PATCH 1/1 PCI: vmd: Do not disable MSI-X remapping in VMD 28C0 controller

From: Xinghui Li <[email protected]>

Commit ee81ee84f873("PCI: vmd: Disable MSI-X remapping when possible") disable the vmd MSI-X remapping for optimizing pci performance.However, this feature severely negatively optimized performance in multi-disk situations.

In FIO 4K random test, we test 1 disk in the 1 CPU

when disable MSI-X remapping:
read: IOPS=1183k, BW=4622MiB/s (4847MB/s)(1354GiB/300001msec)
READ: bw=4622MiB/s (4847MB/s), 4622MiB/s-4622MiB/s (4847MB/s-4847MB/s), io=1354GiB (1454GB), run=300001-300001msec

When not disable MSI-X remapping:
read: IOPS=1171k, BW=4572MiB/s (4795MB/s)(1340GiB/300001msec)
READ: bw=4572MiB/s (4795MB/s), 4572MiB/s-4572MiB/s (4795MB/s-4795MB/s), io=1340GiB (1438GB), run=300001-300001msec

However, the bypass mode could increase the interrupts costs in CPU. We test 12 disks in the 6 CPU,

When disable MSI-X remapping:
read: IOPS=562k, BW=2197MiB/s (2304MB/s)(644GiB/300001msec)
READ: bw=2197MiB/s (2304MB/s), 2197MiB/s-2197MiB/s (2304MB/s-2304MB/s), io=644GiB (691GB), run=300001-300001msec

When not disable MSI-X remapping:
read: IOPS=1144k, BW=4470MiB/s (4687MB/s)(1310GiB/300005msec)
READ: bw=4470MiB/s (4687MB/s), 4470MiB/s-4470MiB/s (4687MB/s-4687MB/s), io=1310GiB (1406GB), run=300005-300005msec

---
 drivers/pci/controller/vmd.c | 3 +--
 1 file changed, 1 insertion(+), 2 deletions(-)
drivers/pci/controller/vmd.c +1 -2
index e06e9f4fc50f..9f6e9324d67d 100644
@@ -998,8 +998,7 @@ static const struct pci_device_id vmd_ids[] = {
 		.driver_data = VMD_FEAT_HAS_MEMBAR_SHADOW_VSCAP,},
 	{PCI_DEVICE(PCI_VENDOR_ID_INTEL, PCI_DEVICE_ID_INTEL_VMD_28C0),
 		.driver_data = VMD_FEAT_HAS_MEMBAR_SHADOW |
-				VMD_FEAT_HAS_BUS_RESTRICTIONS |
-				VMD_FEAT_CAN_BYPASS_MSI_REMAP,},
+				VMD_FEAT_HAS_BUS_RESTRICTIONS,},
 	{PCI_DEVICE(PCI_VENDOR_ID_INTEL, 0x467f),
 		.driver_data = VMD_FEAT_HAS_MEMBAR_SHADOW_VSCAP |
 				VMD_FEAT_HAS_BUS_RESTRICTIONS |
Signature · 1 line
2.39.0
#1 lore raw
Quoted 14 lines · On 12/22/22 12:26 AM, [email protected] wrote:

From: Xinghui Li <[email protected]>

Commit ee81ee84f873("PCI: vmd: Disable MSI-X remapping when possible") disable the vmd MSI-X remapping for optimizing pci performance.However, this feature severely negatively optimized performance in multi-disk situations.

In FIO 4K random test, we test 1 disk in the 1 CPU

when disable MSI-X remapping:
read: IOPS=1183k, BW=4622MiB/s (4847MB/s)(1354GiB/300001msec)
READ: bw=4622MiB/s (4847MB/s), 4622MiB/s-4622MiB/s (4847MB/s-4847MB/s), io=1354GiB (1454GB), run=300001-300001msec

Quoted 7 lines

When not disable MSI-X remapping:
read: IOPS=1171k, BW=4572MiB/s (4795MB/s)(1340GiB/300001msec)
READ: bw=4572MiB/s (4795MB/s), 4572MiB/s-4572MiB/s (4795MB/s-4795MB/s), io=1340GiB (1438GB), run=300001-300001msec

However, the bypass mode could increase the interrupts costs in CPU. We test 12 disks in the 6 CPU,

Well the bypass mode was made to improve performance where you have >4 drives so this is pretty surprising. With bypass mode disabled, VMD will intercept and forward interrupts, increasing costs.

