usb: image: microtek: don't receive REQUEST SENSE data into sense_buffer
Subsystems (3)
PATCH 1/1 usb: image: microtek: don't receive REQUEST SENSE data into sense_buffer
mts_command_done() receives the data phase of a REQUEST SENSE into srb->sense_buffer (SCSI_SENSE_BUFFERSIZE, 96 bytes), but with the length of the command's own data buffer. A REQUEST SENSE sent through SG_IO, allowed on a read-only /dev/sgN without any capability, can have a much larger buffer (252 bytes with sg_requests), and a device that returns that much writes past the end of the sense buffer.
The special case is not needed: for the error handler's own REQUEST SENSE, scsi_eh_prep_cmnd() already points the data buffer at sense_buffer with at most SCSI_SENSE_BUFFERSIZE. Handle REQUEST SENSE like every other data-in command.
The bug was found, and the reproducer and this fix were written, by AI agents (Claude Mythos and Claude Opus models). The analysis and the patch were reviewed by a human.
---
An emulated ScanMaker X6 answering a 252-byte SG_IO REQUEST SENSE with 252 bytes triggers it (KASAN in dummy_timer, the HCD's copy into the URB buffer; slub_debug redzone report with xHCI), on v7.3.1 and master 9d66f26fefac. No reports with the fix. User-space REQUEST SENSE now gets the sense data in its own buffer; the error handler's REQUEST SENSE returns the same data as before. Not tested on real hardware. Reproducer available on request.
drivers/usb/image/microtek.c | 19 ++++++------------- 1 file changed, 6 insertions(+), 13 deletions(-)
drivers/usb/image/microtek.c +6 -13
@@ -445,22 +445,15 @@ static void mts_command_done( struct urb *transfer )return ; } -if (context->srb->cmnd[0 ] ==REQUEST_SENSE ) { +if (context->data) {mts_int_submit_urb (transfer, context->data_pipe, - context->srb->sense_buffer, + context->data, context->data_length, - mts_data_done); - }else {if ( context->data ) { -mts_int_submit_urb (transfer, - context->data_pipe, - context->data, - context->data_length, -scsi_sg_count (context->srb) >1 ? - mts_do_sg : mts_data_done); - }else { -mts_get_status (transfer); - } +scsi_sg_count (context->srb) >1 ? + mts_do_sg : mts_data_done); + }else { +mts_get_status (transfer); } }
Signature · 1 line
2.53.0
[email protected]
AI reviewSashiko has reviewed this patch and found no issues.
Quoted 12 lines
mts_command_done()receives the data phase of a REQUEST SENSE intosrb->sense_buffer(SCSI_SENSE_BUFFERSIZE, 96 bytes), but with the length of the command's own data buffer. A REQUEST SENSE sent throughSG_IO, allowed on a read-only/dev/sgNwithout any capability, can have a much larger buffer (252 bytes withsg_requests), and a device that returns that much writes past the end of the sense buffer.The special case is not needed: for the error handler's own REQUEST SENSE,
scsi_eh_prep_cmnd()already points the data buffer atsense_bufferwith at mostSCSI_SENSE_BUFFERSIZE. Handle REQUEST SENSE like every other data-in command.
Quoted 7 lines
The bug was found, and the reproducer and this fix were written, by AI agents (Claude Mythos and Claude Opus models). The analysis and the patch were reviewed by a human.
Fixes 1da177e4c3f4 ("Linux-2.6.12-rc2")Signed-off-by Alexandre Becholey <[email protected]>
Sashiko has reviewed this patch and found no issues.
Signature · 1 line
Sashiko AI review · https://sashiko.dev/#/patchset/[email protected]?part=1
Quoted 4 lines · Alexandre Becholey
The special case is not needed: for the error handler's own REQUEST SENSE,
scsi_eh_prep_cmnd()already points the data buffer atsense_bufferwith at mostSCSI_SENSE_BUFFERSIZE. Handle REQUEST SENSE like every other data-in command.
Hi,
thank you for looking at this, but this fix seems to not take an approach I can approve. Where sense_buffer is pointed to is internal to the SCSI layer. We cannot use that in an LLD.
If you think that LLDs should not use sense_buffer then the clean solution is to remove it from struct scsi_cmnd.
Regards
Oliver
Quoted 12 lines · Oliver Neukum
Quoted 4 lines · Alexandre Becholey
The special case is not needed: for the error handler's own REQUEST SENSE,
scsi_eh_prep_cmnd()already points the data buffer atsense_bufferwith at mostSCSI_SENSE_BUFFERSIZE. Handle REQUEST SENSE like every other data-in command.Hi,
thank you for looking at this, but this fix seems to not take an approach I can approve. Where
sense_bufferis pointed to is internal to the SCSI layer. We cannot use that in an LLD.
