Skip to contentSkip to conversation

power: supply: bq27xxx: do not report incorrect zero values

PATCH In review Sicelo A. Mhlongo 2 participants 3 messages Mar 22, 2025 – Mar 24, 2025

Subsystems (3)
lore
Share & tools
lore
#0 lore raw

PATCH v2 1/1 power: supply: bq27xxx: do not report incorrect zero values

On the bq27x00 and bq27x10 variants, a number of conditions can reset the value stored in the NAC register. This will cause capacity, time-to-empty, energy, and charge to report the value 0, even when the battery is full. On the other hand, the chips provide a flag, EDVF, which reliably reports the true battery empty condition, when these properties are really zero. Therefore, discard readings for these properties if their value is 0 while EDVF is unset.

Tested on the Nokia N900 with bq27200.

---
 drivers/power/supply/bq27xxx_battery.c | 24 ++++++++++++++++++++++--
 1 file changed, 22 insertions(+), 2 deletions(-)
drivers/power/supply/bq27xxx_battery.c +22 -2
index 2f31d750a4c1..8e5795c5754e 100644
@@ -2107,6 +2107,15 @@ static int bq27xxx_battery_read_dmin_volt(struct bq27xxx_device_info *di,
 	return 0;
 }
 
+static bool bq27xxx_value_is_valid(struct bq27xxx_device_info *di, int value)
+{
+	/*
+	 * On bq27xxx_0_zero, consider zero values invalid if EDVF is not set
+	 */
+	return value || !(di->opts & BQ27XXX_O_ZERO) ||
+	       (di->cache.flags & BQ27000_FLAG_EDVF);
+}
+
 static int bq27xxx_simple_value(int value,
 				union power_supply_propval *val)
 {
@@ -2147,6 +2156,8 @@ static int bq27xxx_battery_get_property(struct power_supply *psy,
 		ret = bq27xxx_battery_current_and_status(di, val, NULL, NULL);
 		break;
 	case POWER_SUPPLY_PROP_CAPACITY:
+		if (!bq27xxx_value_is_valid(di, di->cache.capacity))
+			return -EINVAL;
 		ret = bq27xxx_simple_value(di->cache.capacity, val);
 		break;
 	case POWER_SUPPLY_PROP_CAPACITY_LEVEL:
@@ -2157,9 +2168,13 @@ static int bq27xxx_battery_get_property(struct power_supply *psy,
 		break;
 	case POWER_SUPPLY_PROP_TIME_TO_EMPTY_NOW:
 		ret = bq27xxx_battery_read_time(di, BQ27XXX_REG_TTE, val);
+		if (!ret && !bq27xxx_value_is_valid(di, val->intval))
+			return -EINVAL;
 		break;
 	case POWER_SUPPLY_PROP_TIME_TO_EMPTY_AVG:
 		ret = bq27xxx_battery_read_time(di, BQ27XXX_REG_TTECP, val);
+		if (!ret && !bq27xxx_value_is_valid(di, val->intval))
+			return -EINVAL;
 		break;
 	case POWER_SUPPLY_PROP_TIME_TO_FULL_NOW:
 		ret = bq27xxx_battery_read_time(di, BQ27XXX_REG_TTF, val);
@@ -2171,10 +2186,13 @@ static int bq27xxx_battery_get_property(struct power_supply *psy,
 			val->intval = POWER_SUPPLY_TECHNOLOGY_LION;
 		break;
 	case POWER_SUPPLY_PROP_CHARGE_NOW:
-		if (di->regs[BQ27XXX_REG_NAC] != INVALID_REG_ADDR)
+		if (di->regs[BQ27XXX_REG_NAC] != INVALID_REG_ADDR) {
 			ret = bq27xxx_battery_read_nac(di, val);
-		else
+			if (!ret && !bq27xxx_value_is_valid(di, val->intval))
+				return -EINVAL;
+		} else {
 			ret = bq27xxx_battery_read_rc(di, val);
+		}
 		break;
 	case POWER_SUPPLY_PROP_CHARGE_FULL:
 		ret = bq27xxx_battery_read_fcc(di, val);
@@ -2199,6 +2217,8 @@ static int bq27xxx_battery_get_property(struct power_supply *psy,
 		break;
 	case POWER_SUPPLY_PROP_ENERGY_NOW:
 		ret = bq27xxx_battery_read_energy(di, val);
+		if (!ret && !bq27xxx_value_is_valid(di, val->intval))
+			return -EINVAL;
 		break;
 	case POWER_SUPPLY_PROP_POWER_AVG:
 		ret = bq27xxx_battery_pwr_avg(di, val);
Signature · 1 line
2.49.0
#1 lore raw

