nvme native multipath question with two physical paths
Hi All,
In our nvme native multipath support drawer, each nvme has two physical paths/two controllers. We created a shared namespace on it.
# nvme list-ns /dev/nvme2 [ 0]:0x1 # nvme list-ns /dev/nvme6 [ 0]:0x1
# ls -l /dev/nvme2* crw-------. 1 root root 240, 2 Feb 18 18:05 /dev/nvme2 brw-rw----. 1 root disk 259, 4 Feb 18 18:14 /dev/nvme2n1 # ls -l /dev/nvme6* crw-------. 1 root root 240, 6 Feb 18 18:05 /dev/nvme6
nvme-subsys2 - NQN=nqn.1994-11.com.samsung:nvme:PM1735a:2.5-inch:
\
+- nvme2 pcie 052f:80:00.0 live +- nvme6 pcie 058f:80:00.0 live
#nvme list/dev/nvme2n1 /dev/ng2n1
Run stress io test over nvme2n1, we hot unplug nvme2(052f:80:00), /dev/nvme2 controller is gone. /dev/nvme2n1 still existed and io still running over nvme2n1 without error. Looks io test still running over another path(nvme6)bbut we didn’t see /dev/nvme6n1 in /dev dir.
# ls -l /dev/nvme2* brw-rw----. 1 root disk 259, 4 Feb 18 18:22 /dev/nvme2n1 # ls -l /dev/nvme6* crw-------. 1 root root 240, 6 Feb 18 18:05 /dev/nvme6
With nvme native mpath enable,
- What multipath disk name we should use for ANA nvme multipath?
- Why IO still running over nvme2n1 without error even nvme2 controller already unplug?
- Shared namespace is still existed since shared namespace has another controller on it?
- How can let nvme6n1 showing up after nvme2 controller gone.
Thanks for your help!
Wendy
Keith Busch
maintainerQuoted 26 lines · Wen Xiong
Hi All,
In our nvme native multipath support drawer, each nvme has two physical paths/two controllers.
We created a shared namespace on it.# nvme list-ns /dev/nvme2 [ 0]:0x1 # nvme list-ns /dev/nvme6 [ 0]:0x1# ls -l /dev/nvme2* crw-------. 1 root root 240, 2 Feb 18 18:05 /dev/nvme2 brw-rw----. 1 root disk 259, 4 Feb 18 18:14 /dev/nvme2n1 # ls -l /dev/nvme6* crw-------. 1 root root 240, 6 Feb 18 18:05 /dev/nvme6nvme-subsys2 - NQN=nqn.1994-11.com.samsung:nvme:PM1735a:2.5-inch:
\+- nvme2 pcie 052f:80:00.0 live +- nvme6 pcie 058f:80:00.0 live#nvme list
/dev/nvme2n1/dev/ng2n1
Quoted 5 lines
Run stress io test over nvme2n1, we hot unplug nvme2(052f:80:00),
/dev/nvme2controller is gone./dev/nvme2n1still existed and io still running over nvme2n1 without error. Looks io test still
running over another path(nvme6)bbut we didn´t see/dev/nvme6n1in /dev dir.
Nor should you see a /dev/nvme6n1 in this scenario. The mulitpath device doesn't change names. It assumes the identifier from the subsystem. In your example, it uses subsystem '2' and will continue to use it no matter which controller instances are attach to it. This feature is why applications that have opened the /dev/nvme2n1 handle don't need to do anything if the kernel experiences a path failover condition.
You should see the different paths in the hidden block hierarchy, which you can find in the sysfs directory. There should be an entry in your example at /sys/block/nvme2c6n1/. I am pretty sure programs like 'iostat' can show how IO is distributed among all the paths of an nvme mulitpath device.
Quoted 7 lines · Keith Busch
Nor should you see a
/dev/nvme6n1in this scenario. The mulitpath device doesn't change names. It assumes the identifier from the subsystem. In your example, it uses subsystem '2' and will continue to use it no matter which controller instances are attach to it. This feature is why applications that have opened the/dev/nvme2n1handle don't need to do anything if the kernel experiences a path failover condition.
Quoted 5 lines
You should see the different paths in the hidden block hierarchy, which you can find in the sysfs directory. There should be an entry in your example at
/sys/block/nvme2c6n1/. I am pretty sure programs like 'iostat' can show how IO is distributed among all the paths of an nvme mulitpath device.
Hi Ketith,
Thanks for your detail explanation!