cover AXI FAN new features and improvements

This series adds some new features to the axi-fan-control driver. On top of that, the HW had some changes (basically it now starts automatically out of reset) so that the driver needed some minor refactoring. The reason I'm sending this as RFC, is mainly because of the last patch ("hwmon: axi-fan-control: support temperature vs pwm points"). The core has some predefined values which define a temperature vs pwm curve [1]. It also exposes registers so that users can change it according to their needs. As I could not find standard attributes in the subsystem, I'm proposing some "raw" sysfs files. Looking at [2], the pwm_auto_point stuff looked to be what I want. Obviously I might be wrong :). If this is accepted, I will add a proper sysfs DOC file describing the new files (being lazy in the RFC).

For patch 5 ("hwmon: axi-fan-control: clear the fan fault irq at startup"), it's also arguable if we really need it. The main reason I have it is because of some userland apps that might take some drastic measures by just reading 1 fan_fault alarm. Obviously, we can argue that the problem is in the app and not in the driver. Though it's such a minimal change that I decided to include it (I'm more than fine in dropping the patch).

[1]: https://wiki.analog.com/resources/fpga/docs/axi_fan_control
[2]: https://www.kernel.org/doc/Documentation/hwmon/sysfs-interface

Nuno Sá (6):
hwmon: axi-fan-control: make sure the clock is enabled
hwmon: axi-fan-control: add tacho devicetree properties
dt-bindings: axi-fan-control: add tacho properties
hwmon: axi-fan-control: handle irqs in natural order
hwmon: axi-fan-control: clear the fan fault irq at startup
hwmon: axi-fan-control: support temperature vs pwm points

 .../bindings/hwmon/adi,axi-fan-control.yaml   |  12 ++
 drivers/hwmon/axi-fan-control.c               | 160 ++++++++++++++++--
 2 files changed, 156 insertions(+), 16 deletions(-)
Signature · 1 line
2.32.0
author maintainer
#1 lore raw

RFC PATCH 1/6 hwmon: axi-fan-control: make sure the clock is enabled

The core will only work if it's clock is enabled. This patch is a minor enhancement to make sure that's the case.

---
 drivers/hwmon/axi-fan-control.c | 13 +++++++++++++
 1 file changed, 13 insertions(+)
drivers/hwmon/axi-fan-control.c +13 -0
index e3f6b03e6764..901d1588234d 100644
@@ -351,6 +351,11 @@ static int axi_fan_control_init(struct axi_fan_control_data *ctl,
 	return ret;
 }
 
+static void axi_fan_control_clk_disable(void *clk)
+{
+	clk_disable_unprepare(clk);
+}
+
 static const struct hwmon_channel_info *axi_fan_control_info[] = {
 	HWMON_CHANNEL_INFO(pwm, HWMON_PWM_INPUT),
 	HWMON_CHANNEL_INFO(fan, HWMON_F_INPUT | HWMON_F_FAULT | HWMON_F_LABEL),
@@ -406,6 +411,14 @@ static int axi_fan_control_probe(struct platform_device *pdev)
 		return PTR_ERR(clk);
 	}
 
+	ret = clk_prepare_enable(clk);
+	if (ret)
+		return ret;
+
+	ret = devm_add_action_or_reset(&pdev->dev, axi_fan_control_clk_disable, clk);
+	if (ret)
+		return ret;
+
 	ctl->clk_rate = clk_get_rate(clk);
 	if (!ctl->clk_rate)
 		return -EINVAL;
Signature · 1 line
2.32.0
maintainer
#2 lore raw

Re: [RFC PATCH 1/6] hwmon: axi-fan-control: make sure the clock is enabled

Quoted 4 lines · Nuno Sá

The core will only work if it's clock is enabled. This patch is a minor enhancement to make sure that's the case.

Can I apply this patch as well as patches 4/6 and 5/6 as-is, or do they depend on patches 2/6 and 3/6 ?

