm64/boot/dts/freescale/fsl-ls1088a.dtsi +39 -4
index 661137f..a697a82 100644
@@ -129,19 +129,19 @@
 	};
 
 	thermal-zones {
-		cpu_thermal: cpu-thermal {
+		core-cluster {
 			polling-delay-passive = <1000>;
 			polling-delay = <5000>;
 			thermal-sensors = <&tmu 0>;
 
 			trips {
-				cpu_alert: cpu-alert {
+				core_cluster_alert: core-cluster-alert {
 					temperature = <85000>;
 					hysteresis = <2000>;
 					type = "passive";
 				};
 
-				cpu_crit: cpu-crit {
+				core_cluster_crit: core-cluster-crit {
 					temperature = <95000>;
 					hysteresis = <2000>;
 					type = "critical";
@@ -150,7 +150,42 @@
 
 			cooling-maps {
 				map0 {
-					trip = <&cpu_alert>;
+					trip = <&core_cluster_alert>;
+					cooling-device =
+						<&cpu0 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
+						<&cpu1 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
+						<&cpu2 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
+						<&cpu3 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
+						<&cpu4 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
+						<&cpu5 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
+						<&cpu6 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
+						<&cpu7 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>;
+				};
+			};
+		};
+
+		platform {
+			polling-delay-passive = <1000>;
+			polling-delay = <5000>;
+			thermal-sensors = <&tmu 1>;
+
+			trips {
+				platform_alert: platform-alert {
+					temperature = <85000>;
+					hysteresis = <2000>;
+					type = "passive";
+				};
+
+				platform_crit: platform-crit {
+					temperature = <95000>;
+					hysteresis = <2000>;
+					type = "critical";
+				};
+			};
+
+			cooling-maps {
+				map0 {
+					trip = <&platform_alert>;
 					cooling-device =
 						<&cpu0 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
 						<&cpu1 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
Signature · 1 line
1.7.1
#1 lore raw
Quoted 9 lines · Yuantian Tang

Ls1088a has 2 thermal sensors, core cluster and SoC platform. Core cluster sensor is used to monitor the temperature of core and SoC platform is for platform. The current dts only support the first sensor.
This patch adds the second sensor node to dts to enable it.

---
v6:
- add cooling device map to cpu0-7 in platform node.

@Daniel, are you fine with this version?

Shawn

author
#2 lore raw
Quoted 12 lines

-----Original Message-----
From: Shawn Guo <[email protected]>
Sent: 2019年5月10日 11:14
To: Andy Tang <[email protected]>
Cc: Leo Li <[email protected]>; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]
Subject: [EXT] Re: [PATCH v6] arm64: dts: ls1088a: add one more thermal zone node

Quoted 12 lines

Caution: EXT Email

Quoted 9 lines · Yuantian Tang

Ls1088a has 2 thermal sensors, core cluster and SoC platform. Core cluster sensor is used to monitor the temperature of core and SoC platform is for platform. The current dts only support the first sensor. This patch adds the second sensor node to dts to enable it.

---
v6:
- add cooling device map to cpu0-7 in platform node.

I like to explain a little. I think it makes sense that multiple thermal zone map to same cooling device. In this way, no matter which thermal zone raises a temp alarm, it can call cooling device to chill out. I also asked cpufreq maintainer about the cooling map issue, he think it would be fine. I have tested and no issue found.

Daniel, what's your thought?

Thanks,
Andy

Quoted 4 lines

@Daniel, are you fine with this version?

Shawn

WARNING: This email was created outside of NXP. DO NOT CLICK links or attachments unless you recognize the sender and know the content is safe.

