usb:typec: Add sysfs support for Type C connector's physical location
Subsystems (2)
PATCH v2 1/1 usb:typec: Add sysfs support for Type C connector's physical location
When ACPI table includes _PLD field for a Type C connector, share _PLD values in its sysfs. _PLD stands for physical location of device.
Currently without connector's location information, when there are multiple Type C ports, it is hard to distinguish which connector corresponds to which physical port at which location. For example, when there are two Type C connectors, it is hard to find out which connector corresponds to the Type C port on the left panel versus the Type C port on the right panel. With location information provided, we can determine which specific device at which location is doing what.
_PLD output includes much more fields, but only generic fields are added and exposed to sysfs, so that non-ACPI devices can also support it in the future. The minimal generic fields needed for locating a port are the following.
- panel
- vertical_position
- horizontal_position
- dock
- lid
---
Changes in v2:
- Use string for location.
- Clarify get_pld() with naming and return type.
Documentation/ABI/testing/sysfs-class-typec | 35 ++++++ drivers/usb/typec/class.c | 113 ++++++++++++++++++++ drivers/usb/typec/class.h | 3 + 3 files changed, 151 insertions(+)
Documentation/ABI/testing/sysfs-class-typec +35 -0
@@ -141,6 +141,41 @@ Description: - "reverse": CC2 orientation - "unknown": Orientation cannot be determined. +What: /sys/class/typec/<port>/location/panel +Date: March 2022 +Contact: Won Chung <[email protected]> +Description: + Describes which panel surface of the system’s housing the + port resides on. + +What: /sys/class/typec/<port>/location/vertical_position +Date: March 2022 +Contact: Won Chung <[email protected]> +Description: + Describes vertical position of the port on the panel surface. + Valid values: upper, center, lower + +What: /sys/class/typec/<port>/location/horizontal_position +Date: March 2022 +Contact: Won Chung <[email protected]> +Description: + Describes horizontal position of the port on the panel surface. + Valid values: left, center, right + +What: /sys/class/typec/<port>/location/dock +Date: March 2022 +Contact: Won Chung <[email protected]> +Description: + Set as "yes" if the port resides in a docking station or a port + replicator, otherwise set as "no". + +What: /sys/class/typec/<port>/location/lid +Date: March 2022 +Contact: Won Chung <[email protected]> +Description: + Set as "yes" if the port resides on the lid of laptop system, + otherwise set as "no". + USB Type-C partner devices (eg. /sys/class/typec/port0-partner/) What: /sys/class/typec/<port>-partner/accessory_mode
drivers/usb/typec/class.c +113 -0
133 lines not on this page · raw message
drivers/usb/typec/class.h +3 -0
@@ -3,6 +3,7 @@#ifndef __USB_TYPEC_CLASS__#define __USB_TYPEC_CLASS__ +#include <linux/acpi.h> #include <linux/device.h> #include <linux/usb/typec.h>
@@ -54,6 +55,8 @@ struct typec_port {const struct typec_capability *cap;const struct typec_operations *ops; + +struct acpi_pld_info *pld; };#define to_typec_port (_dev_) container_of(_dev_, struct typec_port, dev)
Signature · 1 line
2.35.1.574.g5d30c73bfb-goog
Heikki Krogerus
maintainerHi Won,
Quoted 66 lines · Won Chung
When ACPI table includes
_PLDfield for a Type C connector, share_PLDvalues in its sysfs._PLDstands for physical location of device.Currently without connector's location information, when there are multiple Type C ports, it is hard to distinguish which connector corresponds to which physical port at which location. For example, when there are two Type C connectors, it is hard to find out which connector corresponds to the Type C port on the left panel versus the Type C port on the right panel. With location information provided, we can determine which specific device at which location is doing what.
_PLDoutput includes much more fields, but only generic fields are added and exposed to sysfs, so that non-ACPI devices can also support it in the future. The minimal generic fields needed for locating a port are the following.
- panel
-vertical_position
-horizontal_position
- dock
- lidSigned-off-by Won Chung <[email protected]>---
Changes in v2:
- Use string for location.
