formal/spinhint: Clarify the proof
PATCH 1/1 formal/spinhint: Clarify the proof
The third step and the fourth step seem to have no causal relationship between them. Therefore, this patch explains under what circumstances both counters will be at least 1.
--- formal/spinhint.tex | 5 +++-- 1 file changed, 3 insertions(+), 2 deletions(-)
formal/spinhint.tex +3 -2
@@ -1103,8 +1103,9 @@ follows: execution. \item The counter corresponding to this reader will have been at least 1 during this time interval. -\item The \co{synchronize_qrcu()} code forces at least one - of the counters to be at least 1 at all times. +\item If the counter corresponding to this reader is 1, then + the other counter is at least 1 because of the completion of + counter flip. \item Therefore, at any given point in time, either one of the counters will be at least 2, or both of the counters will be at least one.
Signature · 1 line
2.34.1
Hi Alan,
Quoted 1 line · Alan Huang
The third step and the fourth step seem to have no causal relationship between them.
Why do you expect causal relationship between the two?
Quoted 13 lines
Therefore, this patch explains under what circumstances both counters will be at least 1.
Signed-off-by Alan Huang <[email protected]>--- formal/spinhint.tex | 5 +++-- 1 file changed, 3 insertions(+), 2 deletions(-)formal/spinhint.tex +0
-0@@ -1103,8 +1103,9 @@ follows: execution.
formal/spinhint.tex follows: · line 1111
Quoted 10 lines
formal/spinhint.tex +3
-2\item The counter corresponding to this reader will have been at least 1 during this time interval. -\item The \co{synchronize_qrcu()} code forces at least one - of the counters to be at least 1 at all times. +\item If the counter corresponding to this reader is 1, then + the other counter is at least 1 because of the completion of + counter flip. \item Therefore, at any given point in time, either one of the counters will be at least 2, or both of the counters will be at least one.
"Therefore" on item 4 looks to me assumes all of items 1, 2, and 3.
What am I missing?
Thanks, Akira
Hi Akira,
Quoted 26 lines
2023年5月16日 下午6:07,Akira Yokosawa <[email protected]> 写道:
Hi Alan,
Quoted 1 line · Alan Huang
The third step and the fourth step seem to have no causal relationship between them.
Why do you expect causal relationship between the two?
Quoted 17 lines
Therefore, this patch explains under what circumstances both counters will be at least 1.
Signed-off-by Alan Huang <[email protected]>---
formal/spinhint.tex | 5 +++--1 file changed, 3 insertions(+), 2 deletions(-)formal/spinhint.tex +0
-0@@ -1103,8 +1103,9 @@ follows: execution.\item The counter corresponding to this reader will have been
at least 1 during this time interval.
-\item The \co{synchronize_qrcu()} code forces at least oneformal/spinhint.tex +0
-1- of the counters to be at least 1 at all times.
Quoted 8 lines
Quoted 6 lines
+\item If the counter corresponding to this reader is 1, then
formal/spinhint.tex +2
-0+ the other counter is at least 1 because of the completion of + counter flip.\item Therefore, at any given point in time, either one of the
counters will be at least 2, or both of the counters will be at least one."Therefore" on item 4 looks to me assumes all of items 1, 2, and 3.
Yeah, that’s right. My commit message is misleading.
This patch makes item 3 more specific.
Thanks,
Alan
Quoted 4 lines
What am I missing?
Thanks, Akira
Hi Alan,
Quoted 37 lines · Alan Huang
Hi Akira,
Quoted 26 lines
2023年5月16日 下午6:07,Akira Yokosawa <[email protected]> 写道:
Hi Alan,
Quoted 1 line · Alan Huang
The third step and the fourth step seem to have no causal relationship between them.
Why do you expect causal relationship between the two?
Quoted 17 lines
Therefore, this patch explains under what circumstances both counters will be at least 1.
Signed-off-by Alan Huang <[email protected]>---
formal/spinhint.tex | 5 +++--1 file changed, 3 insertions(+), 2 deletions(-)formal/spinhint.tex +0
-0@@ -1103,8 +1103,9 @@ follows: execution.\item The counter corresponding to this reader will have been
at least 1 during this time interval.
