netsnmp: install all MIB files
PATCH 1/1 netsnmp: install all MIB files
Since commit be8e32d585f3 ("netsnmp: configurable MIB modules"), the list of MIB modules can be selected with a configuration option.
However, there was still an hardcoded list of MIB files to exclude from the target filesystem.
Since it is complicated to know which MIB files are necessary according to the configuration, let's install all of them.
--- package/netsnmp/netsnmp.mk | 10 ---------- 1 file changed, 10 deletions(-)
package/netsnmp/netsnmp.mk +0 -10
@@ -38,8 +38,6 @@ NETSNMP_MAKE = $(MAKE1) NETSNMP_CONFIG_SCRIPTS = net-snmp-config NETSNMP_AUTORECONF = YES -NETSNMP_BLOAT_MIBS = BRIDGE DISMAN-EVENT DISMAN-SCHEDULE DISMAN-SCRIPT EtherLike RFC-1215 RFC1155-SMI RFC1213 SCTP SMUX - ifeq ($(BR2_ENDIAN),"BIG") NETSNMP_CONF_OPTS += --with-endianness=big else
@@ -101,14 +99,6 @@ else NETSNMP_CONF_OPTS += --disable-applications endif -define NETSNMP_REMOVE_BLOAT_MIBS - for mib in $(NETSNMP_BLOAT_MIBS); do \ - rm -f $(TARGET_DIR)/usr/share/snmp/mibs/$$mib-MIB.txt; \ - done -endef - -NETSNMP_POST_INSTALL_TARGET_HOOKS += NETSNMP_REMOVE_BLOAT_MIBS - ifeq ($(BR2_PACKAGE_NETSNMP_SERVER),y) define NETSNMP_INSTALL_INIT_SYSV $(INSTALL) -D -m 0755 package/netsnmp/S59snmpd \
Signature · 1 line
2.13.1
PATCH 1/1 netsnmp: install all MIB files
Quoted 11 lines · Julien Floret
Since commit
be8e32d585f3("netsnmp: configurable MIB modules"), the list of MIB modules can be selected with a configuration option.However, there was still an hardcoded list of MIB files to exclude from the target filesystem.
Since it is complicated to know which MIB files are necessary according to the configuration, let's install all of them.Cc przemyslaw <[email protected]>Cc Gustavo Zacarias <[email protected]>Signed-off-by Julien Floret <[email protected]>
Looks good to me, except: shouldn't the default ofBR2_PACKAGE_NETSNMP_WITHOUT_MIB_MODULES so that all the previous BLOAT_MIBS are there?
Regards,
Arnout
Signature · 6 lines
Arnout Vandecappelle arnout at mind be Senior Embedded Software Architect +32-16-286500 Essensium/Mind http://www.mind.be G.Geenslaan 9, 3001 Leuven, Belgium BE 872 984 063 RPR Leuven LinkedIn profile: http://www.linkedin.com/in/arnoutvandecappelle GPG fingerprint: 7493 020B C7E3 8618 8DEC 222C 82EB F404 F9AC 0DDF
PATCH 1/1 netsnmp: install all MIB files
Hello Arnout,
2017-09-12 1:08 GMT+02:00 Arnout Vandecappelle <[email protected]>:
Quoted 11 lines · Julien Floret
Quoted 8 lines
Since commit
be8e32d585f3("netsnmp: configurable MIB modules"), the list of MIB modules can be selected with a configuration option.However, there was still an hardcoded list of MIB files to exclude from the target filesystem.
Since it is complicated to know which MIB files are necessary according to the configuration, let's install all of them.
Quoted 7 lines
Quoted 3 lines
Cc przemyslaw <[email protected]>Cc Gustavo Zacarias <[email protected]>Signed-off-by Julien Floret <[email protected]>Looks good to me, except: shouldn't the default of
BR2_PACKAGE_NETSNMP_WITHOUT_MIB_MODULESso that all the previousBLOAT_MIBSare there?
Hum, maybe we could parse BR2_PACKAGE_NETSNMP_{WITH,WITHOUT}_MIB_MODULES to deduce BLOAT_MIBS, but to me it does not seem trivial nor elegant...