I think Nirmal would want to to understand if there's some other factor going on here.

Quoted 30 lines

When disable MSI-X remapping:
read: IOPS=562k, BW=2197MiB/s (2304MB/s)(644GiB/300001msec)
READ: bw=2197MiB/s (2304MB/s), 2197MiB/s-2197MiB/s (2304MB/s-2304MB/s), io=644GiB (691GB), run=300001-300001msec

When not disable MSI-X remapping:
read: IOPS=1144k, BW=4470MiB/s (4687MB/s)(1310GiB/300005msec)
READ: bw=4470MiB/s (4687MB/s), 4470MiB/s-4470MiB/s (4687MB/s-4687MB/s), io=1310GiB (1406GB), run=300005-300005msec

---
  drivers/pci/controller/vmd.c | 3 +--
  1 file changed, 1 insertion(+), 2 deletions(-)
drivers/pci/controller/vmd.c +1 -2
index e06e9f4fc50f..9f6e9324d67d 100644
@@ -998,8 +998,7 @@ static const struct pci_device_id vmd_ids[] = {
  		.driver_data = VMD_FEAT_HAS_MEMBAR_SHADOW_VSCAP,},
  	{PCI_DEVICE(PCI_VENDOR_ID_INTEL, PCI_DEVICE_ID_INTEL_VMD_28C0),
  		.driver_data = VMD_FEAT_HAS_MEMBAR_SHADOW |
-				VMD_FEAT_HAS_BUS_RESTRICTIONS |
-				VMD_FEAT_CAN_BYPASS_MSI_REMAP,},
+				VMD_FEAT_HAS_BUS_RESTRICTIONS,},
  	{PCI_DEVICE(PCI_VENDOR_ID_INTEL, 0x467f),
  		.driver_data = VMD_FEAT_HAS_MEMBAR_SHADOW_VSCAP |
  				VMD_FEAT_HAS_BUS_RESTRICTIONS |
#2 lore raw
Quoted 11 lines · Jonathan Derrick
Quoted 3 lines · On 12/22/22 12:26 AM, [email protected] wrote:

However, the bypass mode could increase the interrupts costs in CPU. We test 12 disks in the 6 CPU,

Well the bypass mode was made to improve performance where you have >4 drives so this is pretty surprising. With bypass mode disabled, VMD will intercept and forward interrupts, increasing costs.

I think Nirmal would want to to understand if there's some other factor going on here.

With 12 drives and only 6 CPUs, the bypass mode is going to get more irq context switching. Sounds like the non-bypass mode is aggregating and spreading interrupts across the cores better, but there's probably some cpu:drive count tipping point where performance favors the other way.

The fio jobs could also probably set their cpus_allowed differently to get better performance in the bypass mode.

author
#3 lore raw
Quoted 5 lines · Keith Busch <[email protected]> 于2022年12月23日周五 05:56写道:

With 12 drives and only 6 CPUs, the bypass mode is going to get more irq context switching. Sounds like the non-bypass mode is aggregating and spreading interrupts across the cores better, but there's probably some cpu:drive count tipping point where performance favors the other way.

We found that tunning the interrupt aggregation can also bring the drive performance back to normal.

Quoted 2 lines

The fio jobs could also probably set their cpus_allowed differently to get better performance in the bypass mode.

We used the cpus_allowed in FIO to fix 12 dirves in 6 different CPU.

By the way, sorry for emailing twice, the last one had the format problem.

#4 lore raw
Quoted 10 lines · Xinghui Li
Quoted 5 lines · Keith Busch <[email protected]> 于2022年12月23日周五 05:56写道:

With 12 drives and only 6 CPUs, the bypass mode is going to get more irq context switching. Sounds like the non-bypass mode is aggregating and spreading interrupts across the cores better, but there's probably some cpu:drive count tipping point where performance favors the other way.

