RFC PATCH 1/1 net: pse-pd: Don't be a regulator provider
Commit ffef61d6d273 ("net: pse-pd: Add support for budget evaluation strategies") introduced an unusual regulator usecase- that is, a device that's both a consumer and provider of the same regulator: every PI is registered as a regulator whose "vpwr" supply is also requested by the PSE core for the power domain.
This ended up causing a significant amount of complication for the PSE core, and can result in an ABBA deadlock that lockdep doesn't see. The deadlock can happen when PSE ops are running concurrent with the pse_isr, and I noticed it when a PoE port is enabled via ethtool and that PoE port has a device that is ready to be powered.
- As a regulator provider, PSE's ops (is_enabled, enable, disable, ...)
take pcdev->lock while the core already holds the regulator lock
(regulator lock -> pcdev->lock). - As a consumer of the power-budget API, pse_isr(), pse_ethtool_set_pw_limit() and pse_ethtool_set_prio() call regulator_request/free_power_budget() (which take the supply's regulator lock) while holding pcdev->lock, from contexts that are not regulator callbacks (pcdev->lock -> regulator lock).
And this can deadlock because the locking order between pcdev->lock and the regulator lock is inverted in the two paths.
Lockdep doesn't flag this deadlock because regulator_lock_nested() takes the lock via ww_mutex_trylock(), and apparently lockdep doesn't record a dependency for a trylock. However, if the trylock is adjusted to always block, lockdep does report the ordering violation.
One way to fix this complication is to not register a regulator provider per PI and reduce the pse_core's usage to only be a regulator consumer. The regulator core used to provide some behaviour as a side effect of the PI regulator, which the PSE core now does itself:
- Enabling a PI enabled its "vpwr" supply, and a PI found enabled when its control was acquired took a reference on it. Each PI now tracks whether it holds an enable reference on the power domain supply.
- The "vpwr" supply was resolved from the PI node, then from the controller node. It is now requested with of_regulator_get() from the same nodes, and power domains are matched on the provider node rather than with regulator_is_equal(). Consequently, PSE_CONTROLLER now depends on OF.
- A supply whose provider has not registered yet still leaves the PI without a power domain, as before. pse_control_get() used to return -EPROBE_DEFER until that supply resolved, since getting the PI regulator resolved its supply; it now succeeds right away.
- A failing hardware disable is still not reported, and the supply reference is still released, as the regulator disable callback did.
- A failing regulator_disable() of the supply is not retried, as with the regulator devres helpers: the regulator core may already have dropped the consumer's enable reference when it reports the error.
User visible changes:
- pse_ethtool_set_pw_limit() hands the limit in mW straight to pi_set_pw_limit(). A controller without pi_set_pw_limit() now returns -EOPNOTSUPP, where it used to return -EPERM once the PI voltage had been read.
- The PI regulators no longer show up in the regulator sysfs and debugfs, and over-current and over-temperature events are no longer sent on a regulator notifier chain. The ethtool notifications are unchanged.
---
RFC: I'm posting this RFC to discuss how the ABBA deadlock in the PSE core should be fixed. The deadlock was pointed out by Sashiko in [1], and I've hit it in testing [2]:
Quoted 8 lines
This isn't a bug introduced by this patch, but choosing the static budget strategy exposes a lock ordering problem that already exists in the PSE core.
pse_isr()holdspcdev->lockand ends up taking the supply regulator lock [...] An admin enable running at the same time takes the locks in the opposite order [...] Theww_mutexscheme cannot break a cycle that includes the plainpcdev->lockmutex.
With no PI regulator, nothing takes pcdev->lock from inside a regulator callback, so only the pcdev->lock -> regulator lock order remains.
This RFC is one approach of probably several possible ways to fix the deadlock. That said, after exploring this approach, I've found several other problems others have hit in their drivers on the list get fixed as a result:
Setting a power limit on an unpowered port fails
------------------------------------------------
The core needs a port voltage to turn mW into uA for the regulator API [3]:
Quoted 2 lines
netlink error: Can't calculate the current, PSE voltage read is 0 netlink error: Result not representable
Kory's suggestion was that pi_get_voltage should not return 0 [4]:
Quoted 2 lines
To have this working the
pi_get_voltageshould return some value even with no PD plugged.