Hi Sicelo,

Quoted 22 lines

Am 22.03.2025 um 16:43 schrieb Sicelo A. Mhlongo <[email protected]>:

On the bq27x00 and bq27x10 variants, a number of conditions can reset the value stored in the NAC register. This will cause capacity, time-to-empty, energy, and charge to report the value 0, even when the battery is full. On the other hand, the chips provide a flag, EDVF, which reliably reports the true battery empty condition, when these properties are really zero. Therefore, discard readings for these properties if their value is 0 while EDVF is unset.

Tested on the Nokia N900 with bq27200.

---
drivers/power/supply/bq27xxx_battery.c | 24 ++++++++++++++++++++++--

1 file changed, 22 insertions(+), 2 deletions(-)
drivers/power/supply/bq27xxx_battery.c +0 -0
index 2f31d750a4c1..8e5795c5754e 100644

drivers/power/supply/bq27xxx_battery.c static int bq27xxx_battery_read_dmin_volt(struct bq27xxx_device_info *di, · line 2116

Quoted 10 lines
drivers/power/supply/bq27xxx_battery.c +7 -0
@@ -2107,6 +2107,15 @@ static int bq27xxx_battery_read_dmin_volt(struct bq27xxx_device_info *di,
 return 0;
 }
 
+static bool bq27xxx_value_is_valid(struct bq27xxx_device_info *di, int value)
+{
+ /*
+ * On bq27xxx_0_zero, consider zero values invalid if EDVF is not set
+ */
+ return value || !(di->opts & BQ27XXX_O_ZERO) ||
+       (di->cache.flags & BQ27000_FLAG_EDVF);

Hm. This still can return -EINVAL for a valid and successful readout of value == 0 which could happen for a fully drained HF08 in the GTA04 with bq27000.

Here is an excerpt from running a battery until depletion:

root@letux:~# echo off >/sys/class/power_supply/twl4030_usb/mode
root@letux:~# while true; do echo $(date) $(cat /sys/class/power_supply/bq27000-battery/capacity)%; sleep 1; done

Mon Mar 24 14:37:11 UTC 2025 1%
Mon Mar 24 14:37:12 UTC 2025 1%
Mon Mar 24 14:37:13 UTC 2025 1%
...

Mon Mar 24 14:38:24 UTC 2025 1%
Mon Mar 24 14:38:25 UTC 2025 1%
Mon Mar 24 14:38:26 UTC 2025 1%
Mon Mar 24 14:38:27 UTC 2025 1%
cat: /sys/class/power_supply/bq27000-battery/capacity: Invalid argument Mon Mar 24 14:38:28 UTC 2025 %
cat: /sys/class/power_supply/bq27000-battery/capacity: Invalid argument Mon Mar 24 14:38:29 UTC 2025 %
cat: /sys/class/power_supply/bq27000-battery/capacity: Invalid argument Mon Mar 24 14:38:30 UTC 2025 %
cat: /sys/class/power_supply/bq27000-battery/capacity: Invalid argument Mon Mar 24 14:38:32 UTC 2025 %
...
cat: /sys/class/power_supply/bq27000-battery/capacity: Invalid argument Mon Mar 24 14:53:39 UTC 2025 %
cat: /sys/class/power_supply/bq27000-battery/capacity: Invalid argument Mon Mar 24 14:53:40 UTC 2025 %
cat: /sys/class/power_supply/bq27000-battery/capacity: Invalid argument Mon Mar 24 14:53:41 UTC 2025 %
cat: /sys/class/power_supply/bq27000-battery/capacity: Invalid argument Mon Mar 24 14:53:42 UTC 2025 %
Mon Mar 24 14:53:43 UTC 2025 0%
Mon Mar 24 14:53:44 UTC 2025 0%
Mon Mar 24 14:53:45 UTC 2025 0%
Mon Mar 24 14:53:46 UTC 2025 0%
Mon Mar 24 14:53:47 UTC 2025 0%
Mon Mar 24 14:53:48 UTC 2025 0%
Mon Mar 24 14:53:49 UTC 2025 0%
Mon Mar 24 14:53:50 UTC 2025 0%
Mon Mar 24 14:53:51 UTC 2025 0%
Mon Mar 24 14:53:53 UTC 2025 0%

...

