virtiofs submounts that are still in use forgotten by shrinker
Subsystems (2)
v2 cover virtiofs submounts that are still in use forgotten by shrinker
Hi,
I recently ran into a situation where a virtiofs client began encountering EBADF after the client / guest system had an OOM. After reproducing the issue and debugging, the problem is caused by a virtiofsd submount having the nodeid of its root dentry fogotten. This occurs because it borrows the reference for this dentry from the parent that is passed into the function.
In this particular case, the submount had been bind mounted into a container's mount namespace. The reference count on the original parent dentry was 0, making it eligible for eviction. However, because this dentry was also the last reference the fuse client knew it had, it sent a forget message to the server. This caused all future references to the FUSE node-id from virtiofsd perspective to become invalid. Subsequent attempts to use the node-id for operations against the submount's root received an EBADF from the server.
This pair of patches modifies the virtiofs submount code to perform a lookup on the nodeid that forms the root of the submount. The patch before this pulls the revalidate lookup code into a helper function that can be used both in revalidate and submount superblock fill.
Tested via:
- fstests for virtiofs
- fstests for fuse (against passthrough_ll)
- manual testing to watch how refcounts change between client and server in response to filesytem access, umount, and eviction by the shrinker.
This resend has rebased against the latest tip of fuse/for-next and massaged the commit messages in the patches, but hasn't made any functional modifications since the original v2.
There's also been an issue opened with the project that uses this functionality. More details on that can be found at [1].
Changes since v1:
- Cleanups to pacify test robot
Changes since RFC:
- Modified fuse_fill_super_submount to always fail if dentry cannot be revalidated. (Feedback from Bernd Schubert)
- Fixed up an edge case where looked up but subsequently declared invalid dentries were not correctly tracking nlookup. (Error was introduced in my RFC).
Thanks,
-K
[1] https://github.com/kata-containers/kata-containers/issues/8040
Krister Johansen (2):
fuse: revalidate: move lookup into a separate function
fuse: ensure that submounts lookup their parent
fs/fuse/dir.c | 85 +++++++++++++++++++++++++++++++++--------------- fs/fuse/fuse_i.h | 6 ++++ fs/fuse/inode.c | 43 ++++++++++++++++++++---- 3 files changed, 101 insertions(+), 33 deletions(-)
Signature · 1 line
2.25.1
PATCH RESEND v2 1/2 fuse: revalidate: move lookup into a separate function
Move the lookup parts of fuse_dentry_revalidate into a common function. This function will be used elsewhere in a separate commit. In the meantime, the new function fuse_dentry_revalidate_lookup is responsible for just the lookup and validation portions of the revalidate dance. The fuse_dentry_revalidate function retains the responsibility for invalidating and mutating any state associated with the origial fuse_inode and dentry.
The rationale for this refactoring is to allow a lookup to be triggered as part of creating a submount. The submount code lives in another module. A subsequent commit will utilize the common function that is created by this commit.
--- fs/fuse/dir.c | 85 +++++++++++++++++++++++++++++++++++---------------- 1 file changed, 58 insertions(+), 27 deletions(-)
fs/fuse/dir.c +58 -27
@@ -183,6 +183,57 @@ static void fuse_lookup_init(struct fuse_conn *fc, struct fuse_args *args, args->out_args[0 ].value = outarg; } +static int fuse_dentry_revalidate_lookup (struct fuse_mount *fm, +struct dentry *entry, +struct inode *inode, +struct fuse_entry_out *outarg, +bool *lookedup) +{ +struct dentry *parent; +struct fuse_forget_link *forget; +FUSE_ARGS (args); +int ret; + + forget =fuse_alloc_forget (); + ret = -ENOMEM ; +if (!forget) + goto out; + + parent =dget_parent (entry); +fuse_lookup_init (fm->fc, &args,get_node_id (d_inode (parent)), + &entry->d_name, outarg); + ret =fuse_simple_request (fm, &args); +dput (parent); + +/* Zero nodeid is same as -ENOENT */ +if (!ret && !outarg->nodeid) + ret = -ENOENT ; +if (!ret) { +if (outarg->nodeid !=get_node_id (inode) || + (bool )IS_AUTOMOUNT (inode) != (bool ) (outarg->attr.flags &FUSE_ATTR_SUBMOUNT )) { +fuse_queue_forget (fm->fc, forget, + outarg->nodeid,1 ); + goto invalid; + } + *lookedup = true; + } +kfree (forget); +if (ret == -ENOMEM || ret == -EINTR ) + goto out; +if (ret ||fuse_invalid_attr (&outarg->attr) || +fuse_stale_inode (inode, outarg->generation, &outarg->attr)) { + goto invalid; + } + + ret =1 ; +out: +return ret; + +invalid: + ret =0 ; + goto out; +} +/* * Check whether the dentry is still valid *
@@ -206,9 +257,8 @@ static int fuse_dentry_revalidate(struct dentry *entry, unsigned int flags)else if (time_before64 (fuse_dentry_time (entry),get_jiffies_64 ()) || (flags & (LOOKUP_EXCL |LOOKUP_REVAL |LOOKUP_RENAME_TARGET ))) {struct fuse_entry_out outarg; -FUSE_ARGS (args); -struct fuse_forget_link *forget;u64 attr_version; +bool lookedup = false;/* For negative dentries, always do a fresh lookup */ if (!inode)
@@ -220,38 +270,19 @@ static int fuse_dentry_revalidate(struct dentry *entry, unsigned int flags) fm =get_fuse_mount (inode); - forget =fuse_alloc_forget (); - ret = -ENOMEM ; -if (!forget) - goto out; - attr_version =fuse_get_attr_version (fm->fc); - parent =dget_parent (entry); -fuse_lookup_init (fm->fc, &args,get_node_id (d_inode (parent)), - &entry->d_name, &outarg); - ret =fuse_simple_request (fm, &args); -dput (parent); -/* Zero nodeid is same as -ENOENT */ -if (!ret && !outarg.nodeid) - ret = -ENOENT ; -if (!ret) { + ret =fuse_dentry_revalidate_lookup (fm, entry, inode, &outarg, + &lookedup); +if (ret == -ENOMEM || ret == -EINTR ) + goto out; +if (lookedup) { fi =get_fuse_inode (inode); -if (outarg.nodeid !=get_node_id (inode) || - (bool )IS_AUTOMOUNT (inode) != (bool ) (outarg.attr.flags &FUSE_ATTR_SUBMOUNT )) { -fuse_queue_forget (fm->fc, forget, - outarg.nodeid,1 ); - goto invalid; - }spin_lock (&fi->lock); fi->nlookup++;spin_unlock (&fi->lock); } -kfree (forget); -if (ret == -ENOMEM || ret == -EINTR ) - goto out; -if (ret ||fuse_invalid_attr (&outarg.attr) || -fuse_stale_inode (inode, outarg.generation, &outarg.attr)) +if (ret <=0 ) goto invalid;forget_all_cached_acls (inode);
Signature · 1 line
2.25.1
PATCH RESEND v2 2/2 fuse: ensure that submounts lookup their parent
In reply to Krister JohansenThe submount code uses the parent nodeid passed into the function in order to create the root dentry for the new submount. This nodeid does not get its remote reference count incremented by a lookup option.
If the parent inode is evicted from its superblock, due to memory pressure for example, it can result in a forget opertation being sent to the server. Should this nodeid be forgotten while it is still in use in a submount, users of the submount get an error from the server on any subsequent access. In the author's case, this was an EBADF on all subsequent operations that needed to reference the root.
Debugging the problem revealed that the dentry shrinker triggered a forget after killing the dentry with the last reference, despite the root dentry in another superblock still using the nodeid.
As a result, a container that was also using this submount failed to access its filesystem because it had borrowed the reference instead of taking its own when setting up its superblock for the submount.
This commit fixes the problem by having the new submount trigger a lookup for the parent as part of creating a new root dentry for the virtiofsd submount superblock. This allows each superblock to have its inodes removed by the shrinker when unreferenced, while keeping the nodeid reference count accurate and active with the server.
--- fs/fuse/dir.c | 10 +++++----- fs/fuse/fuse_i.h | 6 ++++++ fs/fuse/inode.c | 43 +++++++++++++++++++++++++++++++++++++------ 3 files changed, 48 insertions(+), 11 deletions(-)
fs/fuse/dir.c +5 -5
@@ -183,11 +183,11 @@ static void fuse_lookup_init(struct fuse_conn *fc, struct fuse_args *args, args->out_args[0 ].value = outarg; } -static int fuse_dentry_revalidate_lookup (struct fuse_mount *fm, -struct dentry *entry, -struct inode *inode, -struct fuse_entry_out *outarg, -bool *lookedup) +int fuse_dentry_revalidate_lookup (struct fuse_mount *fm, +struct dentry *entry, +struct inode *inode, +struct fuse_entry_out *outarg, +bool *lookedup) {struct dentry *parent;struct fuse_forget_link *forget;
fs/fuse/fuse_i.h +6 -0
@@ -1325,6 +1325,12 @@ void fuse_dax_dontcache(struct inode *inode, unsigned int flags);bool fuse_dax_check_alignment (struct fuse_conn *fc,unsigned int map_alignment);void fuse_dax_cancel_work (struct fuse_conn *fc); +/* dir.c */ +int fuse_dentry_revalidate_lookup (struct fuse_mount *fm,struct dentry *entry, +struct inode *inode, +struct fuse_entry_out *outarg, +bool *lookedup); +/* ioctl.c */ long fuse_file_ioctl (struct file *file,unsigned int cmd,unsigned long arg); long fuse_file_compat_ioctl(struct file *file, unsigned int cmd,
fs/fuse/inode.c +37 -6
58 lines not on this page · raw message
Signature · 1 line
2.25.1
Re: [resend PATCH v2 2/2] fuse: ensure that submounts lookup their parent
Quoted 116 lines · Krister Johansen
The submount code uses the parent nodeid passed into the function in order to create the root dentry for the new submount. This nodeid does not get its remote reference count incremented by a lookup option.