What about adding a new config option BR2_NETSNMP_WITHOUT_MIB_FILES whose default value is the content of BLOAT_MIBS?
PATCH 1/1 netsnmp: install all MIB files
Quoted 22 lines · Julien Floret
Hello Arnout,
2017-09-12 1:08 GMT+02:00 Arnout Vandecappelle <[email protected]>:
Quoted 11 lines · Julien Floret
Quoted 8 lines
Since commit
be8e32d585f3("netsnmp: configurable MIB modules"), the list of MIB modules can be selected with a configuration option.However, there was still an hardcoded list of MIB files to exclude from the target filesystem.
Since it is complicated to know which MIB files are necessary according to the configuration, let's install all of them.Quoted 7 lines
Quoted 3 lines
Cc przemyslaw <[email protected]>Cc Gustavo Zacarias <[email protected]>Signed-off-by Julien Floret <[email protected]>Looks good to me, except: shouldn't the default of
BR2_PACKAGE_NETSNMP_WITHOUT_MIB_MODULESso that all the previousBLOAT_MIBSare there?
Quoted 5 lines
Hum, maybe we could parse BR2_PACKAGE_NETSNMP_{WITH,WITHOUT}_MIB_MODULES to deduce
BLOAT_MIBS, but to me it does not seem trivial nor elegant...
What about adding a new config optionBR2_NETSNMP_WITHOUT_MIB_FILESwhose default value is the content ofBLOAT_MIBS?
Let me rephrase my comment.
What this patch does, basically, is to clean up the discrepancy between
BR2_PACKAGE_NETSNMP_{WITH,WITHOUT}_MIB_MODULES and BLOAT_MIBS. That is absolutely a good thing.
It looks to me like the current BLOAT_MIBS option is removing stuff that is
already disabled by the default value of BR2_PACKAGE_NETSNMP_WITHOUT_MIB_MODULES. So that part is fine - your patch is not actually changing anything in the default configuration.
However, it looks to me like the current BLOAT_MIBS is also removing things
that are *not* included in the current default value of BR2_PACKAGE_NETSNMP_WITHOUT_MIB_MODULES. Therefore, after this change, we end up with a bigger rootfs (using defaults) than before.
My suggestion is: wouldn't it make sense to extend the default value ofBR2_PACKAGE_NETSNMP_WITHOUT_MIB_MODULES? As far as I can see, the current default removes DISMAN-EVENT and DISMAN-SCHEDULE already. Are there additional modules we can disable, so that also BRIDGE DISMAN-SCRIPT EtherLike RFC-1215 RFC1155-SMI RFC1213 SCTP and SMUX are gone? And can we do this without loosing functionality that we did have before?
Probably extending BR2_PACKAGE_NETSNMP_WITHOUT_MIB_MODULES should be a separate
patch anyway.
Regards,
Arnout
Signature · 6 lines
Arnout Vandecappelle arnout at mind be Senior Embedded Software Architect +32-16-286500 Essensium/Mind http://www.mind.be G.Geenslaan 9, 3001 Leuven, Belgium BE 872 984 063 RPR Leuven LinkedIn profile: http://www.linkedin.com/in/arnoutvandecappelle GPG fingerprint: 7493 020B C7E3 8618 8DEC 222C 82EB F404 F9AC 0DDF
PATCH 1/1 netsnmp: install all MIB files
2017-09-12 13:44 GMT+02:00 Arnout Vandecappelle <[email protected]>:
Quoted 47 lines · Julien Floret
Quoted 22 lines
Hello Arnout,
2017-09-12 1:08 GMT+02:00 Arnout Vandecappelle <[email protected]>:
Quoted 11 lines · Julien Floret
Quoted 8 lines
Since commit
be8e32d585f3("netsnmp: configurable MIB modules"), the list of MIB modules can be selected with a configuration option.However, there was still an hardcoded list of MIB files to exclude from the target filesystem.