The Realtek PSE MCU driver already works around it this way [5]:
Quoted 3 lines
core: return constant voltage when MCU reports zero, in case the port is not delivering. This avoids "Voltage null" errors in case a power limit is set while port is not delivering (Sashiko)
The limit is now handed to pi_set_pw_limit() in mW, so no voltage is needed and pi_get_voltage has no remaining user in the core.
Overflow and precision loss in the mW -> uA -> mW conversion
------------------------------------------------------------
The conversion can overflow on drivers that report a measured voltage [6]:
Quoted 4 lines
For the largest allowed limit, 99900 mW, that overflows below about 46.5 mV. Only 0 V is rejected, and si3474 reports the measured voltage of each port. A negative result then hits the
BUG_ON()inregulator_check_current_limit().
The conversion is removed, along with pse_pi_get_current_limit(), so the possibility of losing precision on the way back to mW is gone too.
Use-after-free in the PI regulator ops
--------------------------------------
The PI regulator ops can run after the PI array is freed [7]:
Quoted 4 lines
When
regulator_unregister()flushes a pending disable, the regulator core invokespse_pi_disable(), which dereferences pcdev->pi[id] [...] At that point the PI array is already freed, so this is a use-after-free.
The PI regulator and its ops are removed.
Regulator enable count out of step after a failed disable
---------------------------------------------------------
pse_pi_disable() always returns 0, so the regulator's enable count gets out of step with the PI state after a failed disable [8]:
Quoted 3 lines
a further disable attempt calls
regulator_disable()withuse_count== 0, which the regulator core rejects with a WARN and-EIO.
Each PI now tracks its own enable reference on the power domain supply. A failed hardware disable is still not reported, as before.
PI lookups returning -EPROBE_DEFER after registration
-----------------------------------------------------
PI lookups can keep returning -EPROBE_DEFER after the controller has registered, because pse_control_get() goes through the PI regulator [9]:
Quoted 6 lines
A PI lookup in that window still returns -EPROBE_DEFER:
pse_control_get_internal()
regulator_get_exclusive()
_regulator_get_common()
regulator_resolve_supply()
pse_control_get() no longer gets a regulator. A PI whose supply has not registered yet is still left without a power domain, as before.
Power domain matching
---------------------
Power domains are now matched on the provider's DT node instead of regulator_is_equal() on the rdev->supply.
Drawbacks
---------
Maybe some drawbacks of the approach (but I'm biased, so hopefully others can point out more severe problems):
* PI regulators are dropped from sysfs/debugfs
* There is now a hard dependency on OF. I'm not sure if this matters, since there's not a PSE driver with ACPI match tables in the tree. Perhaps if one is added, the supply lookup can be reworked at that point.
The broader trade-off of dropping the PI regulator was discussed in [10], [11] and [12].
Finally, while this is fixing a deadlock I've hit pretty often in testing, and has a "Fixes" tag, to me it's adjusting an intentional design point of the PSE core, which implies it's a new change. I don't have a preference either way, and it doesn't matter for RFC.
[1] https://lore.kernel.org/netdev/[email protected]/
[2] https://lore.kernel.org/netdev/asM8rcKC1n1Tn4JD@est-xps15/
[3] https://lore.kernel.org/netdev/[email protected]/
[4] https://lore.kernel.org/netdev/[email protected]/
[5] https://lore.kernel.org/netdev/[email protected]/
[6] https://lore.kernel.org/netdev/[email protected]/
[7] https://lore.kernel.org/netdev/[email protected]/
[8] https://lore.kernel.org/netdev/[email protected]/
[9] https://lore.kernel.org/netdev/[email protected]/
[10] https://lore.kernel.org/netdev/[email protected]/
[11] https://lore.kernel.org/netdev/[email protected]/
[12] https://lore.kernel.org/netdev/[email protected]/
--- drivers/net/pse-pd/Kconfig | 1 + drivers/net/pse-pd/pse_core.c | 653 ++++++++++++++++++++---------------------- include/linux/pse-pd/pse.h | 5 +- 3 files changed, 320 insertions(+), 339 deletions(-)
drivers/net/pse-pd/Kconfig +1 -0
@@ -4,10 +4,11 @@ # menuconfig PSE_CONTROLLER bool "Ethernet Power Sourcing Equipment Support" depends on REGULATOR + depends on OF help Generic Power Sourcing Equipment Controller support. If unsure, say no.