- Clarifyget_pld()with naming and return type.Documentation/ABI/testing/sysfs-class-typec | 35 ++++++ drivers/usb/typec/class.c | 113 ++++++++++++++++++++ drivers/usb/typec/class.h | 3 + 3 files changed, 151 insertions(+)Documentation/ABI/testing/sysfs-class-typec +25
-0@@ -141,6 +141,41 @@ Description: - "reverse": CC2 orientation - "unknown": Orientation cannot be determined. +What: /sys/class/typec/<port>/location/panel +Date: March 2022 +Contact: Won Chung <[email protected]> +Description: + Describes which panel surface of the system’s housing the + port resides on. + +What: /sys/class/typec/<port>/location/vertical_position +Date: March 2022 +Contact: Won Chung <[email protected]> +Description: + Describes vertical position of the port on the panel surface. + Valid values: upper, center, lower + +What: /sys/class/typec/<port>/location/horizontal_position +Date: March 2022 +Contact: Won Chung <[email protected]> +Description: + Describes horizontal position of the port on the panel surface. + Valid values: left, center, right + +What: /sys/class/typec/<port>/location/dock +Date: March 2022 +Contact: Won Chung <[email protected]> +Description:
Documentation/ABI/testing/sysfs-class-typec Description: · line 178
Quoted 10 lines
Documentation/ABI/testing/sysfs-class-typec +10
-0+ Set as "yes" if the port resides in a docking station or a port + replicator, otherwise set as "no". + +What: /sys/class/typec/<port>/location/lid +Date: March 2022 +Contact: Won Chung <[email protected]> +Description: + Set as "yes" if the port resides on the lid of laptop system, + otherwise set as "no". +
I've probable lost track of the topic during my winter break, I'm sorry about that, but why are you proposing now that this should be made Type-C specific?
This information is not Type-C specific, so it definitely does not belong here.
Br,
Signature · 1 line
heikki
Quoted 87 lines · Heikki Krogerus
Hi Won,
Quoted 66 lines · Won Chung
When ACPI table includes
_PLDfield for a Type C connector, share_PLDvalues in its sysfs._PLDstands for physical location of device.Currently without connector's location information, when there are multiple Type C ports, it is hard to distinguish which connector corresponds to which physical port at which location. For example, when there are two Type C connectors, it is hard to find out which connector corresponds to the Type C port on the left panel versus the Type C port on the right panel. With location information provided, we can determine which specific device at which location is doing what.
_PLDoutput includes much more fields, but only generic fields are added and exposed to sysfs, so that non-ACPI devices can also support it in the future. The minimal generic fields needed for locating a port are the following.
- panel
-vertical_position
-horizontal_position
- dock
- lidSigned-off-by Won Chung <[email protected]>---
Changes in v2:
- Use string for location.
- Clarifyget_pld()with naming and return type.Documentation/ABI/testing/sysfs-class-typec | 35 ++++++ drivers/usb/typec/class.c | 113 ++++++++++++++++++++ drivers/usb/typec/class.h | 3 + 3 files changed, 151 insertions(+)Documentation/ABI/testing/sysfs-class-typec +25
-0@@ -141,6 +141,41 @@ Description: - "reverse": CC2 orientation - "unknown": Orientation cannot be determined. +What: /sys/class/typec/<port>/location/panel +Date: March 2022 +Contact: Won Chung <[email protected]> +Description: + Describes which panel surface of the system’s housing the + port resides on. + +What: /sys/class/typec/<port>/location/vertical_position +Date: March 2022 +Contact: Won Chung <[email protected]> +Description: + Describes vertical position of the port on the panel surface. + Valid values: upper, center, lower + +What: /sys/class/typec/<port>/location/horizontal_position +Date: March 2022 +Contact: Won Chung <[email protected]> +Description: + Describes horizontal position of the port on the panel surface. + Valid values: left, center, right + +What: /sys/class/typec/<port>/location/dock +Date: March 2022 +Contact: Won Chung <[email protected]> +Description:Documentation/ABI/testing/sysfs-class-typec Description: · line 178
Quoted 10 lines
Documentation/ABI/testing/sysfs-class-typec +10
-0+ Set as "yes" if the port resides in a docking station or a port + replicator, otherwise set as "no". + +What: /sys/class/typec/<port>/location/lid +Date: March 2022 +Contact: Won Chung <[email protected]> +Description: + Set as "yes" if the port resides on the lid of laptop system, + otherwise set as "no". +I've probable lost track of the topic during my winter break, I'm sorry about that, but why are you proposing now that this should be made Type-C specific?
