Input: ili210x - Reduce sample period to 15ms
Subsystems (2)
PATCH 1/1 Input: ili210x - Reduce sample period to 15ms
Modern devices may redraw display at 60 Hz, make sure we have one input sample per one frame. Reduce sample period to 15ms, so we would get up to 66.6 samples per second, although realistically with all the jitter and extra scheduling wiggle room, we would end up just above 60 samples per second. This should be a good compromise between sampling too often and sampling too seldom.
--- drivers/input/touchscreen/ili210x.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-)
drivers/input/touchscreen/ili210x.c +1 -1
@@ -14,7 +14,7 @@#include <linux/slab.h> #include <asm/unaligned.h> -#define ILI2XXX_POLL_PERIOD 20 +#define ILI2XXX_POLL_PERIOD 15#define ILI210X_DATA_SIZE 64#define ILI211X_DATA_SIZE 43
Signature · 1 line
2.33.0
Quoted 11 lines · Marek Vasut
Modern devices may redraw display at 60 Hz, make sure we have one input sample per one frame. Reduce sample period to 15ms, so we would get up to 66.6 samples per second, although realistically with all the jitter and extra scheduling wiggle room, we would end up just above 60 samples per second. This should be a good compromise between sampling too often and sampling too seldom.
Signed-off-by Marek Vasut <[email protected]>Cc Dmitry Torokhov <[email protected]>Cc Joe Hung <[email protected]>Cc Luca Hsu <[email protected]>
Applied, thank you.
Signature · 1 line
Dmitry