some bugfixes for hns3 PMD
cover some bugfixes for hns3 PMD
This set of patches are bugfixes for hns3 PMD.
Chengchang Tang (1):
net/hns3: fix lack of rollback after setting PVID failed
Chengwen Feng (4):
net/hns3: fix set default MAC addr fail in bonding of VF net/hns3: fix flow counter not cleared when create net/hns3: fix VF mailbox head field wrong update net/hns3: support get device version when dump register
Hongbo Zheng (3):
net/hns3: fix the FLR miss detection
net/hns3: delete redundant blank line
net/hns3: fix code style static warning
Huisong Li (2):
net/hns3: fix some function names for copper media type net/hns3: fix flow control exception
drivers/net/hns3/hns3_cmd.c | 8 +++--- drivers/net/hns3/hns3_ethdev.c | 37 +++++++++++++++++++++------- drivers/net/hns3/hns3_ethdev.h | 1 - drivers/net/hns3/hns3_ethdev_vf.c | 4 --- drivers/net/hns3/hns3_flow.c | 10 ++++++++ drivers/net/hns3/hns3_mbx.c | 52 +++++++++++---------------------------- drivers/net/hns3/hns3_regs.c | 2 ++ drivers/net/hns3/hns3_rxtx.c | 2 +- 8 files changed, 61 insertions(+), 55 deletions(-)
Signature · 1 line
2.7.4
PATCH 1/10 net/hns3: fix some function names for copper media type
From: Huisong Li <[email protected]>
PHY is a common concept for the copper and optical media type interface. There are some inappropriate function names for copper ports, which needs to be adjusted.
--- drivers/net/hns3/hns3_ethdev.c | 12 ++++++------ 1 file changed, 6 insertions(+), 6 deletions(-)
drivers/net/hns3/hns3_ethdev.c +6 -6
@@ -4547,7 +4547,7 @@ hns3_update_fiber_link_info(struct hns3_hw *hw) }static void -hns3_parse_phy_params (struct hns3_cmd_desc *desc,struct hns3_mac *mac) +hns3_parse_copper_phy_params (struct hns3_cmd_desc *desc,struct hns3_mac *mac) {struct hns3_phy_params_bd0_cmd *req;
@@ -4565,7 +4565,7 @@ hns3_parse_phy_params(struct hns3_cmd_desc *desc, struct hns3_mac *mac) }static int -hns3_get_phy_params (struct hns3_hw *hw,struct hns3_mac *mac) +hns3_get_copper_phy_params (struct hns3_hw *hw,struct hns3_mac *mac) {struct hns3_cmd_desc desc[HNS3_PHY_PARAM_CFG_BD_NUM ];uint16_t i;
@@ -4584,20 +4584,20 @@ hns3_get_phy_params(struct hns3_hw *hw, struct hns3_mac *mac)return ret; } -hns3_parse_phy_params (desc, mac); +hns3_parse_copper_phy_params (desc, mac);return 0 ; }static int -hns3_update_phy_link_info (struct hns3_hw *hw) +hns3_update_copper_link_info (struct hns3_hw *hw) {struct hns3_mac *mac = &hw->mac;struct hns3_mac mac_info;int ret;memset (&mac_info,0 ,sizeof (struct hns3_mac )); - ret =hns3_get_phy_params (hw, &mac_info); + ret =hns3_get_copper_phy_params (hw, &mac_info);if (ret)return ret;
@@ -4626,7 +4626,7 @@ hns3_update_link_info(struct rte_eth_dev *eth_dev)int ret =0 ;if (hw->mac.media_type ==HNS3_MEDIA_TYPE_COPPER ) - ret =hns3_update_phy_link_info (hw); + ret =hns3_update_copper_link_info (hw);else if (hw->mac.media_type ==HNS3_MEDIA_TYPE_FIBER ) ret =hns3_update_fiber_link_info (hw);
Signature · 1 line
2.7.4
PATCH 2/10 net/hns3: fix set default MAC addr fail in bonding of VF
In reply to Min Hu (Connor)From: Chengwen Feng <[email protected]>
When start testpmd with two hns3 VFs(0000:bd:01.0, 0000:bd:01.7), and then execute the following commands:
testpmd> create bonded device 1 0
testpmd> set bonding mac_addr 2 3c:12:34:56:78:9a testpmd> add bonding slave 0 2
testpmd> add bonding slave 1 2
testpmd> set portmask 0x4
testpmd> port start 2
It will occurs the following error in a low probability:
0000:bd:01.0 hns3_get_mbx_resp(): VF could not get mbx(3,0) head(16) tail(15) lost(1) from PF in_irq:0 0000:bd:01.0 hns3vf_set_default_mac_addr(): Failed to set mac addr(3C:**:**:**:78:9A) for vf: -62 mac_address_slaves_update(1541) - Failed to update port Id 0 MAC address
The problem replay:
1. the 'port start 2' command will start slave ports and then set slave mac address, the function call flow: bond_ethdev_start -> mac_address_slaves_update.