If the parent inode is evicted from its superblock, due to memory pressure for example, it can result in a forget opertation being sent to the server. Should this nodeid be forgotten while it is still in use in a submount, users of the submount get an error from the server on any subsequent access. In the author's case, this was an EBADF on all subsequent operations that needed to reference the root.
Debugging the problem revealed that the dentry shrinker triggered a forget after killing the dentry with the last reference, despite the root dentry in another superblock still using the nodeid.
As a result, a container that was also using this submount failed to access its filesystem because it had borrowed the reference instead of taking its own when setting up its superblock for the submount.
This commit fixes the problem by having the new submount trigger a lookup for the parent as part of creating a new root dentry for the virtiofsd submount superblock. This allows each superblock to have its inodes removed by the shrinker when unreferenced, while keeping the nodeid reference count accurate and active with the server.
Signed-off-by Krister Johansen <[email protected]>--- fs/fuse/dir.c | 10 +++++----- fs/fuse/fuse_i.h | 6 ++++++ fs/fuse/inode.c | 43 +++++++++++++++++++++++++++++++++++++------ 3 files changed, 48 insertions(+), 11 deletions(-)fs/fuse/dir.c +5
-5@@ -183,11 +183,11 @@ static void fuse_lookup_init(struct fuse_conn *fc, struct fuse_args *args, args->out_args[0 ].value = outarg; } -static int fuse_dentry_revalidate_lookup (struct fuse_mount *fm, -struct dentry *entry, -struct inode *inode, -struct fuse_entry_out *outarg, -bool *lookedup) +int fuse_dentry_revalidate_lookup (struct fuse_mount *fm, +struct dentry *entry, +struct inode *inode, +struct fuse_entry_out *outarg, +bool *lookedup) {struct dentry *parent;struct fuse_forget_link *forget;fs/fuse/fuse_i.h +6
-0@@ -1325,6 +1325,12 @@ void fuse_dax_dontcache(struct inode *inode, unsigned int flags);bool fuse_dax_check_alignment (struct fuse_conn *fc,unsigned int map_alignment);void fuse_dax_cancel_work (struct fuse_conn *fc); +/* dir.c */ +int fuse_dentry_revalidate_lookup (struct fuse_mount *fm,struct dentry *entry, +struct inode *inode, +struct fuse_entry_out *outarg, +bool *lookedup); +/* ioctl.c */ long fuse_file_ioctl (struct file *file,unsigned int cmd,unsigned long arg); long fuse_file_compat_ioctl(struct file *file, unsigned int cmd,fs/fuse/inode.c +22
-6@@ -1464,7 +1464,13 @@ static int fuse_fill_super_submount(struct super_block *sb,struct fuse_mount *fm =get_fuse_mount_super (sb);struct super_block *parent_sb = parent_fi->inode.i_sb;struct fuse_attr root_attr; +struct fuse_inode *fi;struct inode *root; +struct inode *parent; +struct dentry *pdent; +struct fuse_entry_out outarg; +bool lookedup = false; +int ret;fuse_sb_defaults (sb); fm->sb = sb;@@ -1480,14 +1486,39 @@ static int fuse_fill_super_submount(struct super_block *sb,if (parent_sb->s_subtype && !sb->s_subtype)return -ENOMEM ; -fuse_fill_attr_from_inode (&root_attr, parent_fi); - root =fuse_iget (sb, parent_fi->nodeid,0 , &root_attr,0 ,0 );/* -* This inode is just a duplicate, so it is not looked up and -* its nlookup should not be incremented. fuse_iget() does -* that, though, so undo it here. +* It is necessary to lookup the parent_if->nodeid in case the dentry +* that triggered the automount of the submount is later evicted. +* If this dentry is evicted without the lookup count getting increased +* on the submount root, then the server can subsequently forget this +* nodeid which leads to errors when trying to access the root of the +* submount. */ -get_fuse_inode (root)->nlookup--; + parent = &parent_fi->inode; + pdent =d_find_alias (parent); +if (!pdent) +return -EINVAL ; + + ret =fuse_dentry_revalidate_lookup (fm, pdent, parent, &outarg, + &lookedup); +dput (pdent); +/* +* The new root owns this nlookup on success, and it is incremented by
fs/fuse/inode.c static int fuse_fill_super_submount(struct super_block *sb, · line 1516
Quoted 10 lines
fs/fuse/inode.c +10
-0+* fuse_iget(). In the case the lookup succeeded but revalidate fails, +* ensure that the lookup count is tracked by the parent. +*/ +if (ret <=0 ) { +if (lookedup) { + fi =get_fuse_inode (parent); +spin_lock (&fi->lock); + fi->nlookup++; +spin_unlock (&fi->lock); + }
I might be wrong, but doesn't that mean that "get_fuse_inode(root)->nlookup--" needs to be called?
Thanks,
Bernd
Re: [resend PATCH v2 2/2] fuse: ensure that submounts lookup their parent
Quoted 120 lines · Bernd Schubert
Quoted 117 lines · Krister Johansen
The submount code uses the parent nodeid passed into the function in order to create the root dentry for the new submount. This nodeid does not get its remote reference count incremented by a lookup option.
If the parent inode is evicted from its superblock, due to memory pressure for example, it can result in a forget opertation being sent to the server. Should this nodeid be forgotten while it is still in use in a submount, users of the submount get an error from the server on any subsequent access. In the author's case, this was an EBADF on all subsequent operations that needed to reference the root.
Debugging the problem revealed that the dentry shrinker triggered a forget after killing the dentry with the last reference, despite the root dentry in another superblock still using the nodeid.
As a result, a container that was also using this submount failed to access its filesystem because it had borrowed the reference instead of taking its own when setting up its superblock for the submount.
This commit fixes the problem by having the new submount trigger a lookup for the parent as part of creating a new root dentry for the virtiofsd submount superblock. This allows each superblock to have its inodes removed by the shrinker when unreferenced, while keeping the nodeid reference count accurate and active with the server.
Signed-off-by Krister Johansen <[email protected]>--- fs/fuse/dir.c | 10 +++++----- fs/fuse/fuse_i.h | 6 ++++++ fs/fuse/inode.c | 43 +++++++++++++++++++++++++++++++++++++------ 3 files changed, 48 insertions(+), 11 deletions(-)fs/fuse/dir.c +5
-5@@ -183,11 +183,11 @@ static void fuse_lookup_init(struct fuse_conn *fc, struct fuse_args *args, args->out_args[0 ].value = outarg; } -static int fuse_dentry_revalidate_lookup (struct fuse_mount *fm, -struct dentry *entry, -struct inode *inode, -struct fuse_entry_out *outarg, -bool *lookedup) +int fuse_dentry_revalidate_lookup (struct fuse_mount *fm, +struct dentry *entry, +struct inode *inode, +struct fuse_entry_out *outarg, +bool *lookedup) {struct dentry *parent;struct fuse_forget_link *forget;fs/fuse/fuse_i.h +6
-0@@ -1325,6 +1325,12 @@ void fuse_dax_dontcache(struct inode *inode, unsigned int flags);bool fuse_dax_check_alignment (struct fuse_conn *fc,unsigned int map_alignment);void fuse_dax_cancel_work (struct fuse_conn *fc); +/* dir.c */ +int fuse_dentry_revalidate_lookup (struct fuse_mount *fm,struct dentry *entry, +struct inode *inode, +struct fuse_entry_out *outarg, +bool *lookedup); +/* ioctl.c */ long fuse_file_ioctl (struct file *file,unsigned int cmd,unsigned long arg); long fuse_file_compat_ioctl(struct file *file, unsigned int cmd,fs/fuse/inode.c +27
-6@@ -1464,7 +1464,13 @@ static int fuse_fill_super_submount(struct super_block *sb,struct fuse_mount *fm =get_fuse_mount_super (sb);struct super_block *parent_sb = parent_fi->inode.i_sb;struct fuse_attr root_attr; +struct fuse_inode *fi;struct inode *root; +struct inode *parent; +struct dentry *pdent; +struct fuse_entry_out outarg; +bool lookedup = false; +int ret;fuse_sb_defaults (sb); fm->sb = sb;@@ -1480,14 +1486,39 @@ static int fuse_fill_super_submount(struct super_block *sb,if (parent_sb->s_subtype && !sb->s_subtype)return -ENOMEM ; -fuse_fill_attr_from_inode (&root_attr, parent_fi); - root =fuse_iget (sb, parent_fi->nodeid,0 , &root_attr,0 ,0 );/* -* This inode is just a duplicate, so it is not looked up and -* its nlookup should not be incremented. fuse_iget() does -* that, though, so undo it here. +* It is necessary to lookup the parent_if->nodeid in case the dentry +* that triggered the automount of the submount is later evicted. +* If this dentry is evicted without the lookup count getting increased +* on the submount root, then the server can subsequently forget this +* nodeid which leads to errors when trying to access the root of the +* submount. */ -get_fuse_inode (root)->nlookup--; + parent = &parent_fi->inode; + pdent =d_find_alias (parent); +if (!pdent) +return -EINVAL ; + + ret =fuse_dentry_revalidate_lookup (fm, pdent, parent, &outarg, + &lookedup); +dput (pdent); +/* +* The new root owns this nlookup on success, and it is incremented by +* fuse_iget(). In the case the lookup succeeded but revalidate fails, +* ensure that the lookup count is tracked by the parent. +*/ +if (ret <=0 ) { +if (lookedup) {
Quoted 8 lines
fs/fuse/inode.c static int fuse_fill_super_submount(struct super_block *sb, · line 1516
Quoted 5 lines
fs/fuse/inode.c +5
-0+ fi =get_fuse_inode (parent); +spin_lock (&fi->lock); + fi->nlookup++; +spin_unlock (&fi->lock); + }I might be wrong, but doesn't that mean that "get_fuse_inode(root)->nlookup--" needs to be called?