drivers/net/pse-pd/pse_core.c +317 -336
965 lines not on this page · raw message
include/linux/pse-pd/pse.h +2 -3
@@ -8,11 +8,10 @@#include <linux/list.h> #include <linux/netlink.h> #include <linux/kfifo.h> #include <uapi/linux/ethtool.h> #include <uapi/linux/ethtool_netlink_generated.h> -#include <linux/regulator/driver.h> /* Maximum current in uA according to IEEE 802.3-2022 Table 145-1 */ #define MAX_PI_CURRENT 1920000/* Maximum power in mW according to IEEE 802.3-2022 Table 145-16 */ #define MAX_PI_PW 99900
@@ -242,12 +241,12 @@ struct pse_pi_pairset {* struct pse_pi - PSE PI (Power Interface) entity as described in * IEEE 802.3-2022 145.2.4 * * @pairset: table of the PSE PI pinout alternative for the two pairset * @np: device node pointer of the PSE PI node -* @rdev: regulator represented by the PSE PI * @admin_state_enabled: PI enabled state +* @supply_enabled: PI holds an enable reference on its power domain supply * @pw_d: Power domain of the PSE PI * @prio: Priority of the PSE PI. Used in static budget evaluation strategy * @isr_pd_detected: PSE PI detection status managed by the interruption * handler. This variable is relevant when the power enabled * management is managed in software like the static
@@ -256,12 +255,12 @@ struct pse_pi_pairset {* static budget evaluation strategy. */ struct pse_pi {struct pse_pi_pairset pairset[2 ];struct device_node *np; -struct regulator_dev *rdev;bool admin_state_enabled; +bool supply_enabled;struct pse_power_domain *pw_d;int prio;bool isr_pd_detected;int pw_allocated_mW; };
---
base-commit: 8cc24527d54d3ecaa09eec5a91bd107bb8b3d7d3
change-id: 20261020-pse_regulator_fixes-a16bfb0f90f6
Best regards,
Signature · 1 line
Kyle Swenson <[email protected]>
Kory Maincent
maintainerThanks you for this work!
Quoted 5 lines · Kyle Swenson
Commit
ffef61d6d273("net: pse-pd: Add support for budget evaluation strategies") introduced an unusual regulator usecase- that is, a device that's both a consumer and provider of the same regulator: every PI is registered as a regulator whose "vpwr" supply is also requested by the PSE core for the power domain.
The unusual usecase was not introduced in that commit but in the initial support for PoE. With Oleksij, we initially thought that a PSE PI is something providing power therefore it look like a regulator provider behavior. In that case if we nest PSE PI and the regulator framework, the featured added for the PSE PIs could improve regulator framework and feature already supported by the regulator could be useful for the PSE PI case. Due to this idea, we had nested the frameworks and each PSE PI register a regulator provider. The thing is that there is no device that could represent the regulator consumer, the real device is the PD plugged on the Ethernet port but it is not represented by the software. Finally we end up with this unusual usecase to have each PSE PIs to be a regulator provider and its own consumer.
However along the development no advantage of using such usecase appeared except for the power budget, but it is different because it is related to the PSE PI supply parent not the PI itself. This is the "vpwr" supply described in the binding. This usecase was for now, only adding code complexity, function wrapper, and several deadlock issues as you have described below.