-\item The \co{synchronize_qrcu()} code forces at least oneformal/spinhint.tex +0
-1- of the counters to be at least 1 at all times.Quoted 8 lines
Quoted 6 lines
+\item If the counter corresponding to this reader is 1, then
formal/spinhint.tex +2
-0+ the other counter is at least 1 because of the completion of + counter flip.\item Therefore, at any given point in time, either one of the
counters will be at least 2, or both of the counters will be at least one."Therefore" on item 4 looks to me assumes all of items 1, 2, and 3.
Quoted 3 lines
Yeah, that’s right. My commit message is misleading.
This patch makes item 3 more specific.
I might be too nit-picky, but you are changing the simple statement of observation:
The synchronize_qrcu() code forces at least one of the counters to be at least 1 at all times.
to a complex sentence of:
If the counter corresponding to this reader is 1, then the other counter is at least 1 because of the completion of counter flip.
Your wording describes something different from the original one, doesn't it?
Can you elaborate what you find hard to follow in this _informal_ proof?
Thanks, Akira
Quoted 9 lines
Thanks,
AlanQuoted 4 lines
What am I missing?
Thanks, Akira
Hi Akira,
Quoted 58 lines
2023年5月17日 下午10:55,Akira Yokosawa <[email protected]> 写道:
Hi Alan,
Quoted 37 lines · Alan Huang
Hi Akira,
Quoted 26 lines
2023年5月16日 下午6:07,Akira Yokosawa <[email protected]> 写道:
Hi Alan,
Quoted 1 line · Alan Huang
The third step and the fourth step seem to have no causal relationship between them.
Why do you expect causal relationship between the two?
Quoted 17 lines
Therefore, this patch explains under what circumstances both counters will be at least 1.
Signed-off-by Alan Huang <[email protected]>---
formal/spinhint.tex | 5 +++--1 file changed, 3 insertions(+), 2 deletions(-)formal/spinhint.tex +0
-0@@ -1103,8 +1103,9 @@ follows: execution.\item The counter corresponding to this reader will have been
at least 1 during this time interval.
-\item The \co{synchronize_qrcu()} code forces at least oneformal/spinhint.tex +0
-1- of the counters to be at least 1 at all times.Quoted 8 lines
Quoted 6 lines
+\item If the counter corresponding to this reader is 1, then
formal/spinhint.tex +2
-0+ the other counter is at least 1 because of the completion of + counter flip.\item Therefore, at any given point in time, either one of the
counters will be at least 2, or both of the counters will be at least one."Therefore" on item 4 looks to me assumes all of items 1, 2, and 3.
Quoted 3 lines
Yeah, that’s right. My commit message is misleading.
This patch makes item 3 more specific.
I might be too nit-picky, but you are changing the simple statement of observation:
The
synchronize_qrcu()code forces at least one of the counters to be at least 1 at all times.to a complex sentence of:
If the counter corresponding to this reader is 1, then the other counter is at least 1 because of the completion of counter flip.
Quoted 5 lines
Your wording describes something different from the original one, doesn't it?
Can you elaborate what you find hard to follow in this _informal_ proof?
Item 4 says:
Therefore, at any given point in time, either one of the counters will be at least 2, or both of the counters will be at least one.
“at least 2” is obvious, but it took me some time to figure this out:
"or both of the counters will be at least one”
The original item 3 is not very helpful to me.
But others may prefer the original one :)
Thanks,
Alan
Quoted 10 lines
Thanks, Akira
Quoted 8 lines
Thanks,
AlanQuoted 4 lines
What am I missing?
Thanks, Akira
Quoted 72 lines · Alan Huang
Hi Akira,
Quoted 58 lines
2023年5月17日 下午10:55,Akira Yokosawa <[email protected]> 写道:
Hi Alan,
Quoted 37 lines · Alan Huang
Hi Akira,
Quoted 26 lines
2023年5月16日 下午6:07,Akira Yokosawa <[email protected]> 写道:
Hi Alan,
Quoted 1 line · Alan Huang
The third step and the fourth step seem to have no causal relationship between them.