Quoted 70 lines · Andy Tang

Hi Viresh,

Sorry to bother you. I have a question, hope I can get you help. Here it is:

I want to add multiple "Thermal Zone" support in dts ( driver is ready). The final dts looks like below:

        thermal-zones {
                cpu_thermal: cpu-thermal {
                        polling-delay-passive = <1000>;
                        polling-delay = <5000>;
                        thermal-sensors = <&tmu 0>;

                        trips {
                                ccu_alert: ccu-alert {
                                        temperature = <85000>;
                                        hysteresis = <2000>;
                                        type = "passive";
                                };
                                ccu_crit: ccu-crit {
                                        temperature = <95000>;
                                        hysteresis = <2000>;
                                        type = "critical";
                        cooling-maps {
                                map0 {
                                        trip = <&ccu_alert>;
                                        cooling-device =
                                                <&cpu0 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
                                                <&cpu1 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
                                                <&cpu2 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
                                                <&cpu3 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
                                                <&cpu4 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
                                                <&cpu5 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
                                                <&cpu6 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
                                                <&cpu7 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>;
                                };
                        };
                };
                platform {
                        polling-delay-passive = <1000>;
                        polling-delay = <5000>;
                        thermal-sensors = <&tmu 1>;
                        trips {
                                plt_alert: plt-alert {
                                        temperature = <85000>;
                                        hysteresis = <2000>;
                                        type = "passive";
                        };
                                plt_crit: plt-crit {
                                        temperature = <95000>;
                                        hysteresis = <2000>;
                                        type = "critical";
                                };
                        };
                        cooling-maps {
                                map0 {
                                        trip = <&plt_alert>;
                                        cooling-device =
                                                <&cpu0 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
                                                <&cpu1 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
                                                <&cpu2 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
                                                <&cpu3 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
                                                <&cpu4 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
                                                <&cpu5 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
                                                <&cpu6 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
                                                <&cpu7 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>;
                        }
}
Quoted 2 lines

Here we have 2 thermal zones, but both map cpu0-7 as cooling device. I have tested and didn't find any issues. My query is: is it allowed to map same device as "cooling device" to more than one "thermal zone"?

That should be fine IMO.

--
viresh

_______________________________________________
linux-arm-kernel mailing list
[email protected]
http://lists.infradead.org/mailman/listinfo/linux-arm-kernel

#3 lore raw
Quoted 24 lines · Andy Tang
Quoted 12 lines

-----Original Message-----
From: Shawn Guo <[email protected]>
Sent: 2019年5月10日 11:14
To: Andy Tang <[email protected]>
Cc: Leo Li <[email protected]>; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]
Subject: [EXT] Re: [PATCH v6] arm64: dts: ls1088a: add one more thermal zone node

Quoted 12 lines

Caution: EXT Email

Quoted 9 lines · Yuantian Tang

Ls1088a has 2 thermal sensors, core cluster and SoC platform. Core cluster sensor is used to monitor the temperature of core and SoC platform is for platform. The current dts only support the first sensor. This patch adds the second sensor node to dts to enable it.

---
v6:
- add cooling device map to cpu0-7 in platform node.

Quoted 6 lines

I like to explain a little. I think it makes sense that multiple thermal zone map to same cooling device. In this way, no matter which thermal zone raises a temp alarm, it can call cooling device to chill out. I also asked cpufreq maintainer about the cooling map issue, he think it would be fine. I have tested and no issue found.

Daniel, what's your thought?

If there are multiple thermal zones, they will be managed by different instances of a thermal governor. Each instances will act on the shared cooling device and will collide in their decisions:

- If the sensors are closed, their behavior will be similar regarding
the temperature. The governors may take the same decision for the cooling device. But in such case having just one thermal zone managed is enough.

- If the sensors are not closed, their behavior will be different
regarding the temperature. The governors will take different decision regarding the cooling device (one will decrease the freq, other will increase the freq).

As the thermal governors are not able to manage several thermal zones and there is one cooling device (the cpu cooling device), this setup won't work as expected IMO.

The setup making sense is having a thermal zone per 'cluster' and a cooling device per 'cluster'. That means the platform has one clock line per 'cluster'. The thermal management happens in a self-contained thermal zone (one cooling device - one governor - one thermal zone).

In the case of HMP, other combinations are possible to be optimal.