In the case where ret > 0, the nlookup on get_fuse_inode(root) is set to 1 by fuse_iget(). That ensures that the root is forgotten when later unmounted. The code that handles the forget uses the count of nlookup to tell the server-side how many references to forget. (That's in fuse_evict_inode()).
However, if the fuse_dentry_revalidate_lookup() call performs a valid lookup but returns an error, this function will return before it fills out s_root in the superblock or calls fuse_iget(). If the superblock doesn't have a s_root set, then the code in generic_kill_super() won't dput() the root dentry and trigger the forget.
The intention of this code was to handle the case where the lookup had succeeded, but the code determined it was still necessary to return an error. In that situation, the reference taken by the lookup has to be accounted somewhere, and the parent seemed like a plausible candidate.
However, after writing up this response, I can see that there's still a problem here if d_make_root(root) returns NULL, because we'll also lose track of the nlookup in that case.
If you agree that charging this to the parent on error makes sense, I'll re-work the error handling here so that the right thing happens when either fuse_dentry_revalidate_lookup() or d_make_root() encounter an error.
Thanks for the feedback.
-K
Re: [resend PATCH v2 2/2] fuse: ensure that submounts lookup their parent
Quoted 142 lines · Krister Johansen
Quoted 120 lines · Bernd Schubert
Quoted 117 lines · Krister Johansen
The submount code uses the parent nodeid passed into the function in order to create the root dentry for the new submount. This nodeid does not get its remote reference count incremented by a lookup option.
If the parent inode is evicted from its superblock, due to memory pressure for example, it can result in a forget opertation being sent to the server. Should this nodeid be forgotten while it is still in use in a submount, users of the submount get an error from the server on any subsequent access. In the author's case, this was an EBADF on all subsequent operations that needed to reference the root.
Debugging the problem revealed that the dentry shrinker triggered a forget after killing the dentry with the last reference, despite the root dentry in another superblock still using the nodeid.
As a result, a container that was also using this submount failed to access its filesystem because it had borrowed the reference instead of taking its own when setting up its superblock for the submount.
This commit fixes the problem by having the new submount trigger a lookup for the parent as part of creating a new root dentry for the virtiofsd submount superblock. This allows each superblock to have its inodes removed by the shrinker when unreferenced, while keeping the nodeid reference count accurate and active with the server.
Signed-off-by Krister Johansen <[email protected]>--- fs/fuse/dir.c | 10 +++++----- fs/fuse/fuse_i.h | 6 ++++++ fs/fuse/inode.c | 43 +++++++++++++++++++++++++++++++++++++------ 3 files changed, 48 insertions(+), 11 deletions(-)fs/fuse/dir.c +5
-5@@ -183,11 +183,11 @@ static void fuse_lookup_init(struct fuse_conn *fc, struct fuse_args *args, args->out_args[0 ].value = outarg; } -static int fuse_dentry_revalidate_lookup (struct fuse_mount *fm, -struct dentry *entry, -struct inode *inode, -struct fuse_entry_out *outarg, -bool *lookedup) +int fuse_dentry_revalidate_lookup (struct fuse_mount *fm, +struct dentry *entry, +struct inode *inode, +struct fuse_entry_out *outarg, +bool *lookedup) {struct dentry *parent;struct fuse_forget_link *forget;fs/fuse/fuse_i.h +6
-0@@ -1325,6 +1325,12 @@ void fuse_dax_dontcache(struct inode *inode, unsigned int flags);bool fuse_dax_check_alignment (struct fuse_conn *fc,unsigned int map_alignment);void fuse_dax_cancel_work (struct fuse_conn *fc); +/* dir.c */ +int fuse_dentry_revalidate_lookup (struct fuse_mount *fm,struct dentry *entry, +struct inode *inode, +struct fuse_entry_out *outarg, +bool *lookedup); +/* ioctl.c */ long fuse_file_ioctl (struct file *file,unsigned int cmd,unsigned long arg); long fuse_file_compat_ioctl(struct file *file, unsigned int cmd,fs/fuse/inode.c +27
-6@@ -1464,7 +1464,13 @@ static int fuse_fill_super_submount(struct super_block *sb,struct fuse_mount *fm =get_fuse_mount_super (sb);struct super_block *parent_sb = parent_fi->inode.i_sb;struct fuse_attr root_attr; +struct fuse_inode *fi;struct inode *root; +struct inode *parent; +struct dentry *pdent; +struct fuse_entry_out outarg; +bool lookedup = false; +int ret;fuse_sb_defaults (sb); fm->sb = sb;@@ -1480,14 +1486,39 @@ static int fuse_fill_super_submount(struct super_block *sb,if (parent_sb->s_subtype && !sb->s_subtype)return -ENOMEM ; -fuse_fill_attr_from_inode (&root_attr, parent_fi); - root =fuse_iget (sb, parent_fi->nodeid,0 , &root_attr,0 ,0 );/* -* This inode is just a duplicate, so it is not looked up and -* its nlookup should not be incremented. fuse_iget() does -* that, though, so undo it here. +* It is necessary to lookup the parent_if->nodeid in case the dentry +* that triggered the automount of the submount is later evicted. +* If this dentry is evicted without the lookup count getting increased +* on the submount root, then the server can subsequently forget this +* nodeid which leads to errors when trying to access the root of the +* submount. */ -get_fuse_inode (root)->nlookup--; + parent = &parent_fi->inode; + pdent =d_find_alias (parent); +if (!pdent) +return -EINVAL ; + + ret =fuse_dentry_revalidate_lookup (fm, pdent, parent, &outarg, + &lookedup); +dput (pdent); +/* +* The new root owns this nlookup on success, and it is incremented by +* fuse_iget(). In the case the lookup succeeded but revalidate fails, +* ensure that the lookup count is tracked by the parent. +*/ +if (ret <=0 ) { +if (lookedup) {Quoted 8 lines
fs/fuse/inode.c static int fuse_fill_super_submount(struct super_block *sb, · line 1516
Quoted 5 lines
fs/fuse/inode.c +5
-0+ fi =get_fuse_inode (parent); +spin_lock (&fi->lock); + fi->nlookup++; +spin_unlock (&fi->lock); + }I might be wrong, but doesn't that mean that "get_fuse_inode(root)->nlookup--" needs to be called?
In the case where ret > 0, the nlookup on
get_fuse_inode(root)is set to 1 byfuse_iget(). That ensures that the root is forgotten when later unmounted. The code that handles the forget uses the count of nlookup to tell the server-side how many references to forget. (That's infuse_evict_inode()).However, if the
fuse_dentry_revalidate_lookup()call performs a valid lookup but returns an error, this function will return before it fills outs_rootin the superblock or callsfuse_iget(). If the superblock doesn't have as_rootset, then the code ingeneric_kill_super()won'tdput()the root dentry and trigger the forget.
Quoted 4 lines
The intention of this code was to handle the case where the lookup had succeeded, but the code determined it was still necessary to return an error. In that situation, the reference taken by the lookup has to be accounted somewhere, and the parent seemed like a plausible candidate.
Yeah sorry, I had just missed that fuse_iget() also moved and then thought it would have increased fi->nlookup already.
Quoted 9 lines
However, after writing up this response, I can see that there's still a problem here if
d_make_root(root)returns NULL, because we'll also lose track of the nlookup in that case.If you agree that charging this to the parent on error makes sense, I'll re-work the error handling here so that the right thing happens when either
fuse_dentry_revalidate_lookup()ord_make_root()encounter an error.
Oh yeah, I also missed that. Although, iput() calls iput_final, which then calls evict and sends the fuse forget - isn't that the right action already?
Quoted 2 lines
Thanks for the feedback.
Well, false alarm from my side, sorry again!
Bernd
Re: [resend PATCH v2 2/2] fuse: ensure that submounts lookup their parent
Quoted 145 lines · Bernd Schubert
Quoted 142 lines · Krister Johansen
Quoted 120 lines · Bernd Schubert
Quoted 117 lines · Krister Johansen
The submount code uses the parent nodeid passed into the function in order to create the root dentry for the new submount. This nodeid does not get its remote reference count incremented by a lookup option.
If the parent inode is evicted from its superblock, due to memory pressure for example, it can result in a forget opertation being sent to the server. Should this nodeid be forgotten while it is still in use in a submount, users of the submount get an error from the server on any subsequent access. In the author's case, this was an EBADF on all subsequent operations that needed to reference the root.