Quoted 58 lines
This ended up causing a significant amount of complication for the PSE core, and can result in an ABBA deadlock that lockdep doesn't see. The deadlock can happen when PSE ops are running concurrent with the
pse_isr, and I noticed it when a PoE port is enabled via ethtool and that PoE port has a device that is ready to be powered.- As a regulator provider, PSE's ops (
is_enabled, enable, disable, ...)take pcdev->lock while the core already holds the regulator lock (regulator lock -> pcdev->lock).- As a consumer of the power-budget API,
pse_isr(),pse_ethtool_set_pw_limit()andpse_ethtool_set_prio()call regulator_request/free_power_budget() (which take the supply's regulator lock) while holdingpcdev->lock, from contexts that are not regulator callbacks (pcdev->lock-> regulator lock).And this can deadlock because the locking order between
pcdev->lockand the regulator lock is inverted in the two paths.Lockdep doesn't flag this deadlock because
regulator_lock_nested()takes the lock viaww_mutex_trylock(), and apparently lockdep doesn't record a dependency for a trylock. However, if the trylock is adjusted to always block, lockdep does report the ordering violation.One way to fix this complication is to not register a regulator provider per PI and reduce the pse_core's usage to only be a regulator consumer. The regulator core used to provide some behaviour as a side effect of the PI regulator, which the PSE core now does itself:
- Enabling a PI enabled its "vpwr" supply, and a PI found enabled when its control was acquired took a reference on it. Each PI now tracks whether it holds an enable reference on the power domain supply.
- The "vpwr" supply was resolved from the PI node, then from the controller node. It is now requested with
of_regulator_get()from the same nodes, and power domains are matched on the provider node rather than withregulator_is_equal(). Consequently,PSE_CONTROLLERnow depends on OF.- A supply whose provider has not registered yet still leaves the PI without a power domain, as before.
pse_control_get()used to return -EPROBE_DEFER until that supply resolved, since getting the PI regulator resolved its supply; it now succeeds right away.- A failing hardware disable is still not reported, and the supply reference is still released, as the regulator disable callback did.
- A failing
regulator_disable()of the supply is not retried, as with the regulator devres helpers: the regulator core may already have dropped the consumer's enable reference when it reports the error.User visible changes:
-
pse_ethtool_set_pw_limit()hands the limit in mW straight topi_set_pw_limit(). A controller withoutpi_set_pw_limit()now returns-EOPNOTSUPP, where it used to return-EPERMonce the PI voltage had been read.
Quoted 6 lines
- The PI regulators no longer show up in the regulator sysfs and debugfs, and over-current and over-temperature events are no longer sent on a regulator notifier chain. The ethtool notifications are unchanged.
Fixes ffef61d6d273 ("net: pse-pd: Add support for budget evaluation strategies")
Not sure we should write this as a fix as it is a big change of the framework and it is related to the initial support for the PoE.
Also as it is a big rework it is hard to read. Could you split this patch in a series?
You could first add the new helpers, then replace the call for regulator consumer functions in the ethtool functions, then remove the regulator provider. If needed, you can add "#if 0" around regulator specific call for the purpose of having more readable patch. Of course they should be removed at the end of your series.
After a quick look this seems good.
You can also remove the pse_send_ntf_worker() and send notification directly in the irq_handler.
Quoted 98 lines
Signed-off-by Kyle Swenson <[email protected]>---
RFC: I'm posting this RFC to discuss how the ABBA deadlock in the PSE core should be fixed. The deadlock was pointed out by Sashiko in [1], and I've hit it in testing [2]:Quoted 8 lines
This isn't a bug introduced by this patch, but choosing the static budget strategy exposes a lock ordering problem that already exists in the PSE core.
pse_isr()holdspcdev->lockand ends up taking the supply regulator lock [...] An admin enable running at the same time takes the locks in the opposite order [...] Theww_mutexscheme cannot break a cycle that includes the plainpcdev->lockmutex.With no PI regulator, nothing takes
pcdev->lockfrom inside a regulator callback, so only thepcdev->lock-> regulator lock order remains.This RFC is one approach of probably several possible ways to fix the deadlock. That said, after exploring this approach, I've found several other problems others have hit in their drivers on the list get fixed as a result:
Setting a power limit on an unpowered port fails
------------------------------------------------The core needs a port voltage to turn mW into uA for the regulator API [3]:
Quoted 2 lines
netlink error: Can't calculate the current, PSE voltage read is 0 netlink error: Result not representable
Kory's suggestion was that
pi_get_voltageshould not return 0 [4]:Quoted 2 lines
To have this working the
pi_get_voltageshould return some value even with no PD plugged.The Realtek PSE MCU driver already works around it this way [5]:
Quoted 3 lines
core: return constant voltage when MCU reports zero, in case the port is not delivering. This avoids "Voltage null" errors in case a power limit is set while port is not delivering (Sashiko)
The limit is now handed to
pi_set_pw_limit()in mW, so no voltage is needed andpi_get_voltagehas no remaining user in the core.Overflow and precision loss in the mW -> uA -> mW conversion
------------------------------------------------------------The conversion can overflow on drivers that report a measured voltage [6]:
Quoted 4 lines
For the largest allowed limit, 99900 mW, that overflows below about 46.5 mV. Only 0 V is rejected, and si3474 reports the measured voltage of each port. A negative result then hits the
BUG_ON()inregulator_check_current_limit().The conversion is removed, along with
pse_pi_get_current_limit(), so the possibility of losing precision on the way back to mW is gone too.Use-after-free in the PI regulator ops
--------------------------------------The PI regulator ops can run after the PI array is freed [7]:
Quoted 4 lines
When
regulator_unregister()flushes a pending disable, the regulator core invokespse_pi_disable(), which dereferences pcdev->pi[id] [...] At that point the PI array is already freed, so this is a use-after-free.The PI regulator and its ops are removed.
