xen/arm: Hiding SMMUs from Dom0 when using ACPI on Xen
Hello,
There was few discussions recently about hiding SMMUs from DOM0 when using ACPI. I thought it would be good to have a separate thread for this.
When using ACPI, the SMMUs will be described in the IO Remapping Table (IORT). The specification can be found on the ARM website [1].
For a brief summary, the IORT can be used to discover the SMMUs present on the platform and find for a given device the ID to configure components such as ITS (DeviceID) and SMMU (StreamID).
The appendix A in the specification gives an example how DeviceID and StreamID can be found. For instance, when a PCI device is both protected by an SMMU and MSI-capable the following translation will happen:
RID -> StreamID -> DeviceID
Currently, SMMUs are hidden from DOM0 because they are been used by Xen and we don't support stage-1 SMMU. If we pass the IORT as it is, DOM0 will try to initialize SMMU and crash.
I first thought about using a Xen specific way (STAO) or extending a flag in IORT. But that is not ideal.
So we would have to rewrite the IORT for DOM0. Given that a range of RID can mapped to multiple ranges of DeviceID, we would have to translate RID one by one to find the associated DeviceID. I think this may end up to complex code and have a big IORT table.
However, given that DeviceID will be used by DOM0 to only configure the ITS. We have no need to use to have the DOM0 DeviceID equal to the host DeviceID. So I think we could simplify our life by generating DeviceID for each RID range.
Any opinions?
Cheers,
[1] http://infocenter.arm.com/help/topic/com.arm.doc.den0049b/DEN0049B_IO_Remapping_Table.pdf
Signature · 6 lines
Julien Grall _______________________________________________ Xen-devel mailing list [email protected] https://lists.xen.org/xen-devel
Hi Julien,
Quoted 21 lines · Julien Grall
Hello,
There was few discussions recently about hiding SMMUs from DOM0 when using ACPI. I thought it would be good to have a separate thread for this.
When using ACPI, the SMMUs will be described in the IO Remapping Table (IORT). The specification can be found on the ARM website [1].
For a brief summary, the IORT can be used to discover the SMMUs present on the platform and find for a given device the ID to configure components such as ITS (DeviceID) and SMMU (StreamID).
The appendix A in the specification gives an example how DeviceID and StreamID can be found. For instance, when a PCI device is both protected by an SMMU and MSI-capable the following translation will happen:
RID -> StreamID -> DeviceIDCurrently, SMMUs are hidden from DOM0 because they are been used by Xen and we don't support stage-1 SMMU. If we pass the IORT as it is, DOM0 will try to initialize SMMU and crash.
Quoted 7 lines
I first thought about using a Xen specific way (STAO) or extending a flag in IORT. But that is not ideal.
So we would have to rewrite the IORT for DOM0. Given that a range of RID can mapped to multiple ranges of DeviceID, we would have to translate RID one by one to find the associated DeviceID. I think this may end up to complex code and have a big IORT table.
Why can't we replace Output base of IORT of PCI node with SMMU output base?. I mean similar to PCI node without SMMU, why can't replace output base of PCI node with
SMMU's output base?.
The issue I see is RID is [15:0] where is DeviceID is [17:0].
Quoted 5 lines
However, given that DeviceID will be used by DOM0 to only configure the ITS. We have no need to use to have the DOM0 DeviceID equal to the host DeviceID. So I think we could simplify our life by generating DeviceID for each RID range.
If DOM0 DeviceID != host Device ID, then we cannot initialize ITS using DOM0 ITS commands (MAPD). So, is it concluded that ITS initializes all the devices with platform specific Device ID's in Xen?.
Quoted 8 lines
Any opinions?
Cheers,
[1]
http://infocenter.arm.com/help/topic/com.arm.doc.den0049b/DEN0049B_IO_Remapping_Table.pdf
Quoted 7 lines
--
Julien Grall_______________________________________________
Xen-devel mailing list
[email protected]
https://lists.xen.org/xen-devel
_______________________________________________
Xen-devel mailing list
[email protected]
https://lists.xen.org/xen-devel
Quoted 1 line · Vijay Kilari
Hi Julien,
Hello Vijay,
Quoted 30 lines · Julien Grall
Quoted 21 lines
Hello,
There was few discussions recently about hiding SMMUs from DOM0 when using ACPI. I thought it would be good to have a separate thread for this.