This information is not Type-C specific, so it definitely does not belong here.
Quoted 4 lines
Br,
--
heikki
Hi Heikki,
Thank you for the comment. Sorry that my description was not clear.
This is follow up from "[PATCH v6] ACPI: device_sysfs: Add sysfs
support for _PLD" in which Rafael suggested to have generic location
in Type C connector than adding PLD specifically to ACPI device. I was
also convinced by Rafael since userspace code would also be quite
ACPI-specific to access PLD in ACPI device sysfs. The discussion can
be found in https://lore.kernel.org/all/CAOvb9yh7uNg9ZU3RsieGChsjLCfKQhHhipBi4RMuQYKEA4fu9A@mail.gmail.com/.
For your reference, in a diverged email thread, Greg also gave a
feedback: https://lore.kernel.org/all/[email protected]/.
Do you think it is still better to have this location information in ACPI device? I would appreciate it if you can share your thoughts in the original thread where the discussion is. Thank you very much!
Won
Quoted 95 lines · Won Chung
Quoted 87 lines · Heikki Krogerus
Hi Won,
Quoted 66 lines · Won Chung
When ACPI table includes
_PLDfield for a Type C connector, share_PLDvalues in its sysfs._PLDstands for physical location of device.Currently without connector's location information, when there are multiple Type C ports, it is hard to distinguish which connector corresponds to which physical port at which location. For example, when there are two Type C connectors, it is hard to find out which connector corresponds to the Type C port on the left panel versus the Type C port on the right panel. With location information provided, we can determine which specific device at which location is doing what.
_PLDoutput includes much more fields, but only generic fields are added and exposed to sysfs, so that non-ACPI devices can also support it in the future. The minimal generic fields needed for locating a port are the following.
- panel
-vertical_position
-horizontal_position
- dock
- lidSigned-off-by Won Chung <[email protected]>---
Changes in v2:
- Use string for location.
- Clarifyget_pld()with naming and return type.Documentation/ABI/testing/sysfs-class-typec | 35 ++++++ drivers/usb/typec/class.c | 113 ++++++++++++++++++++ drivers/usb/typec/class.h | 3 + 3 files changed, 151 insertions(+)Documentation/ABI/testing/sysfs-class-typec +25
-0@@ -141,6 +141,41 @@ Description: - "reverse": CC2 orientation - "unknown": Orientation cannot be determined. +What: /sys/class/typec/<port>/location/panel +Date: March 2022 +Contact: Won Chung <[email protected]> +Description: + Describes which panel surface of the system’s housing the + port resides on. + +What: /sys/class/typec/<port>/location/vertical_position +Date: March 2022 +Contact: Won Chung <[email protected]> +Description: + Describes vertical position of the port on the panel surface. + Valid values: upper, center, lower + +What: /sys/class/typec/<port>/location/horizontal_position +Date: March 2022 +Contact: Won Chung <[email protected]> +Description: + Describes horizontal position of the port on the panel surface. + Valid values: left, center, right + +What: /sys/class/typec/<port>/location/dock +Date: March 2022 +Contact: Won Chung <[email protected]> +Description:Documentation/ABI/testing/sysfs-class-typec Description: · line 178
Quoted 10 lines
Documentation/ABI/testing/sysfs-class-typec +10
-0+ Set as "yes" if the port resides in a docking station or a port + replicator, otherwise set as "no". + +What: /sys/class/typec/<port>/location/lid +Date: March 2022 +Contact: Won Chung <[email protected]> +Description: + Set as "yes" if the port resides on the lid of laptop system, + otherwise set as "no". +I've probable lost track of the topic during my winter break, I'm sorry about that, but why are you proposing now that this should be made Type-C specific?