Regulator enable count out of step after a failed disable
---------------------------------------------------------
pse_pi_disable()always returns 0, so the regulator's enable count gets out of step with the PI state after a failed disable [8]:Quoted 3 lines
a further disable attempt calls
regulator_disable()withuse_count== 0, which the regulator core rejects with a WARN and-EIO.Each PI now tracks its own enable reference on the power domain supply. A failed hardware disable is still not reported, as before.
PI lookups returning -EPROBE_DEFER after registration
-----------------------------------------------------PI lookups can keep returning -EPROBE_DEFER after the controller has registered, because
pse_control_get()goes through the PI regulator [9]:Quoted 6 lines
A PI lookup in that window still returns -EPROBE_DEFER:
pse_control_get_internal()
regulator_get_exclusive()
_regulator_get_common()
regulator_resolve_supply()
Quoted 8 lines
pse_control_get()no longer gets a regulator. A PI whose supply has not registered yet is still left without a power domain, as before.Power domain matching
---------------------Power domains are now matched on the provider's DT node instead of
regulator_is_equal()on therdev->supply.
Yes thanks for listing all these issues, that was kind of all the ones I had in mind to express my wish to remove the support for the PIs regulator. I can add also that we can also remove the pse_send_ntf_worker() function and synchronize the ethtool notification with the PSE interrupts.
Quoted 33 lines
Drawbacks
---------Maybe some drawbacks of the approach (but I'm biased, so hopefully others can point out more severe problems):
* PI regulators are dropped from sysfs/debugfs
* There is now a hard dependency on OF. I'm not sure if this matters, since there's not a PSE driver with ACPI match tables in the tree. Perhaps if one is added, the supply lookup can be reworked at that point.The broader trade-off of dropping the PI regulator was discussed in [10], [11] and [12].
Finally, while this is fixing a deadlock I've hit pretty often in testing, and has a "Fixes" tag, to me it's adjusting an intentional design point of the PSE core, which implies it's a new change. I don't have a preference either way, and it doesn't matter for RFC.
[1] https://lore.kernel.org/netdev/[email protected]/
[2] https://lore.kernel.org/netdev/asM8rcKC1n1Tn4JD@est-xps15/
[3] https://lore.kernel.org/netdev/[email protected]/
[4] https://lore.kernel.org/netdev/[email protected]/
[5] https://lore.kernel.org/netdev/[email protected]/
[6] https://lore.kernel.org/netdev/[email protected]/
[7] https://lore.kernel.org/netdev/[email protected]/
[8] https://lore.kernel.org/netdev/[email protected]/
[9] https://lore.kernel.org/netdev/[email protected]/
[10] https://lore.kernel.org/netdev/[email protected]/
[11] https://lore.kernel.org/netdev/[email protected]/
[12] https://lore.kernel.org/netdev/[email protected]/
---
...
Quoted 7 lines
+/**
+ *pse_pi_supply_np- node the "vpwr" supply of a PI is looked up from
+ * @pcdev: a pointer to the PSE controller device
+ * @id: index of the PSE PI
+ *
+ * The PI regulator used to resolve its "vpwr" supply through
+ *regulator_resolve_supply(): first on the regulator device, whose node was
Quoted 8 lines
+ * the PI node, then on the parent device, the controller, whose own
+ * vpwr-supply is parsed beforeof_get_child_regulator()walks its children.