Why do you expect causal relationship between the two?
Quoted 17 lines
Therefore, this patch explains under what circumstances both counters will be at least 1.
Signed-off-by Alan Huang <[email protected]>---
formal/spinhint.tex | 5 +++--1 file changed, 3 insertions(+), 2 deletions(-)formal/spinhint.tex +0
-0@@ -1103,8 +1103,9 @@ follows: execution.\item The counter corresponding to this reader will have been
at least 1 during this time interval.
-\item The \co{synchronize_qrcu()} code forces at least oneformal/spinhint.tex +0
-1- of the counters to be at least 1 at all times.Quoted 8 lines
Quoted 6 lines
+\item If the counter corresponding to this reader is 1, then
formal/spinhint.tex +2
-0+ the other counter is at least 1 because of the completion of + counter flip.\item Therefore, at any given point in time, either one of the
counters will be at least 2, or both of the counters will be at least one."Therefore" on item 4 looks to me assumes all of items 1, 2, and 3.
Quoted 3 lines
Yeah, that’s right. My commit message is misleading.
This patch makes item 3 more specific.
I might be too nit-picky, but you are changing the simple statement of observation:
The
synchronize_qrcu()code forces at least one of the counters to be at least 1 at all times.to a complex sentence of:
If the counter corresponding to this reader is 1, then the other counter is at least 1 because of the completion of counter flip.
Quoted 5 lines
Your wording describes something different from the original one, doesn't it?
Can you elaborate what you find hard to follow in this _informal_ proof?
Item 4 says:
Therefore, at any given point in time, either one of the counters will be at least 2, or both of the counters will be at least one.
Quoted 7 lines
“at least 2” is obvious, but it took me some time to figure this out:
"or both of the counters will be at least one”
The original item 3 is not very helpful to me.
But others may prefer the original one :)
I will take a closer look before the end of the weekend. Sorry to be slow, but a Linux-kernel RCU issue has me by the ankle.
Thanx, Paul
Quoted 13 lines · Alan Huang
The third step and the fourth step seem to have no causal relationship between them. Therefore, this patch explains under what circumstances both counters will be at least 1.
Signed-off-by Alan Huang <[email protected]>--- formal/spinhint.tex | 5 +++-- 1 file changed, 3 insertions(+), 2 deletions(-)formal/spinhint.tex +0
-0
formal/spinhint.tex follows: · line 1107
Quoted 5 lines
formal/spinhint.tex +0
-2@@ -1103,8 +1103,9 @@ follows: execution. \item The counter corresponding to this reader will have been at least 1 during this time interval. -\item The \co{synchronize_qrcu()} code forces at least one - of the counters to be at least 1 at all times.
So this part is true and fundamental to understanding the code. You can see this on lines 31-33 of Listing 12.14 ("QRCU Updater Process"). This code increments the next counter before decrementing the previous counter. I therefore don't see how we can reasonably delete this item.
formal/spinhint.tex follows: · line 1108
Quoted 3 lines
formal/spinhint.tex +3
-0+\item If the counter corresponding to this reader is 1, then + the other counter is at least 1 because of the completion of + counter flip.
However, we could potentially add this as an intermediate consequence of items 2 and 3. Maybe something like this?
\item The above two items imply that if the counter corresponding
to this reader is exactly one, then the other counter must be greater than or equal to one. Similarly, if the other counter is equal to zero, then the counter corresponding to the reader must be greater than or equal to two.
formal/spinhint.tex follows: · line 1111
Quoted 3 lines
formal/spinhint.tex +0
-0\item Therefore, at any given point in time, either one of the counters will be at least 2, or both of the counters will be at least one.
Would that help, or am I missing your point?
Thanx, Paul
Quoted 12 lines
2023年5月21日 18:20,Paul E. McKenney <[email protected]> 写道:
Quoted 8 lines · Alan Huang
The third step and the fourth step seem to have no causal relationship between them. Therefore, this patch explains under what circumstances both counters will be at least 1.