Signature · 5 lines
 <http://www.linaro.org/> Linaro.org │ Open source software for ARM SoCs

Follow Linaro:  <http://www.facebook.com/pages/Linaro> Facebook |
<http://twitter.com/#!/linaroorg> Twitter |
<http://www.linaro.org/linaro-blog/> Blog
author
#4 lore raw

+ Viresh for help.

Quoted 64 lines

-----Original Message-----
From: Daniel Lezcano <[email protected]>
Sent: 2019年5月10日 15:17
To: Andy Tang <[email protected]>; Shawn Guo <[email protected]>
Cc: Leo Li <[email protected]>; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]
Subject: Re: [EXT] Re: [PATCH v6] arm64: dts: ls1088a: add one more thermal zone node

Caution: EXT Email

Quoted 20 lines · Andy Tang
Quoted 20 lines

-----Original Message-----
From: Shawn Guo <[email protected]>
Sent: 2019年5月10日 11:14
To: Andy Tang <[email protected]>
Cc: Leo Li <[email protected]>; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]
Subject: [EXT] Re: [PATCH v6] arm64: dts: ls1088a: add one more thermal zone node

Caution: EXT Email

Quoted 5 lines · Yuantian Tang

Ls1088a has 2 thermal sensors, core cluster and SoC platform. Core cluster sensor is used to monitor the temperature of core and SoC platform is for platform. The current dts only support the first sensor. This patch adds the second sensor node to dts to enable it.

Quoted 5 lines
Quoted 4 lines
Quoted 4 lines

---
v6:
- add cooling device map to cpu0-7 in platform node.

I like to explain a little. I think it makes sense that multiple thermal zone

map to same cooling device.

Quoted 1 line

In this way, no matter which thermal zone raises a temp alarm, it can call

cooling device to chill out.

Quoted 1 line

I also asked cpufreq maintainer about the cooling map issue, he think it

would be fine.

Quoted 3 lines

I have tested and no issue found.

Daniel, what's your thought?

If there are multiple thermal zones, they will be managed by different instances of a thermal governor. Each instances will act on the shared cooling device and will collide in their decisions:

- If the sensors are closed, their behavior will be similar regarding the
temperature. The governors may take the same decision for the cooling device. But in such case having just one thermal zone managed is enough.

- If the sensors are not closed, their behavior will be different regarding the
temperature. The governors will take different decision regarding the cooling device (one will decrease the freq, other will increase the freq).

As the thermal governors are not able to manage several thermal zones and there is one cooling device (the cpu cooling device), this setup won't work as expected IMO.

Quoted 6 lines

The setup making sense is having a thermal zone per 'cluster' and a cooling device per 'cluster'. That means the platform has one clock line per 'cluster'. The thermal management happens in a self-contained thermal zone (one cooling device - one governor - one thermal zone).

In the case of HMP, other combinations are possible to be optimal.

Hi Viresh,

I want to map multiple thermal zones to the same cooling device. The above is the discussion about it. It seems reasonable. But I am not expert on this. Could you please provide some thoughts? Thanks.

BR,
Andy

Quoted 29 lines

--

<https://eur01.safelinks.protection.outlook.com/?url=http%3A%2F%2Fwww.
linaro.org%2F&amp;data=02%7C01%7Candy.tang%40nxp.com%7C935b7a08 31cc466da40808d6d5176f8e%7C686ea1d3bc2b4c6fa92cd99c5c301635%7C0 %7C0%7C636930693965540189&amp;sdata=WK9NDBVwzhCC9WMkmjLObJ OBQwRG%2Fboed%2FKx18xiBNQ%3D&amp;reserved=0> Linaro.org │ Open source software for ARM SoCs