+ *of_regulator_get()walks the children of the consumer device, the
+ * controller, so the walk over the PI node's own children is not kept: a
+ * vpwr-supply in a child node of a PI is no longer found from that PI. The
+ * PI node is used only when it names a supply itself, because otherwise the
+ * child walk would answer from a sibling PI's supply before the controller
+ * node had its turn.
Not sure I understand it well but PI nodes do not have children. We should resolve the regulator for the PI node only, as described in the binding.
Signature · 3 lines
Köry Maincent, Bootlin Embedded Linux and kernel engineering https://bootlin.com
Quoted 9 lines · Kory Maincent
Thanks you for this work!
Quoted 5 lines · Kyle Swenson
Commit
ffef61d6d273("net: pse-pd: Add support for budget evaluation strategies") introduced an unusual regulator usecase- that is, a device that's both a consumer and provider of the same regulator: every PI is registered as a regulator whose "vpwr" supply is also requested by the PSE core for the power domain.
Quoted 12 lines
The unusual usecase was not introduced in that commit but in the initial support for PoE. With Oleksij, we initially thought that a PSE PI is something providing power therefore it look like a regulator provider behavior. In that case if we nest PSE PI and the regulator framework, the featured added for the PSE PIs could improve regulator framework and feature already supported by the regulator could be useful for the PSE PI case. Due to this idea, we had nested the frameworks and each PSE PI register a regulator provider. The thing is that there is no device that could represent the regulator consumer, the real device is the PD plugged on the Ethernet port but it is not represented by the software.
Finally we end up with this unusual usecase to have each PSE PIs to be a regulator provider and its own consumer.
Ack, thanks for the background. I'll rephrase and drop the commit
reference.
Quoted 71 lines
However along the development no advantage of using such usecase appeared except for the power budget, but it is different because it is related to the PSE PI supply parent not the PI itself. This is the "vpwr" supply described in the binding.
This usecase was for now, only adding code complexity, function wrapper, and several deadlock issues as you have described below.Quoted 63 lines
This ended up causing a significant amount of complication for the PSE core, and can result in an ABBA deadlock that lockdep doesn't see. The deadlock can happen when PSE ops are running concurrent with the
pse_isr, and I noticed it when a PoE port is enabled via ethtool and that PoE port has a device that is ready to be powered.- As a regulator provider, PSE's ops (
is_enabled, enable, disable, ...)take pcdev->lock while the core already holds the regulator lock (regulator lock -> pcdev->lock).- As a consumer of the power-budget API,
pse_isr(),pse_ethtool_set_pw_limit()andpse_ethtool_set_prio()call regulator_request/free_power_budget() (which take the supply's regulator lock) while holdingpcdev->lock, from contexts that are not regulator callbacks (pcdev->lock-> regulator lock).And this can deadlock because the locking order between
pcdev->lockand the regulator lock is inverted in the two paths.Lockdep doesn't flag this deadlock because
regulator_lock_nested()takes the lock viaww_mutex_trylock(), and apparently lockdep doesn't record a dependency for a trylock. However, if the trylock is adjusted to always block, lockdep does report the ordering violation.One way to fix this complication is to not register a regulator provider per PI and reduce the pse_core's usage to only be a regulator consumer. The regulator core used to provide some behaviour as a side effect of the PI regulator, which the PSE core now does itself:
- Enabling a PI enabled its "vpwr" supply, and a PI found enabled when its control was acquired took a reference on it. Each PI now tracks whether it holds an enable reference on the power domain supply.
- The "vpwr" supply was resolved from the PI node, then from the controller node. It is now requested with
of_regulator_get()from the same nodes, and power domains are matched on the provider node rather than withregulator_is_equal(). Consequently,PSE_CONTROLLERnow depends on OF.- A supply whose provider has not registered yet still leaves the PI without a power domain, as before.
pse_control_get()used to return -EPROBE_DEFER until that supply resolved, since getting the PI regulator resolved its supply; it now succeeds right away.- A failing hardware disable is still not reported, and the supply reference is still released, as the regulator disable callback did.
