PATCH 1/1 docs/cxl: Fix some typos

Found while reading the doc.

---
 docs/system/devices/cxl.rst | 12 ++++++------
 1 file changed, 6 insertions(+), 6 deletions(-)
docs/system/devices/cxl.rst +6 -6
index abf7c1f24305..891bbd65d9d8 100644
@@ -83,7 +83,7 @@ CXL Fixed Memory Windows (CFMW)
 A CFMW consists of a particular range of Host Physical Address space
 which is routed to particular CXL Host Bridges.  At time of generic
 software initialization it will have a particularly interleaving
-configuration and associated Quality of Serice Throtling Group (QTG).
+configuration and associated Quality of Service Throttling Group (QTG).
 This information is available to system software, when making
 decisions about how to configure interleave across available CXL
 memory devices.  It is provide as CFMW Structures (CFMWS) in
@@ -98,7 +98,7 @@ specification defined register interface called CXL Host Bridge
 Component Registers (CHBCR). The location of this CHBCR MMIO
 space is described to system software via a CXL Host Bridge
 Structure (CHBS) in the CEDT ACPI table.  The actual interfaces
-are identical to those used for other parts of the CXL heirarchy
+are identical to those used for other parts of the CXL hierarchy
 as CXL Component Registers in PCI BARs.
 
 Interfaces provided include:
@@ -111,7 +111,7 @@ Interfaces provided include:
 
 CXL Root Ports (CXL RP)
 ~~~~~~~~~~~~~~~~~~~~~~~
-A CXL Root Port servers te same purpose as a PCIe Root Port.
+A CXL Root Port servers the same purpose as a PCIe Root Port.
 There are a number of CXL specific Designated Vendor Specific
 Extended Capabilities (DVSEC) in PCIe Configuration Space
 and associated component register access via PCI bars.
@@ -143,7 +143,7 @@ CXL Memory Devices - Type 3
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~
 CXL type 3 devices use a PCI class code and are intended to be supported
 by a generic operating system driver. They have HDM decoders
-though in these EP devices, the decoder is reponsible not for
+though in these EP devices, the decoder is responsible not for
 routing but for translation of the incoming host physical address (HPA)
 into a Device Physical Address (DPA).
 
@@ -209,7 +209,7 @@ Notes:
     ranges of the system physical address map.  Each CFMW has
     particular interleave setup across the CXL Host Bridges (HB)
     CFMW0 provides uninterleaved access to HB0, CFW2 provides
-    uninterleaved acess to HB1. CFW1 provides interleaved memory access
+    uninterleaved access to HB1. CFW1 provides interleaved memory access
     across HB0 and HB1.
 
 (2) **Two CXL Host Bridges**. Each of these has 2 CXL Root Ports and
@@ -282,7 +282,7 @@ Example topology involving a switch::
             ---------------------------------------------------
            |    Switch 0  USP as PCI 0d:00.0                   |
            |    USP has HDM decoder which direct traffic to    |
-           |    appropiate downstream port                     |
+           |    appropriate downstream port                    |
            |    Switch BUS appears as 0e                       |
            |x__________________________________________________|
             |                  |               |              |
Signature · 1 line
2.38.0
Reviewed-by on v1 1/1
#1 lore raw
Quoted 3 lines · Davidlohr Bueso

Found while reading the doc.

Quoted 65 lines
---
 docs/system/devices/cxl.rst | 12 ++++++------
 1 file changed, 6 insertions(+), 6 deletions(-)
docs/system/devices/cxl.rst +6 -6
index abf7c1f24305..891bbd65d9d8 100644
@@ -83,7 +83,7 @@ CXL Fixed Memory Windows (CFMW)
 A CFMW consists of a particular range of Host Physical Address space
 which is routed to particular CXL Host Bridges.  At time of generic
 software initialization it will have a particularly interleaving
-configuration and associated Quality of Serice Throtling Group (QTG).
+configuration and associated Quality of Service Throttling Group (QTG).
 This information is available to system software, when making
 decisions about how to configure interleave across available CXL
 memory devices.  It is provide as CFMW Structures (CFMWS) in
@@ -98,7 +98,7 @@ specification defined register interface called CXL Host Bridge
 Component Registers (CHBCR). The location of this CHBCR MMIO
 space is described to system software via a CXL Host Bridge
 Structure (CHBS) in the CEDT ACPI table.  The actual interfaces
-are identical to those used for other parts of the CXL heirarchy
+are identical to those used for other parts of the CXL hierarchy
 as CXL Component Registers in PCI BARs.
 
 Interfaces provided include:
@@ -111,7 +111,7 @@ Interfaces provided include:
 
 CXL Root Ports (CXL RP)
 ~~~~~~~~~~~~~~~~~~~~~~~
-A CXL Root Port servers te same purpose as a PCIe Root Port.
+A CXL Root Port servers the same purpose as a PCIe Root Port.
 There are a number of CXL specific Designated Vendor Specific
 Extended Capabilities (DVSEC) in PCIe Configuration Space
 and associated component register access via PCI bars.
@@ -143,7 +143,7 @@ CXL Memory Devices - Type 3
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~
 CXL type 3 devices use a PCI class code and are intended to be supported
 by a generic operating system driver. They have HDM decoders
-though in these EP devices, the decoder is reponsible not for
+though in these EP devices, the decoder is responsible not for
 routing but for translation of the incoming host physical address (HPA)
 into a Device Physical Address (DPA).
 
@@ -209,7 +209,7 @@ Notes:
     ranges of the system physical address map.  Each CFMW has
     particular interleave setup across the CXL Host Bridges (HB)
     CFMW0 provides uninterleaved access to HB0, CFW2 provides
-    uninterleaved acess to HB1. CFW1 provides interleaved memory access
+    uninterleaved access to HB1. CFW1 provides interleaved memory access
     across HB0 and HB1.
 