Follow Linaro:
<https://eur01.safelinks.protection.outlook.com/?url=http%3A%2F%2Fwww.
facebook.com%2Fpages%2FLinaro&amp;data=02%7C01%7Candy.tang%40nx p.com%7C935b7a0831cc466da40808d6d5176f8e%7C686ea1d3bc2b4c6fa92c d99c5c301635%7C0%7C0%7C636930693965550202&amp;sdata=O0mWO76 9sK2ZMGX9AxgLGYNVfkFHBD4ZIGCclttvyPI%3D&amp;reserved=0> Facebook |
<https://eur01.safelinks.protection.outlook.com/?url=http%3A%2F%2Ftwitte
r.com%2F%23!%2Flinaroorg&amp;data=02%7C01%7Candy.tang%40nxp.com %7C935b7a0831cc466da40808d6d5176f8e%7C686ea1d3bc2b4c6fa92cd99c5 c301635%7C0%7C0%7C636930693965550202&amp;sdata=tV%2Bi8Bk3OqO h%2FZHpBr2NQDACVvtGi8KNGQt5dZaTeyg%3D&amp;reserved=0> Twitter |
<https://eur01.safelinks.protection.outlook.com/?url=http%3A%2F%2Fwww.
linaro.org%2Flinaro-blog%2F&amp;data=02%7C01%7Candy.tang%40nxp.co m%7C935b7a0831cc466da40808d6d5176f8e%7C686ea1d3bc2b4c6fa92cd99 c5c301635%7C0%7C0%7C636930693965550202&amp;sdata=0E8a938xEt7l2 MBLnMETsCQKfhJMgmzFNtuCKPXf5SY%3D&amp;reserved=0> Blog

#5 lore raw
Quoted 46 lines · Andy Tang

+ Viresh for help.

Quoted 44 lines

-----Original Message-----
From: Daniel Lezcano <[email protected]>
Sent: 2019年5月10日 15:17
To: Andy Tang <[email protected]>; Shawn Guo <[email protected]>
Cc: Leo Li <[email protected]>; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]
Subject: Re: [EXT] Re: [PATCH v6] arm64: dts: ls1088a: add one more thermal zone node

Caution: EXT Email

Quoted 20 lines · Andy Tang
Quoted 20 lines

-----Original Message-----
From: Shawn Guo <[email protected]>
Sent: 2019年5月10日 11:14
To: Andy Tang <[email protected]>
Cc: Leo Li <[email protected]>; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]
Subject: [EXT] Re: [PATCH v6] arm64: dts: ls1088a: add one more thermal zone node

Caution: EXT Email

Quoted 5 lines · Yuantian Tang

Ls1088a has 2 thermal sensors, core cluster and SoC platform. Core cluster sensor is used to monitor the temperature of core and SoC platform is for platform. The current dts only support the first sensor. This patch adds the second sensor node to dts to enable it.

Quoted 5 lines
Quoted 4 lines
Quoted 4 lines

---
v6:
- add cooling device map to cpu0-7 in platform node.

I like to explain a little. I think it makes sense that multiple thermal zone

map to same cooling device.

Quoted 1 line

In this way, no matter which thermal zone raises a temp alarm, it can call

cooling device to chill out.

Quoted 1 line

I also asked cpufreq maintainer about the cooling map issue, he think it

would be fine.

Yes, you asked me and I said it should be okay.

Quoted 20 lines
Quoted 20 lines
Quoted 3 lines

I have tested and no issue found.

Daniel, what's your thought?

If there are multiple thermal zones, they will be managed by different instances of a thermal governor. Each instances will act on the shared cooling device and will collide in their decisions:

- If the sensors are closed, their behavior will be similar regarding the
temperature. The governors may take the same decision for the cooling device. But in such case having just one thermal zone managed is enough.

- If the sensors are not closed, their behavior will be different regarding the
temperature. The governors will take different decision regarding the cooling device (one will decrease the freq, other will increase the freq).

As the thermal governors are not able to manage several thermal zones and there is one cooling device (the cpu cooling device), this setup won't work as expected IMO.

Quoted 6 lines
Quoted 6 lines

The setup making sense is having a thermal zone per 'cluster' and a cooling device per 'cluster'. That means the platform has one clock line per 'cluster'. The thermal management happens in a self-contained thermal zone (one cooling device - one governor - one thermal zone).

In the case of HMP, other combinations are possible to be optimal.

But not sure how I missed the obvious, though I do remember thinking about this.

So the problem is that the cpu_cooling driver will get requests in parallel to set different max frequencies and the last call will always win and may result in undesired outcome.