- A failing
regulator_disable()of the supply is not retried, as with the regulator devres helpers: the regulator core may already have dropped the consumer's enable reference when it reports the error.User visible changes:
-
pse_ethtool_set_pw_limit()hands the limit in mW straight topi_set_pw_limit(). A controller withoutpi_set_pw_limit()now returns-EOPNOTSUPP, where it used to return-EPERMonce the PI voltage had been read.- The PI regulators no longer show up in the regulator sysfs and debugfs, and over-current and over-temperature events are no longer sent on a regulator notifier chain. The ethtool notifications are unchanged.
Quoted 4 lines
Quoted 1 line
Fixes ffef61d6d273 ("net: pse-pd: Add support for budget evaluation strategies")Not sure we should write this as a fix as it is a big change of the framework and it is related to the initial support for the PoE.
Yeah, I was unsure about if this should be a fix or not myself. I think not a fix is more appropriate, so I'll drop the fixes tag and reword things to reflect that.
Quoted 3 lines
Also as it is a big rework it is hard to read. Could you split this patch in a series?
Yes, definitely. I'll subtmit v2 as a series and broken up into smaller commits.
Quoted 3 lines
You could first add the new helpers, then replace the call for regulator consumer functions in the ethtool functions, then remove the regulator provider.
Ack. This is a good way to break it up.
Quoted 3 lines
If needed, you can add "#if 0" around regulator specific call for the purpose of having more readable patch. Of course they should be removed at the end of your series.
Of course. I'll plan on keeping it RFC unless you prefer otherwise.
Quoted 4 lines
After a quick look this seems good.
You can also remove thepse_send_ntf_worker()and send notification directly in theirq_handler.
Sounds good, I'll address in the v2.
Quoted 105 lines
Quoted 105 lines
Signed-off-by Kyle Swenson <[email protected]>---
RFC: I'm posting this RFC to discuss how the ABBA deadlock in the PSE core should be fixed. The deadlock was pointed out by Sashiko in [1], and I've hit it in testing [2]:Quoted 8 lines
This isn't a bug introduced by this patch, but choosing the static budget strategy exposes a lock ordering problem that already exists in the PSE core.
pse_isr()holdspcdev->lockand ends up taking the supply regulator lock [...] An admin enable running at the same time takes the locks in the opposite order [...] Theww_mutexscheme cannot break a cycle that includes the plainpcdev->lockmutex.With no PI regulator, nothing takes
pcdev->lockfrom inside a regulator callback, so only thepcdev->lock-> regulator lock order remains.This RFC is one approach of probably several possible ways to fix the deadlock. That said, after exploring this approach, I've found several other problems others have hit in their drivers on the list get fixed as a result:
Setting a power limit on an unpowered port fails
------------------------------------------------The core needs a port voltage to turn mW into uA for the regulator API [3]:
Quoted 2 lines
netlink error: Can't calculate the current, PSE voltage read is 0 netlink error: Result not representable
Kory's suggestion was that
pi_get_voltageshould not return 0 [4]:Quoted 2 lines
To have this working the
pi_get_voltageshould return some value even with no PD plugged.The Realtek PSE MCU driver already works around it this way [5]:
Quoted 3 lines
core: return constant voltage when MCU reports zero, in case the port is not delivering. This avoids "Voltage null" errors in case a power limit is set while port is not delivering (Sashiko)
The limit is now handed to
pi_set_pw_limit()in mW, so no voltage is needed andpi_get_voltagehas no remaining user in the core.Overflow and precision loss in the mW -> uA -> mW conversion
------------------------------------------------------------The conversion can overflow on drivers that report a measured voltage [6]:
Quoted 4 lines
For the largest allowed limit, 99900 mW, that overflows below about 46.5 mV. Only 0 V is rejected, and si3474 reports the measured voltage of each port. A negative result then hits the
BUG_ON()inregulator_check_current_limit().The conversion is removed, along with
pse_pi_get_current_limit(), so the possibility of losing precision on the way back to mW is gone too.Use-after-free in the PI regulator ops
--------------------------------------The PI regulator ops can run after the PI array is freed [7]:
Quoted 4 lines
When
regulator_unregister()flushes a pending disable, the regulator core invokespse_pi_disable(), which dereferences pcdev->pi[id] [...] At that point the PI array is already freed, so this is a use-after-free.The PI regulator and its ops are removed.