We found that tunning the interrupt aggregation can also bring the drive performance back to normal.

Quoted 6 lines
Quoted 2 lines

The fio jobs could also probably set their cpus_allowed differently to get better performance in the bypass mode.

We used the cpus_allowed in FIO to fix 12 dirves in 6 different CPU.

By the way, sorry for emailing twice, the last one had the format problem.

The bypass mode should help in the cases where drives irqs (eg nproc) exceed VMD I/O irqs. VMD I/O irqs for 28c0 should be min(63, nproc). You have very few cpus for a Skylake system with that many drives, unless you mean you are explicitly restricting the 12 drives to only 6 cpus. Either way, bypass mode is effectively VMD-disabled, which points to other issues. Though I have also seen much smaller interrupt aggregation benefits.

author
#5 lore raw
Quoted 7 lines · Jonathan Derrick <[email protected]> 于2022年12月28日周三 06:32写道:

The bypass mode should help in the cases where drives irqs (eg nproc) exceed VMD I/O irqs. VMD I/O irqs for 28c0 should be min(63, nproc). You have very few cpus for a Skylake system with that many drives, unless you mean you are explicitly restricting the 12 drives to only 6 cpus. Either way, bypass mode is effectively VMD-disabled, which points to other issues. Though I have also seen much smaller interrupt aggregation benefits.

Firstly,I am sorry for my words misleading you. We totally tested 12 drives. And each drive run in 6 CPU cores with 8 jobs.

Secondly, I try to test the drives with VMD disabled,I found the results to be largely consistent with bypass mode. I suppose the bypass mode just "bypass" the VMD controller.

The last one,we found in bypass mode the CPU idle is 91%. But in remapping mode the CPU idle is 78%. And the bypass's context-switchs is much fewer than the remapping
mode's. It seems the system is watiing for something in bypass mode.

#6 lore raw

As the bypass mode seems to affect performance greatly depending on the specific configuration, it may make sense to use a moduleparam to control it

I'd vote for it being in VMD mode (non-bypass) by default.

Quoted 20 lines · Xinghui Li
Quoted 7 lines · Jonathan Derrick <[email protected]> 于2022年12月28日周三 06:32写道:

The bypass mode should help in the cases where drives irqs (eg nproc) exceed VMD I/O irqs. VMD I/O irqs for 28c0 should be min(63, nproc). You have very few cpus for a Skylake system with that many drives, unless you mean you are explicitly restricting the 12 drives to only 6 cpus. Either way, bypass mode is effectively VMD-disabled, which points to other issues. Though I have also seen much smaller interrupt aggregation benefits.

Firstly,I am sorry for my words misleading you. We totally tested 12 drives. And each drive run in 6 CPU cores with 8 jobs.

Secondly, I try to test the drives with VMD disabled,I found the results to be largely consistent with bypass mode. I suppose the bypass mode just "bypass" the VMD controller.

The last one,we found in bypass mode the CPU idle is 91%. But in remapping mode the CPU idle is 78%. And the bypass's context-switchs is much fewer than the remapping
mode's. It seems the system is watiing for something in bypass mode.

author
#7 lore raw
Quoted 4 lines · Jonathan Derrick <[email protected]> 于2023年1月10日周二 05:00写道:

As the bypass mode seems to affect performance greatly depending on the specific configuration, it may make sense to use a moduleparam to control it

We found that each pcie port can mount four drives. If we only test 2 or 1 dirve of one pcie port,
the performance of the drive performance will be normal. Also, we observed the interruptions in different modes.
bypass:
.....

2022-12-28-11-39-14: 1224       181665   IR-PCI-MSI 201850948-edge      nvme0q68
2022-12-28-11-39-14: 1179       180115   IR-PCI-MSI 201850945-edge      nvme0q65
2022-12-28-11-39-14:  RES        26743   Rescheduling interrupts

2022-12-28-11-39-17: irqtop - IRQ : 3029, TOTAL : 2100315228, CPU :
192, ACTIVE CPU : 192
disable:
......