Since it is complicated to know which MIB files are necessary according to the configuration, let's install all of them.Quoted 7 lines
Quoted 3 lines
Cc przemyslaw <[email protected]>Cc Gustavo Zacarias <[email protected]>Signed-off-by Julien Floret <[email protected]>Looks good to me, except: shouldn't the default of
BR2_PACKAGE_NETSNMP_WITHOUT_MIB_MODULESso that all the previousBLOAT_MIBSare there?Quoted 5 lines
Hum, maybe we could parse BR2_PACKAGE_NETSNMP_{WITH,WITHOUT}_MIB_MODULES to deduce
BLOAT_MIBS, but to me it does not seem trivial nor elegant...
What about adding a new config optionBR2_NETSNMP_WITHOUT_MIB_FILESwhose default value is the content ofBLOAT_MIBS?Let me rephrase my comment.
What this patch does, basically, is to clean up the discrepancy between
BR2_PACKAGE_NETSNMP_{WITH,WITHOUT}_MIB_MODULES andBLOAT_MIBS. That is absolutely a good thing.It looks to me like the current
BLOAT_MIBSoption is removing stuff that is
already disabled by the default value ofBR2_PACKAGE_NETSNMP_WITHOUT_MIB_MODULES. So that part is fine - your patch is not actually changing anything in the default configuration.However, it looks to me like the current
BLOAT_MIBSis also removing things
that are *not* included in the current default value ofBR2_PACKAGE_NETSNMP_WITHOUT_MIB_MODULES. Therefore, after this change, we end up with a bigger rootfs (using defaults) than before.
Quoted 6 lines
My suggestion is: wouldn't it make sense to extend the default value of
BR2_PACKAGE_NETSNMP_WITHOUT_MIB_MODULES? As far as I can see, the current default removes DISMAN-EVENT and DISMAN-SCHEDULE already. Are there additional modules we can disable, so that also BRIDGE DISMAN-SCRIPT EtherLike RFC-1215 RFC1155-SMI RFC1213 SCTP and SMUX are gone? And can we do this without loosing functionality that we did have before?
Thanks for the detailed response, now I understand better your comment.
Honestly, I could not tell... netsnmp is quite complicated. Ensuring we don't lose any functionality after changing the default modules would probably require a deeper investigation and knowledge of netsnmp code that I'm not able to do right now. And it seems netsnmp "make install" installs MIB description files, whether or not the module(s) using them are enabled or not.
What's more, if I recall correctly, modules can still work without their MIB description file - they just cannot translate object IDs into human-readable names.
But without this patch, netsnmp is unusable for us, because we need the object names and this hardcoded BLOAT_MIBS list removes mandatory MIB files whatever the configuration options.
(By the way, some of the MIBS in BLOAT_MIBS (RFC-1215 and RFC1155-SMI) don't seem to be suppressed, because the suffix added in NETSNMP_REMOVE_BLOAT_MIBS ("-MIB.txt") doesn't apply for them...)
Quoted 2 lines
Probably extending
BR2_PACKAGE_NETSNMP_WITHOUT_MIB_MODULESshould be a separate
patch anyway.
Yes, probably. I'm not sure these default values are the most common case, however.
Also, IMHO having two options {WITH,WITHOUT}_MIB_MODULES makes quite difficult to know which modules are really enabled in the end. I'm starting to think that maybe a better approach would be to have one Config.in option per module... This would be clearer and would perhaps also allow removing unused MIB files according to the modules that are enabled or not.
So do you think this patch is acceptable for now?
Arnout Vandecappelle
AppliedPATCH 1/1 netsnmp: install all MIB files
On 13-09-17 14:16, Julien Floret wrote:
[snip]
Quoted 9 lines
Honestly, I could not tell... netsnmp is quite complicated. Ensuring we don't lose any functionality after changing the default modules would probably require a deeper investigation and knowledge of netsnmp code that I'm not able to do right now. And it seems netsnmp "make install" installs MIB description files, whether or not the module(s) using them are enabled or not.
What's more, if I recall correctly, modules can still work without their MIB description file - they just cannot translate object IDs into human-readable names.
OK. Well, the only thing this patch does, in the end, is make the target
filesystem a bit bigger. By how much, do you know?
