fw and match filters (was NAT+mangle+tc)
Quoted 6 lines · Robert Felber
try:
tc filter add dev eth2 protocol ip parent 1: prio 1 handle 1 fw classid 1:X
X is your class, it should not be 1 since this is usually a root class (I guess you are using HTB). Example:
Ok. I created two special classes under '1:' for each interface to acomodate the icmp traffic.
Now the 'tc filter ... fw ... ' lines works flawlessly.
But after I execute the 'tc filter ... fw ... ' command, every 'tc filter ... match ... ' after those gives me the 'RTNETLINK answers: Invalid argument' error.
Aren't they (fw and match) supposed to cohexist?
If I comment the 2 'filter fw' lines the errors desappear. Any ideas?
Ethy H. Brito /"\
InterNexo Ltda. \ / CAMPANHA DA FITA ASCII - CONTRA MAIL HTML
+55 (12) 3941-6860 X ASCII RIBBON CAMPAIGN - AGAINST HTML MAIL
S.J.Campos - Brasil / \
_______________________________________________
LARTC mailing list / [email protected]
http://mailman.ds9a.nl/mailman/listinfo/lartc HOWTO: http://lartc.org/
Quoted 9 lines · Ethy H. Brito
Ok. I created two special classes under '1:' for each interface to acomodate the icmp traffic.
Now the 'tc filter ... fw ... ' lines works flawlessly.But after I execute the 'tc filter ... fw ... ' command, every 'tc filter ... match ... ' after those gives me the 'RTNETLINK answers: Invalid argument' error.
Aren't they (fw and match) supposed to cohexist?
Hm, no. I have a setup based soley on fw-marks. After adding an u32 match filter i get no RTNETLINK messages:
# tc filter show dev imq0 filter parent 1: protocol ip pref 1 fw filter parent 1: protocol ip pref 1 fw handle 0x1 classid 1:10 filter parent 1: protocol ip pref 2 fw filter parent 1: protocol ip pref 2 fw handle 0x2 classid 1:20 filter parent 1: protocol ip pref 10 u32 filter parent 1: protocol ip pref 10 u32 fh 800: ht divisor 1 filter parent 1: protocol ip pref 10 u32 fh 800::800 order 2048 key ht 800 bkt 0 flowid 1:30 match 312c0404/ffffffff at 12
probably some version bug? I have
# tc -V tc utility, iproute2-ss020116
Signature · 10 lines
Robert Felber (EDV-Leitung) Autohaus Erich Kuttendreier Drosselweg 21 81827 Muenchen Tel: +49 (0) 89 / 453 12-86 Fax: +49 (0) 89 / 453 12-80 PGP: 896CF30B PGP-Fingerprint: CF36 AA93 9716 63E8 962F 15CC A80E 1A79 BF77 25EA