Mon Mar 24 15:10:12 UTC 2025 0%
Mon Mar 24 15:10:14 UTC 2025 0%
Mon Mar 24 15:10:15 UTC 2025 0%
--- here device did shut down ---

This means that the capacity can go to 0% for approx. 15 minutes before the BQ27000_FLAG_EDVF becomes set and 0% is reported. I would prefer not to see the EINVAL in between.

This all may end that we have to add another DT property to tell the driver if the bq27xxx is inside a battery or the battery is removeable and only check for value=0 in the latter case?

Or can you limit this logic to the bq27200 because it is unlikely that the i2c variant is used inside a battery pack and the HF08 battery uses the hdq variant?

BR,
Nikolaus

Quoted 57 lines
drivers/power/supply/bq27xxx_battery.c +2 -0
+}
+
 static int bq27xxx_simple_value(int value,
 union power_supply_propval *val)
 {
@@ -2147,6 +2156,8 @@ static int bq27xxx_battery_get_property(struct power_supply *psy,
 ret = bq27xxx_battery_current_and_status(di, val, NULL, NULL);
 break;

case POWER_SUPPLY_PROP_CAPACITY:
+ if (!bq27xxx_value_is_valid(di, di->cache.capacity))
+ return -EINVAL;
ret = bq27xxx_simple_value(di->cache.capacity, val); break;

case POWER_SUPPLY_PROP_CAPACITY_LEVEL:

drivers/power/supply/bq27xxx_battery.c +0 -0
@@ -2157,9 +2168,13 @@ static int bq27xxx_battery_get_property(struct power_supply *psy,
 break;

case POWER_SUPPLY_PROP_TIME_TO_EMPTY_NOW:
ret = bq27xxx_battery_read_time(di, BQ27XXX_REG_TTE, val);
+ if (!ret && !bq27xxx_value_is_valid(di, val->intval))
+ return -EINVAL;
break;
case POWER_SUPPLY_PROP_TIME_TO_EMPTY_AVG:
ret = bq27xxx_battery_read_time(di, BQ27XXX_REG_TTECP, val);
+ if (!ret && !bq27xxx_value_is_valid(di, val->intval))
+ return -EINVAL;
break;
case POWER_SUPPLY_PROP_TIME_TO_FULL_NOW:
ret = bq27xxx_battery_read_time(di, BQ27XXX_REG_TTF, val);

drivers/power/supply/bq27xxx_battery.c +0 -0
@@ -2171,10 +2186,13 @@ static int bq27xxx_battery_get_property(struct power_supply *psy,
 val->intval = POWER_SUPPLY_TECHNOLOGY_LION;
 break;

case POWER_SUPPLY_PROP_CHARGE_NOW:
- if (di->regs[BQ27XXX_REG_NAC] != INVALID_REG_ADDR)
+ if (di->regs[BQ27XXX_REG_NAC] != INVALID_REG_ADDR) { ret = bq27xxx_battery_read_nac(di, val);
- else
+ if (!ret && !bq27xxx_value_is_valid(di, val->intval))
+ return -EINVAL;
+ } else {
ret = bq27xxx_battery_read_rc(di, val);
+ }
break;
case POWER_SUPPLY_PROP_CHARGE_FULL:
ret = bq27xxx_battery_read_fcc(di, val);

drivers/power/supply/bq27xxx_battery.c +0 -0
@@ -2199,6 +2217,8 @@ static int bq27xxx_battery_get_property(struct power_supply *psy,
 break;

case POWER_SUPPLY_PROP_ENERGY_NOW:
ret = bq27xxx_battery_read_energy(di, val);
+ if (!ret && !bq27xxx_value_is_valid(di, val->intval))
+ return -EINVAL;
break;
case POWER_SUPPLY_PROP_POWER_AVG:
ret = bq27xxx_battery_pwr_avg(di, val);