2022-12-28-12-05-56: 1714       169797   IR-PCI-MSI 14155850-edge      nvme1q74
2022-12-28-12-05-56: 1701       168753   IR-PCI-MSI 14155849-edge      nvme1q73
2022-12-28-12-05-56:  LOC       163697   Local timer interrupts
2022-12-28-12-05-56:  TLB         5465   TLB shootdowns

2022-12-28-12-06-00: irqtop - IRQ : 3029, TOTAL : 2179022106, CPU :
192, ACTIVE CPU : 192
remapping:
022-12-28-11-25-38: 283 325568 IR-PCI-MSI 24651790-edge vmd3

2022-12-28-11-25-38:  140       267899   IR-PCI-MSI 13117447-edge      vmd1
2022-12-28-11-25-38:  183       265978   IR-PCI-MSI 13117490-edge      vmd1

......
2022-12-28-11-25-42: irqtop - IRQ : 2109, TOTAL : 2377172002, CPU :
192, ACTIVE CPU : 192

From the result it is not difficult to find, in remapping mode the interruptions come from vmd.
While in other modes, interrupts come from nvme devices. Besides, we found the port mounting
4 dirves total interruptions is much fewer than the port mounting 2 or 1 drive. NVME 8 and 9 mount in one port, other port mount 4 dirves.

2022-12-28-11-39-14: 2582       494635   IR-PCI-MSI 470810698-edge      nvme9q74
2022-12-28-11-39-14: 2579       489972   IR-PCI-MSI 470810697-edge      nvme9q73
2022-12-28-11-39-14: 2573       480024   IR-PCI-MSI 470810695-edge      nvme9q71
2022-12-28-11-39-14: 2544       312967   IR-PCI-MSI 470286401-edge      nvme8q65
2022-12-28-11-39-14: 2556       312229   IR-PCI-MSI 470286405-edge      nvme8q69
2022-12-28-11-39-14: 2547       310013   IR-PCI-MSI 470286402-edge      nvme8q66
2022-12-28-11-39-14: 2550       308993   IR-PCI-MSI 470286403-edge      nvme8q67
2022-12-28-11-39-14: 2559       308794   IR-PCI-MSI 470286406-edge      nvme8q70
......
2022-12-28-11-39-14: 1296       185773   IR-PCI-MSI 202375243-edge      nvme1q75
2022-12-28-11-39-14: 1209       185646   IR-PCI-MSI 201850947-edge      nvme0q67
2022-12-28-11-39-14: 1831       184151   IR-PCI-MSI 203423828-edge      nvme3q84
2022-12-28-11-39-14: 1254       182313   IR-PCI-MSI 201850950-edge      nvme0q70
2022-12-28-11-39-14: 1224       181665   IR-PCI-MSI 201850948-edge      nvme0q68
2022-12-28-11-39-14: 1179       180115   IR-PCI-MSI 201850945-edge      nvme0q65
Quoted 1 line

I'd vote for it being in VMD mode (non-bypass) by default.

I speculate that the vmd controller equalizes the interrupt load and acts like a buffer,
which improves the performance of nvme. I am not sure about my analysis. So, I'd like
to discuss it with the community.

author
#8 lore raw

Friendly ping~

Quoted 61 lines · Xinghui Li <[email protected]> 于2023年1月10日周二 20:28写道:
Quoted 4 lines · Jonathan Derrick <[email protected]> 于2023年1月10日周二 05:00写道:

As the bypass mode seems to affect performance greatly depending on the specific configuration, it may make sense to use a moduleparam to control it

We found that each pcie port can mount four drives. If we only test 2 or 1 dirve of one pcie port,
the performance of the drive performance will be normal. Also, we observed the interruptions in different modes.
bypass:
.....

2022-12-28-11-39-14: 1224       181665   IR-PCI-MSI 201850948-edge      nvme0q68
2022-12-28-11-39-14: 1179       180115   IR-PCI-MSI 201850945-edge      nvme0q65
2022-12-28-11-39-14:  RES        26743   Rescheduling interrupts

2022-12-28-11-39-17: irqtop - IRQ : 3029, TOTAL : 2100315228, CPU :
192, ACTIVE CPU : 192
disable:
......