Thanks,
Guenter

author maintainer
#3 lore raw

RE: [RFC PATCH 1/6] hwmon: axi-fan-control: make sure the clock is enabled

Quoted 17 lines

-----Original Message-----
From: Guenter Roeck <[email protected]> On Behalf Of Guenter Roeck
Sent: Saturday, July 17, 2021 7:25 PM
To: Sa, Nuno <[email protected]>
Cc: [email protected]; [email protected]; Rob Herring <[email protected]>; Jean Delvare <[email protected]>
Subject: Re: [RFC PATCH 1/6] hwmon: axi-fan-control: make sure the clock is enabled

Quoted 3 lines · Nuno Sá

The core will only work if it's clock is enabled. This patch is a minor enhancement to make sure that's the case.

Quoted 7 lines
Quoted 1 line

Can I apply this patch as well as patches 4/6 and 5/6 as-is, or do they depend on patches 2/6 and 3/6 ?

Thanks,
Guenter

I think patch 5/6 only makes sense with patch 2/6. If we do not set the tacho evaluation parameters, clearing the fan fault irq has no effect...

- Nuno Sá

author maintainer
#4 lore raw

RFC PATCH 2/6 hwmon: axi-fan-control: add tacho devicetree properties

In reply to Nuno Sá

This core is capable to run without any user interaction and when it does, it uses some predefined values in order to evaluate the tacho signal from the FAN. These values depend on the attached FAN, so that the core now exposes registers to change them accordingly. The values are:

* adi,tacho-25-us: Expected tacho signal when the PWM is 25%;
* adi,tacho-50-us: Expected tacho signal when the PWM is 50%;
* adi,tacho-75-us: Expected tacho signal when the PWM is 75%;
* adi,tacho-100-us: Expected tacho signal when the PWM is 100%.

---
 drivers/hwmon/axi-fan-control.c | 34 +++++++++++++++++++++++++++++++++
 1 file changed, 34 insertions(+)
drivers/hwmon/axi-fan-control.c +34 -0
index 901d1588234d..aa5a922f684d 100644
@@ -23,6 +23,14 @@
 #define ADI_REG_PWM_PERIOD	0x00c0
 #define ADI_REG_TACH_MEASUR	0x00c4
 #define ADI_REG_TEMPERATURE	0x00c8
+#define ADI_REG_TACH_25		0x0140
+#define ADI_REG_TACH_50		0x0144
+#define ADI_REG_TACH_75		0x0148
+#define ADI_REG_TACH_100	0x014c
+#define ADI_REG_TACH_25_TOL	0x0150
+#define ADI_REG_TACH_50_TOL	0x0154
+#define ADI_REG_TACH_75_TOL	0x0158
+#define ADI_REG_TACH_100_TOL	0x015c
 
 #define ADI_REG_IRQ_MASK	0x0040
 #define ADI_REG_IRQ_PENDING	0x0044
@@ -328,6 +336,7 @@ static int axi_fan_control_init(struct axi_fan_control_data *ctl,
 				const struct device_node *np)
 {
 	int ret;
+	u32 tacho_val;
 
