drivers: fix incorrect E-Switch manager vport ID
PATCH 1/1 drivers: fix incorrect E-Switch manager vport ID
One of the E-Switch vports plays the special role - it is assigned as "E-Switch manager" and has some special exclusive rights and duties - it maintains all the representors, manages FDB domain flows, etc. By default, the E-Switch vport index was supposed to be zero on standalone NICs (regular ConnectX) and 0xFFFE SmartNIC (BlueField), but that was not always correct - this index can be assigned with any value by kernel/hypervisor.
Currently the E-Switch manager vport id is supposed to be default - 0 for standalone NICs, and 0xFFFE for the SmartNICs, and is deduced from the device PCI id.
To handle this and do not suggest any default values, can use DevX API to query E-Switch manager vport ID directly from the firmware during initialization, and use that value by default. If the new method is not provided (legacy firmware), fallback to use the PCI id approach.
--- drivers/common/mlx5/mlx5_devx_cmds.c | 12 ++++++++++++ drivers/common/mlx5/mlx5_devx_cmds.h | 2 ++ drivers/common/mlx5/mlx5_prm.h | 12 ++++++++++++ drivers/net/mlx5/mlx5_flow_dv.c | 4 ++++ 4 files changed, 30 insertions(+)
drivers/common/mlx5/mlx5_devx_cmds.c +12 -0
@@ -1130,6 +1130,18 @@ mlx5_devx_cmd_query_hca_attr(void *ctx, goto error; } } +if (attr->eswitch_manager) { + hcattr =mlx5_devx_get_hca_cap (ctx, in, out, &rc, +MLX5_SET_HCA_CAP_OP_MOD_ESW | +MLX5_HCA_CAP_OPMOD_GET_CUR ); +if (!hcattr) +return rc; + attr->esw_mgr_vport_id_valid = +MLX5_GET (esw_cap, hcattr, + esw_manager_vport_number_valid); + attr->esw_mgr_vport_id = +MLX5_GET (esw_cap, hcattr, esw_manager_vport_number); + }return 0 ; error: rc = (rc >0 ) ? -rc : rc;
drivers/common/mlx5/mlx5_devx_cmds.h +2 -0
@@ -252,6 +252,8 @@ struct mlx5_hca_attr { uint32_t umr_modify_entity_size_disabled:1; uint32_t umr_indirect_mkey_disabled:1; uint32_t log_min_stride_wqe_sz:5; + uint32_t esw_mgr_vport_id_valid:1; /* E-Switch Mgr vport ID is valid. */ +uint16_t esw_mgr_vport_id;/* E-Switch Mgr vport ID . */ uint16_t max_wqe_sz_sq; };
drivers/common/mlx5/mlx5_prm.h +12 -0
@@ -1264,6 +1264,7 @@ enum {MLX5_GET_HCA_CAP_OP_MOD_QOS_CAP =0xc <<1 ,MLX5_GET_HCA_CAP_OP_MOD_ROCE =0x4 <<1 ,MLX5_GET_HCA_CAP_OP_MOD_NIC_FLOW_TABLE =0x7 <<1 , +MLX5_SET_HCA_CAP_OP_MOD_ESW =0x9 <<1 ,MLX5_GET_HCA_CAP_OP_MOD_VDPA_EMULATION =0x13 <<1 ,MLX5_GET_HCA_CAP_OP_MOD_PARSE_GRAPH_NODE_CAP =0x1C <<1 , MLX5_GET_HCA_CAP_OP_MOD_GENERAL_DEVICE_2 = 0x20 << 1,
@@ -1926,6 +1927,16 @@ struct mlx5_ifc_cmd_hca_cap_2_bits {u8 reserved_at_100[0x700 ]; }; +struct mlx5_ifc_esw_cap_bits { +u8 reserved_at_0[0x60 ]; + +u8 esw_manager_vport_number_valid[0x1 ]; +u8 reserved_at_61[0xf ]; +u8 esw_manager_vport_number[0x10 ]; + +u8 reserved_at_80[0x780 ]; +}; +union mlx5_ifc_hca_cap_union_bits {struct mlx5_ifc_cmd_hca_cap_bits cmd_hca_cap;struct mlx5_ifc_cmd_hca_cap_2_bits cmd_hca_cap_2;
@@ -1934,6 +1945,7 @@ union mlx5_ifc_hca_cap_union_bits {struct mlx5_ifc_qos_cap_bits qos_cap;struct mlx5_ifc_virtio_emulation_cap_bits vdpa_caps;struct mlx5_ifc_flow_table_nic_cap_bits flow_table_nic_cap; +struct mlx5_ifc_esw_cap_bits esw_cap;struct mlx5_ifc_roce_caps_bits roce_caps;u8 reserved_at_0[0x8000 ]; };
drivers/net/mlx5/mlx5_flow_dv.c +4 -0
@@ -97,6 +97,10 @@ static int16_t flow_dv_get_esw_manager_vport_id(struct rte_eth_dev *dev) {struct mlx5_priv *priv = dev->data->dev_private; +struct mlx5_common_device *cdev = priv->sh->cdev; + +if (cdev->config.hca_attr.esw_mgr_vport_id_valid) +return (int16_t )cdev->config.hca_attr.esw_mgr_vport_id;if (priv->pci_dev ==NULL )return 0 ;
Signature · 1 line
2.20.0
Hi,
Quoted 26 lines
-----Original Message-----
From: Shun Hao <[email protected]>
Sent: Tuesday, February 22, 2022 5:07 PM
To: Matan Azrad <[email protected]>; Slava Ovsiienko <[email protected]>; [email protected] ; [email protected] ; Xueming(Steven) Li <[email protected]>
Cc: [email protected] ; Raslan Darawsheh <[email protected]>; [email protected]
Subject: [PATCH v1] drivers: fix incorrect E-Switch manager vport IDOne of the E-Switch vports plays the special role - it is assigned as "E-Switch manager" and has some special exclusive rights and duties - it maintains all the representors, manages FDB domain flows, etc. By default, the E-Switch vport index was supposed to be zero on standalone NICs (regular ConnectX) and
0xFFFESmartNIC (BlueField), but that was not always correct - this index can be assigned with any value by kernel/hypervisor.Currently the E-Switch manager vport id is supposed to be default - 0 for standalone NICs, and
0xFFFEfor the SmartNICs, and is deduced from the device PCI id.To handle this and do not suggest any default values, can use DevX API to query E-Switch manager vport ID directly from the firmware during initialization, and use that value by default. If the new method is not provided (legacy firmware), fallback to use the PCI id approach.