2. there are also a monitor task which running in intr thread will check slave ports link status and update slave ports mac address, the function call flow: bond_ethdev_slave_link_status_change_monitor -> bond_ethdev_lsc_event_callback -> mac_address_slaves_update.
3. because the above step1&2 running on different threads, they may both call drivers ops mac_addr_set which is hns3vf_set_default_mac_addr.
4. hns3vf_set_default_mac_addr will first acquire hw.lock and then send mailbox to PF and wait PF's response message.
Note: the PF's response is an independent message which will received in hw.cmq.crq, the receiving operation can only performed in intr thread.
5. so if the step1 operation hold the hw.lock and try get response message, and step2 operation try acquire the hw.lock and so it can't process the response message, this will lead to step1 fail.
The solution:
1. make all threads could process the mailbox response message, which protected by the hw.cmq.crq.lock.
2. use the following rules to avoid deadlock:
2.1. ensure use the correct locking sequence: hw.lock > hw.mbx_resp.lock > hw.cmq.crq.lock.
2.2. make sure don't acquire such as hw.lock & hw.mbx_resp.lock again when process mailbox response message.
--- drivers/net/hns3/hns3_ethdev.h | 1 - drivers/net/hns3/hns3_ethdev_vf.c | 3 --- drivers/net/hns3/hns3_mbx.c | 51 +++++++++++---------------------------- 3 files changed, 14 insertions(+), 41 deletions(-)
drivers/net/hns3/hns3_ethdev.h +0 -1
@@ -439,7 +439,6 @@ struct hns3_hw {struct hns3_cmq cmq;struct hns3_mbx_resp_status mbx_resp;/* mailbox response */ struct hns3_mbx_arq_ring arq;/* mailbox async rx queue */ -pthread_t irq_thread_id;struct hns3_mac mac;unsigned int secondary_cnt;/* Number of secondary processes init'd. */ struct hns3_tqp_stats tqp_stats;
drivers/net/hns3/hns3_ethdev_vf.c +0 -3
@@ -1109,9 +1109,6 @@ hns3vf_interrupt_handler(void *param)enum hns3vf_evt_cause event_cause;uint32_t clearval; -if (hw->irq_thread_id ==0 ) - hw->irq_thread_id =pthread_self (); -/* Disable interrupt */ hns3vf_disable_irq0 (hw);
drivers/net/hns3/hns3_mbx.c +14 -37
89 lines not on this page · raw message
Signature · 1 line
2.7.4
PATCH 3/10 net/hns3: fix the FLR miss detection
In reply to Min Hu (Connor)From: Hongbo Zheng <[email protected]>
When FLR occurs, the head pointer register of the command queue will be cleared, resulting in abnormal detection of the head pointer register of the command queue. At present, FLR is detected in this way, and the reset recovery process is executed.
However, when FLR occurs, the header pointer register of the command queue is not necessarily abnormal. For example, when the driver runs normally, the value of the header pointer register of the command queue may also be 0, which will lead to the miss detection of FLR.
Therefore, the judgment that whether the base address register of command queue is 0 is added to ensure that FLR not miss detection.
--- drivers/net/hns3/hns3_cmd.c | 8 +++++--- 1 file changed, 5 insertions(+), 3 deletions(-)
drivers/net/hns3/hns3_cmd.c +5 -3
@@ -195,12 +195,14 @@ hns3_cmd_csq_clean(struct hns3_hw *hw) {struct hns3_cmq_ring *csq = &hw->cmq.csq;uint32_t head; +uint32_t addr;int clean; head =hns3_read_dev (hw,HNS3_CMDQ_TX_HEAD_REG ); -if (!is_valid_csq_clean_head (csq, head)) { -hns3_err (hw,"wrong cmd head (%u, %u-%u)" , head, - csq->next_to_use, csq->next_to_clean); + addr =hns3_read_dev (hw,HNS3_CMDQ_TX_ADDR_L_REG ); +if (!is_valid_csq_clean_head (csq, head) || addr ==0 ) { +hns3_err (hw,"wrong cmd addr(%0x) head (%u, %u-%u)" , addr, head, + csq->next_to_use, csq->next_to_clean);if (rte_eal_process_type () ==RTE_PROC_PRIMARY ) {__atomic_store_n (&hw->reset.disable_cmd,1 , __ATOMIC_RELAXED);
Signature · 1 line
2.7.4
PATCH 4/10 net/hns3: fix lack of rollback after setting PVID failed
In reply to Min Hu (Connor)From: Chengchang Tang <[email protected]>
Currently, three hardware operations are involved in setting the PVID. If any operation fails, a failure will be returned. And there may be residual hardware configurations because no rollback is performed.