 	/* get fan pulses per revolution */
 	ret = of_property_read_u32(np, "pulses-per-revolution", &ctl->ppr);
@@ -337,6 +346,31 @@ static int axi_fan_control_init(struct axi_fan_control_data *ctl,
 	/* 1, 2 and 4 are the typical and accepted values */
 	if (ctl->ppr != 1 && ctl->ppr != 2 && ctl->ppr != 4)
 		return -EINVAL;
+
+	if (!of_property_read_u32(np, "adi,tacho-25-us", &tacho_val)) {
+		tacho_val = DIV_ROUND_CLOSEST_ULL((u64)tacho_val * ctl->clk_rate, 1000000);
+		axi_iowrite(tacho_val, ADI_REG_TACH_25, ctl);
+		axi_iowrite(DIV_ROUND_CLOSEST(tacho_val * 25, 100), ADI_REG_TACH_25_TOL, ctl);
+	}
+
+	if (!of_property_read_u32(np, "adi,tacho-50-us", &tacho_val)) {
+		tacho_val = DIV_ROUND_CLOSEST_ULL((u64)tacho_val * ctl->clk_rate, 1000000);
+		axi_iowrite(tacho_val, ADI_REG_TACH_50, ctl);
+		axi_iowrite(DIV_ROUND_CLOSEST(tacho_val * 25, 100), ADI_REG_TACH_50_TOL, ctl);
+	}
+
+	if (!of_property_read_u32(np, "adi,tacho-75-us", &tacho_val)) {
+		tacho_val = DIV_ROUND_CLOSEST_ULL((u64)tacho_val * ctl->clk_rate, 1000000);
+		axi_iowrite(tacho_val, ADI_REG_TACH_75, ctl);
+		axi_iowrite(DIV_ROUND_CLOSEST(tacho_val * 25, 100), ADI_REG_TACH_75_TOL, ctl);
+	}
+
+	if (!of_property_read_u32(np, "adi,tacho-100-us", &tacho_val)) {
+		tacho_val = DIV_ROUND_CLOSEST_ULL((u64)tacho_val * ctl->clk_rate, 1000000);
+		axi_iowrite(tacho_val, ADI_REG_TACH_100, ctl);
+		axi_iowrite(DIV_ROUND_CLOSEST(tacho_val * 25, 100), ADI_REG_TACH_100_TOL, ctl);
+	}
+
 	/*
 	 * Enable all IRQs
 	 */
Signature · 1 line
2.32.0
author maintainer
#5 lore raw

RFC PATCH 3/6 dt-bindings: axi-fan-control: add tacho properties

In reply to Nuno Sá

Add the bindings for the tacho signal evaluation parameters which depend on the FAN being used.

---
 .../bindings/hwmon/adi,axi-fan-control.yaml          | 12 ++++++++++++
 1 file changed, 12 insertions(+)
Documentation/devicetree/bindings/hwmon/adi,axi-fan-control.yaml +12 -0
index 6747b870f297..0481eb34d9f1 100644
@@ -37,6 +37,18 @@ properties:
     $ref: /schemas/types.yaml#/definitions/uint32
     enum: [1, 2, 4]
 
+  adi,tacho-25-us:
+    description: Expected tacho signal when the PWM is at 25%.
+
+  adi,tacho-50-us:
+    description: Expected tacho signal when the PWM is at 50%.
+
+  adi,tacho-75-us:
+    description: Expected tacho signal when the PWM is at 75%.
+
+  adi,tacho-100-us:
+    description: Expected tacho signal when the PWM is at 100%.
+
 required:
   - compatible
   - reg
Signature · 1 line
2.32.0
maintainer
#6 lore raw

Re: [RFC PATCH 3/6] dt-bindings: axi-fan-control: add tacho properties

Quoted 17 lines · Nuno Sá

Add the bindings for the tacho signal evaluation parameters which depend on the FAN being used.

---
 .../bindings/hwmon/adi,axi-fan-control.yaml          | 12 ++++++++++++
 1 file changed, 12 insertions(+)
Documentation/devicetree/bindings/hwmon/adi,axi-fan-control.yaml +1 -0
index 6747b870f297..0481eb34d9f1 100644
@@ -37,6 +37,18 @@ properties:
     $ref: /schemas/types.yaml#/definitions/uint32
     enum: [1, 2, 4]
 
+  adi,tacho-25-us:

Documentation/devicetree/bindings/hwmon/adi,axi-fan-control.yaml properties: · line 50

Quoted 10 lines
Documentation/devicetree/bindings/hwmon/adi,axi-fan-control.yaml +10 -0
+    description: Expected tacho signal when the PWM is at 25%.
+
+  adi,tacho-50-us:
+    description: Expected tacho signal when the PWM is at 50%.
+
+  adi,tacho-75-us:
+    description: Expected tacho signal when the PWM is at 75%.
+
+  adi,tacho-100-us:
+    description: Expected tacho signal when the PWM is at 100%.

This looks like it should be common. But having PWM percents in the property names doesn't scale. This is also a property of the fan, not the fan controller.