When using ACPI, the SMMUs will be described in the IO Remapping Table (IORT). The specification can be found on the ARM website [1].
For a brief summary, the IORT can be used to discover the SMMUs present on the platform and find for a given device the ID to configure components such as ITS (DeviceID) and SMMU (StreamID).
The appendix A in the specification gives an example how DeviceID and StreamID can be found. For instance, when a PCI device is both protected by an SMMU and MSI-capable the following translation will happen:
RID -> StreamID -> DeviceIDCurrently, SMMUs are hidden from DOM0 because they are been used by Xen and we don't support stage-1 SMMU. If we pass the IORT as it is, DOM0 will try to initialize SMMU and crash.
Quoted 7 lines
I first thought about using a Xen specific way (STAO) or extending a flag in IORT. But that is not ideal.
So we would have to rewrite the IORT for DOM0. Given that a range of RID can mapped to multiple ranges of DeviceID, we would have to translate RID one by one to find the associated DeviceID. I think this may end up to complex code and have a big IORT table.
Quoted 4 lines
Why can't we replace Output base of IORT of PCI node with SMMU output base?. I mean similar to PCI node without SMMU, why can't replace output base of PCI node with
SMMU's output base?.
Because I don't see anything in the spec preventing one RC ID mapping to produce multiple SMMU ID mapping. So which output base would you use?
Quoted 4 lines
The issue I see is RID is [15:0] where is DeviceID is [17:0].
Quoted 1 line
Quoted 8 lines
Quoted 4 lines
However, given that DeviceID will be used by DOM0 to only configure the ITS. We have no need to use to have the DOM0 DeviceID equal to the host DeviceID. So I think we could simplify our life by generating DeviceID for each RID range.
If DOM0 DeviceID != host Device ID, then we cannot initialize ITS using DOM0 ITS commands (MAPD). So, is it concluded that ITS initializes all the devices with platform specific Device ID's in Xen?.
Initializing ITS using DOM0 ITS command is a workaround until we get PCI passthrough done. It would still be possible to implement that with vDeviceID != pDeviceID as Xen would likely have the mapping between the 2 DeviceID.
Cheers,
Signature · 6 lines
Julien Grall _______________________________________________ Xen-devel mailing list [email protected] https://lists.xen.org/xen-devel
Hi Julien,
Quoted 37 lines · Julien Grall
Quoted 1 line · Vijay Kilari
Hi Julien,
Hello Vijay,
Quoted 30 lines · Julien Grall
Quoted 28 lines
Hello,
There was few discussions recently about hiding SMMUs from DOM0 when using ACPI. I thought it would be good to have a separate thread for this.
When using ACPI, the SMMUs will be described in the IO Remapping Table (IORT). The specification can be found on the ARM website [1].
For a brief summary, the IORT can be used to discover the SMMUs present on the platform and find for a given device the ID to configure components such as ITS (DeviceID) and SMMU (StreamID).
The appendix A in the specification gives an example how DeviceID and StreamID can be found. For instance, when a PCI device is both protected by an SMMU and MSI-capable the following translation will happen:
RID -> StreamID -> DeviceIDCurrently, SMMUs are hidden from DOM0 because they are been used by Xen and we don't support stage-1 SMMU. If we pass the IORT as it is, DOM0 will try to initialize SMMU and crash.
I first thought about using a Xen specific way (STAO) or extending a flag in IORT. But that is not ideal.
So we would have to rewrite the IORT for DOM0. Given that a range of RID can mapped to multiple ranges of DeviceID, we would have to translate RID one by one to find the associated DeviceID. I think this may end up to complex code and have a big IORT table.
Quoted 7 lines
Quoted 4 lines
Why can't we replace Output base of IORT of PCI node with SMMU output base?. I mean similar to PCI node without SMMU, why can't replace output base of PCI node with
SMMU's output base?.Because I don't see anything in the spec preventing one RC ID mapping to produce multiple SMMU ID mapping. So which output base would you use?
