net/mlx5: net/mlx5: Fix some error messages
Subsystems (5)
PATCH v2 1/1 net/mlx5: net/mlx5: Fix some error messages
This code was using IS_ERR() instead of PTR_ERR() so it prints 1 instead of the correct error code. Even better would be to use %pe which prints out the name of the error, as in "ENOMEM", "EINVAL" etc.
Fixes 25cb31768042 ("net/mlx5: E-Switch, Improve error messages in term table creation")
Signed-off-by Dan Carpenter <[email protected]>
---
v2: Use %pe instead of %ld.
Leon says this goes through netdev instead of the RDMA tree.
.../mellanox/mlx5/core/eswitch_offloads_termtbl.c | 12 ++++++------ 1 file changed, 6 insertions(+), 6 deletions(-)
drivers/net/ethernet/mellanox/mlx5/core/eswitch_offloads_termtbl.c +6 -6
@@ -83,16 +83,16 @@ mlx5_eswitch_termtbl_create(struct mlx5_core_dev *dev, ft_attr.autogroup.max_num_groups =1 ; tt->termtbl =mlx5_create_auto_grouped_flow_table (root_ns, &ft_attr);if (IS_ERR (tt->termtbl)) { -esw_warn (dev,"Failed to create termination table (error %d)\n" , -IS_ERR (tt->termtbl)); +esw_warn (dev,"Failed to create termination table (error %pe)\n" , + tt->termtbl);return -EOPNOTSUPP ; } tt->rule =mlx5_add_flow_rules (tt->termtbl,NULL , flow_act, &tt->dest,1 );if (IS_ERR (tt->rule)) { -esw_warn (dev,"Failed to create termination table rule (error %d)\n" , -IS_ERR (tt->rule)); +esw_warn (dev,"Failed to create termination table rule (error %pe)\n" , + tt->rule); goto add_flow_err; }return 0 ;
@@ -283,8 +283,8 @@ mlx5_eswitch_add_termtbl_rule(struct mlx5_eswitch *esw, tt =mlx5_eswitch_termtbl_get_create (esw, &term_tbl_act, &dest[i], attr);if (IS_ERR (tt)) { -esw_warn (esw->dev,"Failed to get termination table (error %d)\n" , -IS_ERR (tt)); +esw_warn (esw->dev,"Failed to get termination table (error %pe)\n" , + tt); goto revert_changes; } attr->dests[num_vport_dests].termtbl = tt;
Signature · 1 line
2.30.2
Quoted 10 lines · Dan Carpenter
This code was using
IS_ERR()instead ofPTR_ERR()so it prints 1 instead of the correct error code. Even better would be to use %pe which prints out the name of the error, as in "ENOMEM", "EINVAL" etc.Fixes 25cb31768042 ("net/mlx5: E-Switch, Improve error messages in term table creation")Signed-off-by Dan Carpenter <[email protected]>---
v2: Use %pe instead of %ld.Leon says this goes through netdev instead of the RDMA tree.
Thanks,
Reviewed-by Leon Romanovsky <[email protected]>