dt-bindings: input: Goodix SPI HID Touchscreen
Subsystems (3)
PATCH v2 1/1 dt-bindings: input: Goodix SPI HID Touchscreen
The Goodix GT7986U touch controller report touch data according to the HID protocol through the SPI bus. However, it is incompatible with Microsoft's HID-over-SPI protocol.
---
Changes in v2:
- Change compatible to 'goodix,gt7986u-spifw'.
- Remove 'goodix,hid-report-addr' property.
- Change additionalProperties to unevaluatedProperties.
- v1: https://lore.kernel.org/all/[email protected]/
--- .../bindings/input/goodix,gt7986u.yaml | 66 +++++++++++++++++++ 1 file changed, 66 insertions(+) create mode 100644 Documentation/devicetree/bindings/input/goodix,gt7986u.yaml
Documentation/devicetree/bindings/input/goodix,gt7986u.yaml new file +66 -0
@@ -0,0 +1,66 @@ +# SPDX-License-Identifier: (GPL-2.0-only OR BSD-2-Clause) +%YAML 1.2 +--- +$id: http://devicetree.org/schemas/input/goodix,gt7986u.yaml# +$schema: http://devicetree.org/meta-schemas/core.yaml# + +title: Goodix GT7986U SPI HID Touchscreen + +maintainers: + - Charles Wang <[email protected]> + +description: Supports the Goodix GT7986U touchscreen. + This touch controller reports data packaged according to the HID protocol + over the SPI bus, but it is incompatible with Microsoft's HID-over-SPI protocol. + +allOf: + - $ref: /schemas/spi/spi-peripheral-props.yaml# + +properties: + compatible: + description: + Add the 'spifw' suffix to distinguish it from the general GT7986U I2C-HID + touchscreen, as it runs a substantially different firmware than GT7986U + I2C-HID touchscreens. + enum: + - goodix,gt7986u-spifw + + reg: + maxItems: 1 + + interrupts: + maxItems: 1 + + reset-gpios: + maxItems: 1 + + spi-max-frequency: true + +unevaluatedProperties: false + +required: + - compatible + - reg + - interrupts + - reset-gpios + +examples: + - | + #include <dt-bindings/interrupt-controller/irq.h> + #include <dt-bindings/gpio/gpio.h> + + spi { + #address-cells = <1>; + #size-cells = <0>; + + touchscreen@0 { + compatible = "goodix,gt7986u-spifw"; + reg = <0>; + interrupt-parent = <&gpio>; + interrupts = <25 IRQ_TYPE_LEVEL_LOW>; + reset-gpios = <&gpio1 1 GPIO_ACTIVE_LOW>; + spi-max-frequency = <10000000>; + }; + }; + +...
Signature · 1 line
2.43.0
Hi,
Quoted 4 lines · Charles Wang
The Goodix GT7986U touch controller report touch data according to the HID protocol through the SPI bus. However, it is incompatible with Microsoft's HID-over-SPI protocol.
I think it was requested that both the yaml file and the commit message mention why there are two different yaml file that both talk about "gt7986u". In the commit message I think it would be valuable to point to the previous discussion. AKA, maybe say:
NOTE: these bindings are distinct from the bindings used with the GT7986U when the chip is running I2C firmware. For some background, see discussion on the mailing lists in the thread:
https://lore.kernel.org/r/[email protected]
Quoted 5 lines
Signed-off-by Charles Wang <[email protected]>---
Changes in v2:
- Change compatible to 'goodix,gt7986u-spifw'.
- Remove 'goodix,hid-report-addr' property.
Probably this should be a two-patch series now. The first is this bindings file and the second changes the firmware (which never got reverted) to default to a hid-report-addr of 1.
Quoted 6 lines
- Change additionalProperties to unevaluatedProperties.
- v1: https://lore.kernel.org/all/[email protected]/--- .../bindings/input/goodix,gt7986u.yaml | 66 +++++++++++++++++++ 1 file changed, 66 insertions(+) create mode 100644 Documentation/devicetree/bindings/input/goodix,gt7986u.yaml
The name of the file needs to match the primary compatible, so it should include the "-spifw" part.
Quoted 10 lines
Documentation/devicetree/bindings/input/goodix,gt7986u.yaml new file +4
-0@@ -0,0 +1,66 @@ +# SPDX-License-Identifier: (GPL-2.0-only OR BSD-2-Clause) +%YAML 1.2 +--- +$id: http://devicetree.org/schemas/input/goodix,gt7986u.yaml#
Documentation/devicetree/bindings/input/goodix,gt7986u.yaml line 14
Quoted 10 lines
Documentation/devicetree/bindings/input/goodix,gt7986u.yaml new file +10
-0+$schema: http://devicetree.org/meta-schemas/core.yaml# + +title: Goodix GT7986U SPI HID Touchscreen + +maintainers: + - Charles Wang <[email protected]> + +description: Supports the Goodix GT7986U touchscreen. + This touch controller reports data packaged according to the HID protocol + over the SPI bus, but it is incompatible with Microsoft's HID-over-SPI protocol.
I probably would have put the note about the compatible here instead of below. Something like:
NOTE: these bindings are distinct from the bindings used with the GT7986U when the chip is running I2C firmware. This is because there's not a single device that talks over both I2C and SPI but rather distinct touchscreens that happen to be built with the same ASIC but that are distinct products running distinct firmware.