Basically, remove SMMU nodes, and replaces output of the PCIe and named nodes ID mappings with ITS nodes.
RID --> StreamID --> dviceID --> ITS device id = RID --> dviceID --> ITS device id
Quoted 3 lines
Quoted 3 lines
The issue I see is RID is [15:0] where is DeviceID is [17:0].
Actuality device id is 32bit field.
Quoted 6 lines
Quoted 6 lines
Quoted 5 lines
However, given that DeviceID will be used by DOM0 to only configure the ITS. We have no need to use to have the DOM0 DeviceID equal to the host DeviceID. So I think we could simplify our life by generating DeviceID for each RID range.
Quoted 6 lines
Quoted 3 lines
If DOM0 DeviceID != host Device ID, then we cannot initialize ITS using DOM0 ITS commands (MAPD). So, is it concluded that ITS initializes all the devices with platform specific Device ID's in Xen?.
Initializing ITS using DOM0 ITS command is a workaround until we get PCI passthrough done. It would still be possible to implement that with vDeviceID != pDeviceID as Xen would likely have the mapping between the 2 DeviceID.
I believe mapping dom0 ITS commands to XEN ITS commands one to one is the better approach. Physical DeviceID is unique per ITS group, not a system wide unique ID. In case of direct VLPI, LPI number has to be programmed whenever dom0/domU calls the MAPTI command but not at the time of PCIe device creation.
Signature · 9 lines
Shanker Donthineni Qualcomm Datacenter Technologies, Inc. as an affiliate of Qualcomm Technologies, Inc. Qualcomm Technologies, Inc. is a member of the Code Aurora Forum, a Linux Foundation Collaborative Project. _______________________________________________ Xen-devel mailing list [email protected] https://lists.xen.org/xen-devel
Quoted 1 line · Shanker Donthineni
Hi Julien,
Hi Shanker,
Please don't drop people in CC. In my case, any e-mail I am not CCed are skipping my inbox and I may not read them for a while.
Quoted 60 lines · Julien Grall
Quoted 48 lines · Vijay Kilari
Quoted 1 line
Hi Julien,
Hello Vijay,
Quoted 41 lines
Quoted 38 lines · Julien Grall
Hello,
There was few discussions recently about hiding SMMUs from DOM0 when using
ACPI. I thought it would be good to have a separate thread for this.When using ACPI, the SMMUs will be described in the IO Remapping Table (IORT). The specification can be found on the ARM website [1].
For a brief summary, the IORT can be used to discover the SMMUs present on
the platform and find for a given device the ID to configure components such
as ITS (DeviceID) and SMMU (StreamID).The appendix A in the specification gives an example how DeviceID and StreamID can be found. For instance, when a PCI device is both protected by
an SMMU and MSI-capable the following translation will happen:RID -> StreamID -> DeviceIDCurrently, SMMUs are hidden from DOM0 because they are been used by Xen and
we don't support stage-1 SMMU. If we pass the IORT as it is, DOM0 will try
to initialize SMMU and crash.I first thought about using a Xen specific way (STAO) or extending a flag in
IORT. But that is not ideal.So we would have to rewrite the IORT for DOM0. Given that a range of RID can
mapped to multiple ranges of DeviceID, we would have to translate RID one by
one to find the associated DeviceID. I think this may end up to complex code
and have a big IORT table.Quoted 9 lines
Quoted 5 lines
Why can't we replace Output base of IORT of PCI node with SMMU output base?.
I mean similar to PCI node without SMMU, why can't replace output base of PCI node with
SMMU's output base?.Because I don't see anything in the spec preventing one RC ID mapping to produce multiple SMMU ID mapping. So which output base would you use?
Quoted 5 lines
Basically, remove SMMU nodes, and replaces output of the PCIe and named nodes ID mappings with ITS nodes.
RID --> StreamID --> dviceID --> ITS device id = RID --> dviceID --> ITS device id
Can you detail it? You seem to assume that one RC ID mapping range will only produce ID mapping range. AFAICT, this is not mandated by the spec.
