preventing chassis power-on until bmc Ready
Greetings,
We at IBM have been finding cases where we wrote our services in a way that they assume the BMC has reached "Ready" state prior to a chassis power on and host firmware boot being allowed to start. For example, to power on the chassis, you need to have collected all of the vpd associated with the VRM's and power supplies. This vpd collection occurs on the way to BMC Ready, and services in the power on target assume it's all been collected. We have other scenarios like this and we're wondering if we continue to whack-a-mole by fixing these individually with explicit service dependencies or do something a bit more global to ensure our systems aren't allowed to power on until the BMC has reached the "Ready" state. This state ensures all inventory and other system data has been collected and created on d-bus.
The BMC reaches the "Ready" state once all services within the multi-user.target have successfully started running.
I know in the past I've heard of servers that allow both the BMC and Host to boot in parallel (which sounds awesome) but we're not there yet. I'm contemplating an optional package in phosphor-state-manager that could be installed and put in the [email protected] and prevent any other services running until the BMC reached Ready.
The [email protected] does have a "After=multi-user.target" within it but that doesn't control the services within the poweron target. It just ensures systemd will not consider the [email protected] complete until multi-user.target has completed.
Anyone else have a similar issue and/or thoughts on this problem?
Thanks,
Andrew
I don't really like using multi-user.target to order host startup because we may have lots of optional or non-critical services that take a long time to become ready that just end up delaying the boot time of the server (which is a critical amount of time to reduce for our usecase). I can also see how different platforms probably have different definitions of "critical" components based on what the bootup firmware ends up querying the BMC for. But having some kind of unit we can opt-in to ordering services against may be useful as we have our own targets for this purpose on google BMCs.
Quoted 33 lines · Andrew Geissler
Greetings,
We at IBM have been finding cases where we wrote our services in a way that they assume the BMC has reached "Ready" state prior to a chassis power on and host firmware boot being allowed to start. For example, to power on the chassis, you need to have collected all of the vpd associated with the VRM's and power supplies. This vpd collection occurs on the way to BMC Ready, and services in the power on target assume it's all been collected. We have other scenarios like this and we're wondering if we continue to whack-a-mole by fixing these individually with explicit service dependencies or do something a bit more global to ensure our systems aren't allowed to power on until the BMC has reached the "Ready" state. This state ensures all inventory and other system data has been collected and created on d-bus.
The BMC reaches the "Ready" state once all services within the multi-user.target have successfully started running.
I know in the past I've heard of servers that allow both the BMC and Host to boot in parallel (which sounds awesome) but we're not there yet. I'm contemplating an optional package in phosphor-state-manager that could be installed and put in the [email protected] and prevent any other services running until the BMC reached Ready.
The [email protected] does have a "After=multi-user.target" within it but that doesn't control the services within the poweron target. It just ensures systemd will not consider the [email protected] complete until multi-user.target has completed.
Anyone else have a similar issue and/or thoughts on this problem?
Thanks,
Andrew
Quoted 9 lines · William Kennington
I don't really like using multi-user.target to order host startup because we may have lots of optional or non-critical services that take a long time to become ready that just end up delaying the boot time of the server (which is a critical amount of time to reduce for our usecase).
Yep, I agree, if you only have a few critical services needed to boot, waiting on multi-user.target is very inefficient.
Quoted 5 lines
I can also see how different platforms probably have different definitions of "critical" components based on what the bootup firmware ends up querying the BMC for. But having some kind of unit we can opt-in to ordering services against may be useful as we have our own targets for this purpose on google BMCs.
Yeah, I like this. An optional opt-in unit that systems owners can put their services against.
I took a first stab at a design up at:
https://gerrit.openbmc-project.xyz/c/openbmc/docs/+/53723
Quoted 35 lines · Andrew Geissler
Quoted 33 lines
Greetings,
We at IBM have been finding cases where we wrote our services in a way that they assume the BMC has reached "Ready" state prior to a chassis power on and host firmware boot being allowed to start. For example, to power on the chassis, you need to have collected all of the vpd associated with the VRM's and power supplies. This vpd collection occurs on the way to BMC Ready, and services in the power on target assume it's all been collected. We have other scenarios like this and we're wondering if we continue to whack-a-mole by fixing these individually with explicit service dependencies or do something a bit more global to ensure our systems aren't allowed to power on until the BMC has reached the "Ready" state. This state ensures all inventory and other system data has been collected and created on d-bus.
The BMC reaches the "Ready" state once all services within the multi-user.target have successfully started running.
I know in the past I've heard of servers that allow both the BMC and Host to boot in parallel (which sounds awesome) but we're not there yet. I'm contemplating an optional package in phosphor-state-manager that could be installed and put in the [email protected] and prevent any other services running until the BMC reached Ready.
The [email protected] does have a "After=multi-user.target" within it but that doesn't control the services within the poweron target. It just ensures systemd will not consider the [email protected] complete until multi-user.target has completed.
Anyone else have a similar issue and/or thoughts on this problem?
Thanks,
Andrew
Quoted 3 lines · Andrew Geissler
I know in the past I've heard of servers that allow both the BMC and Host to boot in parallel (which sounds awesome) but we're not there yet.
That would really be awesome... server boot times have become ridiculous, with the time amount of Black Screen (BMC boot time I think) time seeming to be increasing...
I think that Dell had to tweak some things a decade ago when people started putting multiple hundred Gb of ram in; I have old servers that take 10+ minutes to POST.
I do wonder if, as you say, the whack-a-mole should continue, or if the host should just be able to inquire (and wait) for the BMC to finish booting. So, don't prevent the host from booting, but allow the host to synchronize with the BMC before it continues.
That would be in the BIOS, and perhaps could even be a prototyped as a (host) grub module.
It seems like there is a lot of mechanism in the BMC that affects the host booting. (Like virtual USB bootable media)
It would also be very very annoying if one never could get boot console capture after a cold boot, but only after a warm boot.
--
] Never tell me the odds! | ipv6 mesh networks [ ] Michael Richardson, Sandelman Software Works | network architect [ ] [email protected] http://www.sandelman.ca/ | ruby on rails [