Skip to contentSkip to conversation

ARM: dts: imx7: remove DSI port endpoints

PATCH Applied Francesco Dolcini 2 participants 3 messages Feb 16, 2024 – Feb 25, 2024

Subsystems (2)
lore
Share & tools
lore
#0 lore raw

PATCH 1/1 ARM: dts: imx7: remove DSI port endpoints

From: Francesco Dolcini <[email protected]>

This fixes the display not working on colibri imx7, the driver fails to load with the following error:

mxsfb 30730000.lcdif: error -ENODEV: Cannot connect bridge

NXP i.MX7 LCDIF is connected to both the Parallel LCD Display and to a MIPI DSI IP block, currently it's not possible to describe the connection to both.

Remove the port endpoint from the SOC dtsi to prevent regressions, this would need to be defined on the board DTS.

---
 arch/arm/boot/dts/nxp/imx/imx7s.dtsi | 26 --------------------------
 1 file changed, 26 deletions(-)
arch/arm/boot/dts/nxp/imx/imx7s.dtsi +0 -26
index ebf7befcc11e..9c81c6baa2d3 100644
@@ -834,16 +834,6 @@ lcdif: lcdif@30730000 {
 					<&clks IMX7D_LCDIF_PIXEL_ROOT_CLK>;
 				clock-names = "pix", "axi";
 				status = "disabled";
-
-				port {
-					#address-cells = <1>;
-					#size-cells = <0>;
-
-					lcdif_out_mipi_dsi: endpoint@0 {
-						reg = <0>;
-						remote-endpoint = <&mipi_dsi_in_lcdif>;
-					};
-				};
 			};
 
 			mipi_csi: mipi-csi@30750000 {
@@ -895,22 +885,6 @@ mipi_dsi: dsi@30760000 {
 				samsung,esc-clock-frequency = <20000000>;
 				samsung,pll-clock-frequency = <24000000>;
 				status = "disabled";
-
-				ports {
-					#address-cells = <1>;
-					#size-cells = <0>;
-
-					port@0 {
-						reg = <0>;
-						#address-cells = <1>;
-						#size-cells = <0>;
-
-						mipi_dsi_in_lcdif: endpoint@0 {
-							reg = <0>;
-							remote-endpoint = <&lcdif_out_mipi_dsi>;
-						};
-					};
-				};
 			};
 		};
 
Signature · 1 line
2.39.2
#1 lore raw
Quoted 11 lines · Francesco Dolcini

From: Francesco Dolcini <[email protected]>

This fixes the display not working on colibri imx7, the driver fails to load with the following error:

mxsfb 30730000.lcdif: error -ENODEV: Cannot connect bridge

NXP i.MX7 LCDIF is connected to both the Parallel LCD Display and to a MIPI DSI IP block, currently it's not possible to describe the connection to both.

Quoted 7 lines

Remove the port endpoint from the SOC dtsi to prevent regressions, this would need to be defined on the board DTS.

Hello Shawn, what do you plan to do with this?

This fixes a regression from v6.8-rc1 and would be nice to have it into the final v6.8.

Francesco

Applied
#2 lore raw
Quoted 20 lines · Francesco Dolcini
Quoted 11 lines · Francesco Dolcini

From: Francesco Dolcini <[email protected]>

This fixes the display not working on colibri imx7, the driver fails to load with the following error:

mxsfb 30730000.lcdif: error -ENODEV: Cannot connect bridge

NXP i.MX7 LCDIF is connected to both the Parallel LCD Display and to a MIPI DSI IP block, currently it's not possible to describe the connection to both.

Quoted 7 lines

Remove the port endpoint from the SOC dtsi to prevent regressions, this would need to be defined on the board DTS.

Quoted 4 lines

Hello Shawn, what do you plan to do with this?

This fixes a regression from v6.8-rc1 and would be nice to have it into the final v6.8.

Applied as a fix for 6.8, thanks!