Input: goodix - sync the irq controller while starting firmware
Subsystems (4)
PATCH 1/1 Input: goodix - sync the irq controller while starting firmware
On the Lenovo Tab E7 TB-7104F which has a Goodix GT-912F touch screen, the touch screen fails to come online after loading firmware, producing the error "Error reading 1 bytes from 0x8041: -6".
Comparing the upstream code with the Android stock sources a call to goodix_int_sync is required between the upload of the firmware and the watchdog restart. With this change the touchscreen is correctly detected and working.
---
Relevant bit of the stock source driver at [1].
Credits for noticing the issue and finding its cause go to matemiller992 on the postmarketOS forums, I cannot provide tags as he wants to stay anonymous.
drivers/input/touchscreen/goodix_fwupload.c | 5 +++++ 1 file changed, 5 insertions(+)
drivers/input/touchscreen/goodix_fwupload.c +5 -0
@@ -155,6 +155,7 @@ static int goodix_enter_upload_mode(struct i2c_client *client)static int goodix_start_firmware (struct i2c_client *client) { +struct goodix_ts_data *ts =i2c_get_clientdata (client);int error;u8 val;
@@ -168,6 +169,10 @@ static int goodix_start_firmware(struct i2c_client *client)if (error)return error; + error =goodix_int_sync (ts); +if (error) +return error; + error =goodix_i2c_read (client,GOODIX_REG_SW_WDT , &val,1 );if (error)return error;
Signature · 1 line
2.43.0
Dmitry Torokhov
maintainerHi Luca,
Quoted 35 lines · Luca Leonardo Scorcia
On the Lenovo Tab E7 TB-7104F which has a Goodix GT-912F touch screen, the touch screen fails to come online after loading firmware, producing the error "Error reading 1 bytes from
0x8041: -6".Comparing the upstream code with the Android stock sources a call to
goodix_int_syncis required between the upload of the firmware and the watchdog restart. With this change the touchscreen is correctly detected and working.Signed-off-by Luca Leonardo Scorcia <[email protected]>---
Relevant bit of the stock source driver at [1].Credits for noticing the issue and finding its cause go to matemiller992 on the postmarketOS forums, I cannot provide tags as he wants to stay anonymous.
drivers/input/touchscreen/goodix_fwupload.c | 5 +++++ 1 file changed, 5 insertions(+)drivers/input/touchscreen/goodix_fwupload.c +1
-0@@ -155,6 +155,7 @@ static int goodix_enter_upload_mode(struct i2c_client *client)static int goodix_start_firmware (struct i2c_client *client) { +struct goodix_ts_data *ts =i2c_get_clientdata (client);int error;u8 val;
drivers/input/touchscreen/goodix_fwupload.c static int goodix_start_firmware(struct i2c_client *client) · line 175
Quoted 7 lines
drivers/input/touchscreen/goodix_fwupload.c +4
-0@@ -168,6 +169,10 @@ static int goodix_start_firmware(struct i2c_client *client)if (error)return error; + error =goodix_int_sync (ts); +if (error) +return error; +
There is call to goodix_int_sync() right after call to goodix_start_firmware(). Is it still needed if we call it here? I think the vendor drivers does not do it.
drivers/input/touchscreen/goodix_fwupload.c static int goodix_start_firmware(struct i2c_client *client) · line 178
Quoted 3 lines
drivers/input/touchscreen/goodix_fwupload.c +0
-0error =goodix_i2c_read (client,GOODIX_REG_SW_WDT , &val,1 );if (error)return error;
Thanks.
Signature · 1 line
Dmitry
Quoted 3 lines
There is call to
goodix_int_sync()right after call togoodix_start_firmware(). Is it still needed if we call it here? I think the vendor drivers does not do it.
Hi,
unfortunately yes, it's needed right there on the Lenovo Tab E7. Without it, the REG_SW_WDT right after it fails with the error "Error reading 1 bytes from 0x8041: -6".
The vendor sources for this device [1] show the call to goodix_int_sync exactly between the two interactions with the WDT register.
Actually, in the same sources I see no trace of a second goodix_int_sync after firmware has loaded, so the existing call could be moved a little earlier instead of introducing a duplicated new one. I tested moving the existing call on my device and it works just as fine (basically, my patch + commenting out the existing call at the end of goodix_firmware_upload.
Which vendor sources are you using for your reference?
Thank you,
Luca