Applied "regulator: max8973: add DT binding details for junction warn temp" to the regulator tree
Subsystems (2)
Mark Brown
maintainerThe patch
regulator: max8973: add DT binding details for junction warn temp
has been applied to the regulator tree at
git://git.kernel.org/pub/scm/linux/kernel/git/broonie/regulator.git
All being well this means that it will be integrated into the linux-next tree (usually sometime in the next 24 hours) and sent to Linus during the next merge window (or sooner if it is a bug fix), however if problems are discovered then the patch may be dropped or reverted.
You may get further e-mails resulting from automated or manual testing and review of the tree, please engage with people reporting problems and send followup patches addressing any issues that are reported if needed.
If any updates are required or you are submitting further changes they should be sent as incremental updates against current git, existing patches will not be replaced.
Please add any relevant lists and maintainers to the CCs when replying to this mail.
Thanks,
Mark
Quoted 1 line
From
3c0ff151c56eb47792f39da2454c400f55fc005bMon Sep 17 00:00:00 2001
From: Laxman Dewangan <[email protected]>
Date: Fri, 4 Mar 2016 15:57:53 +0530
Subject: [PATCH] regulator: max8973: add DT binding details for junction warn
temp
The driver MAX8973 supports the driver for Maxim MAX77621. MAX77621 supports the junction temp warning at 120 degC and 140 degC which is configurable. It generates alert signal when junction temperature crosses these threshold.
Add DT properties and its binding details to make this configuration from DT.
--- Documentation/devicetree/bindings/regulator/max8973-regulator.txt | 7 +++++++ 1 file changed, 7 insertions(+)
Documentation/devicetree/bindings/regulator/max8973-regulator.txt +7 -0
@@ -32,6 +32,13 @@ Optional properties: Enhanced transient response (ETR) will affect the configuration of CKADV. +-junction-warn-millicelsius: u32, junction warning temperature threshold + in millicelsius. If die temperature crosses this level then + device generates the warning interrupts. + +Please note that thermal functionality is only supported on MAX77621. The +supported threshold warning temperature for MAX77621 are 120 degC and 140 degC. + Example: max8973@1b {
Signature · 1 line
2.7.0