There's only so many ways a fan can be controlled and I'm going to keep telling folks to make a common fan binding. There's some start to it, but it needs some work.

Rob

author maintainer
#7 lore raw

RE: [RFC PATCH 3/6] dt-bindings: axi-fan-control: add tacho properties

Quoted 34 lines

From: Rob Herring <[email protected]>
Sent: Monday, July 12, 2021 7:27 PM
To: Sa, Nuno <[email protected]>
Cc: [email protected]; [email protected]; Guenter Roeck <[email protected]>; Jean Delvare <[email protected]>
Subject: Re: [RFC PATCH 3/6] dt-bindings: axi-fan-control: add tacho properties

[External]

Quoted 1 line · Nuno Sá

Add the bindings for the tacho signal evaluation parameters which

depend

Quoted 5 lines

on the FAN being used.

---
 .../bindings/hwmon/adi,axi-fan-control.yaml          | 12

++++++++++++

Review

Quoted 3 lines
 1 file changed, 12 insertions(+)
(quoted diff) +0 -0

control.yaml b/Documentation/devicetree/bindings/hwmon/adi,axi- fan-control.yaml

Quoted 2 lines

index 6747b870f297..0481eb34d9f1 100644
--- a/Documentation/devicetree/bindings/hwmon/adi,axi-fan-

control.yaml

Quoted 1 line

+++ b/Documentation/devicetree/bindings/hwmon/adi,axi-fan-

control.yaml

Quoted 4 lines
Documentation/devicetree/bindings/hwmon/adi,axi-fan-control.yaml +0 -0
@@ -37,6 +37,18 @@ properties:
     $ref: /schemas/types.yaml#/definitions/uint32
     enum: [1, 2, 4]
 
Quoted 15 lines

Documentation/devicetree/bindings/hwmon/adi,axi-fan-control.yaml properties: · line 50

Quoted 11 lines
Documentation/devicetree/bindings/hwmon/adi,axi-fan-control.yaml +11 -0
+  adi,tacho-25-us:
+    description: Expected tacho signal when the PWM is at 25%.
+
+  adi,tacho-50-us:
+    description: Expected tacho signal when the PWM is at 50%.
+
+  adi,tacho-75-us:
+    description: Expected tacho signal when the PWM is at 75%.
+
+  adi,tacho-100-us:
+    description: Expected tacho signal when the PWM is at 100%.

This looks like it should be common. But having PWM percents in the property names doesn't scale. This is also a property of the fan, not the fan controller.

Yes, I see that these parameters are definitely a property of the attached fan but the evaluation of these timings are very specific to this controller (I think). The way it works is that the HW can fully operate without any runtime SW configuration. In this case, it will use the values in these registers to evaluate the tacho signal coming from the FAN. And the HW really uses the evaluation points like this (0, 25%, 50% and 100%). It has some predefined values that work for the FAN that was used to develop the IP but naturally the evaluation will fail as soon as other FAN is attached (resulting in fan fault interrupts). And yes, writing these parameters is already SW configuration but what I mean with "runtime" is after probe :).

So, I honestly do not know how we could name this better... Maybe a 'tacho-eval-points-us' array? The question would be the min/max elements? Do you have any suggestion for a more generic property?

Quoted 4 lines

There's only so many ways a fan can be controlled and I'm going to keep
telling folks to make a common fan binding. There's some start to it, but it needs some work.

You mean the pwm-fan.txt? I gave a look to the driver and I don't think it fully fits this controller. I'm ok in sending an fan.yaml binding if you prefer it but I'm just not sure what we would need there... Maybe pulses-per-revolution and the above property
(whatever the decided name) would be a starting point?

- Nuno Sá

maintainer
#8 lore raw

Re: [RFC PATCH 3/6] dt-bindings: axi-fan-control: add tacho properties

Quoted 50 lines · Nuno
Quoted 34 lines

From: Rob Herring <[email protected]>
Sent: Monday, July 12, 2021 7:27 PM
To: Sa, Nuno <[email protected]>
Cc: [email protected]; [email protected]; Guenter Roeck <[email protected]>; Jean Delvare <[email protected]>
Subject: Re: [RFC PATCH 3/6] dt-bindings: axi-fan-control: add tacho properties

[External]

Quoted 1 line · Nuno Sá

Add the bindings for the tacho signal evaluation parameters which

depend

Quoted 5 lines

on the FAN being used.