This information is not Type-C specific, so it definitely does not belong here.Quoted 4 lines
Br,
--
heikki
Quoted 6 lines
Hi Heikki,
Thank you for the comment. Sorry that my description was not clear. This is follow up from "[PATCH v6] ACPI:
device_sysfs: Add sysfs support for_PLD" in which Rafael suggested to have generic location in Type C connector than adding PLD specifically to ACPI device.
Well, this doesn't have to be /sys/class/typec/<port>/location/ though.
For example, the device location information can be exposed in a more generic way is /sys/devices/.../location/ for all devices for which it is available, somewhat in analogy to /sys/devices/.../power/.
Heikki Krogerus
maintainerQuoted 103 lines · Rafael J. Wysocki
Quoted 95 lines · Won Chung
Quoted 87 lines · Heikki Krogerus
Hi Won,
Quoted 66 lines · Won Chung
When ACPI table includes
_PLDfield for a Type C connector, share_PLDvalues in its sysfs._PLDstands for physical location of device.Currently without connector's location information, when there are multiple Type C ports, it is hard to distinguish which connector corresponds to which physical port at which location. For example, when there are two Type C connectors, it is hard to find out which connector corresponds to the Type C port on the left panel versus the Type C port on the right panel. With location information provided, we can determine which specific device at which location is doing what.
_PLDoutput includes much more fields, but only generic fields are added and exposed to sysfs, so that non-ACPI devices can also support it in the future. The minimal generic fields needed for locating a port are the following.
- panel
-vertical_position
-horizontal_position
- dock
- lidSigned-off-by Won Chung <[email protected]>---
Changes in v2:
- Use string for location.
- Clarifyget_pld()with naming and return type.Documentation/ABI/testing/sysfs-class-typec | 35 ++++++ drivers/usb/typec/class.c | 113 ++++++++++++++++++++ drivers/usb/typec/class.h | 3 + 3 files changed, 151 insertions(+)Documentation/ABI/testing/sysfs-class-typec +25
-0@@ -141,6 +141,41 @@ Description: - "reverse": CC2 orientation - "unknown": Orientation cannot be determined. +What: /sys/class/typec/<port>/location/panel +Date: March 2022 +Contact: Won Chung <[email protected]> +Description: + Describes which panel surface of the system’s housing the + port resides on. + +What: /sys/class/typec/<port>/location/vertical_position +Date: March 2022 +Contact: Won Chung <[email protected]> +Description: + Describes vertical position of the port on the panel surface. + Valid values: upper, center, lower + +What: /sys/class/typec/<port>/location/horizontal_position +Date: March 2022 +Contact: Won Chung <[email protected]> +Description: + Describes horizontal position of the port on the panel surface. + Valid values: left, center, right + +What: /sys/class/typec/<port>/location/dock +Date: March 2022 +Contact: Won Chung <[email protected]> +Description:Documentation/ABI/testing/sysfs-class-typec Description: · line 178
Quoted 10 lines
Documentation/ABI/testing/sysfs-class-typec +10
-0+ Set as "yes" if the port resides in a docking station or a port + replicator, otherwise set as "no". + +What: /sys/class/typec/<port>/location/lid +Date: March 2022 +Contact: Won Chung <[email protected]> +Description: + Set as "yes" if the port resides on the lid of laptop system, + otherwise set as "no". +I've probable lost track of the topic during my winter break, I'm sorry about that, but why are you proposing now that this should be made Type-C specific?
This information is not Type-C specific, so it definitely does not belong here.Quoted 4 lines
Br,
--
heikkiQuoted 6 lines
Hi Heikki,
Thank you for the comment. Sorry that my description was not clear. This is follow up from "[PATCH v6] ACPI:
device_sysfs: Add sysfs support for_PLD" in which Rafael suggested to have generic location in Type C connector than adding PLD specifically to ACPI device.