 (2) **Two CXL Host Bridges**. Each of these has 2 CXL Root Ports and
@@ -282,7 +282,7 @@ Example topology involving a switch::
             ---------------------------------------------------
            |    Switch 0  USP as PCI 0d:00.0                   |
            |    USP has HDM decoder which direct traffic to    |
-           |    appropiate downstream port                     |
+           |    appropriate downstream port                    |
            |    Switch BUS appears as 0e                       |
            |x__________________________________________________|
             |                  |               |              |
Signature · 1 line
2.38.0
#2 lore raw
In reply to Davidlohr Bueso
Quoted 12 lines · Davidlohr Bueso

Found while reading the doc.

---
 docs/system/devices/cxl.rst | 12 ++++++------
 1 file changed, 6 insertions(+), 6 deletions(-)
docs/system/devices/cxl.rst +0 -0
index abf7c1f24305..891bbd65d9d8 100644

docs/system/devices/cxl.rst CXL Fixed Memory Windows (CFMW) · line 84

Quoted 2 lines
docs/system/devices/cxl.rst +0 -0
@@ -83,7 +83,7 @@ CXL Fixed Memory Windows (CFMW)
 A CFMW consists of a particular range of Host Physical Address space
 which is routed to particular CXL Host Bridges.  At time of generic

to 'a' particular

docs/system/devices/cxl.rst CXL Fixed Memory Windows (CFMW) · line 85

Quoted 1 line
docs/system/devices/cxl.rst +0 -0
 software initialization it will have a particularly interleaving

s/particularly/particular or just remove usage of the entire word here and above. Not sure that 'particular' is particularly helpful here ;)

docs/system/devices/cxl.rst CXL Fixed Memory Windows (CFMW) · line 89

Quoted 5 lines
docs/system/devices/cxl.rst +1 -1
-configuration and associated Quality of Serice Throtling Group (QTG).
+configuration and associated Quality of Service Throttling Group (QTG).
 This information is available to system software, when making
 decisions about how to configure interleave across available CXL
 memory devices.  It is provide as CFMW Structures (CFMWS) in

s/provide/provided

Quoted 10 lines
docs/system/devices/cxl.rst +1 -1
@@ -98,7 +98,7 @@ specification defined register interface called CXL Host Bridge
 Component Registers (CHBCR). The location of this CHBCR MMIO
 space is described to system software via a CXL Host Bridge
 Structure (CHBS) in the CEDT ACPI table.  The actual interfaces
-are identical to those used for other parts of the CXL heirarchy
+are identical to those used for other parts of the CXL hierarchy
 as CXL Component Registers in PCI BARs.
 
 Interfaces provided include:

docs/system/devices/cxl.rst Interfaces provided include: · line 114

Quoted 5 lines
docs/system/devices/cxl.rst +1 -1
@@ -111,7 +111,7 @@ Interfaces provided include:
 
 CXL Root Ports (CXL RP)
 ~~~~~~~~~~~~~~~~~~~~~~~
-A CXL Root Port servers te same purpose as a PCIe Root Port.
+A CXL Root Port servers the same purpose as a PCIe Root Port.

s/servers/serves

docs/system/devices/cxl.rst CXL Memory Devices - Type 3 · line 146

Quoted 9 lines
docs/system/devices/cxl.rst +1 -1
 There are a number of CXL specific Designated Vendor Specific
 Extended Capabilities (DVSEC) in PCIe Configuration Space
 and associated component register access via PCI bars.
@@ -143,7 +143,7 @@ CXL Memory Devices - Type 3
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~
 CXL type 3 devices use a PCI class code and are intended to be supported
 by a generic operating system driver. They have HDM decoders
-though in these EP devices, the decoder is reponsible not for
+though in these EP devices, the decoder is responsible not for

s/"responsible not"/"not responsible"

docs/system/devices/cxl.rst Notes: · line 213

Quoted 10 lines
docs/system/devices/cxl.rst +1 -1
 routing but for translation of the incoming host physical address (HPA)
 into a Device Physical Address (DPA).
 
@@ -209,7 +209,7 @@ Notes:
     ranges of the system physical address map.  Each CFMW has
     particular interleave setup across the CXL Host Bridges (HB)
     CFMW0 provides uninterleaved access to HB0, CFW2 provides
-    uninterleaved acess to HB1. CFW1 provides interleaved memory access
+    uninterleaved access to HB1. CFW1 provides interleaved memory access
     across HB0 and HB1.

s/CFW1/CFMW1 s/CFW2/CFMW2

docs/system/devices/cxl.rst Example topology involving a switch:: · line 285

Quoted 8 lines
docs/system/devices/cxl.rst +1 -1
 (2) **Two CXL Host Bridges**. Each of these has 2 CXL Root Ports and
@@ -282,7 +282,7 @@ Example topology involving a switch::
             ---------------------------------------------------
            |    Switch 0  USP as PCI 0d:00.0                   |
            |    USP has HDM decoder which direct traffic to    |
-           |    appropiate downstream port                     |
+           |    appropriate downstream port                    |

to 'the' or to 'an' approp...

docs/system/devices/cxl.rst Example topology involving a switch:: · line 288

Quoted 3 lines
docs/system/devices/cxl.rst +0 -0
            |    Switch BUS appears as 0e                       |
            |x__________________________________________________|
             |                  |               |              |

OK - after picking at this a bit, and only picking at the pieces I see in this diff, I'll suggest a check back through this section entirely, rather than the piecemeal spelling corrections.