Debugging the problem revealed that the dentry shrinker triggered a forget after killing the dentry with the last reference, despite the root dentry in another superblock still using the nodeid.
As a result, a container that was also using this submount failed to access its filesystem because it had borrowed the reference instead of taking its own when setting up its superblock for the submount.
This commit fixes the problem by having the new submount trigger a lookup for the parent as part of creating a new root dentry for the virtiofsd submount superblock. This allows each superblock to have its inodes removed by the shrinker when unreferenced, while keeping the nodeid reference count accurate and active with the server.
Signed-off-by Krister Johansen <[email protected]>--- fs/fuse/dir.c | 10 +++++----- fs/fuse/fuse_i.h | 6 ++++++ fs/fuse/inode.c | 43 +++++++++++++++++++++++++++++++++++++------ 3 files changed, 48 insertions(+), 11 deletions(-)fs/fuse/dir.c +5
-5@@ -183,11 +183,11 @@ static void fuse_lookup_init(struct fuse_conn *fc, struct fuse_args *args, args->out_args[0 ].value = outarg; } -static int fuse_dentry_revalidate_lookup (struct fuse_mount *fm, -struct dentry *entry, -struct inode *inode, -struct fuse_entry_out *outarg, -bool *lookedup) +int fuse_dentry_revalidate_lookup (struct fuse_mount *fm, +struct dentry *entry, +struct inode *inode, +struct fuse_entry_out *outarg, +bool *lookedup) {struct dentry *parent;struct fuse_forget_link *forget;fs/fuse/fuse_i.h +6
-0@@ -1325,6 +1325,12 @@ void fuse_dax_dontcache(struct inode *inode, unsigned int flags);bool fuse_dax_check_alignment (struct fuse_conn *fc,unsigned int map_alignment);void fuse_dax_cancel_work (struct fuse_conn *fc); +/* dir.c */ +int fuse_dentry_revalidate_lookup (struct fuse_mount *fm,struct dentry *entry, +struct inode *inode, +struct fuse_entry_out *outarg, +bool *lookedup); +/* ioctl.c */ long fuse_file_ioctl (struct file *file,unsigned int cmd,unsigned long arg); long fuse_file_compat_ioctl(struct file *file, unsigned int cmd,fs/fuse/inode.c +27
-6@@ -1464,7 +1464,13 @@ static int fuse_fill_super_submount(struct super_block *sb,struct fuse_mount *fm =get_fuse_mount_super (sb);struct super_block *parent_sb = parent_fi->inode.i_sb;struct fuse_attr root_attr; +struct fuse_inode *fi;struct inode *root; +struct inode *parent; +struct dentry *pdent; +struct fuse_entry_out outarg; +bool lookedup = false; +int ret;fuse_sb_defaults (sb); fm->sb = sb;@@ -1480,14 +1486,39 @@ static int fuse_fill_super_submount(struct super_block *sb,if (parent_sb->s_subtype && !sb->s_subtype)return -ENOMEM ; -fuse_fill_attr_from_inode (&root_attr, parent_fi); - root =fuse_iget (sb, parent_fi->nodeid,0 , &root_attr,0 ,0 );/* -* This inode is just a duplicate, so it is not looked up and -* its nlookup should not be incremented. fuse_iget() does -* that, though, so undo it here. +* It is necessary to lookup the parent_if->nodeid in case the dentry +* that triggered the automount of the submount is later evicted. +* If this dentry is evicted without the lookup count getting increased +* on the submount root, then the server can subsequently forget this +* nodeid which leads to errors when trying to access the root of the +* submount. */ -get_fuse_inode (root)->nlookup--; + parent = &parent_fi->inode; + pdent =d_find_alias (parent); +if (!pdent) +return -EINVAL ; + + ret =fuse_dentry_revalidate_lookup (fm, pdent, parent, &outarg, + &lookedup); +dput (pdent); +/* +* The new root owns this nlookup on success, and it is incremented by +* fuse_iget(). In the case the lookup succeeded but revalidate fails, +* ensure that the lookup count is tracked by the parent. +*/ +if (ret <=0 ) { +if (lookedup) {Quoted 8 lines
fs/fuse/inode.c static int fuse_fill_super_submount(struct super_block *sb, · line 1516
Quoted 5 lines
fs/fuse/inode.c +5
-0+ fi =get_fuse_inode (parent); +spin_lock (&fi->lock); + fi->nlookup++; +spin_unlock (&fi->lock); + }I might be wrong, but doesn't that mean that "get_fuse_inode(root)->nlookup--" needs to be called?
In the case where ret > 0, the nlookup on
get_fuse_inode(root)is set to 1 byfuse_iget(). That ensures that the root is forgotten when later unmounted. The code that handles the forget uses the count of nlookup to tell the server-side how many references to forget. (That's infuse_evict_inode()).However, if the
fuse_dentry_revalidate_lookup()call performs a valid lookup but returns an error, this function will return before it fills outs_rootin the superblock or callsfuse_iget(). If the superblock doesn't have as_rootset, then the code ingeneric_kill_super()won'tdput()the root dentry and trigger the forget.
Quoted 7 lines
Quoted 4 lines
The intention of this code was to handle the case where the lookup had succeeded, but the code determined it was still necessary to return an error. In that situation, the reference taken by the lookup has to be accounted somewhere, and the parent seemed like a plausible candidate.
Yeah sorry, I had just missed that
fuse_iget()also moved and then thought it would have increasedfi->nlookupalready.
No worries; I'd much rather get feedback if something doesn't look right, even if it turns out okay in the end.
Quoted 11 lines
Quoted 8 lines
However, after writing up this response, I can see that there's still a problem here if
d_make_root(root)returns NULL, because we'll also lose track of the nlookup in that case.If you agree that charging this to the parent on error makes sense, I'll re-work the error handling here so that the right thing happens when either
fuse_dentry_revalidate_lookup()ord_make_root()encounter an error.Oh yeah, I also missed that. Although,
iput()callsiput_final, which then calls evict and sends the fuse forget - isn't that the right action already?
Thanks, I had forgotten that d_make_root() would call iput() for me if d_alloc_anon() fails. Let me restate this to suggest that I account the nlookup to the parent if fuse_dentry_revalidate_lookup() or fuse_iget() fail instead. Does that sound right?
Quoted 3 lines
Quoted 1 line
Thanks for the feedback.
Well, false alarm from my side, sorry again!
No apology necessary; I appreciate you spending the time to look and ask questions.
-K
Re: [resend PATCH v2 2/2] fuse: ensure that submounts lookup their parent
Quoted 166 lines · Krister Johansen
Quoted 145 lines · Bernd Schubert
Quoted 142 lines · Krister Johansen
Quoted 120 lines · Bernd Schubert
Quoted 117 lines · Krister Johansen
The submount code uses the parent nodeid passed into the function in order to create the root dentry for the new submount. This nodeid does not get its remote reference count incremented by a lookup option.
If the parent inode is evicted from its superblock, due to memory pressure for example, it can result in a forget opertation being sent to the server. Should this nodeid be forgotten while it is still in use in a submount, users of the submount get an error from the server on any subsequent access. In the author's case, this was an EBADF on all subsequent operations that needed to reference the root.
Debugging the problem revealed that the dentry shrinker triggered a forget after killing the dentry with the last reference, despite the root dentry in another superblock still using the nodeid.
As a result, a container that was also using this submount failed to access its filesystem because it had borrowed the reference instead of taking its own when setting up its superblock for the submount.
This commit fixes the problem by having the new submount trigger a lookup for the parent as part of creating a new root dentry for the virtiofsd submount superblock. This allows each superblock to have its inodes removed by the shrinker when unreferenced, while keeping the nodeid reference count accurate and active with the server.
