regulator: core: fix constraints handling if current state out of range
RFC PATCH 1/1 regulator: core: fix constraints handling if current state out of range
Given a regulator set to an initially out of constraints value, which cannot be set to the exact voltage given in the min or max constraints, current code tries to apply a fixed value which obviously fails.
To fix that, allow a range as a constraint in out of bound cases.
A practical use case for this scenario is if there is a quotient in uV_step which needs to get rounded.
The devicetree should describe the hardware and not depend on the idea of a specific driver implementation how to round things, so a small range need to be specified.
Instead of rounding uV_step another user of the devicetree might be specifying uV_max and uV_min and therefore only needs to round the end result leading to slightly different results.
Stumbled upon it while creating a regulator with uV_step = 5000000 / 255
---
not tested yet to avoid magic smoke in case of errors. I rather prefer having a second pair of eyes on it in this sensitive area.
--- drivers/regulator/core.c | 8 ++------ 1 file changed, 2 insertions(+), 6 deletions(-)
drivers/regulator/core.c +2 -6
@@ -1238,13 +1238,9 @@ static int machine_constraints_voltage(struct regulator_dev *rdev, target_min = current_uV; target_max = current_uV; -if (current_uV < rdev->constraints->min_uV) { +if ((current_uV < rdev->constraints->min_uV) || + (current_uV > rdev->constraints->max_uV)) { target_min = rdev->constraints->min_uV; - target_max = rdev->constraints->min_uV; - } - -if (current_uV > rdev->constraints->max_uV) { - target_min = rdev->constraints->max_uV; target_max = rdev->constraints->max_uV; }
---
base-commit: dcb6fa37fd7bc9c3d2b066329b0d27dedf8becaa
change-id: 20251103-regu-fix-d650274afa89
Best regards,
Signature · 1 line
Andreas Kemnade <[email protected]>
Mark Brown
maintainerdrivers/regulator/core.c static int machine_constraints_voltage(struct regulator_dev *rdev, · line 1245
Quoted 11 lines · Andreas Kemnade
drivers/regulator/core.c +2
-6-if (current_uV < rdev->constraints->min_uV) { +if ((current_uV < rdev->constraints->min_uV) || + (current_uV > rdev->constraints->max_uV)) { target_min = rdev->constraints->min_uV; - target_max = rdev->constraints->min_uV; - } - -if (current_uV > rdev->constraints->max_uV) { - target_min = rdev->constraints->max_uV; target_max = rdev->constraints->max_uV; }
There's a valid issue here if we can't represent the exact constraint (the hope was that people wouldn't specify constraints that their hardware wasn't capable of representing but we can't exactly stop them...) however this change is risky in the case where the voltage is too high since if we specify a range from minimum to maximum we'll try to select a voltage as close as possible to the minimum. That could result in a large change if the range is wide, and potentially go under the voltage the hardware needs for it's current configuration. We were trying to set the highest voltage in the range to minimise the risk there. This isn't a concern in the case where we're raising the voltage.
Quoted 17 lines · On Tue, 4 Nov 2025 13:52:11 +0000 Mark Brown <[email protected]> wrote:
drivers/regulator/core.c static int machine_constraints_voltage(struct regulator_dev *rdev, · line 1245
Quoted 11 lines · Andreas Kemnade
drivers/regulator/core.c +2
-6-if (current_uV < rdev->constraints->min_uV) { +if ((current_uV < rdev->constraints->min_uV) || + (current_uV > rdev->constraints->max_uV)) { target_min = rdev->constraints->min_uV; - target_max = rdev->constraints->min_uV; - } - -if (current_uV > rdev->constraints->max_uV) { - target_min = rdev->constraints->max_uV; target_max = rdev->constraints->max_uV; }There's a valid issue here if we can't represent the exact constraint (the hope was that people wouldn't specify constraints that their hardware wasn't capable of representing but we can't exactly stop
Quoted 8 lines
them...) however this change is risky in the case where the voltage is too high since if we specify a range from minimum to maximum we'll try to select a voltage as close as possible to the minimum. That could result in a large change if the range is wide, and potentially go under the voltage the hardware needs for it's current configuration. We were trying to set the highest voltage in the range to minimise the risk there. This isn't a concern in the case where we're raising the voltage.
So basically you do not trust the constrains too much (which is understandable) and think that
a voltage near the boot default is the safest one.
As a hw engineer I would first try to wire things to regulators having useable defaults (in that case a too wide range does not harm, because voltage is ok). As a second choice I would use a regulator being off per default which needs to be configured to a safe voltage. Then of course ranges matter, but IHMO there is no indication which voltage in the range is the safest one.
But again, this change is dangerous. maybe another tag like regulator-prefer-low/high might be interesting.
Having to specify odd values with more than 1 ppm precision for a regulator with maybe 1 percent precision is also ugly. So the only improvement possible is to find the nearest possible voltage via list_voltages() still matching the constraints.
Regards,
Andreas
Mark Brown
maintainerQuoted 10 lines · Andreas Kemnade
Quoted 4 lines · Mark Brown
There's a valid issue here if we can't represent the exact constraint (the hope was that people wouldn't specify constraints that their hardware wasn't capable of representing but we can't exactly stop them...) however this change is risky in the case where the voltage is
So basically you do not trust the constrains too much (which is understandable) and think that
a voltage near the boot default is the safest one.
Well, the problem is that the constraints need to be combined with the current operating state for the hardware and at the point where we're applying configuration from the constraints for the first time drivers haven't had a chance to start so we don't really know what state the hardware is in - we might be running at a high operating point, or have some device that needs the upper end of the voltage range powered up and doing something we need. Ideally the hardware would come to us in a state matching the constraints so we just don't need to do anything.
Quoted 4 lines
Having to specify odd values with more than 1 ppm precision for a regulator with maybe 1 percent precision is also ugly. So the only improvement possible is to find the nearest possible voltage via
list_voltages()still matching the constraints.
Yes, I think that's the only safe thing to do. For the lower voltage that's just a normal voltage set, but for the upper it'd be new.