Quoted 6 lines
Fixes a564038699f9 ("net/mlx5: support E-Switch manager egress trafficmatch")
Cc: [email protected]Signed-off-by Shun Hao <[email protected]>
Patch applied to next-net-mlx,
Kindest regards,
Raslan Darawsheh
Quoted 28 lines · Raslan Darawsheh
Hi,
Quoted 26 lines
-----Original Message-----
From: Shun Hao <[email protected]>
Sent: Tuesday, February 22, 2022 5:07 PM
To: Matan Azrad <[email protected]>; Slava Ovsiienko <[email protected]>; [email protected] ; [email protected] ; Xueming(Steven) Li <[email protected]>
Cc: [email protected] ; Raslan Darawsheh <[email protected]>; [email protected]
Subject: [PATCH v1] drivers: fix incorrect E-Switch manager vport IDOne of the E-Switch vports plays the special role - it is assigned as "E-Switch manager" and has some special exclusive rights and duties - it maintains all the representors, manages FDB domain flows, etc. By default, the E-Switch vport index was supposed to be zero on standalone NICs (regular ConnectX) and
0xFFFESmartNIC (BlueField), but that was not always correct - this index can be assigned with any value by kernel/hypervisor.Currently the E-Switch manager vport id is supposed to be default - 0 for standalone NICs, and
0xFFFEfor the SmartNICs, and is deduced from the device PCI id.To handle this and do not suggest any default values, can use DevX API to query E-Switch manager vport ID directly from the firmware during initialization, and use that value by default. If the new method is not provided (legacy firmware), fallback to use the PCI id approach.
Quoted 9 lines
Quoted 6 lines
Fixes a564038699f9 ("net/mlx5: support E-Switch manager egress trafficmatch")
Cc: [email protected]Signed-off-by Shun Hao <[email protected]>Patch applied to next-net-mlx,
Hi Raslan,
Can you make a patch to add 'E-Switch' keyword to './devtools/words-case.txt', in the syntax how it suppose to be? (There are various variants of it in the commit history.)
Hi,
Quoted 50 lines
-----Original Message-----
From: Ferruh Yigit <[email protected]>
Sent: Wednesday, February 23, 2022 9:00 PM
To: Raslan Darawsheh <[email protected]>; Shun Hao <[email protected]>; Matan Azrad <[email protected]>; Slava Ovsiienko <[email protected]>; Ori Kam <[email protected]>; NBU-Contact- Thomas Monjalon (EXTERNAL) <[email protected]>; Xueming(Steven) Li <[email protected]>
Cc: dpdk-dev <[email protected]>; [email protected]
Subject: Re: [PATCH v1] drivers: fix incorrect E-Switch manager vport IDQuoted 18 lines · Raslan Darawsheh
Hi,
Quoted 16 lines
-----Original Message-----
From: Shun Hao <[email protected]>
Sent: Tuesday, February 22, 2022 5:07 PM
To: Matan Azrad <[email protected]>; Slava Ovsiienko <[email protected]>; [email protected] ; [email protected] ; Xueming(Steven) Li <[email protected]>
Cc: [email protected] ; Raslan Darawsheh <[email protected]>; [email protected]
Subject: [PATCH v1] drivers: fix incorrect E-Switch manager vport IDOne of the E-Switch vports plays the special role - it is assigned as "E-Switch manager" and has some special exclusive rights and duties - it maintains all the representors, manages FDB domain flows, etc. By default, the E-Switch vport index was supposed to be zero on standalone NICs (regular ConnectX) and
0xFFFESmartNIC (BlueField), but that was not always correct - this index can be assigned with any valueby kernel/hypervisor.
Quoted 9 lines
Quoted 9 lines
Currently the E-Switch manager vport id is supposed to be default - 0 for standalone NICs, and
0xFFFEfor the SmartNICs, and is deduced from the device PCI id.To handle this and do not suggest any default values, can use DevX API to query E-Switch manager vport ID directly from the firmware during initialization, and use that value by default. If the new method is not provided (legacy firmware), fallback to use the PCI id
approach.
Quoted 9 lines
Quoted 8 lines
Fixes a564038699f9 ("net/mlx5: support E-Switch manager egresstraffic
match")
Cc: [email protected]Signed-off-by Shun Hao <[email protected]>
Quoted 8 lines
Quoted 2 lines
Patch applied to next-net-mlx,
Hi Raslan,
Can you make a patch to add 'E-Switch' keyword to './devtools/words- case.txt', in the syntax how it suppose to be? (There are various variants of it in the commit history.)
Sure, will send a patch for it, and I think the correct syntax should be E-Switch as written in this patch.
Kindest regards,
Raslan Darawsheh