drm/panel: tdo-tl070wsh30: Use mipi_dsi_*_multi() functions
A message that is not in the archive (sent off-list or not yet received): [email protected]
Quoted 11 lines · On Sat, Jul 25, 2026 at 05:01:33PM +0000, [email protected] wrote:
[Severity: High]
Does returning early here on a DSI transmission error leave the panel in an unrecoverable state?Because
panel->preparedis never set to false on error, a subsequent call todrm_panel_prepare()will immediately return 0 without re-running the hardware initialization sequence, leaving the display permanently blank until a system reboot.Could we unconditionally disable the regulator and return 0 here to ensure the state machine remains synchronized, even if there are DSI errors?
Agreed, and this is the alternative I raised below the cut in this patch.
Unless anyone objects, I will send a v2 that disables the regulator unconditionally and returns 0.
Sashiko AI review: https://sashiko.dev/#/patchset/[email protected]?part=1
Signature · 2 lines
Thanks, Akash