2022-12-28-12-05-56: 1714       169797   IR-PCI-MSI 14155850-edge      nvme1q74
2022-12-28-12-05-56: 1701       168753   IR-PCI-MSI 14155849-edge      nvme1q73
2022-12-28-12-05-56:  LOC       163697   Local timer interrupts
2022-12-28-12-05-56:  TLB         5465   TLB shootdowns

2022-12-28-12-06-00: irqtop - IRQ : 3029, TOTAL : 2179022106, CPU :
192, ACTIVE CPU : 192
remapping:
022-12-28-11-25-38: 283 325568 IR-PCI-MSI 24651790-edge vmd3

2022-12-28-11-25-38:  140       267899   IR-PCI-MSI 13117447-edge      vmd1
2022-12-28-11-25-38:  183       265978   IR-PCI-MSI 13117490-edge      vmd1

......
2022-12-28-11-25-42: irqtop - IRQ : 2109, TOTAL : 2377172002, CPU :
192, ACTIVE CPU : 192

From the result it is not difficult to find, in remapping mode the interruptions come from vmd.
While in other modes, interrupts come from nvme devices. Besides, we found the port mounting
4 dirves total interruptions is much fewer than the port mounting 2 or 1 drive. NVME 8 and 9 mount in one port, other port mount 4 dirves.

2022-12-28-11-39-14: 2582       494635   IR-PCI-MSI 470810698-edge      nvme9q74
2022-12-28-11-39-14: 2579       489972   IR-PCI-MSI 470810697-edge      nvme9q73
2022-12-28-11-39-14: 2573       480024   IR-PCI-MSI 470810695-edge      nvme9q71
2022-12-28-11-39-14: 2544       312967   IR-PCI-MSI 470286401-edge      nvme8q65
2022-12-28-11-39-14: 2556       312229   IR-PCI-MSI 470286405-edge      nvme8q69
2022-12-28-11-39-14: 2547       310013   IR-PCI-MSI 470286402-edge      nvme8q66
2022-12-28-11-39-14: 2550       308993   IR-PCI-MSI 470286403-edge      nvme8q67
2022-12-28-11-39-14: 2559       308794   IR-PCI-MSI 470286406-edge      nvme8q70
......
2022-12-28-11-39-14: 1296       185773   IR-PCI-MSI 202375243-edge      nvme1q75
2022-12-28-11-39-14: 1209       185646   IR-PCI-MSI 201850947-edge      nvme0q67
2022-12-28-11-39-14: 1831       184151   IR-PCI-MSI 203423828-edge      nvme3q84
2022-12-28-11-39-14: 1254       182313   IR-PCI-MSI 201850950-edge      nvme0q70
2022-12-28-11-39-14: 1224       181665   IR-PCI-MSI 201850948-edge      nvme0q68
2022-12-28-11-39-14: 1179       180115   IR-PCI-MSI 201850945-edge      nvme0q65
Quoted 1 line

I'd vote for it being in VMD mode (non-bypass) by default.

I speculate that the vmd controller equalizes the interrupt load and acts like a buffer,
which improves the performance of nvme. I am not sure about my analysis. So, I'd like
to discuss it with the community.

maintainer
#9 lore raw
Quoted 62 lines · Xinghui Li

Friendly ping~

Quoted 59 lines · Xinghui Li <[email protected]> 于2023年1月10日周二 20:28写道:
Quoted 3 lines · Jonathan Derrick <[email protected]> 于2023年1月10日周二 05:00写道:

As the bypass mode seems to affect performance greatly depending on the specific configuration, it may make sense to use a moduleparam to control it

We found that each pcie port can mount four drives. If we only test 2 or 1 dirve of one pcie port,
the performance of the drive performance will be normal. Also, we observed the interruptions in different modes.
bypass:
.....

2022-12-28-11-39-14: 1224       181665   IR-PCI-MSI 201850948-edge      nvme0q68
2022-12-28-11-39-14: 1179       180115   IR-PCI-MSI 201850945-edge      nvme0q65
2022-12-28-11-39-14:  RES        26743   Rescheduling interrupts

2022-12-28-11-39-17: irqtop - IRQ : 3029, TOTAL : 2100315228, CPU :
192, ACTIVE CPU : 192
disable:
......