Quoted 5 lines
Well, this doesn't have to be /sys/class/typec/<port>/location/ though.
For example, the device location information can be exposed in a more generic way is
/sys/devices/.../location/for all devices for which it is available, somewhat in analogy to/sys/devices/.../power/.
Right, that's what I meant. These can be made generic.
thanks,
Signature · 1 line
heikki
Quoted 111 lines · Heikki Krogerus
Quoted 103 lines · Rafael J. Wysocki
Quoted 95 lines · Won Chung
Quoted 87 lines · Heikki Krogerus
Hi Won,
Quoted 66 lines · Won Chung
When ACPI table includes
_PLDfield for a Type C connector, share_PLDvalues in its sysfs._PLDstands for physical location of device.Currently without connector's location information, when there are multiple Type C ports, it is hard to distinguish which connector corresponds to which physical port at which location. For example, when there are two Type C connectors, it is hard to find out which connector corresponds to the Type C port on the left panel versus the Type C port on the right panel. With location information provided, we can determine which specific device at which location is doing what.
_PLDoutput includes much more fields, but only generic fields are added and exposed to sysfs, so that non-ACPI devices can also support it in the future. The minimal generic fields needed for locating a port are the following.
- panel
-vertical_position
-horizontal_position
- dock
- lidSigned-off-by Won Chung <[email protected]>---
Changes in v2:
- Use string for location.
- Clarifyget_pld()with naming and return type.Documentation/ABI/testing/sysfs-class-typec | 35 ++++++ drivers/usb/typec/class.c | 113 ++++++++++++++++++++ drivers/usb/typec/class.h | 3 + 3 files changed, 151 insertions(+)Documentation/ABI/testing/sysfs-class-typec +25
-0@@ -141,6 +141,41 @@ Description: - "reverse": CC2 orientation - "unknown": Orientation cannot be determined. +What: /sys/class/typec/<port>/location/panel +Date: March 2022 +Contact: Won Chung <[email protected]> +Description: + Describes which panel surface of the system’s housing the + port resides on. + +What: /sys/class/typec/<port>/location/vertical_position +Date: March 2022 +Contact: Won Chung <[email protected]> +Description: + Describes vertical position of the port on the panel surface. + Valid values: upper, center, lower + +What: /sys/class/typec/<port>/location/horizontal_position +Date: March 2022 +Contact: Won Chung <[email protected]> +Description: + Describes horizontal position of the port on the panel surface. + Valid values: left, center, right + +What: /sys/class/typec/<port>/location/dock +Date: March 2022 +Contact: Won Chung <[email protected]> +Description:Documentation/ABI/testing/sysfs-class-typec Description: · line 178
Quoted 10 lines
Documentation/ABI/testing/sysfs-class-typec +10
-0+ Set as "yes" if the port resides in a docking station or a port + replicator, otherwise set as "no". + +What: /sys/class/typec/<port>/location/lid +Date: March 2022 +Contact: Won Chung <[email protected]> +Description: + Set as "yes" if the port resides on the lid of laptop system, + otherwise set as "no". +I've probable lost track of the topic during my winter break, I'm sorry about that, but why are you proposing now that this should be made Type-C specific?
This information is not Type-C specific, so it definitely does not belong here.Quoted 4 lines
Br,
--
heikkiQuoted 6 lines
Hi Heikki,
Thank you for the comment. Sorry that my description was not clear. This is follow up from "[PATCH v6] ACPI:
device_sysfs: Add sysfs support for_PLD" in which Rafael suggested to have generic location in Type C connector than adding PLD specifically to ACPI device.Quoted 5 lines
Well, this doesn't have to be /sys/class/typec/<port>/location/ though.
For example, the device location information can be exposed in a more generic way is
/sys/devices/.../location/for all devices for which it is available, somewhat in analogy to/sys/devices/.../power/.
Quoted 6 lines
Right, that's what I meant. These can be made generic.
thanks,
--
heikki
Hi Heikki and Rafael,
Thank you for clarification and guidance. I created and sent a new patch on driver core for /sys/devices/.../location/.
Won