Signed-off-by Krister Johansen <[email protected]>--- fs/fuse/dir.c | 10 +++++----- fs/fuse/fuse_i.h | 6 ++++++ fs/fuse/inode.c | 43 +++++++++++++++++++++++++++++++++++++------ 3 files changed, 48 insertions(+), 11 deletions(-)fs/fuse/dir.c +5
-5@@ -183,11 +183,11 @@ static void fuse_lookup_init(struct fuse_conn *fc, struct fuse_args *args, args->out_args[0 ].value = outarg; } -static int fuse_dentry_revalidate_lookup (struct fuse_mount *fm, -struct dentry *entry, -struct inode *inode, -struct fuse_entry_out *outarg, -bool *lookedup) +int fuse_dentry_revalidate_lookup (struct fuse_mount *fm, +struct dentry *entry, +struct inode *inode, +struct fuse_entry_out *outarg, +bool *lookedup) {struct dentry *parent;struct fuse_forget_link *forget;fs/fuse/fuse_i.h +6
-0@@ -1325,6 +1325,12 @@ void fuse_dax_dontcache(struct inode *inode, unsigned int flags);bool fuse_dax_check_alignment (struct fuse_conn *fc,unsigned int map_alignment);void fuse_dax_cancel_work (struct fuse_conn *fc); +/* dir.c */ +int fuse_dentry_revalidate_lookup (struct fuse_mount *fm,struct dentry *entry, +struct inode *inode, +struct fuse_entry_out *outarg, +bool *lookedup); +/* ioctl.c */ long fuse_file_ioctl (struct file *file,unsigned int cmd,unsigned long arg); long fuse_file_compat_ioctl(struct file *file, unsigned int cmd,fs/fuse/inode.c +27
-6@@ -1464,7 +1464,13 @@ static int fuse_fill_super_submount(struct super_block *sb,struct fuse_mount *fm =get_fuse_mount_super (sb);struct super_block *parent_sb = parent_fi->inode.i_sb;struct fuse_attr root_attr; +struct fuse_inode *fi;struct inode *root; +struct inode *parent; +struct dentry *pdent; +struct fuse_entry_out outarg; +bool lookedup = false; +int ret;fuse_sb_defaults (sb); fm->sb = sb;@@ -1480,14 +1486,39 @@ static int fuse_fill_super_submount(struct super_block *sb,if (parent_sb->s_subtype && !sb->s_subtype)return -ENOMEM ; -fuse_fill_attr_from_inode (&root_attr, parent_fi); - root =fuse_iget (sb, parent_fi->nodeid,0 , &root_attr,0 ,0 );/* -* This inode is just a duplicate, so it is not looked up and -* its nlookup should not be incremented. fuse_iget() does -* that, though, so undo it here. +* It is necessary to lookup the parent_if->nodeid in case the dentry +* that triggered the automount of the submount is later evicted. +* If this dentry is evicted without the lookup count getting increased +* on the submount root, then the server can subsequently forget this +* nodeid which leads to errors when trying to access the root of the +* submount. */ -get_fuse_inode (root)->nlookup--; + parent = &parent_fi->inode; + pdent =d_find_alias (parent); +if (!pdent) +return -EINVAL ; + + ret =fuse_dentry_revalidate_lookup (fm, pdent, parent, &outarg, + &lookedup); +dput (pdent); +/* +* The new root owns this nlookup on success, and it is incremented by +* fuse_iget(). In the case the lookup succeeded but revalidate fails, +* ensure that the lookup count is tracked by the parent. +*/ +if (ret <=0 ) { +if (lookedup) {Quoted 8 lines
fs/fuse/inode.c static int fuse_fill_super_submount(struct super_block *sb, · line 1516
Quoted 5 lines
fs/fuse/inode.c +5
-0+ fi =get_fuse_inode (parent); +spin_lock (&fi->lock); + fi->nlookup++; +spin_unlock (&fi->lock); + }I might be wrong, but doesn't that mean that "get_fuse_inode(root)->nlookup--" needs to be called?
In the case where ret > 0, the nlookup on
get_fuse_inode(root)is set to 1 byfuse_iget(). That ensures that the root is forgotten when later unmounted. The code that handles the forget uses the count of nlookup to tell the server-side how many references to forget. (That's infuse_evict_inode()).However, if the
fuse_dentry_revalidate_lookup()call performs a valid lookup but returns an error, this function will return before it fills outs_rootin the superblock or callsfuse_iget(). If the superblock doesn't have as_rootset, then the code ingeneric_kill_super()won'tdput()the root dentry and trigger the forget.Quoted 7 lines
Quoted 4 lines
The intention of this code was to handle the case where the lookup had succeeded, but the code determined it was still necessary to return an error. In that situation, the reference taken by the lookup has to be accounted somewhere, and the parent seemed like a plausible candidate.
Yeah sorry, I had just missed that
fuse_iget()also moved and then thought it would have increasedfi->nlookupalready.No worries; I'd much rather get feedback if something doesn't look right, even if it turns out okay in the end.
Quoted 9 lines
Quoted 8 lines
However, after writing up this response, I can see that there's still a problem here if
d_make_root(root)returns NULL, because we'll also lose track of the nlookup in that case.If you agree that charging this to the parent on error makes sense, I'll re-work the error handling here so that the right thing happens when either
fuse_dentry_revalidate_lookup()ord_make_root()encounter an error.
Quoted 7 lines
Quoted 2 lines
Oh yeah, I also missed that. Although,
iput()callsiput_final, which then calls evict and sends the fuse forget - isn't that the right action already?Thanks, I had forgotten that
d_make_root()would calliput()for me ifd_alloc_anon()fails. Let me restate this to suggest that I account the nlookup to the parent iffuse_dentry_revalidate_lookup()orfuse_iget()fail instead. Does that sound right?
Hmm, so server/daemon side uses the lookup count to have an inode reference - are you sure that parent is the right inode for the forget call? And what is the probability for such failures? I.e. is that performance critical? Wouldn't be much simpler and clearer to just avoid and doubt and to send an immediate forget?
Thanks,
Bernd
Re: [resend PATCH v2 2/2] fuse: ensure that submounts lookup their parent
Quoted 11 lines · Bernd Schubert
Quoted 4 lines · Krister Johansen
Thanks, I had forgotten that
d_make_root()would calliput()for me ifd_alloc_anon()fails. Let me restate this to suggest that I account the nlookup to the parent iffuse_dentry_revalidate_lookup()orfuse_iget()fail instead. Does that sound right?Hmm, so server/daemon side uses the lookup count to have an inode reference
- are you sure that parent is the right inode for the forget call? And what is the probability for such failures? I.e. is that performance critical? Wouldn't be much simpler and clearer to just avoid and doubt and to send an immediate forget?
Yeah, the server / daemon side need to track the lookup count so that it knows when it can close the fd for the file on the server-side. (At least for virtiofsd, anyway.).
The reason I had avoided doing the forget in the submount code is that it needs a forget linkage in order to call fuse_queue_forget(). One of these is allocated by fuse_alloc_inode(). A well formed parent should always have one. However, if the fuse_iget() for the submount root fails, then there's no linkage to borrow from the new inode. The code could always call fuse_alloc_forget() directly, like is done elsewhere. I thought it might be hard to get the memory for this allocation if fuse_iget() also can't allocate enough, but I could move the allocation earlier in the function and just free it if it's not used.
I'm not confident that would reduce the amount of code in the function, but if you'd find it clearer, I'm happy to modify it accordingly.
-K
Miklos Szeredi
maintainerRe: [resend PATCH v2 2/2] fuse: ensure that submounts lookup their parent
In reply to Krister JohansenQuoted 12 lines · Krister Johansen
The submount code uses the parent nodeid passed into the function in order to create the root dentry for the new submount. This nodeid does not get its remote reference count incremented by a lookup option.
If the parent inode is evicted from its superblock, due to memory pressure for example, it can result in a forget opertation being sent to the server. Should this nodeid be forgotten while it is still in use in a submount, users of the submount get an error from the server on any subsequent access. In the author's case, this was an EBADF on all subsequent operations that needed to reference the root.
Quoted 3 lines
Debugging the problem revealed that the dentry shrinker triggered a forget after killing the dentry with the last reference, despite the root dentry in another superblock still using the nodeid.
There's some context missing here. There are two dentries: a mount point in the parent mount and the root of the submount.
The server indicates that the looked up inode is a submount using FUSE_ATTR_SUBMOUNT. Then AFAICS the following happens:
1) the mountpoint dentry is created with nlookup = 1. TheS_AUTOMOUNT flag is set on the mountpoint inode.
2) the lookup code sees S_AUTOMOUNT and triggers the submount
operation, which sets up the new super_block and the root dentry with the user supplied nodeid and with nlookup = 0 (because it wasn't actually looked up).
How the automount gets torn down is another story. You say that the mount point gets evicted due to memory pressure. But it can't get evicted while the submount is attached. So the submount must first
get detached, and then the mount point can be reclaimed. The
question is: how does the submount gets detached. Do you have an idea?
Thanks,
Miklos
Re: [resend PATCH v2 2/2] fuse: ensure that submounts lookup their parent
Quoted 31 lines · Miklos Szeredi
Quoted 12 lines · Krister Johansen
The submount code uses the parent nodeid passed into the function in order to create the root dentry for the new submount. This nodeid does not get its remote reference count incremented by a lookup option.
If the parent inode is evicted from its superblock, due to memory pressure for example, it can result in a forget opertation being sent to the server. Should this nodeid be forgotten while it is still in use in a submount, users of the submount get an error from the server on any subsequent access. In the author's case, this was an EBADF on all subsequent operations that needed to reference the root.
Quoted 3 lines
Debugging the problem revealed that the dentry shrinker triggered a forget after killing the dentry with the last reference, despite the root dentry in another superblock still using the nodeid.
There's some context missing here. There are two dentries: a mount point in the parent mount and the root of the submount.
The server indicates that the looked up inode is a submount using
FUSE_ATTR_SUBMOUNT. Then AFAICS the following happens:1) the mountpoint dentry is created with nlookup = 1. The
S_AUTOMOUNTflag is set on the mountpoint inode.2) the lookup code sees
S_AUTOMOUNTand triggers the submount
operation, which sets up the newsuper_blockand the root dentry with the user supplied nodeid and with nlookup = 0 (because it wasn't actually looked up).
Quoted 6 lines
How the automount gets torn down is another story. You say that the mount point gets evicted due to memory pressure. But it can't get evicted while the submount is attached. So the submount must first
get detached, and then the mount point can be reclaimed. The
question is: how does the submount gets detached. Do you have an idea?
Apologies for not stating this clearly. The use case is a container running in a VM, and the container's root is provided to the guest via virtiofs. I believe the submount is getting detached as part of the container setup, either via a umount2(MNT_DETACH) of the old root filesystem, or as part of pivot_root() itself. By the time I'm able to inspect the dentry associated with the submount in the initial mount ns (case #1) its d_lockref.count is 0, and /proc/mountinfo doesn't show an active mount for the submount in that mount namespace.