Quoted 27 lines
Quoted 4 lines
Quoted 4 lines
The issue I see is RID is [15:0] where is DeviceID is [17:0].
Actuality device id is 32bit field.
Quoted 15 lines
Quoted 9 lines
Quoted 8 lines
However, given that DeviceID will be used by DOM0 to only configure the ITS.
We have no need to use to have the DOM0 DeviceID equal to the host DeviceID.
So I think we could simplify our life by generating DeviceID for each RID
range.Quoted 5 lines
If DOM0 DeviceID != host Device ID, then we cannot initialize ITS using DOM0
ITS commands (MAPD). So, is it concluded that ITS initializes all the devices
with platform specific Device ID's in Xen?.Quoted 5 lines
Initializing ITS using DOM0 ITS command is a workaround until we get PCI passthrough done. It would still be possible to implement that with vDeviceID != pDeviceID as Xen would likely have the mapping between the 2 DeviceID.
Quoted 3 lines
I believe mapping dom0 ITS commands to XEN ITS commands one to one is the better approach. Physical DeviceID is unique per ITS group, not a system wide unique ID.
As for guest, you don't care about the virtual DeviceID for DOM0 as long as you are able to map it to the host ITS and host DeviceID.
Quoted 3 lines
In case of direct VLPI, LPI number has to be
programmed whenever dom0/domU calls the MAPTI command but not at the time of PCIe device creation.
I am a bit confused. Why are you speaking about direct vLPI here? This has no relation with the IORT.
Cheers,
Signature · 6 lines
Julien Grall _______________________________________________ Xen-devel mailing list [email protected] https://lists.xen.org/xen-devel
+Chales.
Hi Julien,
Quoted 67 lines · Julien Grall
Quoted 1 line · Shanker Donthineni
Hi Julien,
Hi Shanker,
Please don't drop people in CC. In my case, any e-mail I am not CCed are skipping my inbox and I may not read them for a while.
Quoted 60 lines · Julien Grall
Quoted 57 lines · Vijay Kilari
Quoted 1 line
Hi Julien,
Hello Vijay,
Quoted 41 lines
Quoted 31 lines · Julien Grall
Hello,
There was few discussions recently about hiding SMMUs from DOM0 when using
ACPI. I thought it would be good to have a separate thread for this.When using ACPI, the SMMUs will be described in the IO Remapping Table (IORT). The specification can be found on the ARM website [1].
For a brief summary, the IORT can be used to discover the SMMUs present on
the platform and find for a given device the ID to configure components such
as ITS (DeviceID) and SMMU (StreamID).The appendix A in the specification gives an example how DeviceID and StreamID can be found. For instance, when a PCI device is both protected by
an SMMU and MSI-capable the following translation will happen:RID -> StreamID -> DeviceIDCurrently, SMMUs are hidden from DOM0 because they are been used by Xen and
we don't support stage-1 SMMU. If we pass the IORT as it is, DOM0 will try
to initialize SMMU and crash.I first thought about using a Xen specific way (STAO) or extending a flag in
IORT. But that is not ideal.Quoted 7 lines
So we would have to rewrite the IORT for DOM0. Given that a range of RID can
mapped to multiple ranges of DeviceID, we would have to translate RID one by
one to find the associated DeviceID. I think this may end up to complex code
and have a big IORT table.Quoted 5 lines
Why can't we replace Output base of IORT of PCI node with SMMU output base?.
I mean similar to PCI node without SMMU, why can't replace output base of PCI node with
SMMU's output base?.Because I don't see anything in the spec preventing one RC ID mapping to produce multiple SMMU ID mapping. So which output base would you use?
Quoted 8 lines
Quoted 5 lines
Basically, remove SMMU nodes, and replaces output of the PCIe and named nodes ID mappings with ITS nodes.
RID --> StreamID --> dviceID --> ITS device id = RID --> dviceID --> ITS device id
Can you detail it? You seem to assume that one RC ID mapping range will only produce ID mapping range. AFAICT, this is not mandated by the spec.
You are correct that it is not mandated by the spec, but AFAIK there seems to be no valid use case for that.
