Skip to contentSkip to conversation

soundwire: cadence_master: always set CMD_ACCEPT

PATCH RESEND Applied Bard Liao 2 participants 2 messages May 11, 2021 SoundWire

lore
Share & tools
lore

Bard Liao

author maintainer
#0 lore raw

PATCH RESEND 1/1 soundwire: cadence_master: always set CMD_ACCEPT

From: Pierre-Louis Bossart <[email protected]>

The Cadence IP can be configured in two different ways to deal with CMD_IGNORED replies to broadcast commands. The CMD_ACCEPT bitfield controls whether the command is discarded or if the IP proceeds with the change (typically a bank switch or clock stop command).

The existing code seems to be inconsistent:
a) For some historical reason, we set this CMD_ACCEPT bitfield during the initialization, but we don't during a resume from a clock-stoppped state.
b) In addition, the loop used in the clock-stop sequence is quite racy, it's possible that a device has lost sync but it's still tagged as ATTACHED.
c) If somehow a Device loses sync and is unable to ack a broadcast command, we do not have an error handling mechanism anyways. The IP should go ahead and let the Device regain sync at a later time.

Make sure the CMD_ACCEPT bit is always set.

---
 drivers/soundwire/cadence_master.c | 21 ++-------------------
 1 file changed, 2 insertions(+), 19 deletions(-)
drivers/soundwire/cadence_master.c +2 -19
index 192dac10f0c2..25950422b085 100644
@@ -1428,20 +1428,6 @@ int sdw_cdns_clock_stop(struct sdw_cdns *cdns, bool block_wake)
 		}
 	}
 
-	/*
-	 * This CMD_ACCEPT should be used when there are no devices
-	 * attached on the link when entering clock stop mode. If this is
-	 * not set and there is a broadcast write then the command ignored
-	 * will be treated as a failure
-	 */
-	if (!slave_present)
-		cdns_updatel(cdns, CDNS_MCP_CONTROL,
-			     CDNS_MCP_CONTROL_CMD_ACCEPT,
-			     CDNS_MCP_CONTROL_CMD_ACCEPT);
-	else
-		cdns_updatel(cdns, CDNS_MCP_CONTROL,
-			     CDNS_MCP_CONTROL_CMD_ACCEPT, 0);
-
 	/* commit changes */
 	ret = cdns_config_update(cdns);
 	if (ret < 0) {
@@ -1508,11 +1494,8 @@ int sdw_cdns_clock_restart(struct sdw_cdns *cdns, bool bus_reset)
 	cdns_updatel(cdns, CDNS_MCP_CONTROL,
 		     CDNS_MCP_CONTROL_BLOCK_WAKEUP, 0);
 
-	/*
-	 * clear CMD_ACCEPT so that the command ignored
-	 * will be treated as a failure during a broadcast write
-	 */
-	cdns_updatel(cdns, CDNS_MCP_CONTROL, CDNS_MCP_CONTROL_CMD_ACCEPT, 0);
+	cdns_updatel(cdns, CDNS_MCP_CONTROL, CDNS_MCP_CONTROL_CMD_ACCEPT,
+		     CDNS_MCP_CONTROL_CMD_ACCEPT);
 
 	if (!bus_reset) {
 
Signature · 1 line
2.17.1
maintainer Applied
#1 lore raw
Quoted 18 lines · Bard Liao

From: Pierre-Louis Bossart <[email protected]>

The Cadence IP can be configured in two different ways to deal with CMD_IGNORED replies to broadcast commands. The CMD_ACCEPT bitfield controls whether the command is discarded or if the IP proceeds with the change (typically a bank switch or clock stop command).

The existing code seems to be inconsistent:
a) For some historical reason, we set this CMD_ACCEPT bitfield during the initialization, but we don't during a resume from a clock-stoppped state.
b) In addition, the loop used in the clock-stop sequence is quite racy, it's possible that a device has lost sync but it's still tagged as ATTACHED.
c) If somehow a Device loses sync and is unable to ack a broadcast command, we do not have an error handling mechanism anyways. The IP should go ahead and let the Device regain sync at a later time.

Quoted 1 line

Make sure the CMD_ACCEPT bit is always set.

Applied, thanks

Signature · 1 line
~Vinod