be2net: Allow a VF to use physical link state.

PATCH In review David Wilder 2 participants 4 messages Jun 9, 2020 – Jun 10, 2020

Subsystems (3)
lore
Share & tools
lore
#0 lore raw

PATCH 1/1 be2net: Allow a VF to use physical link state.

Hyper-visors owning a PF are allowed by Emulex specification to provide a VF with separate physical and/or logical link states. However, on linux, a VF driver must chose one or the other.

My scenario is a proprietary driver controlling the PF, be2net is the VF. When I do a physical cable pull test the PF sends a link event notification to the VF with the "physical" link status but this is ignored in be2net (see be_async_link_state_process() ).

The PF is reporting the adapter type as:
0xe228 /* Device id for VF in Lancer */

I added a module parameter "use_pf_link_state". When set the VF should ignore logical link state and use the physical link state.

However I have an issue making this work. When the cable is pulled I see two link statuses reported:

[1706100.767718] be2net 8002:01:00.0 eth1: Link is Down
[1706101.189298] be2net 8002:01:00.0 eth1: Link is Up

be_link_status_update() is called twice, the first with the physical link status called from be_async_link_state_process(), and the second with the logical link status from be_get_link_ksettings().

I am unsure why be_async_link_state_process() is called from be_get_link_ksettings(), it results in multiple link state changes (even in the un-patched case). If I eliminate this call then it works. But I am un-sure of this change.

---
 drivers/net/ethernet/emulex/benet/be_cmds.c    | 9 ++++++++-
 drivers/net/ethernet/emulex/benet/be_ethtool.c | 2 --
 drivers/net/ethernet/emulex/benet/be_main.c    | 4 ++++
 3 files changed, 12 insertions(+), 3 deletions(-)
drivers/net/ethernet/emulex/benet/be_cmds.c +8 -1
index 701c12c..52934b2 100644
@@ -278,6 +278,8 @@ static int be_mcc_compl_process(struct be_adapter *adapter,
 	return compl->status;
 }
 
+extern int use_pf_link_state;
+
 /* Link state evt is a string of bytes; no need for endian swapping */
 static void be_async_link_state_process(struct be_adapter *adapter,
 					struct be_mcc_compl *compl)
@@ -288,13 +290,18 @@ static void be_async_link_state_process(struct be_adapter *adapter,
 	/* When link status changes, link speed must be re-queried from FW */
 	adapter->phy.link_speed = -1;
 
+	if (use_pf_link_state &&
+	    evt->port_link_status & LOGICAL_LINK_STATUS_MASK)
+		return;
+
 	/* On BEx the FW does not send a separate link status
 	 * notification for physical and logical link.
 	 * On other chips just process the logical link
 	 * status notification
 	 */
 	if (!BEx_chip(adapter) &&
-	    !(evt->port_link_status & LOGICAL_LINK_STATUS_MASK))
+	    !(evt->port_link_status & LOGICAL_LINK_STATUS_MASK) &&
+	    !use_pf_link_state)
 		return;
 
 	/* For the initial link status do not rely on the ASYNC event as
drivers/net/ethernet/emulex/benet/be_ethtool.c +0 -2
index d6ed1d9..fd91d63 100644
@@ -618,8 +618,6 @@ static int be_get_link_ksettings(struct net_device *netdev,
 	if (adapter->phy.link_speed < 0) {
 		status = be_cmd_link_status_query(adapter, &link_speed,
 						  &link_status, 0);
-		if (!status)
-			be_link_status_update(adapter, link_status);
 		cmd->base.speed = link_speed;
 
 		status = be_cmd_get_phy_info(adapter);
drivers/net/ethernet/emulex/benet/be_main.c +4 -0
index a7ac23a..1020be6 100644
@@ -36,6 +36,10 @@
 module_param(rx_frag_size, ushort, 0444);
 MODULE_PARM_DESC(rx_frag_size, "Size of a fragment that holds rcvd data.");
 
+unsigned int use_pf_link_state;
+module_param(use_pf_link_state, uint, 0444);
+MODULE_PARM_DESC(use_pf_link_state, "Use physical link state");
+
 /* Per-module error detection/recovery workq shared across all functions.
  * Each function schedules its own work request on this shared workq.
  */
Signature · 1 line
1.8.3.1
maintainer
#1 lore raw
Quoted 24 lines · On Mon, 8 Jun 2020 17:00:59 -0700 David Wilder wrote:

Hyper-visors owning a PF are allowed by Emulex specification to provide a VF with separate physical and/or logical link states. However, on linux, a VF driver must chose one or the other.

My scenario is a proprietary driver controlling the PF, be2net is the VF. When I do a physical cable pull test the PF sends a link event notification to the VF with the "physical" link status but this is ignored in be2net (see be_async_link_state_process() ).

The PF is reporting the adapter type as:
0xe228 /* Device id for VF in Lancer */

I added a module parameter "use_pf_link_state". When set the VF should ignore logical link state and use the physical link state.

However I have an issue making this work. When the cable is pulled I see two link statuses reported:

[1706100.767718] be2net 8002:01:00.0 eth1: Link is Down
[1706101.189298] be2net 8002:01:00.0 eth1: Link is Up

be_link_status_update() is called twice, the first with the physical link status called from be_async_link_state_process(), and the second with the logical link status from be_get_link_ksettings().

Quoted 6 lines

I am unsure why be_async_link_state_process() is called from be_get_link_ksettings(), it results in multiple link state changes (even in the un-patched case). If I eliminate this call then it works. But I am un-sure of this change.