RID range should not overlap between ID Array entries. I believe this would be updated in the next IORT spec revision.
I have started working on recreating iort for dom0 with this restriction.
Quoted 33 lines
Quoted 27 lines
Quoted 4 lines
Quoted 4 lines
The issue I see is RID is [15:0] where is DeviceID is [17:0].
Actuality device id is 32bit field.
Quoted 15 lines
Quoted 9 lines
Quoted 8 lines
However, given that DeviceID will be used by DOM0 to only configure the ITS.
We have no need to use to have the DOM0 DeviceID equal to the host DeviceID.
So I think we could simplify our life by generating DeviceID for each RID
range.Quoted 5 lines
If DOM0 DeviceID != host Device ID, then we cannot initialize ITS using DOM0
ITS commands (MAPD). So, is it concluded that ITS initializes all the devices
with platform specific Device ID's in Xen?.Quoted 5 lines
Initializing ITS using DOM0 ITS command is a workaround until we get PCI passthrough done. It would still be possible to implement that with vDeviceID != pDeviceID as Xen would likely have the mapping between the 2 DeviceID.
Quoted 3 lines
I believe mapping dom0 ITS commands to XEN ITS commands one to one is the better approach. Physical DeviceID is unique per ITS group, not a system wide unique ID.
As for guest, you don't care about the virtual DeviceID for DOM0 as long as you are able to map it to the host ITS and host DeviceID.
Quoted 8 lines
Quoted 3 lines
In case of direct VLPI, LPI number has to be
programmed whenever dom0/domU calls the MAPTI command but not at the time of PCIe device creation.I am a bit confused. Why are you speaking about direct vLPI here? This has no relation with the IORT.
Cheers,
_______________________________________________
Xen-devel mailing list
[email protected]
https://lists.xen.org/xen-devel
Hello,
Quoted 77 lines · Manish Jaggi
Quoted 76 lines · Julien Grall
Quoted 1 line · Shanker Donthineni
Hi Julien,
Hi Shanker,
Please don't drop people in CC. In my case, any e-mail I am not CCed are skipping my inbox and I may not read them for a while.
Quoted 67 lines · Julien Grall
Quoted 55 lines · Vijay Kilari
Quoted 1 line
Hi Julien,
Hello Vijay,
Quoted 42 lines
Quoted 32 lines · Julien Grall
Hello,
There was few discussions recently about hiding SMMUs from DOM0 when using
ACPI. I thought it would be good to have a separate thread for this.When using ACPI, the SMMUs will be described in the IO Remapping Table
(IORT). The specification can be found on the ARM website [1].For a brief summary, the IORT can be used to discover the SMMUs present on
the platform and find for a given device the ID to configure components such
as ITS (DeviceID) and SMMU (StreamID).The appendix A in the specification gives an example how DeviceID and StreamID can be found. For instance, when a PCI device is both protected by
an SMMU and MSI-capable the following translation will happen:RID -> StreamID -> DeviceIDCurrently, SMMUs are hidden from DOM0 because they are been used by Xen and
we don't support stage-1 SMMU. If we pass the IORT as it is, DOM0 will try
to initialize SMMU and crash.I first thought about using a Xen specific way (STAO) or extending a flag in
IORT. But that is not ideal.Quoted 7 lines
So we would have to rewrite the IORT for DOM0. Given that a range of RID can
mapped to multiple ranges of DeviceID, we would have to translate RID one by
one to find the associated DeviceID. I think this may end up to complex code
and have a big IORT table.Quoted 5 lines
Why can't we replace Output base of IORT of PCI node with SMMU output base?.
I mean similar to PCI node without SMMU, why can't replace output base of PCI node with
SMMU's output base?.Quoted 4 lines
Because I don't see anything in the spec preventing one RC ID mapping to produce multiple SMMU ID mapping. So which output base would you use?
Basically, remove SMMU nodes, and replaces output of the PCIe and named nodes ID mappings with ITS nodes.
