Skip to contentSkip to conversation

64k streams not supported

DISCUSSION David Laight 3 participants 4 messages Aug 21, 2020 SCTP protocol

lore
Share & tools
lore
#0 lore raw

Isn't SCTP supposed to support 65536 data streams?
If I try to enable that many I get 10.
Not surprising since the number of streams gets stored in a u16.

The whole code base may need changing to save the highest valid stream?

Since I don't actually need that many I'm not writing the patch.

David

-
Registered Address Lakeside, Bramley Road, Mount Farm, Milton Keynes, MK1 1PT, UK Registration No: 1397386 (Wales)

#1 lore raw
Quoted 1 line · David Laight

Isn't SCTP supposed to support 65536 data streams?

Hm, no? Why?

https://tools.ietf.org/html/rfc4960#section-5.1.1
"After the association is initialized, the valid outbound stream identifier range for either endpoint shall be 0 to min(local OS, remote MIS)-1."

Section 3.3.2:
Number of Outbound Streams (OS): 16 bits (unsigned integer)

Defines the number of outbound streams the sender of this INIT chunk wishes to create in this association. The value of 0 MUST NOT be used.

...

Number of Inbound Streams (MIS): 16 bits (unsigned integer)

Defines the maximum number of streams the sender of this INIT chunk allows the peer end to create in this association. The value 0 MUST NOT be used.

Marcelo

#2 lore raw
In reply to David Laight
Quoted 3 lines · David Laight

Isn't SCTP supposed to support 65536 data streams?

Since the number of streams is exchanged in the INIT and INIT-ACK chunks and encoded in a uint16_t, the number is 65535, not 65536. So an implementation should be able to use up to 65535 incoming and outgoing streams.

Best regards
Michael

Quoted 14 lines

If I try to enable that many I get 10.
Not surprising since the number of streams gets stored in a u16.

The whole code base may need changing to save the highest valid stream?

Since I don't actually need that many I'm not writing the patch.

David

-
Registered Address Lakeside, Bramley Road, Mount Farm, Milton Keynes, MK1 1PT, UK Registration No: 1397386 (Wales)

#3 lore raw
In reply to David Laight

From: Michael Tuexen

Quoted 9 lines

Sent: 21 August 2020 21:10

Quoted 3 lines · David Laight

Isn't SCTP supposed to support 65536 data streams?

Since the number of streams is exchanged in the INIT and INIT-ACK chunks and encoded in a uint16_t, the number is 65535, not 65536. So an implementation should be able to use up to 65535 incoming and outgoing streams.

Ah, I'd assumed that because the stream number was encoded in 16 bits you could use stream numbers 0 through 65535.

At least no one needs to write the patch :-)

David

-
Registered Address Lakeside, Bramley Road, Mount Farm, Milton Keynes, MK1 1PT, UK Registration No: 1397386 (Wales)