Skip to contentSkip to conversation

telemetry conns may leak in certain situation

Bug 1364 [email protected] 1 participant 1 message Jan 13, 2024

lore
Share & tools
lore
#0 lore raw

https://bugs.dpdk.org/show_bug.cgi?id=1364

            Bug ID: 1364
           Summary: telemetry conns may leak in certain situation
           Product: DPDK
           Version: unspecified
          Hardware: All
                OS: All
            Status: UNCONFIRMED
          Severity: normal
          Priority: Normal
         Component: other
          Assignee: [email protected]
          Reporter: [email protected]

Target Milestone: ---

Every time the telemetry server successfully returns from the accept, it atomically increases the value of num_clients(if < MAX_CONNECTIONS) and then executes pthread_create to create a thread to execute the client_handler function. In this function, some information will be written to the client. If the write fails, the thread returns NULL without atomically reducing num_clients, this will cause the Telemetry server to run for a period of time, and the value of num_clients will be greater than 10, resulting in telemetry being unavailable.
Therefore, the decrease in atomicity v2_clients should occur after the write() failure