Users can always remove unneeded MIBs in a post-build script.
Quoted 3 lines
But without this patch, netsnmp is unusable for us, because we need the object names and this hardcoded
BLOAT_MIBSlist removes mandatory MIB files whatever the configuration options.
That's a good reason!
Quoted 3 lines
(By the way, some of the MIBS in
BLOAT_MIBS(RFC-1215 and RFC1155-SMI) don't seem to be suppressed, because the suffix added inNETSNMP_REMOVE_BLOAT_MIBS("-MIB.txt") doesn't apply for them...)
Yeah, the option is from the very first time the package was added 7 years ago,
and hasn't been updated through all the version bumps...
Quoted 5 lines
Quoted 2 lines
Probably extending
BR2_PACKAGE_NETSNMP_WITHOUT_MIB_MODULESshould be a separate
patch anyway.Yes, probably. I'm not sure these default values are the most common case, however.
Never mind that, since it's anyway not really related, as you say.
Quoted 6 lines
Also, IMHO having two options {WITH,WITHOUT}_MIB_MODULES makes quite difficult to know which modules are really enabled in the end. I'm starting to think that maybe a better approach would be to have one Config.in option per module... This would be clearer and would perhaps also allow removing unused MIB files according to the modules that are enabled or not.
But that would make for a really long list of options, no? I think that that's
a bit too much.
Quoted 2 lines
So do you think this patch is acceptable for now?
I've applied, thanks.
Perhaps you could write up a CHANGES entry that explains that people should
remove unneeded MIBs in a post-build script?
Regards,
Arnout
Signature · 6 lines
Arnout Vandecappelle arnout at mind be Senior Embedded Software Architect +32-16-286500 Essensium/Mind http://www.mind.be G.Geenslaan 9, 3001 Leuven, Belgium BE 872 984 063 RPR Leuven LinkedIn profile: http://www.linkedin.com/in/arnoutvandecappelle GPG fingerprint: 7493 020B C7E3 8618 8DEC 222C 82EB F404 F9AC 0DDF
PATCH 1/1 netsnmp: install all MIB files
2017-09-13 23:24 GMT+02:00 Arnout Vandecappelle <[email protected]>:
[snip]
Quoted 2 lines
OK. Well, the only thing this patch does, in the end, is make the target
filesystem a bit bigger. By how much, do you know?
Approximately 400K...
Quoted 33 lines
Users can always remove unneeded MIBs in a post-build script.
Quoted 3 lines
But without this patch, netsnmp is unusable for us, because we need the object names and this hardcoded
BLOAT_MIBSlist removes mandatory MIB files whatever the configuration options.That's a good reason!
Quoted 3 lines
(By the way, some of the MIBS in
BLOAT_MIBS(RFC-1215 and RFC1155-SMI) don't seem to be suppressed, because the suffix added inNETSNMP_REMOVE_BLOAT_MIBS("-MIB.txt") doesn't apply for them...)Yeah, the option is from the very first time the package was added 7 years ago,
and hasn't been updated through all the version bumps...Quoted 5 lines
Quoted 2 lines
Probably extending
BR2_PACKAGE_NETSNMP_WITHOUT_MIB_MODULESshould be a separate
patch anyway.Yes, probably. I'm not sure these default values are the most common case, however.
Never mind that, since it's anyway not really related, as you say.
Quoted 6 lines
Also, IMHO having two options {WITH,WITHOUT}_MIB_MODULES makes quite difficult to know which modules are really enabled in the end. I'm starting to think that maybe a better approach would be to have one Config.in option per module... This would be clearer and would perhaps also allow removing unused MIB files according to the modules that are enabled or not.
Quoted 3 lines
But that would make for a really long list of options, no? I think that that's
a bit too much.
That's right, that would make maybe 20 options... OK, it's probably better to stick to the current options.
Quoted 8 lines
Quoted 3 lines
So do you think this patch is acceptable for now?
I've applied, thanks.
Perhaps you could write up a CHANGES entry that explains that people should
remove unneeded MIBs in a post-build script?
OK, I will see what I can do. Thanks!