Signature · 1 line
2.49.0
author
#2 lore raw

Hi

Quoted 65 lines

drivers/power/supply/bq27xxx_battery.c static int bq27xxx_battery_read_dmin_volt(struct bq27xxx_device_info *di, · line 2116

Quoted 8 lines
drivers/power/supply/bq27xxx_battery.c +7 -0
+static bool bq27xxx_value_is_valid(struct bq27xxx_device_info *di, int value)
+{
+ /*
+ * On bq27xxx_0_zero, consider zero values invalid if EDVF is not set
+ */
+ return value || !(di->opts & BQ27XXX_O_ZERO) ||
+       (di->cache.flags & BQ27000_FLAG_EDVF);

Hm. This still can return -EINVAL for a valid and successful readout of value == 0 which could happen for a fully drained HF08 in the GTA04 with bq27000.

Here is an excerpt from running a battery until depletion:

root@letux:~# echo off >/sys/class/power_supply/twl4030_usb/mode
root@letux:~# while true; do echo $(date) $(cat /sys/class/power_supply/bq27000-battery/capacity)%; sleep 1; done

Mon Mar 24 14:37:11 UTC 2025 1%
Mon Mar 24 14:37:12 UTC 2025 1%
Mon Mar 24 14:37:13 UTC 2025 1%
...

Mon Mar 24 14:38:24 UTC 2025 1%
Mon Mar 24 14:38:25 UTC 2025 1%
Mon Mar 24 14:38:26 UTC 2025 1%
Mon Mar 24 14:38:27 UTC 2025 1%
cat: /sys/class/power_supply/bq27000-battery/capacity: Invalid argument Mon Mar 24 14:38:28 UTC 2025 %
cat: /sys/class/power_supply/bq27000-battery/capacity: Invalid argument Mon Mar 24 14:38:29 UTC 2025 %
cat: /sys/class/power_supply/bq27000-battery/capacity: Invalid argument Mon Mar 24 14:38:30 UTC 2025 %
cat: /sys/class/power_supply/bq27000-battery/capacity: Invalid argument Mon Mar 24 14:38:32 UTC 2025 %
...
cat: /sys/class/power_supply/bq27000-battery/capacity: Invalid argument Mon Mar 24 14:53:39 UTC 2025 %
cat: /sys/class/power_supply/bq27000-battery/capacity: Invalid argument Mon Mar 24 14:53:40 UTC 2025 %
cat: /sys/class/power_supply/bq27000-battery/capacity: Invalid argument Mon Mar 24 14:53:41 UTC 2025 %
cat: /sys/class/power_supply/bq27000-battery/capacity: Invalid argument Mon Mar 24 14:53:42 UTC 2025 %
Mon Mar 24 14:53:43 UTC 2025 0%
Mon Mar 24 14:53:44 UTC 2025 0%
Mon Mar 24 14:53:45 UTC 2025 0%
Mon Mar 24 14:53:46 UTC 2025 0%
Mon Mar 24 14:53:47 UTC 2025 0%
Mon Mar 24 14:53:48 UTC 2025 0%
Mon Mar 24 14:53:49 UTC 2025 0%
Mon Mar 24 14:53:50 UTC 2025 0%
Mon Mar 24 14:53:51 UTC 2025 0%
Mon Mar 24 14:53:53 UTC 2025 0%

...

Mon Mar 24 15:10:12 UTC 2025 0%
Mon Mar 24 15:10:14 UTC 2025 0%
Mon Mar 24 15:10:15 UTC 2025 0%
--- here device did shut down ---

This means that the capacity can go to 0% for approx. 15 minutes before the BQ27000_FLAG_EDVF becomes set and 0% is reported. I would prefer not to see the EINVAL in between.

Quoted 7 lines

This all may end that we have to add another DT property to tell the driver if the bq27xxx is inside a battery or the battery is removeable and only check for value=0 in the latter case?

Or can you limit this logic to the bq27200 because it is unlikely that the i2c variant is used inside a battery pack and the HF08 battery uses the hdq variant?

I can see the problem. Thanks for testing. Let us retract this patch. I think we can solve the issue in userspace.

Sincerely
Sicelo