If I manually traverse the path to the submount via something like cd and ls from the initial mount namespace, it'll stay referenced until I run a umount for the automounted path. I'm reasonably sure it's the container setup that's causing the detaching.
I'm happy to go debug this some more, though, if you're skeptical of the explanation.
-K
Miklos Szeredi
maintainerRe: [resend PATCH v2 2/2] fuse: ensure that submounts lookup their parent
Quoted 4 lines · Krister Johansen
If I manually traverse the path to the submount via something like cd and ls from the initial mount namespace, it'll stay referenced until I run a umount for the automounted path. I'm reasonably sure it's the container setup that's causing the detaching.
Okay. Can you please try the attached test patch. It's not a proper solution, but I think it's the right direction.
Thanks,
Miklos
fs/fuse/inode.c +12 -0
@@ -1524,6 +1524,18 @@ static int fuse_get_tree_submount(struct fs_context *fsc)return err; } +spin_lock (&mp_fi->lock); +if (mp_fi->nlookup) { +struct fuse_inode *fi =get_fuse_inode (d_inode (sb->s_root)); + mp_fi->nlookup--; +spin_unlock (&mp_fi->lock); +spin_lock (&fi->lock); + fi->nlookup++; +spin_unlock (&fi->lock); + }else { +spin_unlock (&mp_fi->lock); + } +down_write (&fc->killsb);list_add_tail (&fm->fc_entry, &fc->mounts);up_write (&fc->killsb);
Re: [resend PATCH v2 2/2] fuse: ensure that submounts lookup their parent
Hi Miklos,
Quoted 9 lines · Miklos Szeredi
Quoted 4 lines · Krister Johansen
If I manually traverse the path to the submount via something like cd and ls from the initial mount namespace, it'll stay referenced until I run a umount for the automounted path. I'm reasonably sure it's the container setup that's causing the detaching.
Okay. Can you please try the attached test patch. It's not a proper solution, but I think it's the right direction.
Thanks, I tested this patch and was unable to reproduce the scenario where an OOM resulted in the submount from the guest in the guest getting an EBADF from virtiofsd. (I did generate OOMs, though).
I am curious what you have in mind in order to move this towards a proper fix? I shied away from the approach of stealing a nlookup from mp_fi beacuse it wasn't clear that I could always count on the nlookup in the parent staying positive. E.g. I was afraid I was either going to not have enough nlookups to move to submounts, or trigger a forget from an exiting container that leads to an EBADF from the initial mount namespace.
-K
Quoted 23 lines
fs/fuse/inode.c +12
-0@@ -1524,6 +1524,18 @@ static int fuse_get_tree_submount(struct fs_context *fsc)return err; } +spin_lock (&mp_fi->lock); +if (mp_fi->nlookup) { +struct fuse_inode *fi =get_fuse_inode (d_inode (sb->s_root)); + mp_fi->nlookup--; +spin_unlock (&mp_fi->lock); +spin_lock (&fi->lock); + fi->nlookup++; +spin_unlock (&fi->lock); + }else { +spin_unlock (&mp_fi->lock); + } +down_write (&fc->killsb);list_add_tail (&fm->fc_entry, &fc->mounts);up_write (&fc->killsb);
Miklos Szeredi
maintainerRe: [resend PATCH v2 2/2] fuse: ensure that submounts lookup their parent
Quoted 7 lines · Krister Johansen
I am curious what you have in mind in order to move this towards a proper fix? I shied away from the approach of stealing a nlookup from
mp_fibeacuse it wasn't clear that I could always count on the nlookup in the parent staying positive. E.g. I was afraid I was either going to not have enough nlookups to move to submounts, or trigger a forget from an exiting container that leads to an EBADF from the initial mount namespace.
One idea is to transfer the nlookup to a separately refcounted object that is referenced from mp_fi as well as all the submounts.
Thanks,
Miklos
Re: [resend PATCH v2 2/2] fuse: ensure that submounts lookup their parent
Quoted 10 lines · Miklos Szeredi
Quoted 7 lines · Krister Johansen
I am curious what you have in mind in order to move this towards a proper fix? I shied away from the approach of stealing a nlookup from
mp_fibeacuse it wasn't clear that I could always count on the nlookup in the parent staying positive. E.g. I was afraid I was either going to not have enough nlookups to move to submounts, or trigger a forget from an exiting container that leads to an EBADF from the initial mount namespace.
Quoted 2 lines
One idea is to transfer the nlookup to a separately refcounted object that is referenced from
mp_fias well as all the submounts.
That seems possible. Would the idea be to move all tracking of nlookup to a separate refcounted object for the particular nodeid, or just do this for the first lookup of a submount?
Would you like me to put together a v3 that heads this direction?
Thanks,
-K
Miklos Szeredi
maintainerRe: [resend PATCH v2 2/2] fuse: ensure that submounts lookup their parent
Quoted 12 lines · Krister Johansen
Quoted 10 lines · Miklos Szeredi
Quoted 7 lines · Krister Johansen
I am curious what you have in mind in order to move this towards a proper fix? I shied away from the approach of stealing a nlookup from
mp_fibeacuse it wasn't clear that I could always count on the nlookup in the parent staying positive. E.g. I was afraid I was either going to not have enough nlookups to move to submounts, or trigger a forget from an exiting container that leads to an EBADF from the initial mount namespace.
Quoted 6 lines
Quoted 2 lines
One idea is to transfer the nlookup to a separately refcounted object that is referenced from
mp_fias well as all the submounts.That seems possible. Would the idea be to move all tracking of nlookup to a separate refcounted object for the particular nodeid, or just do this for the first lookup of a submount?
Just for submounts. And yes, it should work if the count from the first lookup is transferred to this object (fuse_iget()) and subsequent counts (fuse_dentry_revalidate()) go to the mountpoint inode as usual. This will result in more than one FORGET in most cases, but that's okay.
Quoted 1 line
Would you like me to put together a v3 that heads this direction?
That would be great, thanks.
Miklos
Re: [resend PATCH v2 2/2] fuse: ensure that submounts lookup their parent
Hi Miklos,
Quoted 26 lines · Miklos Szeredi
Quoted 12 lines · Krister Johansen
Quoted 10 lines · Miklos Szeredi
Quoted 7 lines · Krister Johansen
I am curious what you have in mind in order to move this towards a proper fix? I shied away from the approach of stealing a nlookup from
mp_fibeacuse it wasn't clear that I could always count on the nlookup in the parent staying positive. E.g. I was afraid I was either going to not have enough nlookups to move to submounts, or trigger a forget from an exiting container that leads to an EBADF from the initial mount namespace.Quoted 6 lines
Quoted 2 lines
One idea is to transfer the nlookup to a separately refcounted object that is referenced from
mp_fias well as all the submounts.That seems possible. Would the idea be to move all tracking of nlookup to a separate refcounted object for the particular nodeid, or just do this for the first lookup of a submount?
Just for submounts. And yes, it should work if the count from the first lookup is transferred to this object (
fuse_iget()) and subsequent counts (fuse_dentry_revalidate()) go to the mountpoint inode as usual. This will result in more than one FORGET in most cases, but that's okay.
Quoted 3 lines
Quoted 1 line
Would you like me to put together a v3 that heads this direction?
That would be great, thanks.
Thanks for the pointers here. I started over and followed the approach that you suggested. It condensed to a single patch, so I'll send it as a follow-up to this thread.
-K
PATCH v3 1/1 fuse: share lookup state between submount and its parent
In reply to Miklos SzerediFuse submounts do not perform a lookup for the nodeid that they inherit from their parent. Instead, the code decrements the nlookup on the submount's fuse_inode when it is instantiated, and no forget is performed when a submount root is evicted.
Trouble arises when the submount's parent is evicted despite the submount itself being in use. In this author's case, the submount was in a container and deatched from the initial mount namespace via a MNT_DEATCH operation. When memory pressure triggered the shrinker, the inode from the parent was evicted, which triggered enough forgets to render the submount's nodeid invalid.
Since submounts should still function, even if their parent goes away, solve this problem by sharing refcounted state between the parent and its submount. When all of the references on this shared state reach zero, it's safe to forget the final lookup of the fuse nodeid.
--- fs/fuse/fuse_i.h | 20 +++++++++++ fs/fuse/inode.c | 88 ++++++++++++++++++++++++++++++++++++++++++++++-- 2 files changed, 105 insertions(+), 3 deletions(-)
fs/fuse/fuse_i.h +20 -0
@@ -63,6 +63,24 @@ struct fuse_forget_link {struct fuse_forget_link *next; }; +/* Submount lookup tracking */ +struct fuse_submount_lookup { +/** Refcount */ +refcount_t count; + +/** Unique ID, which identifies the inode between userspace +* and kernel */ +u64 nodeid; + +/** Number of lookups on this inode */ +u64 nlookup; + +/** The request used for sending the FORGET message */ +struct fuse_forget_link *forget; + +struct rcu_head rcu; +}; +/** FUSE inode */ struct fuse_inode {/** Inode data */
@@ -158,6 +176,8 @@ struct fuse_inode {*/ struct fuse_inode_dax *dax;#endif +/** Submount specific lookup tracking */ +struct fuse_submount_lookup *submount_lookup; };/** FUSE inode state bits */
fs/fuse/inode.c +85 -3
153 lines not on this page · raw message
Signature · 1 line
2.25.1
Re: [PATCH v3] fuse: share lookup state between submount and its parent
Quoted 35 lines · Krister Johansen
Fuse submounts do not perform a lookup for the nodeid that they inherit from their parent. Instead, the code decrements the nlookup on the submount's
fuse_inodewhen it is instantiated, and no forget is performed when a submount root is evicted.Trouble arises when the submount's parent is evicted despite the submount itself being in use. In this author's case, the submount was in a container and deatched from the initial mount namespace via a
MNT_DEATCHoperation. When memory pressure triggered the shrinker, the inode from the parent was evicted, which triggered enough forgets to render the submount's nodeid invalid.Since submounts should still function, even if their parent goes away, solve this problem by sharing refcounted state between the parent and its submount. When all of the references on this shared state reach zero, it's safe to forget the final lookup of the fuse nodeid.