---
 .../bindings/hwmon/adi,axi-fan-control.yaml          | 12

++++++++++++

Review

Quoted 3 lines
 1 file changed, 12 insertions(+)
(quoted diff) +0 -0

control.yaml b/Documentation/devicetree/bindings/hwmon/adi,axi- fan-control.yaml

Quoted 2 lines

index 6747b870f297..0481eb34d9f1 100644
--- a/Documentation/devicetree/bindings/hwmon/adi,axi-fan-

control.yaml

Quoted 1 line

+++ b/Documentation/devicetree/bindings/hwmon/adi,axi-fan-

control.yaml

Quoted 4 lines
Documentation/devicetree/bindings/hwmon/adi,axi-fan-control.yaml +0 -0
@@ -37,6 +37,18 @@ properties:
     $ref: /schemas/types.yaml#/definitions/uint32
     enum: [1, 2, 4]
 
Quoted 15 lines

Documentation/devicetree/bindings/hwmon/adi,axi-fan-control.yaml properties: · line 50

Quoted 11 lines
Documentation/devicetree/bindings/hwmon/adi,axi-fan-control.yaml +11 -0
+  adi,tacho-25-us:
+    description: Expected tacho signal when the PWM is at 25%.
+
+  adi,tacho-50-us:
+    description: Expected tacho signal when the PWM is at 50%.
+
+  adi,tacho-75-us:
+    description: Expected tacho signal when the PWM is at 75%.
+
+  adi,tacho-100-us:
+    description: Expected tacho signal when the PWM is at 100%.

This looks like it should be common. But having PWM percents in the property names doesn't scale. This is also a property of the fan, not the fan controller.

Quoted 11 lines

Yes, I see that these parameters are definitely a property of the attached fan but the evaluation of these timings are very specific to this controller (I think). The way it works is that the HW can fully operate without any runtime SW configuration. In this case, it will use the values in these registers to evaluate the tacho signal coming from the FAN. And the HW really uses the evaluation points like this (0, 25%, 50% and 100%). It has some predefined values that work for the FAN that was used to develop the IP but naturally the evaluation will fail as soon as other FAN is attached (resulting in fan fault interrupts). And yes, writing these parameters is already SW configuration but what I mean with "runtime" is after probe :).

Are you sure you can ever get this stable ? Each fan has its own properties and tolerances. If you replace a fan in a given system, you might get different RPM numbers. The RPM will differ widely from system to system and from fan to fan. Anything that assumes a specific RPM in devicetree data seems to be quite vulnerable to failures. I have experienced that recently with a different chip which also tries to correlate RPM and PWM and fails quite miserably.

In my experience, anything other than minimum fan speed is really a recipe for instability and sporadic false failures. Even setting a minimum fan speed is tricky because it depends a lot on the fan.

Quoted 4 lines

So, I honestly do not know how we could name this better... Maybe a 'tacho-eval-points-us' array? The question would be the min/max elements? Do you have any suggestion for a more generic property?

I am guessing that the "us" refers to the time between pulses from the fan. I think this is a bad value to start with - anything fan speed related should really be expressed in RPM, not in time between pulses.

Overall I don't think this should be handled as generic set of properties. Whatever we come up with as standard set of pwm or fan related properties should not be an expected correlation between pwm and rpm. Assuming such a property is needed here (after all, the controller is what it is), maybe a set of tuples makes sense, such as

	adi,pwm-rpm-map = <
		25, 250,
		50, 500,
		75, 750,
		100, 1000
	>;

though I think that each of those should also include the tolerance instead of just assuming that a 25% tolerance (as implemented in patch 2/6) would work for all fans.