This patch adds rollback operation for setting PVID to avoid residual hardware configuration after the PVID fails to be configured.
--- drivers/net/hns3/hns3_ethdev.c | 20 +++++++++++++++++--- 1 file changed, 17 insertions(+), 3 deletions(-)
drivers/net/hns3/hns3_ethdev.c +17 -3
@@ -964,7 +964,7 @@ hns3_vlan_pvid_configure(struct hns3_adapter *hns, uint16_t pvid, int on) {struct hns3_hw *hw = &hns->hw;uint16_t port_base_vlan_state; -int ret; +int ret, err;if (on ==0 && pvid != hw->port_base_vlan_cfg.pvid) {if (hw->port_base_vlan_cfg.pvid !=HNS3_INVALID_PVID )
@@ -987,7 +987,7 @@ hns3_vlan_pvid_configure(struct hns3_adapter *hns, uint16_t pvid, int on)if (ret) {hns3_err (hw,"failed to config rx vlan strip for pvid, " "ret = %d" , ret); -return ret; + goto pvid_vlan_strip_fail; }if (pvid ==HNS3_INVALID_PVID )
@@ -996,13 +996,27 @@ hns3_vlan_pvid_configure(struct hns3_adapter *hns, uint16_t pvid, int on)if (ret) {hns3_err (hw,"failed to update vlan filter entries, ret = %d" , ret); -return ret; + goto vlan_filter_set_fail; } out: hw->port_base_vlan_cfg.state = port_base_vlan_state; hw->port_base_vlan_cfg.pvid = on ? pvid :HNS3_INVALID_PVID ;return ret; + +vlan_filter_set_fail: + err =hns3_en_pvid_strip (hns, hw->port_base_vlan_cfg.state == +HNS3_PORT_BASE_VLAN_ENABLE ); +if (err) +hns3_err (hw,"fail to rollback pvid strip, ret = %d" , err); + +pvid_vlan_strip_fail: + err =hns3_vlan_txvlan_cfg (hns, hw->port_base_vlan_cfg.state, + hw->port_base_vlan_cfg.pvid); +if (err) +hns3_err (hw,"fail to rollback txvlan status, ret = %d" , err); + +return ret; } static int
Signature · 1 line
2.7.4
PATCH 5/10 net/hns3: fix flow control exception
In reply to Min Hu (Connor)From: Huisong Li <[email protected]>
In multi-TC scenarios, MAC pause is not supported. Otherwise, only TC0 can trigger pause frames, and other TCs cannot trigger pause frames. In this case, flow control does not meet the expectation.
--- drivers/net/hns3/hns3_ethdev.c | 5 +++++ 1 file changed, 5 insertions(+)
drivers/net/hns3/hns3_ethdev.c +5 -0
@@ -5500,6 +5500,11 @@ hns3_flow_ctrl_set(struct rte_eth_dev *dev, struct rte_eth_fc_conf *fc_conf)return -EOPNOTSUPP ; } +if (hw->num_tc >1 ) { +hns3_err (hw,"in multi-TC scenarios, MAC pause is not supported." ); +return -EOPNOTSUPP ; + } +hns3_get_fc_mode (hw, fc_conf->mode);if (hw->requested_mode == hw->current_mode && pf->pause_time == fc_conf->pause_time)
Signature · 1 line
2.7.4
PATCH 6/10 net/hns3: fix flow counter not cleared when create
In reply to Min Hu (Connor)From: Chengwen Feng <[email protected]>
User could create flow rules with specified counter by the action of RTE_FLOW_ACTION_TYPE_COUNT, but the counter may retain the original value when create.
This patch fix the bug by read the counter when creating the rule because the counter is read-clear.
--- drivers/net/hns3/hns3_flow.c | 10 ++++++++++ 1 file changed, 10 insertions(+)
drivers/net/hns3/hns3_flow.c +10 -0
@@ -158,7 +158,10 @@ hns3_counter_new(struct rte_eth_dev *dev, uint32_t shared, uint32_t id, {struct hns3_adapter *hns = dev->data->dev_private;struct hns3_pf *pf = &hns->pf; +struct hns3_hw *hw = &hns->hw;struct hns3_flow_counter *cnt; +uint64_t value; +int ret; cnt =hns3_counter_lookup (dev, id);if (cnt) {
@@ -171,6 +174,13 @@ hns3_counter_new(struct rte_eth_dev *dev, uint32_t shared, uint32_t id,return 0 ; } +/* Clear the counter by read ops because the counter is read-clear */ + ret =hns3_get_count (hw, id, &value); +if (ret) +return rte_flow_error_set (error,EIO , +RTE_FLOW_ERROR_TYPE_HANDLE ,NULL , +"Clear counter failed!" ); + cnt =rte_zmalloc ("hns3 counter" ,sizeof (*cnt),0 );if (cnt ==NULL ) return rte_flow_error_set(error, ENOMEM,
Signature · 1 line
2.7.4
PATCH 7/10 net/hns3: fix VF mailbox head field wrong update
In reply to Min Hu (Connor)From: Chengwen Feng <[email protected]>
Currently, the VF mailbox synchronization communication is based on three fields: head/tail/lost, when head equals tail plus lost, it means the response is received successfully.