Signed-off-by Krister Johansen <[email protected]>Fixes 1866d779d5d2 ("fuse: Allow fuse_fill_super_common() for submounts")--- fs/fuse/fuse_i.h | 20 +++++++++++ fs/fuse/inode.c | 88 ++++++++++++++++++++++++++++++++++++++++++++++-- 2 files changed, 105 insertions(+), 3 deletions(-)fs/fuse/fuse_i.h +1
-0@@ -63,6 +63,24 @@ struct fuse_forget_link {struct fuse_forget_link *next; }; +/* Submount lookup tracking */
fs/fuse/fuse_i.h struct fuse_forget_link { · line 76
Quoted 10 lines
fs/fuse/fuse_i.h +10
-0+struct fuse_submount_lookup { +/** Refcount */ +refcount_t count; + +/** Unique ID, which identifies the inode between userspace +* and kernel */ +u64 nodeid; + +/** Number of lookups on this inode */ +u64 nlookup;
sl->nlookup will always be one. So that can just be implicit and this field can just go away.
fs/fuse/fuse_i.h struct fuse_forget_link { · line 81
Quoted 5 lines
fs/fuse/fuse_i.h +5
-0+ +/** The request used for sending the FORGET message */ +struct fuse_forget_link *forget; + +struct rcu_head rcu;
RCU would be needed if any fields could be accessed from RCU protected code. But AFAICS there's no such access, so this shouldn't be needed.
Am I missing something?
Quoted 69 lines
fs/fuse/fuse_i.h +4
-0+}; +/** FUSE inode */ struct fuse_inode {/** Inode data */ @@ -158,6 +176,8 @@ struct fuse_inode {*/ struct fuse_inode_dax *dax;#endif +/** Submount specific lookup tracking */ +struct fuse_submount_lookup *submount_lookup; };/** FUSE inode state bits */ fs/fuse/inode.c +33
-0@@ -68,6 +68,24 @@ struct fuse_forget_link *fuse_alloc_forget(void)return kzalloc (sizeof (struct fuse_forget_link ),GFP_KERNEL_ACCOUNT ); } +static struct fuse_submount_lookup *fuse_alloc_submount_lookup (void ) +{ +struct fuse_submount_lookup *sl; + + sl =kzalloc (sizeof (struct fuse_submount_lookup ),GFP_KERNEL_ACCOUNT ); +if (!sl) +return NULL ; + sl->forget =fuse_alloc_forget (); +if (!sl->forget) + goto out_free; + +return sl; + +out_free: +kfree (sl); +return NULL ; +} +static struct inode *fuse_alloc_inode (struct super_block *sb) {struct fuse_inode *fi;@@ -113,9 +131,24 @@ static void fuse_free_inode(struct inode *inode)kmem_cache_free (fuse_inode_cachep, fi); } +static void fuse_cleanup_submount_lookup (struct fuse_conn *fc, +struct fuse_submount_lookup *sl) +{ +if (!refcount_dec_and_test (&sl->count)) +return ; + +if (sl->nlookup) { +fuse_queue_forget (fc, sl->forget, sl->nodeid, sl->nlookup); + sl->forget =NULL ; + } +kfree (sl->forget); +kfree_rcu (sl, rcu); +} +static void fuse_evict_inode (struct inode *inode) {struct fuse_inode *fi =get_fuse_inode (inode); +struct fuse_submount_lookup *sl =NULL ;/* Will write inode on close/munmap and in all other dirtiers */ WARN_ON (inode->i_state &I_DIRTY_INODE );
fs/fuse/inode.c static void fuse_evict_inode(struct inode *inode) · line 174
Quoted 10 lines
fs/fuse/inode.c +7
-0@@ -132,6 +165,15 @@ static void fuse_evict_inode(struct inode *inode) fi->nlookup); fi->forget =NULL ; } + +spin_lock (&fi->lock); +if (fi->submount_lookup) { + sl = fi->submount_lookup; + fi->submount_lookup =NULL ; + } +spin_unlock (&fi->lock);
I don't think locking is needed. Eviction happens only once and at that point nobody else should be touching the inode.
Quoted 76 lines
fs/fuse/inode.c +27
-3+if (sl) +fuse_cleanup_submount_lookup (fc, sl); }if (S_ISREG (inode->i_mode) && !fuse_is_bad (inode)) {WARN_ON (!list_empty (&fi->write_files));@@ -332,6 +374,14 @@ void fuse_change_attributes(struct inode *inode, struct fuse_attr *attr,fuse_dax_dontcache (inode, attr->flags); } +static void fuse_init_submount_lookup (struct fuse_submount_lookup *sl, +u64 nodeid) +{ + sl->nodeid = nodeid; + sl->nlookup =1 ; +refcount_set (&sl->count,1 ); +} +static void fuse_init_inode (struct inode *inode,struct fuse_attr *attr,struct fuse_conn *fc) {@@ -395,12 +445,22 @@ struct inode *fuse_iget(struct super_block *sb, u64 nodeid,*/ if (fc->auto_submounts && (attr->flags &FUSE_ATTR_SUBMOUNT ) &&S_ISDIR (attr->mode)) { +struct fuse_inode *fi; + inode =new_inode (sb);if (!inode)return NULL ;fuse_init_inode (inode, attr, fc); -get_fuse_inode (inode)->nodeid = nodeid; + fi =get_fuse_inode (inode); + fi->nodeid = nodeid; + fi->submount_lookup =fuse_alloc_submount_lookup (); +if (!fi->submount_lookup) { +iput (inode); +return NULL ; + } +/* Sets nlookup = 1 on fi->submount_lookup->nlookup */ +fuse_init_submount_lookup (fi->submount_lookup, nodeid); inode->i_flags |=S_AUTOMOUNT ; goto done; }@@ -423,11 +483,11 @@ struct inode *fuse_iget(struct super_block *sb, u64 nodeid,iput (inode); goto retry; } -done: fi =get_fuse_inode (inode);spin_lock (&fi->lock); fi->nlookup++;spin_unlock (&fi->lock); +done:fuse_change_attributes (inode, attr,NULL , attr_valid, attr_version);return inode;@@ -1465,6 +1525,8 @@ static int fuse_fill_super_submount(struct super_block *sb,struct super_block *parent_sb = parent_fi->inode.i_sb;struct fuse_attr root_attr;struct inode *root; +struct fuse_submount_lookup *sl; +struct fuse_inode *fi;fuse_sb_defaults (sb); fm->sb = sb;@@ -1487,12 +1549,32 @@ static int fuse_fill_super_submount(struct super_block *sb,* its nlookup should not be incremented. fuse_iget() does * that, though, so undo it here. */ -get_fuse_inode (root)->nlookup--; + fi =get_fuse_inode (root); + fi->nlookup--; + sb->s_d_op = &fuse_dentry_operations; sb->s_root =d_make_root (root);
fs/fuse/inode.c static int fuse_fill_super_submount(struct super_block *sb, · line 1566
Quoted 10 lines
fs/fuse/inode.c +7
-0if (!sb->s_root)return -ENOMEM ; +/* +* Grab the parent's submount_lookup pointer and take a +* reference on the shared nlookup from the parent. This is to +* prevent the last forget for this nodeid from getting +* triggered until all users have finished with it. +*/ +spin_lock (&parent_fi->lock);
Root has just been allocated, no locking needed.
fs/fuse/inode.c static int fuse_fill_super_submount(struct super_block *sb, · line 1568
Quoted 2 lines
fs/fuse/inode.c +2
-0+ sl = parent_fi->submount_lookup; +if (sl) {
WARN_ON(!sl);
Thanks,
Miklos
Re: [PATCH v3] fuse: share lookup state between submount and its parent
Hi Miklos,
Thanks for all the feedback. I've made all the changes you requested and was pleased to find that this reduced the overall size of the patch.
Quoted 51 lines · Miklos Szeredi
Quoted 35 lines · Krister Johansen
Fuse submounts do not perform a lookup for the nodeid that they inherit from their parent. Instead, the code decrements the nlookup on the submount's
fuse_inodewhen it is instantiated, and no forget is performed when a submount root is evicted.Trouble arises when the submount's parent is evicted despite the submount itself being in use. In this author's case, the submount was in a container and deatched from the initial mount namespace via a
MNT_DEATCHoperation. When memory pressure triggered the shrinker, the inode from the parent was evicted, which triggered enough forgets to render the submount's nodeid invalid.Since submounts should still function, even if their parent goes away, solve this problem by sharing refcounted state between the parent and its submount. When all of the references on this shared state reach zero, it's safe to forget the final lookup of the fuse nodeid.