Guenter

Quoted 12 lines
Quoted 4 lines

There's only so many ways a fan can be controlled and I'm going to keep
telling folks to make a common fan binding. There's some start to it, but it needs some work.

You mean the pwm-fan.txt? I gave a look to the driver and I don't think it fully fits this controller. I'm ok in sending an fan.yaml binding if you prefer it but I'm just not sure what we would need there... Maybe pulses-per-revolution and the above property
(whatever the decided name) would be a starting point?

- Nuno Sá

author maintainer
#9 lore raw

RE: [RFC PATCH 3/6] dt-bindings: axi-fan-control: add tacho properties

Quoted 98 lines

From: Guenter Roeck <[email protected]> On Behalf Of Guenter Roeck
Sent: Thursday, July 15, 2021 10:40 PM
To: Sa, Nuno <[email protected]>
Cc: Rob Herring <[email protected]>; [email protected]; [email protected]; Jean Delvare <[email protected]>
Subject: Re: [RFC PATCH 3/6] dt-bindings: axi-fan-control: add tacho properties

Quoted 7 lines · Nuno
Quoted 7 lines

From: Rob Herring <[email protected]>
Sent: Monday, July 12, 2021 7:27 PM
To: Sa, Nuno <[email protected]>
Cc: [email protected]; [email protected]; Guenter Roeck <[email protected]>; Jean Delvare <[email protected]>
Subject: Re: [RFC PATCH 3/6] dt-bindings: axi-fan-control: add

tacho

Quoted 6 lines
Quoted 6 lines

properties

[External]

Quoted 1 line · Nuno Sá

Add the bindings for the tacho signal evaluation parameters

which

Quoted 10 lines
Quoted 10 lines

depend

Quoted 5 lines

on the FAN being used.

---
 .../bindings/hwmon/adi,axi-fan-control.yaml          | 12

++++++++++++

Review

Quoted 3 lines
 1 file changed, 12 insertions(+)
(quoted diff) +0 -0

fan-

Quoted 1 line
Quoted 1 line

control.yaml

b/Documentation/devicetree/bindings/hwmon/adi,axi-

Quoted 10 lines
Quoted 10 lines

fan-control.yaml

Quoted 2 lines

index 6747b870f297..0481eb34d9f1 100644
--- a/Documentation/devicetree/bindings/hwmon/adi,axi-fan-

control.yaml

Quoted 1 line

+++ b/Documentation/devicetree/bindings/hwmon/adi,axi-fan-

control.yaml

Quoted 4 lines
Documentation/devicetree/bindings/hwmon/adi,axi-fan-control.yaml +0 -0
@@ -37,6 +37,18 @@ properties:
     $ref: /schemas/types.yaml#/definitions/uint32
     enum: [1, 2, 4]
 
Quoted 13 lines
Quoted 5 lines
Quoted 5 lines
Documentation/devicetree/bindings/hwmon/adi,axi-fan-control.yaml +5 -0
+  adi,tacho-25-us:
+    description: Expected tacho signal when the PWM is at 25%.
+
+  adi,tacho-50-us:
+    description: Expected tacho signal when the PWM is at 50%.
Quoted 8 lines

Documentation/devicetree/bindings/hwmon/adi,axi-fan-control.yaml properties: · line 50

Quoted 6 lines
Documentation/devicetree/bindings/hwmon/adi,axi-fan-control.yaml +6 -0
+
+  adi,tacho-75-us:
+    description: Expected tacho signal when the PWM is at 75%.
+
+  adi,tacho-100-us:
+    description: Expected tacho signal when the PWM is at 100%.

This looks like it should be common. But having PWM percents in

the

Quoted 4 lines
Quoted 2 lines

property names doesn't scale. This is also a property of the fan, not the fan controller.