Regulator enable count out of step after a failed disable
---------------------------------------------------------
pse_pi_disable()always returns 0, so the regulator's enable count gets out of step with the PI state after a failed disable [8]:Quoted 3 lines
a further disable attempt calls
regulator_disable()withuse_count== 0, which the regulator core rejects with a WARN and-EIO.Each PI now tracks its own enable reference on the power domain supply. A failed hardware disable is still not reported, as before.
PI lookups returning -EPROBE_DEFER after registration
-----------------------------------------------------PI lookups can keep returning -EPROBE_DEFER after the controller has registered, because
pse_control_get()goes through the PI regulator [9]:Quoted 6 lines
A PI lookup in that window still returns -EPROBE_DEFER:
pse_control_get_internal()
regulator_get_exclusive()
_regulator_get_common()
regulator_resolve_supply()
pse_control_get()no longer gets a regulator. A PI whose supply has not registered yet is still left without a power domain, as before.Power domain matching
---------------------
Quoted 8 lines
Quoted 2 lines
Power domains are now matched on the provider's DT node instead of
regulator_is_equal()on therdev->supply.Yes thanks for listing all these issues, that was kind of all the ones I had in mind to express my wish to remove the support for the PIs regulator. I can add also that we can also remove the
pse_send_ntf_worker()function and synchronize the ethtool notification with the PSE interrupts.
Sure, no problem. Removing the pse_send_ntf_worker() simplifies things further.
Quoted 52 lines
Quoted 33 lines
Drawbacks
---------Maybe some drawbacks of the approach (but I'm biased, so hopefully others can point out more severe problems):
* PI regulators are dropped from sysfs/debugfs
* There is now a hard dependency on OF. I'm not sure if this matters, since there's not a PSE driver with ACPI match tables in the tree. Perhaps if one is added, the supply lookup can be reworked at that point.The broader trade-off of dropping the PI regulator was discussed in [10], [11] and [12].
Finally, while this is fixing a deadlock I've hit pretty often in testing, and has a "Fixes" tag, to me it's adjusting an intentional design point of the PSE core, which implies it's a new change. I don't have a preference either way, and it doesn't matter for RFC.
[1] https://lore.kernel.org/netdev/[email protected]/
[2] https://lore.kernel.org/netdev/asM8rcKC1n1Tn4JD@est-xps15/
[3] https://lore.kernel.org/netdev/[email protected]/
[4] https://lore.kernel.org/netdev/[email protected]/
[5] https://lore.kernel.org/netdev/[email protected]/
[6] https://lore.kernel.org/netdev/[email protected]/
[7] https://lore.kernel.org/netdev/[email protected]/
[8] https://lore.kernel.org/netdev/[email protected]/
[9] https://lore.kernel.org/netdev/[email protected]/
[10] https://lore.kernel.org/netdev/[email protected]/
[11] https://lore.kernel.org/netdev/[email protected]/
[12] https://lore.kernel.org/netdev/[email protected]/
---...
Quoted 7 lines
+/**
+ *pse_pi_supply_np- node the "vpwr" supply of a PI is looked up from
+ * @pcdev: a pointer to the PSE controller device
+ * @id: index of the PSE PI
+ *
+ * The PI regulator used to resolve its "vpwr" supply through
+ *regulator_resolve_supply(): first on the regulator device, whose node wasQuoted 8 lines
+ * the PI node, then on the parent device, the controller, whose own
+ * vpwr-supply is parsed beforeof_get_child_regulator()walks its children.
+ *of_regulator_get()walks the children of the consumer device, the
+ * controller, so the walk over the PI node's own children is not kept: a
+ * vpwr-supply in a child node of a PI is no longer found from that PI. The
+ * PI node is used only when it names a supply itself, because otherwise the
+ * child walk would answer from a sibling PI's supply before the controller
+ * node had its turn.
Quoted 2 lines
Not sure I understand it well but PI nodes do not have children. We should resolve the regulator for the PI node only, as described in the binding.
Ack, I think I way over-complicated the regulator resolution. I'll simplify in v2.
Thanks so much for the feedback!
Cheers,
Kyle