Quoted 8 lines
If you think that LLDs should not use
sense_bufferthen the clean solution is to remove it from structscsi_cmnd.Regards
OliverNACKED-BY Oliver Neukum <[email protected]>
Hi Oliver,
Would you take a v2 that keeps receiving the REQUEST SENSE data into sense_buffer and only limits the transfer to SCSI_SENSE_BUFFERSIZE?
if (context->srb->cmnd[0] == REQUEST_SENSE) {
mts_int_submit_urb(transfer,
context->data_pipe,
context->srb->sense_buffer,
min_t(unsigned int, context->data_length,
SCSI_SENSE_BUFFERSIZE),
mts_data_done);The device can then no longer write past the 96-byte buffer, and nothing else changes.
Kind regards,
Alexandre
Quoted 20 lines · Alexandre Becholey
Quoted 18 lines · Oliver Neukum
Quoted 4 lines · Alexandre Becholey
The special case is not needed: for the error handler's own REQUEST SENSE,
scsi_eh_prep_cmnd()already points the data buffer atsense_bufferwith at mostSCSI_SENSE_BUFFERSIZE. Handle REQUEST SENSE like every other data-in command.Hi,
thank you for looking at this, but this fix seems to not take an approach I can approve. Where
sense_bufferis pointed to is internal to the SCSI layer. We cannot use that in an LLD.If you think that LLDs should not use
sense_bufferthen the clean solution is to remove it from structscsi_cmnd.Regards
Oliver
Quoted 6 lines
Quoted 2 lines
NACKED-BY Oliver Neukum <[email protected]>Hi Oliver,
Would you take a v2 that keeps receiving the REQUEST SENSE data into
sense_bufferand only limits the transfer toSCSI_SENSE_BUFFERSIZE?
Hi,
sure that would be fine.
Yet, I am afraid I have to ask why you want to solve this issue at the level of the LLD? This looks like a generic issue to me. The size of sense_buffer is documented. I don't see how this issue can be limited to microtek.
Regards
Oliver
Quoted 25 lines · Oliver Neukum
Quoted 22 lines · Alexandre Becholey
Quoted 20 lines · Oliver Neukum
Quoted 4 lines · Alexandre Becholey
The special case is not needed: for the error handler's own REQUEST SENSE,
scsi_eh_prep_cmnd()already points the data buffer atsense_bufferwith at mostSCSI_SENSE_BUFFERSIZE. Handle REQUEST SENSE like every other data-in command.Hi,
thank you for looking at this, but this fix seems to not take an approach I can approve. Where
sense_bufferis pointed to is internal to the SCSI layer. We cannot use that in an LLD.If you think that LLDs should not use
sense_bufferthen the clean solution is to remove it from structscsi_cmnd.Regards
OliverNACKED-BY Oliver Neukum <[email protected]>
Quoted 8 lines
Quoted 4 lines
Hi Oliver,
Would you take a v2 that keeps receiving the REQUEST SENSE data into
sense_bufferand only limits the transfer toSCSI_SENSE_BUFFERSIZE?Hi,
sure that would be fine.
Thanks, v2 will do that.
Quoted 10 lines
Yet, I am afraid I have to ask why you want to solve this issue at the level of the LLD? This looks like a generic issue to me. The size of
sense_bufferis documented. I don't see how this issue can be limited to microtek.Regards
Oliver
The overflow comes from microtek receiving the data phase of a REQUEST SENSE command into sense_buffer with the length of the command's own data buffer. That length is chosen by whoever sends the command (sg allows REQUEST SENSE on a read-only node) and has nothing to do with sense_buffer, so I don't think the core can see the problem.
I looked at the other drivers for that special-case REQUEST SENSE (in drivers/scsi, drivers/ata and drivers/usb). They either transfer its data into the command's data buffer like any other data-in command, or emulate it there. I found no other driver that copies a caller-sized transfer into sense_buffer, so I think the fix belongs in microtek. If you see a place where the core should enforce the size, I am happy to look at it.
Kind regards,
Alexandre
Quoted 7 lines · Alexandre Becholey
I looked at the other drivers for that special-case REQUEST SENSE (in
drivers/scsi,drivers/ataanddrivers/usb). They either transfer its data into the command's data buffer like any other data-in command, or emulate it there. I found no other driver that copies a caller-sized transfer intosense_buffer, so I think the fix belongs in microtek. If you see a place where the core should enforce the size, I am happy to look at it.
Thank you, that makes the situation clearer. Yet it kind of brings back one question: Why does scsi_cmnd have the member sense_buffer at all, if you simple can write the result into the generic buffer?
I have no problem with cleaning up an issue in the microtek driver, but if an issue is to be cleaned up, it should be done fully.
Regards
Oliver