The head field indicates the number of requests that are successfully sent. If the request sending fails, it should not be updated.
This patch fix the above bug by roll back updates when the sending fails.
--- drivers/net/hns3/hns3_mbx.c | 1 + 1 file changed, 1 insertion(+)
drivers/net/hns3/hns3_mbx.c +1 -0
@@ -142,6 +142,7 @@ hns3_send_mbx_msg(struct hns3_hw *hw, uint16_t code, uint16_t subcode, hw->mbx_resp.head++; ret =hns3_cmd_send (hw, &desc,1 );if (ret) { + hw->mbx_resp.head--;rte_spinlock_unlock (&hw->mbx_resp.lock);hns3_err (hw,"VF failed(=%d) to send mbx message to PF" , ret);
Signature · 1 line
2.7.4
PATCH 8/10 net/hns3: support get device version when dump register
In reply to Min Hu (Connor)From: Chengwen Feng <[email protected]>
Support get device version which is equal to the firmware version when dump register.
--- drivers/net/hns3/hns3_regs.c | 2 ++ 1 file changed, 2 insertions(+)
drivers/net/hns3/hns3_regs.c +2 -0
@@ -504,6 +504,8 @@ hns3_get_regs(struct rte_eth_dev *eth_dev, struct rte_dev_reg_info *regs)if (regs->length && regs->length != length)return -ENOTSUP ; + regs->version = hw->fw_version; +/* fetching per-PF registers values from PF PCIe register space */ data +=hns3_direct_access_regs (hw, data);
Signature · 1 line
2.7.4
PATCH 9/10 net/hns3: delete redundant blank line
In reply to Min Hu (Connor)From: Hongbo Zheng <[email protected]>
Delete redundant blank line in "hns3vf_check_event_cause" to solve the static warning.
--- drivers/net/hns3/hns3_ethdev_vf.c | 1 - 1 file changed, 1 deletion(-)
drivers/net/hns3/hns3_ethdev_vf.c +0 -1
@@ -1064,7 +1064,6 @@ hns3vf_check_event_cause(struct hns3_adapter *hns, uint32_t *clearval)/* Fetch the events from their corresponding regs */ cmdq_stat_reg =hns3_read_dev (hw,HNS3_VECTOR0_CMDQ_STAT_REG ); -if (BIT (HNS3_VECTOR0_RST_INT_B ) & cmdq_stat_reg) { rst_ing_reg =hns3_read_dev (hw,HNS3_FUN_RST_ING );hns3_warn (hw,"resetting reg: 0x%x" , rst_ing_reg);
Signature · 1 line
2.7.4
PATCH 10/10 net/hns3: fix code style static warning
In reply to Min Hu (Connor)From: Hongbo Zheng <[email protected]>
Add one space before the left brace to solve the static warning.
--- drivers/net/hns3/hns3_rxtx.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-)
drivers/net/hns3/hns3_rxtx.c +1 -1
@@ -4438,7 +4438,7 @@ hns3_dev_rx_descriptor_status(void *rx_queue, uint16_t offset)if (offset >= rxq->nb_rx_desc - rxq->rx_free_hold)return RTE_ETH_RX_DESC_UNAVAIL ; }else if (dev->rx_pkt_burst == hns3_recv_pkts_vec || - dev->rx_pkt_burst == hns3_recv_pkts_vec_sve){ + dev->rx_pkt_burst == hns3_recv_pkts_vec_sve) {if (offset >= rxq->nb_rx_desc - rxq->rx_rearm_nb)return RTE_ETH_RX_DESC_UNAVAIL ; }else {
Signature · 1 line
2.7.4
Quoted 11 lines · Min Hu (Connor)
This set of patches are bugfixes for hns3 PMD.
Chengchang Tang (1):
net/hns3: fix lack of rollback after setting PVID failedChengwen Feng (4):
net/hns3: fix set default MAC addr fail in bonding of VF net/hns3: fix flow counter not cleared when create net/hns3: fix VF mailbox head field wrong update net/hns3: support get device version when dump register
Quoted 9 lines
Hongbo Zheng (3):
net/hns3: fix the FLR miss detection
net/hns3: delete redundant blank line
net/hns3: fix code style static warningHuisong Li (2):
net/hns3: fix some function names for copper media type net/hns3: fix flow control exception
Series applied to dpdk-next-net/main, thanks.