2022-12-28-12-05-56: 1714       169797   IR-PCI-MSI 14155850-edge      nvme1q74
2022-12-28-12-05-56: 1701       168753   IR-PCI-MSI 14155849-edge      nvme1q73
2022-12-28-12-05-56:  LOC       163697   Local timer interrupts
2022-12-28-12-05-56:  TLB         5465   TLB shootdowns

2022-12-28-12-06-00: irqtop - IRQ : 3029, TOTAL : 2179022106, CPU :
192, ACTIVE CPU : 192
remapping:
022-12-28-11-25-38: 283 325568 IR-PCI-MSI 24651790-edge vmd3

2022-12-28-11-25-38:  140       267899   IR-PCI-MSI 13117447-edge      vmd1
2022-12-28-11-25-38:  183       265978   IR-PCI-MSI 13117490-edge      vmd1

......
2022-12-28-11-25-42: irqtop - IRQ : 2109, TOTAL : 2377172002, CPU :
192, ACTIVE CPU : 192

From the result it is not difficult to find, in remapping mode the interruptions come from vmd.
While in other modes, interrupts come from nvme devices. Besides, we found the port mounting
4 dirves total interruptions is much fewer than the port mounting 2 or 1 drive. NVME 8 and 9 mount in one port, other port mount 4 dirves.

2022-12-28-11-39-14: 2582       494635   IR-PCI-MSI 470810698-edge      nvme9q74
2022-12-28-11-39-14: 2579       489972   IR-PCI-MSI 470810697-edge      nvme9q73
2022-12-28-11-39-14: 2573       480024   IR-PCI-MSI 470810695-edge      nvme9q71
2022-12-28-11-39-14: 2544       312967   IR-PCI-MSI 470286401-edge      nvme8q65
2022-12-28-11-39-14: 2556       312229   IR-PCI-MSI 470286405-edge      nvme8q69
2022-12-28-11-39-14: 2547       310013   IR-PCI-MSI 470286402-edge      nvme8q66
2022-12-28-11-39-14: 2550       308993   IR-PCI-MSI 470286403-edge      nvme8q67
2022-12-28-11-39-14: 2559       308794   IR-PCI-MSI 470286406-edge      nvme8q70
......
2022-12-28-11-39-14: 1296       185773   IR-PCI-MSI 202375243-edge      nvme1q75
2022-12-28-11-39-14: 1209       185646   IR-PCI-MSI 201850947-edge      nvme0q67
2022-12-28-11-39-14: 1831       184151   IR-PCI-MSI 203423828-edge      nvme3q84
2022-12-28-11-39-14: 1254       182313   IR-PCI-MSI 201850950-edge      nvme0q70
2022-12-28-11-39-14: 1224       181665   IR-PCI-MSI 201850948-edge      nvme0q68
2022-12-28-11-39-14: 1179       180115   IR-PCI-MSI 201850945-edge      nvme0q65
Quoted 1 line

I'd vote for it being in VMD mode (non-bypass) by default.

I speculate that the vmd controller equalizes the interrupt load and acts like a buffer,
which improves the performance of nvme. I am not sure about my analysis. So, I'd like
to discuss it with the community.

I like the idea of module parameter to allow switching between the modes but keep MSI remapping enabled (non-bypass) by default.

#10 lore raw
Quoted 2 lines · Nirmal

I like the idea of module parameter to allow switching between the modes but keep MSI remapping enabled (non-bypass) by default.

Isn't there a more programatic way to go about selecting the best option at
runtime? I suspect bypass is the better choice if "num_active_cpus() > pci_msix_vec_count(vmd->dev)".

author
#11 lore raw
Quoted 7 lines · Keith Busch <[email protected]> 于2023年2月7日周二 02:28写道:
Quoted 2 lines · Nirmal

I like the idea of module parameter to allow switching between the modes but keep MSI remapping enabled (non-bypass) by default.