Sorry about creating the confusion.

Signature · 6 lines
viresh

_______________________________________________
linux-arm-kernel mailing list
[email protected]
http://lists.infradead.org/mailman/listinfo/linux-arm-kernel
author
#6 lore raw

Thanks Viresh for your explanation.

BR,
Andy

Quoted 110 lines

-----Original Message-----
From: Viresh Kumar <[email protected]>
Sent: 2019年5月10日 18:12
To: Andy Tang <[email protected]>
Cc: Daniel Lezcano <[email protected]>; Shawn Guo <[email protected]>; Leo Li <[email protected]>; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]
Subject: Re: [EXT] Re: [PATCH v6] arm64: dts: ls1088a: add one more thermal zone node

Caution: EXT Email

Quoted 6 lines · Andy Tang

+ Viresh for help.

Quoted 4 lines

-----Original Message-----
From: Daniel Lezcano <[email protected]>
Sent: 2019年5月10日 15:17
To: Andy Tang <[email protected]>; Shawn Guo

<[email protected]>

Quoted 22 lines
Quoted 22 lines

Cc: Leo Li <[email protected]>; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]
Subject: Re: [EXT] Re: [PATCH v6] arm64: dts: ls1088a: add one more thermal zone node

Caution: EXT Email

Quoted 12 lines · Andy Tang
Quoted 12 lines

-----Original Message-----
From: Shawn Guo <[email protected]>
Sent: 2019年5月10日 11:14
To: Andy Tang <[email protected]>
Cc: Leo Li <[email protected]>; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]
Subject: [EXT] Re: [PATCH v6] arm64: dts: ls1088a: add one more thermal zone node

Quoted 6 lines
Quoted 6 lines
Quoted 6 lines
Quoted 6 lines

Caution: EXT Email

Quoted 3 lines · Yuantian Tang

Ls1088a has 2 thermal sensors, core cluster and SoC platform. Core cluster sensor is used to monitor the temperature of core and SoC platform is for platform. The current dts only support the first

sensor.

Quoted 8 lines
Quoted 8 lines
Quoted 8 lines
Quoted 6 lines
Quoted 6 lines

This patch adds the second sensor node to dts to enable it.

---
v6:
- add cooling device map to cpu0-7 in platform node.

I like to explain a little. I think it makes sense that multiple thermal zone

Quoted 7 lines
Quoted 7 lines

map to same cooling device.

Quoted 2 lines

In this way, no matter which thermal zone raises a temp alarm, it can call

cooling device to chill out.

Quoted 2 lines

I also asked cpufreq maintainer about the cooling map issue, he think it

would be fine.

Yes, you asked me and I said it should be okay.

Quoted 11 lines
Quoted 11 lines
Quoted 3 lines

I have tested and no issue found.

Daniel, what's your thought?

If there are multiple thermal zones, they will be managed by different instances of a thermal governor. Each instances will act on the shared cooling device and will collide in their decisions:

- If the sensors are closed, their behavior will be similar
regarding the temperature. The governors may take the same decision for the cooling device. But in such case having just one thermal zone

managed is enough.

Quoted 4 lines
Quoted 4 lines

- If the sensors are not closed, their behavior will be different
regarding the temperature. The governors will take different decision regarding the cooling device (one will decrease the freq, other

will increase the freq).

Quoted 7 lines
Quoted 7 lines

As the thermal governors are not able to manage several thermal zones and there is one cooling device (the cpu cooling device), this setup won't work as expected IMO.

The setup making sense is having a thermal zone per 'cluster' and a cooling device per 'cluster'. That means the platform has one clock line

per 'cluster'.

Quoted 4 lines
Quoted 4 lines

The thermal management happens in a self-contained thermal zone (one cooling device - one governor - one thermal zone).

In the case of HMP, other combinations are possible to be optimal.

But not sure how I missed the obvious, though I do remember thinking about this.

So the problem is that the cpu_cooling driver will get requests in parallel to set different max frequencies and the last call will always win and may result in undesired outcome.

Sorry about creating the confusion.

--
viresh