Signed-off-by Alan Huang <[email protected]>---
formal/spinhint.tex | 5 +++--1 file changed, 3 insertions(+), 2 deletions(-)
Quoted 15 lines
Quoted 10 lines
formal/spinhint.tex +0
-0@@ -1103,8 +1103,9 @@ follows:execution.
\item The counter corresponding to this reader will have been at least 1 during this time interval.
-\item The \co{synchronize_qrcu()} code forces at least one
- of the counters to be at least 1 at all times.So this part is true and fundamental to understanding the code. You can see this on lines 31-33 of Listing 12.14 ("QRCU Updater Process"). This code increments the next counter before decrementing the previous counter. I therefore don't see how we can reasonably delete this item.
Yes, this item is completely correct.
Quoted 5 lines
Quoted 4 lines
+\item If the counter corresponding to this reader is 1, then
+ the other counter is at least 1 because of the completion of
+ counter flip.
Quoted 8 lines
However, we could potentially add this as an intermediate consequence of items 2 and 3. Maybe something like this?
\item The above two items imply that if the counter corresponding to this reader is exactly one, then the other counter must be greater than or equal to one. Similarly, if the other counter is equal to zero, then the counter corresponding to the reader must be greater than or equal to two.
That will be very helpful, adding an item will be better than deleting one!
Thanks,
Alan
Quoted 8 lines
Quoted 4 lines
\item Therefore, at any given point in time, either one of the counters will be at least 2, or both of the counters will be at least one.
Would that help, or am I missing your point?
Thanx, Paul
Quoted 38 lines · Alan Huang
Quoted 12 lines
2023年5月21日 18:20,Paul E. McKenney <[email protected]> 写道:
Quoted 8 lines · Alan Huang
The third step and the fourth step seem to have no causal relationship between them. Therefore, this patch explains under what circumstances both counters will be at least 1.
Signed-off-by Alan Huang <[email protected]>---
formal/spinhint.tex | 5 +++--1 file changed, 3 insertions(+), 2 deletions(-)Quoted 15 lines
Quoted 10 lines
formal/spinhint.tex +0
-0@@ -1103,8 +1103,9 @@ follows:execution.
\item The counter corresponding to this reader will have been at least 1 during this time interval.
-\item The \co{synchronize_qrcu()} code forces at least one
- of the counters to be at least 1 at all times.So this part is true and fundamental to understanding the code. You can see this on lines 31-33 of Listing 12.14 ("QRCU Updater Process"). This code increments the next counter before decrementing the previous counter. I therefore don't see how we can reasonably delete this item.
Yes, this item is completely correct.
Quoted 8 lines
Quoted 4 lines
+\item If the counter corresponding to this reader is 1, then
+ the other counter is at least 1 because of the completion of
+ counter flip.However, we could potentially add this as an intermediate consequence of items 2 and 3. Maybe something like this?
Quoted 7 lines
Quoted 5 lines
\item The above two items imply that if the counter corresponding to this reader is exactly one, then the other counter must be greater than or equal to one. Similarly, if the other counter is equal to zero, then the counter corresponding to the reader must be greater than or equal to two.
That will be very helpful, adding an item will be better than deleting one!
Very good, thank you! I have added the following, with your Reported-by.
Thanx, Paul
------------------------------------------------------------------------
commit cbef7a09aa845ca2eded65a124970c6508d4b2b2
Author: Paul E. McKenney <[email protected]> Date: Sat May 27 03:35:55 2023 -0700
spinhint: Add clarifying step to QRCU by-hand proof
formal/spinhint.tex +5 -0
@@ -1105,6 +1105,11 @@ follows: at least 1 during this time interval. \item The \co{synchronize_qrcu()} code forces at least one of the counters to be at least 1 at all times. +\item The above two items imply that if the counter corresponding + to this reader is exactly one, then the other counter must be + greater than or equal to one. + Similarly, if the other counter is equal to zero, then the counter + corresponding to the reader must be greater than or equal to two. \item Therefore, at any given point in time, either one of the counters will be at least 2, or both of the counters will be at least one.