Isn't there a more programatic way to go about selecting the best option at runtime?

Do you mean that the operating mode is automatically selected by detecting the number of devices and CPUs instead of being set manually?

Quoted 1 line

I suspect bypass is the better choice if "num_active_cpus() > pci_msix_vec_count(vmd->dev)".

For this situation, My speculation is that the PCIE nodes are over-mounted and not just because of the CPU to Drive ratio. We considered designing online nodes, because we were concerned that the IO of different chunk sizes would adapt to different MSI-X modes. I privately think that it may be logically complicated if programmatic judgments are made.

maintainer
#12 lore raw
Quoted 9 lines · Xinghui Li
Quoted 5 lines · Keith Busch <[email protected]> 于2023年2月7日周二 02:28写道:
Quoted 2 lines · Nirmal

I like the idea of module parameter to allow switching between the modes but keep MSI remapping enabled (non-bypass) by default.

Isn't there a more programatic way to go about selecting the best option at runtime?

Do you mean that the operating mode is automatically selected by detecting the number of devices and CPUs instead of being set manually?

Quoted 7 lines
Quoted 1 line

I suspect bypass is the better choice if "num_active_cpus() > pci_msix_vec_count(vmd->dev)".

For this situation, My speculation is that the PCIE nodes are over-mounted and not just because of the CPU to Drive ratio. We considered designing online nodes, because we were concerned that the IO of different chunk sizes would adapt to different MSI-X modes. I privately think that it may be logically complicated if programmatic judgments are made.

Also newer CPUs have more MSIx (128) which means we can still have better performance without bypass. It would be better if user have can chose module parameter based on their requirements. Thanks.

author
#13 lore raw
Quoted 5 lines · Patel, Nirmal <[email protected]> 于2023年2月8日周三 04:32写道:

Also newer CPUs have more MSIx (128) which means we can still have better performance without bypass. It would be better if user have can chose module parameter based on their requirements. Thanks.

All right~I will reset the patch V2 with the online node version later.

Thanks

#14 lore raw
In reply to Patel, Nirmal
Quoted 10 lines · Nirmal
Quoted 8 lines · Xinghui Li
Quoted 1 line · Keith Busch <[email protected]> 于2023年2月7日周二 02:28写道:

I suspect bypass is the better choice if "num_active_cpus() > pci_msix_vec_count(vmd->dev)".

For this situation, My speculation is that the PCIE nodes are over-mounted and not just because of the CPU to Drive ratio. We considered designing online nodes, because we were concerned that the IO of different chunk sizes would adapt to different MSI-X modes. I privately think that it may be logically complicated if programmatic judgments are made.

Quoted 3 lines

Also newer CPUs have more MSIx (128) which means we can still have better performance without bypass. It would be better if user have can chose module parameter based on their requirements. Thanks.

So what? More vectors just pushes the threshold to when bypass becomes relevant, which is exactly why I suggested it. There has to be an empirical answer to when bypass beats muxing. Why do you want a user tunable if there's a verifiable and automated better choice?

maintainer
#15 lore raw
Quoted 10 lines · Keith Busch
Quoted 9 lines · Nirmal
Quoted 8 lines · Xinghui Li
Quoted 1 line · Keith Busch <[email protected]> 于2023年2月7日周二 02:28写道:

I suspect bypass is the better choice if "num_active_cpus() > pci_msix_vec_count(vmd->dev)".

For this situation, My speculation is that the PCIE nodes are over-mounted and not just because of the CPU to Drive ratio. We considered designing online nodes, because we were concerned that the IO of different chunk sizes would adapt to different MSI-X modes. I privately think that it may be logically complicated if programmatic judgments are made.

Quoted 7 lines
Quoted 3 lines

Also newer CPUs have more MSIx (128) which means we can still have better performance without bypass. It would be better if user have can chose module parameter based on their requirements. Thanks.

So what? More vectors just pushes the threshold to when bypass becomes relevant, which is exactly why I suggested it. There has to be an empirical answer to when bypass beats muxing. Why do you want a user tunable if there's a verifiable and automated better choice?