Yes, I see that these parameters are definitely a property of the

attached

Quoted 1 line

fan but the evaluation of these timings are very specific to this

controller

Quoted 1 line

(I think). The way it works is that the HW can fully operate without

any

Quoted 2 lines

runtime SW configuration. In this case, it will use the values in these registers to evaluate the tacho signal coming from the FAN. And the

HW

Quoted 1 line

really uses the evaluation points like this (0, 25%, 50% and 100%). It

has

Quoted 1 line

some predefined values that work for the FAN that was used to

develop

Quoted 1 line

the IP but naturally the evaluation will fail as soon as other FAN is

attached

Quoted 1 line

(resulting in fan fault interrupts). And yes, writing these parameters

is

Quoted 1 line

already SW configuration but what I mean with "runtime" is after

probe :).

Quoted 1 line

Are you sure you can ever get this stable ? Each fan has its own properties
and tolerances. If you replace a fan in a given system, you might get different RPM numbers. The RPM will differ widely from system to system
and from fan to fan. Anything that assumes a specific RPM in devicetree
data seems to be quite vulnerable to failures. I have experienced that recently with a different chip which also tries to correlate RPM and PWM
and fails quite miserably.

Quoted 5 lines

In my experience, anything other than minimum fan speed is really a recipe
for instability and sporadic false failures. Even setting a minimum fan speed
is tricky because it depends a lot on the fan.

I see what you mean. So, I had to go through this process when testing this changes because the fan I'm using is different from the default one used to develop and stablish the default values in the IP core. The core provides you with a register which contains the tacho measurements in clock cycles. You can read that for all the PWM points of interest (with devmem2 for example) and make your own "calibration". I assume that people have to go through this process before putting some values in the devicetree. I'm aware this is not the neatest process but I guess it's acceptable...

Quoted 26 lines
Quoted 1 line

So, I honestly do not know how we could name this better... Maybe

a

Quoted 3 lines

'tacho-eval-points-us' array? The question would be the min/max elements? Do you have any suggestion for a more generic property?

I am guessing that the "us" refers to the time between pulses from the fan. I think this is a bad value to start with - anything fan speed related should really be expressed in RPM, not in time between pulses.

Overall I don't think this should be handled as generic set of properties.
Whatever we come up with as standard set of pwm or fan related properties
should not be an expected correlation between pwm and rpm. Assuming such
a property is needed here (after all, the controller is what it is), maybe a set of tuples makes sense, such as

	adi,pwm-rpm-map = <
		25, 250,
		50, 500,
		75, 750,
		100, 1000
	>;
Quoted 3 lines

though I think that each of those should also include the tolerance instead of just assuming that a 25% tolerance (as implemented in patch 2/6) would work for all fans.

Yes, this makes sense thanks. As the HW default tolerance is 25% I was somehow attached to that. Since all these values are correlated it makes complete sense to also give the tolerance here as it makes things more flexible. The map is also a good tip, I just have to see if there is a nice way to specify that the pwm column is constant...

Thanks!
- Nuno Sá

maintainer
#10 lore raw

Re: [RFC PATCH 3/6] dt-bindings: axi-fan-control: add tacho properties

On 7/16/21 12:44 AM, Sa, Nuno wrote:
[ ... ]

Quoted 19 lines
Quoted 13 lines

Are you sure you can ever get this stable ? Each fan has its own properties
and tolerances. If you replace a fan in a given system, you might get different RPM numbers. The RPM will differ widely from system to system
and from fan to fan. Anything that assumes a specific RPM in devicetree
data seems to be quite vulnerable to failures. I have experienced that recently with a different chip which also tries to correlate RPM and PWM
and fails quite miserably.

Quoted 5 lines

In my experience, anything other than minimum fan speed is really a recipe
for instability and sporadic false failures. Even setting a minimum fan speed
is tricky because it depends a lot on the fan.

Quoted 3 lines

I see what you mean. So, I had to go through this process when testing this changes because the fan I'm using is different from the default one used to develop and stablish the default values in the IP core. The core

Exactly my point.

Quoted 7 lines

provides you with a register which contains the tacho measurements in clock cycles. You can read that for all the PWM points of interest (with devmem2 for example) and make your own "calibration". I assume that people have to go through this process before putting some values in the devicetree. I'm aware this is not the neatest process but I guess it's acceptable...

