automation: save xen config before building

PATCH In review Wei Liu 2 participants 3 messages May 5, 2021

lore
Share & tools
lore

Wei Liu

author
#0 lore raw

PATCH 1/1 automation: save xen config before building

It is reported that failed randconfig runs are missing the config file which makes debugging impossible. Fix this by moving the line that copies the config file before the build is executed.

---
 automation/scripts/build | 5 ++++-
 1 file changed, 4 insertions(+), 1 deletion(-)
automation/scripts/build +4 -1
index eaf70b11d1cb..46b6903d2922 100755
@@ -16,6 +16,10 @@ else
     make -j$(nproc) -C xen defconfig
 fi
 
+# Save the config file before building because build failure causes the script
+# to exit early -- bash is invoked with -e.
+cp xen/.config xen-config
+
 # arm32 only cross-compiles the hypervisor
 if [[ "${XEN_TARGET_ARCH}" = "arm32" ]]; then
     hypervisor_only="y"
@@ -59,7 +63,6 @@ else
 fi
 
 # Extract artifacts to avoid getting rewritten by customised builds
-cp xen/.config xen-config
 mkdir binaries
 if [[ "${XEN_TARGET_ARCH}" != "x86_32" ]]; then
     cp xen/xen binaries/xen
Signature · 1 line
2.30.2
author
#2 lore raw
Quoted 8 lines · Roger Pau Monné
Quoted 5 lines · Wei Liu

It is reported that failed randconfig runs are missing the config file which makes debugging impossible. Fix this by moving the line that copies the config file before the build is executed.

A patchew run shows this indeed fixes the issue. I've pushed this to staging.

Wei.

Quoted 2 lines

Thanks!