RID --> StreamID --> dviceID --> ITS device id = RID --> dviceID --> ITS device id
Quoted 6 lines
Quoted 4 lines
Can you detail it? You seem to assume that one RC ID mapping range will only produce ID mapping range. AFAICT, this is not mandated by the spec.
You are correct that it is not mandated by the spec, but AFAIK there seems to be no valid use case for that.
Xen has to be compliant with the spec, if the spec says something then we should do it unless there is a strong reason not to.
In this case, it is not too difficult to implement the suggestion I wrote a couple of months ago. So why would we try to put us in a corner?
Quoted 2 lines
RID range should not overlap between ID Array entries.
I believe you misunderstood my point here. So let me give an example. My understanding of the spec is it is possible to have:
RC A
// doesn't use SMMU 0 so just outputs DeviceIDs to ITS GROUP 0 // Input ID --> Output reference: Output ID
0x0000-0xffff --> ITS GROUP 0 : 0x0000->0xffff
SMMU 0
// Note that range of StreamIDs that map to DeviceIDs excludes // the NIC 0 DeviceID as it does not generate MSIs
// Input ID --> Output reference: Output ID
0x0000-0x01ff --> ITS GROUP 0 : 0x10000->0x101ff 0x0200-0xffff --> ITS GROUP 0 : 0x20000->0x207ff
// SMMU 0 Control interrupt is MSI based
// Input ID --> Output reference: Output ID
N/A --> ITS GROUP 0 : 0x200001
Quoted 1 line
I believe this would be updated in the next IORT spec revision.
Well, Xen should still support current revision of IORT even if the next version add more restriction.
Cheers,
Signature · 6 lines
Julien Grall _______________________________________________ Xen-devel mailing list [email protected] https://lists.xen.org/xen-devel
Hi Julien,
Quoted 58 lines · Julien Grall
Hello,
Quoted 55 lines · Manish Jaggi
Quoted 54 lines · Julien Grall
Quoted 1 line · Shanker Donthineni
Hi Julien,
Hi Shanker,
Please don't drop people in CC. In my case, any e-mail I am not CCed are skipping my inbox and I may not read them for a while.
Quoted 46 lines · Julien Grall
Quoted 44 lines · Vijay Kilari
Quoted 1 line
Hi Julien,
Hello Vijay,
Quoted 37 lines
Quoted 35 lines · Julien Grall
Hello,
There was few discussions recently about hiding SMMUs from DOM0 when using
ACPI. I thought it would be good to have a separate thread for this.When using ACPI, the SMMUs will be described in the IO Remapping Table
(IORT). The specification can be found on the ARM website [1].For a brief summary, the IORT can be used to discover the SMMUs present on
the platform and find for a given device the ID to configure components such
as ITS (DeviceID) and SMMU (StreamID).The appendix A in the specification gives an example how DeviceID and StreamID can be found. For instance, when a PCI device is both protected by
an SMMU and MSI-capable the following translation will happen:RID -> StreamID -> DeviceIDCurrently, SMMUs are hidden from DOM0 because they are been used by Xen and
we don't support stage-1 SMMU. If we pass the IORT as it is, DOM0 will try
to initialize SMMU and crash.I first thought about using a Xen specific way (STAO) or extending a flag in
IORT. But that is not ideal.So we would have to rewrite the IORT for DOM0. Given that a range of RID can
mapped to multiple ranges of DeviceID,
Do you envisage a scenario where same RID can map to multiple StreamIDs belonging to different SMMUs ?
Quoted 28 lines
Quoted 28 lines
Quoted 28 lines
Quoted 17 lines
Quoted 12 lines
Quoted 11 lines
Quoted 5 lines
we would have to translate
RID one by
one to find the associated DeviceID. I think this may end up to complex code
and have a big IORT table.Why can't we replace Output base of IORT of PCI node with SMMU output base?.
I mean similar to PCI node without SMMU, why can't replace output base of PCI node with
SMMU's output base?.Quoted 4 lines
Because I don't see anything in the spec preventing one RC ID mapping to produce multiple SMMU ID mapping. So which output base would you use?
Quoted 6 lines
Basically, remove SMMU nodes, and replaces output of the PCIe and named nodes ID mappings with ITS nodes.