Signed-off-by Krister Johansen <[email protected]>Fixes 1866d779d5d2 ("fuse: Allow fuse_fill_super_common() for submounts")--- fs/fuse/fuse_i.h | 20 +++++++++++ fs/fuse/inode.c | 88 ++++++++++++++++++++++++++++++++++++++++++++++-- 2 files changed, 105 insertions(+), 3 deletions(-)fs/fuse/fuse_i.h +1
-0@@ -63,6 +63,24 @@ struct fuse_forget_link {struct fuse_forget_link *next; }; +/* Submount lookup tracking */ fs/fuse/fuse_i.h struct fuse_forget_link { · line 76
Quoted 10 lines
fs/fuse/fuse_i.h +10
-0+struct fuse_submount_lookup { +/** Refcount */ +refcount_t count; + +/** Unique ID, which identifies the inode between userspace +* and kernel */ +u64 nodeid; + +/** Number of lookups on this inode */ +u64 nlookup;
sl->nlookupwill always be one. So that can just be implicit and this field can just go away.
Quoted 9 lines
fs/fuse/fuse_i.h struct fuse_forget_link { · line 81
Quoted 5 lines
fs/fuse/fuse_i.h +5
-0+ +/** The request used for sending the FORGET message */ +struct fuse_forget_link *forget; + +struct rcu_head rcu;RCU would be needed if any fields could be accessed from RCU protected code. But AFAICS there's no such access, so this shouldn't be needed.
Am I missing something?
No, you're correct and not missing anything. I've cleaned this up.
Thanks again,
-K
PATCH v4 1/1 fuse: share lookup state between submount and its parent
In reply to Miklos SzerediFuse submounts do not perform a lookup for the nodeid that they inherit from their parent. Instead, the code decrements the nlookup on the submount's fuse_inode when it is instantiated, and no forget is performed when a submount root is evicted.
Trouble arises when the submount's parent is evicted despite the submount itself being in use. In this author's case, the submount was in a container and deatched from the initial mount namespace via a MNT_DEATCH operation. When memory pressure triggered the shrinker, the inode from the parent was evicted, which triggered enough forgets to render the submount's nodeid invalid.
Since submounts should still function, even if their parent goes away, solve this problem by sharing refcounted state between the parent and its submount. When all of the references on this shared state reach zero, it's safe to forget the final lookup of the fuse nodeid.
---
Changes since v3:
- Remove rcu head from lookup tracking struct along with unnecessary kfree_rcu call. (Feedback from Miklos Szeredi)
- Make nlookup one implicitly. Remove from struct and simplify places where it was being used. (Feedback from Miklos Szeredi)
- Remove unnecessary spinlock acquisition. (Feedback from Miklos Szeredi)
- Add a WARN_ON if the lookup tracking cookie cannot be found during fuse_fill_super_submount. (Feedback from Miklos Szeredi)
Changes since v2:
- Move to an approach where the lookup is shared between the submount's parent and children. Use a reference counted lookup cookie to decide when it is safe to perform the forget of the final reference. (Feedback from Miklos Szeredi)
Changes since v1:
- Cleanups to pacify test robot
Changes since RFC:
- Modified fuse_fill_super_submount to always fail if dentry cannot be revalidated. (Feedback from Bernd Schubert)
- Fixed up an edge case where looked up but subsequently declared invalid dentries were not correctly tracking nlookup. (Error was introduced in my RFC).
--- fs/fuse/fuse_i.h | 15 ++++++++++ fs/fuse/inode.c | 74 ++++++++++++++++++++++++++++++++++++++++++++++-- 2 files changed, 86 insertions(+), 3 deletions(-)
fs/fuse/fuse_i.h +15 -0
@@ -63,6 +63,19 @@ struct fuse_forget_link {struct fuse_forget_link *next; }; +/* Submount lookup tracking */ +struct fuse_submount_lookup { +/** Refcount */ +refcount_t count; + +/** Unique ID, which identifies the inode between userspace +* and kernel */ +u64 nodeid; + +/** The request used for sending the FORGET message */ +struct fuse_forget_link *forget; +}; +/** FUSE inode */ struct fuse_inode {/** Inode data */
@@ -158,6 +171,8 @@ struct fuse_inode {*/ struct fuse_inode_dax *dax;#endif +/** Submount specific lookup tracking */ +struct fuse_submount_lookup *submount_lookup; };/** FUSE inode state bits */
fs/fuse/inode.c +71 -3
136 lines not on this page · raw message
Signature · 1 line
2.25.1
Quoted 7 lines · Krister Johansen
Hi,
I recently ran into a situation where a virtiofs client began encountering EBADF after the client / guest system had an OOM. After reproducing the issue and debugging, the problem is caused by a virtiofsd submount having the nodeid of its root dentry fogotten. This occurs because it borrows the reference for this dentry from the parent that is passed into the function.
Sorry, I didn't forget you, just didn't manage to review the 2nd version yet. Will definitely do this week.
Please also note that there will be merge conflicts with atomic open patches from Dharmendra/me. Although probably not too difficult to resolve.
Thanks,
Bernd
Quoted 12 lines · Bernd Schubert
Quoted 7 lines · Krister Johansen
Hi,
I recently ran into a situation where a virtiofs client began encountering EBADF after the client / guest system had an OOM. After reproducing the issue and debugging, the problem is caused by a virtiofsd submount having the nodeid of its root dentry fogotten. This occurs because it borrows the reference for this dentry from the parent that is passed into the function.
Quoted 2 lines
Sorry, I didn't forget you, just didn't manage to review the 2nd version yet. Will definitely do this week.
Thanks; I appreciate the feedback you've provided so far.
Quoted 2 lines
Please also note that there will be merge conflicts with atomic open patches from Dharmendra/me. Although probably not too difficult to resolve.
Sure. I'm happy to reparent, resolve those conflicts, re-test, and send another revision when we're ready. I suspect there are going to be additional changes requested on the v2. With that in mind, I'll hold off for the moment unless it is going to cause headaches for you.
For the atomic-open-revalidate changes: should I be working from what's on the list? This is the most recent patchset I see:
https://lore.kernel.org/linux-fsdevel/[email protected]/
I found a 6.5 relative tree of yours on GitHub by following the libfuse pull request, but nothing that seemed in sync with fuse/for-next.
Thanks,
-K
Quoted 18 lines · Krister Johansen
Quoted 12 lines · Bernd Schubert
Quoted 7 lines · Krister Johansen
Hi,
I recently ran into a situation where a virtiofs client began encountering EBADF after the client / guest system had an OOM. After reproducing the issue and debugging, the problem is caused by a virtiofsd submount having the nodeid of its root dentry fogotten. This occurs because it borrows the reference for this dentry from the parent that is passed into the function.Quoted 2 lines
Sorry, I didn't forget you, just didn't manage to review the 2nd version yet. Will definitely do this week.
Thanks; I appreciate the feedback you've provided so far.
Quoted 7 lines
Quoted 2 lines
Please also note that there will be merge conflicts with atomic open patches from Dharmendra/me. Although probably not too difficult to resolve.
Sure. I'm happy to reparent, resolve those conflicts, re-test, and send another revision when we're ready. I suspect there are going to be additional changes requested on the v2. With that in mind, I'll hold off for the moment unless it is going to cause headaches for you.
I certainly also didn't mean that you should check for merge conflicts, it was more an annotation that it might come up - depending on the merge order. Please don't stop to do improvements, resolving merge conflicts shouldn't be difficult. I'm going to add you to the atomic open patch series to keep you updated, if you don't mind.
Quoted 8 lines
For the atomic-open-revalidate changes: should I be working from what's on the list? This is the most recent patchset I see:
https://lore.kernel.org/linux-fsdevel/[email protected]/
I found a 6.5 relative tree of yours on GitHub by following the libfuse pull request, but nothing that seemed in sync with fuse/for-next.
I don't think there are conflicts with fuse-next right now, but I can check.
Thanks,
Bernd
Quoted 23 lines · Bernd Schubert
Quoted 12 lines · Krister Johansen
Quoted 11 lines · Bernd Schubert
Quoted 7 lines · Krister Johansen
Hi,
I recently ran into a situation where a virtiofs client began encountering EBADF after the client / guest system had an OOM. After reproducing the issue and debugging, the problem is caused by a virtiofsd submount having the nodeid of its root dentry fogotten. This occurs because it borrows the reference for this dentry from the parent that is passed into the function.Quoted 7 lines
Quoted 2 lines
Please also note that there will be merge conflicts with atomic open patches from Dharmendra/me. Although probably not too difficult to resolve.
Sure. I'm happy to reparent, resolve those conflicts, re-test, and send another revision when we're ready. I suspect there are going to be additional changes requested on the v2. With that in mind, I'll hold off for the moment unless it is going to cause headaches for you.
Quoted 6 lines
I certainly also didn't mean that you should check for merge conflicts, it was more an annotation that it might come up - depending on the merge order. Please don't stop to do improvements, resolving merge conflicts shouldn't be difficult.
I'm going to add you to the atomic open patch series to keep you updated, if you don't mind.
Thanks, no objections from me. I'm willing to help with any conflict resolution or retesting tasks, if anything turns out to be non-trivial. My goal is to get these patches to the state where they're acceptable. I'm happy to make additional changes, or work against a different branch.
-K