Make sense about the automated choice. I am not sure what is the exact tipping point. The commit message includes only two cases. one 1 drive 1 CPU and second 12 drives 6 CPU. Also performance gets worse from 8 drives to 12 drives.
One the previous comments also mentioned something about FIO changing cpus_allowed; will there be an issue when VMD driver decides to bypass the remapping during the boot up, but FIO job changes the cpu_allowed?

#16 lore raw
Quoted 19 lines · Nirmal
Quoted 10 lines · Keith Busch
Quoted 9 lines · Nirmal
Quoted 8 lines · Xinghui Li
Quoted 1 line · Keith Busch <[email protected]> 于2023年2月7日周二 02:28写道:

I suspect bypass is the better choice if "num_active_cpus() > pci_msix_vec_count(vmd->dev)".

For this situation, My speculation is that the PCIE nodes are over-mounted and not just because of the CPU to Drive ratio. We considered designing online nodes, because we were concerned that the IO of different chunk sizes would adapt to different MSI-X modes. I privately think that it may be logically complicated if programmatic judgments are made.

Quoted 7 lines
Quoted 3 lines

Also newer CPUs have more MSIx (128) which means we can still have better performance without bypass. It would be better if user have can chose module parameter based on their requirements. Thanks.

So what? More vectors just pushes the threshold to when bypass becomes relevant, which is exactly why I suggested it. There has to be an empirical answer to when bypass beats muxing. Why do you want a user tunable if there's a verifiable and automated better choice?

Quoted 4 lines

Make sense about the automated choice. I am not sure what is the exact tipping point. The commit message includes only two cases. one 1 drive 1 CPU and second 12 drives 6 CPU. Also performance gets worse from 8 drives to 12 drives.

That configuration's storage performance overwhelms the CPU with interrupt context switching. That problem probably inverts when your active CPU count exceeds your VMD vectors because you'll be funnelling more interrupts into fewer CPUs, leaving other CPUs idle.

Quoted 3 lines

One the previous comments also mentioned something about FIO changing cpus_allowed; will there be an issue when VMD driver decides to bypass the remapping during the boot up, but FIO job changes the cpu_allowed?

No. Bypass mode uses managed interrupts for your nvme child devices, which sets the best possible affinity.

author
#17 lore raw
In reply to Jonathan Derrick
Quoted 23 lines · Jonathan Derrick <[email protected]> 于2022年12月22日周四 17:15写道:
Quoted 19 lines · On 12/22/22 12:26 AM, [email protected] wrote:

From: Xinghui Li <[email protected]>

Commit ee81ee84f873("PCI: vmd: Disable MSI-X remapping when possible") disable the vmd MSI-X remapping for optimizing pci performance.However, this feature severely negatively optimized performance in multi-disk situations.

In FIO 4K random test, we test 1 disk in the 1 CPU

when disable MSI-X remapping:
read: IOPS=1183k, BW=4622MiB/s (4847MB/s)(1354GiB/300001msec)
READ: bw=4622MiB/s (4847MB/s), 4622MiB/s-4622MiB/s (4847MB/s-4847MB/s), io=1354GiB (1454GB), run=300001-300001msec

When not disable MSI-X remapping:
read: IOPS=1171k, BW=4572MiB/s (4795MB/s)(1340GiB/300001msec)
READ: bw=4572MiB/s (4795MB/s), 4572MiB/s-4572MiB/s (4795MB/s-4795MB/s), io=1340GiB (1438GB), run=300001-300001msec

Quoted 5 lines
Quoted 2 lines

However, the bypass mode could increase the interrupts costs in CPU. We test 12 disks in the 6 CPU,

Well the bypass mode was made to improve performance where you have >4 drives so this is pretty surprising. With bypass mode disabled, VMD will intercept and forward interrupts, increasing costs.

We also find the more drives we tested, the more severe the performance degradation.
When we tested 8 drives in 6 CPU, there is about 30% drop.

Quoted 2 lines

I think Nirmal would want to to understand if there's some other factor going on here.

I also agree with this. The tested server is None io-scheduler. We tested the same server. Tested drives are Samsung Gen-4 nvme. Is there anything else you worried effecting test results?