hints around rcar_lvds.c :)
Hi Laurent, All,
Sorry for bothering.
Looking for some feedback :)
I have a similar rcar_lvds.c IP's to handle but in my case:
I have lvds0 and lvds1 that are sharing some common regs (lvds_cmn).
----------------------
| ------------- | | |lvds_cmn_regs| | | ------------- | | | | ----------- | | | lvds0_regs | |-----> ch0 | ------------ | | | | ----------- | | | lvds1_regs | |-----> ch1 | ------------ |
----------------------
So I'm checking 2 drm dts/driver architecture:
1st architecture:
- Using a single lvds driver to handle both lvds0 and lvds1.
---------------------- | | | | | | du_lvds0 ------>| |----> ch0_lvds | lvds_bridge | | | | | du_lvds1 ------>| |----> ch1_lvds | | ----------------------
Issue:
Problem here is the 1 single link 2ch mode.
lvds0 and lvds1 can drive 2 display with 2 differents fb (fb0 and fb1).
Having a single drm_bridge to drive both channel give me the following issue:
In single link 2ch mode when for the first time the du encoder drm_attach() the lvds bridge to the encoder(du) all goes fine and fb0 is created correctly.
Then again the du encoder is trying again to drm_attach() the lvds bridge but this return -EBUSY obviously because is already attached.
Then I think this is not the way to follow because I need 2 drm_bridges from the same drm drive, and I think this is not correct.
----------
2nd architecture:
- Follow rcar_lvds.c way using 2 nodes for lvds0 and lvds1:
------------ du_lvds0 -----> |lvds0_bridge|----> ch0_lvds ------------ ------------ du_lvds1 -----> |lvds1_bridge|----> ch1_lvds ------------
Issue:
I thinks this is an optimal approach but in my case here the problem is that lvds0 and lvds1 share a set of common registers some common clocks and common reset:
My plan is to manipulate those common regs (lvds_cmn) using compatible = "simple-mfd", "syscon"; as follow:
lvds_cmn: lvds-cmn {
compatible = "simple-mfd", "syscon";
reg = <common_regs>;
lvds0: lvds0-encoder {
ports {
#address-cells = <1>;
#size-cells = <0>;
clocks = <&common_clk>, <&dotclok0>, <&phyclock0>;
resets = <&common_rst>;
port@0 {
reg = <0>;
lvds0_in: endpoint {
remote-endpoint = <&du_out_lvds0>;
};
};
port@1 {
reg = <1>;
lvds_ch0: endpoint {
};
};
};
};
lvds1: lvds1-encoder {
ports {
#address-cells = <1>;
#size-cells = <0>;
clocks = <&common_clk>, <&dotclok1>, <&phyclock1>;
resets = <&common_rst>;
port@0 {
reg = <0>;
lvds1_in: endpoint {
remote-endpoint = <&du_out_lvds1>;
};
};
port@1 {
reg = <1>;
lvds_ch1: endpoint {
};
};
};
};
};----------
I'm asking to find the best way to represent those IP's. What do you think?
Any hints/tips would be nice.
Thanks in advance.
Thanks & Regards,
Tommaso
+ renesas-soc
Quoted 143 lines
-----Original Message-----
From: dri-devel <[email protected]> On Behalf Of Tommaso Merciai
Sent: 26 November 2024 10:15
To: laurent.pinchart <[email protected]>
Cc: Kieram Bingham <[email protected]>; David Airlie <[email protected]>; Simona Vetter <[email protected]>; [email protected]; [email protected]
Subject: hints aroundrcar_lvds.c:)Hi Laurent, All,
Sorry for bothering.
Looking for some feedback :)I have a similar
rcar_lvds.cIP's to handle but in my case:
I have lvds0 and lvds1 that are sharing some common regs (lvds_cmn).----------------------
| ------------- | | |lvds_cmn_regs| | | ------------- | | | | ----------- | | | lvds0_regs | |-----> ch0 | ------------ | | | | ----------- | | | lvds1_regs | |-----> ch1 | ------------ |----------------------
So I'm checking 2 drm dts/driver architecture:
1st architecture:
- Using a single lvds driver to handle both lvds0 and lvds1.---------------------- | | | | | | du_lvds0 ------>| |----> ch0_lvds | lvds_bridge | | | | | du_lvds1 ------>| |----> ch1_lvds | | ----------------------Issue:
Problem here is the 1 single link 2ch mode.
lvds0 and lvds1 can drive 2 display with 2 differents fb (fb0 and fb1).Having a single
drm_bridgeto drive both channel give me the following issue:In single link 2ch mode when for the first time the du encoder
drm_attach()the lvds bridge to the encoder(du) all goes fine and fb0 is created correctly.Then again the du encoder is trying again to
drm_attach()the lvds bridge but this return-EBUSYobviously because is already attached.Then I think this is not the way to follow because I need 2
drm_bridgesfrom the same drm drive, and I think this is not correct.
----------2nd architecture:
- Followrcar_lvds.cway using 2 nodes for lvds0 and lvds1:------------ du_lvds0 -----> |lvds0_bridge|----> ch0_lvds ------------ ------------ du_lvds1 -----> |lvds1_bridge|----> ch1_lvds ------------Issue:
I thinks this is an optimal approach but in my case here the problem is that lvds0 and lvds1 share a set of common registers some common clocks and common reset:My plan is to manipulate those common regs (
lvds_cmn) using compatible = "simple-mfd", "syscon"; as follow:lvds_cmn: lvds-cmn { compatible = "simple-mfd", "syscon"; reg = <common_regs>; lvds0: lvds0-encoder { ports { #address-cells = <1>; #size-cells = <0>; clocks = <&common_clk>, <&dotclok0>, <&phyclock0>; resets = <&common_rst>; port@0 { reg = <0>; lvds0_in: endpoint { remote-endpoint = <&du_out_lvds0>; }; }; port@1 { reg = <1>; lvds_ch0: endpoint { }; }; }; }; lvds1: lvds1-encoder { ports { #address-cells = <1>; #size-cells = <0>; clocks = <&common_clk>, <&dotclok1>, <&phyclock1>; resets = <&common_rst>; port@0 { reg = <0>; lvds1_in: endpoint { remote-endpoint = <&du_out_lvds1>; }; }; port@1 { reg = <1>; lvds_ch1: endpoint { }; }; }; }; };----------
I'm asking to find the best way to represent those IP's. What do you think?
Any hints/tips would be nice.
Thanks in advance.Thanks & Regards,
Tommaso