RID --> StreamID --> dviceID --> ITS device id = RID --> dviceID -->
ITS device idCan you detail it? You seem to assume that one RC ID mapping range will only produce ID mapping range. AFAICT, this is not mandated by the spec.
Quoted 7 lines
Quoted 2 lines
You are correct that it is not mandated by the spec, but AFAIK there seems to be no valid use case for that.
Xen has to be compliant with the spec, if the spec says something then we should do it unless there is a strong reason not to.
In this case, it is not too difficult to implement the suggestion I wrote a couple of months ago. So why would we try to put us in a corner?
See below
Quoted 17 lines
Quoted 2 lines
RID range should not overlap between ID Array entries.
I believe you misunderstood my point here. So let me give an example. My understanding of the spec is it is possible to have:
RC A
// doesn't use SMMU 0 so just outputs DeviceIDs to ITS GROUP 0 // Input ID --> Output reference: Output ID
0x0000-0xffff --> ITS GROUP 0 : 0x0000->0xffffSMMU 0
// Note that range of StreamIDs that map to DeviceIDs excludes // the NIC 0 DeviceID as it does not generate MSIs
// Input ID --> Output reference: Output ID
0x0000-0x01ff --> ITS GROUP 0 : 0x10000->0x101ff 0x0200-0xffff --> ITS GROUP 0 : 0x20000->0x207ff
Quoted 4 lines
// SMMU 0 Control interrupt is MSI based
// Input ID --> Output reference: Output ID
N/A --> ITS GROUP 0 :0x200001
I could have misunderstood so I am stating my understanding so far .. please feel free to correct me :)
In the IORT table using the PCI-RC node, SMMU node and ITS node, RID->StreamID->Device-ID mapping can be generated.
As per IORT spec toady, same RID can be mapped to different StreamIDs using two ID Array elements with same RID range but different output reference. There exists no use case for such a scenario hence a clarification is required in IORT spec which states that RID range cannot overlap in the ID array.
with this clarification in place, it is straight-forward to map RID to a device-ID by replacing output of SMMU to output of RCI-RC
Quoted 6 lines
Quoted 1 line
I believe this would be updated in the next IORT spec revision.
Well, Xen should still support current revision of IORT even if the next version add more restriction.
Cheers,
-Manish
_______________________________________________
Xen-devel mailing list
[email protected]
https://lists.xen.org/xen-devel
Quoted 8 lines · Manish Jaggi
In the IORT table using the PCI-RC node, SMMU node and ITS node, RID->StreamID->Device-ID mapping can be generated.
As per IORT spec toady, same RID can be mapped to different StreamIDs using two ID Array elements with same RID range but different output reference.
There exists no use case for such a scenario hence a clarification is required in IORT spec which states that RID range cannot overlap in the ID array.
I understand that.
Quoted 3 lines
with this clarification in place, it is straight-forward to map RID to a device-ID by replacing output of SMMU to output of RCI-RC
I am not sure to follow your suggestion here. But I will wait a patch before commenting.
Cheers,
Signature · 6 lines
Julien Grall _______________________________________________ Xen-devel mailing list [email protected] https://lists.xen.org/xen-devel
Quoted 12 lines · Julien Grall
Quoted 8 lines · Manish Jaggi
In the IORT table using the PCI-RC node, SMMU node and ITS node, RID->StreamID->Device-ID mapping can be generated.
As per IORT spec toady, same RID can be mapped to different StreamIDs using two ID Array elements with same RID range but different output reference.
There exists no use case for such a scenario hence a clarification is required in IORT spec which states that RID range cannot overlap in the ID array.
Quoted 8 lines
I understand that.
Quoted 3 lines
with this clarification in place, it is straight-forward to map RID to a device-ID by replacing output of SMMU to output of RCI-RC
I am not sure to follow your suggestion here. But I will wait a patch before commenting.
Please see [RFC] [PATCH] arm-acpi: Hide SMMU from IORT for hardware domain
Quoted 2 lines
Cheers,
_______________________________________________
Xen-devel mailing list
[email protected]
https://lists.xen.org/xen-devel