Documentation/devicetree/bindings/input/goodix,gt7986u.yaml line 24
Quoted 9 lines
Documentation/devicetree/bindings/input/goodix,gt7986u.yaml new file +9
-0+allOf: + - $ref: /schemas/spi/spi-peripheral-props.yaml# + +properties: + compatible: + description: + Add the 'spifw' suffix to distinguish it from the general GT7986U I2C-HID + touchscreen, as it runs a substantially different firmware than GT7986U + I2C-HID touchscreens.
As per above, I'd remove the "description" here. It's not common for a compatible to have a "description".
Quoted 5 lines
Documentation/devicetree/bindings/input/goodix,gt7986u.yaml new file +5
-0+ enum: + - goodix,gt7986u-spifw + + reg: + maxItems: 1
Documentation/devicetree/bindings/input/goodix,gt7986u.yaml line 39
Quoted 10 lines
Documentation/devicetree/bindings/input/goodix,gt7986u.yaml new file +10
-0+ + interrupts: + maxItems: 1 + + reset-gpios: + maxItems: 1 + + spi-max-frequency: true + +unevaluatedProperties: false
I believe "unevaluatedProperties" is supposed to be moved down below "required" according to previous comments on your patches.
Quoted 13 lines · Doug Anderson
Hi,
Quoted 4 lines · Charles Wang
The Goodix GT7986U touch controller report touch data according to the HID protocol through the SPI bus. However, it is incompatible with Microsoft's HID-over-SPI protocol.
I think it was requested that both the yaml file and the commit message mention why there are two different yaml file that both talk about "gt7986u". In the commit message I think it would be valuable to point to the previous discussion. AKA, maybe say:
Quoted 6 lines
NOTE: these bindings are distinct from the bindings used with the GT7986U when the chip is running I2C firmware. For some background, see discussion on the mailing lists in the thread:
Ack,
Quoted 11 lines
Quoted 6 lines
Signed-off-by Charles Wang <[email protected]>---
Changes in v2:
- Change compatible to 'goodix,gt7986u-spifw'.
- Remove 'goodix,hid-report-addr' property.Probably this should be a two-patch series now. The first is this bindings file and the second changes the firmware (which never got reverted) to default to a hid-report-addr of 1.
Ack,
Quoted 11 lines
Quoted 7 lines
- Change additionalProperties to unevaluatedProperties.
- v1: https://lore.kernel.org/all/[email protected]/--- .../bindings/input/goodix,gt7986u.yaml | 66 +++++++++++++++++++ 1 file changed, 66 insertions(+) create mode 100644 Documentation/devicetree/bindings/input/goodix,gt7986u.yamlThe name of the file needs to match the primary compatible, so it should include the "-spifw" part.
Ack,
Quoted 25 lines
Quoted 11 lines
Documentation/devicetree/bindings/input/goodix,gt7986u.yaml new file +4
-0@@ -0,0 +1,66 @@ +# SPDX-License-Identifier: (GPL-2.0-only OR BSD-2-Clause) +%YAML 1.2 +--- +$id: http://devicetree.org/schemas/input/goodix,gt7986u.yaml#Documentation/devicetree/bindings/input/goodix,gt7986u.yaml line 14
Quoted 10 lines
Documentation/devicetree/bindings/input/goodix,gt7986u.yaml new file +10
-0+$schema: http://devicetree.org/meta-schemas/core.yaml# + +title: Goodix GT7986U SPI HID Touchscreen + +maintainers: + - Charles Wang <[email protected]> + +description: Supports the Goodix GT7986U touchscreen. + This touch controller reports data packaged according to the HID protocol + over the SPI bus, but it is incompatible with Microsoft's HID-over-SPI protocol.I probably would have put the note about the compatible here instead of below. Something like:
Quoted 6 lines
NOTE: these bindings are distinct from the bindings used with the GT7986U when the chip is running I2C firmware. This is because there's not a single device that talks over both I2C and SPI but rather distinct touchscreens that happen to be built with the same ASIC but that are distinct products running distinct firmware.
Ack,
Quoted 14 lines
Documentation/devicetree/bindings/input/goodix,gt7986u.yaml line 24
Quoted 10 lines
Documentation/devicetree/bindings/input/goodix,gt7986u.yaml new file +9
-0+allOf: + - $ref: /schemas/spi/spi-peripheral-props.yaml# + +properties: + compatible: + description: + Add the 'spifw' suffix to distinguish it from the general GT7986U I2C-HID + touchscreen, as it runs a substantially different firmware than GT7986U + I2C-HID touchscreens.As per above, I'd remove the "description" here. It's not common for a compatible to have a "description".
Ack,
Quoted 11 lines
Quoted 11 lines
Documentation/devicetree/bindings/input/goodix,gt7986u.yaml new file +10
-0+ enum: + - goodix,gt7986u-spifw + + reg: + maxItems: 1 + + interrupts: + maxItems: 1 + + reset-gpios:
Quoted 8 lines
Documentation/devicetree/bindings/input/goodix,gt7986u.yaml line 39
Quoted 5 lines
Documentation/devicetree/bindings/input/goodix,gt7986u.yaml new file +5
-0+ maxItems: 1 + + spi-max-frequency: true + +unevaluatedProperties: falseI believe "unevaluatedProperties" is supposed to be moved down below "required" according to previous comments on your patches.
Ack,
Thank you very much,
Charles