Hm. Just looking at the code in __be_cmd_set_logical_link_config():

	if (link_state == IFLA_VF_LINK_STATE_ENABLE ||
	    link_state == IFLA_VF_LINK_STATE_AUTO)
		link_config |= PLINK_ENABLE;

	if (link_state == IFLA_VF_LINK_STATE_AUTO)
		link_config |= PLINK_TRACK;

Maybe we shouldn't set ENABLE for AUTO?

The module parameter is definitely not a good idea, what you're asking for seems to be well within the expectation from the .ndo_set_vf_link_state config, so it seems the driver / firmware is just not implementing that right.

author
#2 lore raw
Quoted 35 lines · Jakub Kicinski
Quoted 24 lines · On Mon, 8 Jun 2020 17:00:59 -0700 David Wilder wrote:

Hyper-visors owning a PF are allowed by Emulex specification to provide a VF with separate physical and/or logical link states. However, on linux, a VF driver must chose one or the other.

My scenario is a proprietary driver controlling the PF, be2net is the VF. When I do a physical cable pull test the PF sends a link event notification to the VF with the "physical" link status but this is ignored in be2net (see be_async_link_state_process() ).

The PF is reporting the adapter type as:
0xe228 /* Device id for VF in Lancer */

I added a module parameter "use_pf_link_state". When set the VF should ignore logical link state and use the physical link state.

However I have an issue making this work. When the cable is pulled I see two link statuses reported:

[1706100.767718] be2net 8002:01:00.0 eth1: Link is Down
[1706101.189298] be2net 8002:01:00.0 eth1: Link is Up

be_link_status_update() is called twice, the first with the physical link status called from be_async_link_state_process(), and the second with the logical link status from be_get_link_ksettings().

Quoted 6 lines

I am unsure why be_async_link_state_process() is called from be_get_link_ksettings(), it results in multiple link state changes (even in the un-patched case). If I eliminate this call then it works. But I am un-sure of this change.

Hm. Just looking at the code in __be_cmd_set_logical_link_config():

Quoted 8 lines
	if (link_state == IFLA_VF_LINK_STATE_ENABLE ||
	    link_state == IFLA_VF_LINK_STATE_AUTO)
		link_config |= PLINK_ENABLE;

	if (link_state == IFLA_VF_LINK_STATE_AUTO)
		link_config |= PLINK_TRACK;

Maybe we shouldn't set ENABLE for AUTO?

If I am understanding this correctly, this is used by the linux PF driver to configure how link status is delivered to a VF.

My problem is one of interoperability between the PF (not linux) and the VF is running on linux.
The PF driver is implemented to the Emulex/Broadcom spec, which allows a PF driver to be configured such that the VF can be notified of both physical and logical link status, separately.

Quoted 5 lines

The module parameter is definitely not a good idea, what you're asking for seems to be well within the expectation from the .ndo_set_vf_link_state config, so it seems the driver / firmware is just not implementing that right.

I am attempting to resolve an issue that the linux implementation cant conform to the the Emulex specification due to the implementation on linux.

maintainer
#3 lore raw
Quoted 47 lines · On Wed, 10 Jun 2020 10:22:22 -0700 dwilder wrote:
Quoted 46 lines · Jakub Kicinski
Quoted 28 lines · On Mon, 8 Jun 2020 17:00:59 -0700 David Wilder wrote:

Hyper-visors owning a PF are allowed by Emulex specification to provide
a VF with separate physical and/or logical link states. However, on linux, a VF driver must chose one or the other.

My scenario is a proprietary driver controlling the PF, be2net is the VF.
When I do a physical cable pull test the PF sends a link event notification to the VF with the "physical" link status but this is ignored in be2net (see be_async_link_state_process() ).

The PF is reporting the adapter type as:
0xe228 /* Device id for VF in Lancer */

I added a module parameter "use_pf_link_state". When set the VF should ignore logical link state and use the physical link state.

However I have an issue making this work. When the cable is pulled I see two link statuses reported:

[1706100.767718] be2net 8002:01:00.0 eth1: Link is Down
[1706101.189298] be2net 8002:01:00.0 eth1: Link is Up

be_link_status_update() is called twice, the first with the physical link
status called from be_async_link_state_process(), and the second with the
logical link status from be_get_link_ksettings().

Quoted 6 lines

I am unsure why be_async_link_state_process() is called from be_get_link_ksettings(), it results in multiple link state changes (even in the un-patched case). If I eliminate this call then it works. But I am un-sure of this change.

Hm. Just looking at the code in __be_cmd_set_logical_link_config():

	if (link_state == IFLA_VF_LINK_STATE_ENABLE ||
	    link_state == IFLA_VF_LINK_STATE_AUTO)
		link_config |= PLINK_ENABLE;

	if (link_state == IFLA_VF_LINK_STATE_AUTO)
		link_config |= PLINK_TRACK;
Quoted 7 lines
Quoted 1 line

Maybe we shouldn't set ENABLE for AUTO?

If I am understanding this correctly, this is used by the linux PF driver to configure how link status is delivered to a VF.

My problem is one of interoperability between the PF (not linux) and the VF is running on linux.

I see.

Quoted 3 lines

The PF driver is implemented to the Emulex/Broadcom spec, which allows a PF driver to be configured such that the VF can be notified of both physical and logical link status, separately.

We'd need a first-class support for this behavior both on PF and VF sides. A module parameter in one vendor driver to enable support for this behavior when running with a non-Linux PF driver is unlikely to succeed.

Quoted 9 lines
Quoted 5 lines

The module parameter is definitely not a good idea, what you're asking for seems to be well within the expectation from the .ndo_set_vf_link_state config, so it seems the driver / firmware is just
not implementing that right.

I am attempting to resolve an issue that the linux implementation cant conform to the the Emulex specification due to the implementation on linux.

Sadly I'd think that it's Emulex that needs to conform to Linux APIs, not the other way around.