Do you really expect everyone using a system with this chip to go through this process and update its devicetree configuration, and then repeat it whenever a fan is changed ? Given how dynamic this is, I really wonder if that information should be in devicetree in the first place.

Guenter

author maintainer
#11 lore raw

RE: [RFC PATCH 3/6] dt-bindings: axi-fan-control: add tacho properties

Quoted 56 lines

-----Original Message-----
From: Guenter Roeck <[email protected]> On Behalf Of Guenter Roeck
Sent: Friday, July 16, 2021 5:04 PM
To: Sa, Nuno <[email protected]>
Cc: Rob Herring <[email protected]>; [email protected]; [email protected]; Jean Delvare <[email protected]>
Subject: Re: [RFC PATCH 3/6] dt-bindings: axi-fan-control: add tacho properties

[External]

On 7/16/21 12:44 AM, Sa, Nuno wrote:
[ ... ]

Quoted 9 lines
Quoted 9 lines

Are you sure you can ever get this stable ? Each fan has its own properties
and tolerances. If you replace a fan in a given system, you might get different RPM numbers. The RPM will differ widely from system to system
and from fan to fan. Anything that assumes a specific RPM in devicetree
data seems to be quite vulnerable to failures. I have experienced

that

Quoted 5 lines
Quoted 5 lines

recently with a different chip which also tries to correlate RPM and PWM
and fails quite miserably.

In my experience, anything other than minimum fan speed is really

a

Quoted 2 lines
Quoted 2 lines

recipe
for instability and sporadic false failures. Even setting a minimum

fan

Quoted 4 lines
Quoted 2 lines

speed
is tricky because it depends a lot on the fan.

I see what you mean. So, I had to go through this process when

testing

Quoted 1 line

this changes because the fan I'm using is different from the default

one

Quoted 1 line

used to develop and stablish the default values in the IP core. The

core

Exactly my point.

Quoted 1 line

provides you with a register which contains the tacho measurements

in

Quoted 2 lines

clock cycles. You can read that for all the PWM points of interest (with devmem2 for example) and make your own "calibration". I

assume

Quoted 1 line

that people have to go through this process before putting some

values

Quoted 1 line

in the devicetree. I'm aware this is not the neatest process but I

guess it's

Quoted 9 lines
Quoted 2 lines

acceptable...

Do you really expect everyone using a system with this chip to go through
this process and update its devicetree configuration, and then repeat it whenever a fan is changed ? Given how dynamic this is, I really wonder if that information should be in devicetree in the first place.

My naive assumption was that we would only do this work at evaluation time. After that and after we settled with a fan for some system, I expected that changing to a different fan is not that likely. From your inputs, I guess this is not really the case which makes this process more cumbersome (as it also implies recompiling the devicetree for your system).

However, even if we export these as runtime parameters, services/daemons will also have an hard time doing this "calibration" in a dynamic way. The reason is because the way the controller works is that it only accepts a new PWM request if it is an higher value than whatever the HW has at that moment. Thus, going through the calibration points might be very cumbersome. I can see some ways of handling this though but not very neat...

Since this is a FPGA core, we might have some flexibility here. Something that came to my mind would be to have a calibration mode in the HW that would allow us to freely control the PWM values. In that way we could go freely over the calibration points. I guess, for safety reasons, this calibration mode would expire after some reasonable time (that give us enough time for doing the whole thing). The best place for doing the calibration, I guess it would be directly in the driver since we do receive the interrupts about new tacho measurements making things easier to sync and handle. However, given the time that takes for a new PWM to settle + new tacho measurements, it would not be very acceptable to do this during probe which is definitely also not ideal (we could defer this to a worker/timer).

I'm not sure if the above makes much sense to you and it also depends on the HW guys being on board with this mechanism.

- Nuno Sá

maintainer
#12 lore raw

Re: [RFC PATCH 3/6] dt-bindings: axi-fan-control: add tacho properties

Quoted 90 lines · Nuno
Quoted 56 lines

-----Original Message-----
From: Guenter Roeck <[email protected]> On Behalf Of Guenter Roeck
Sent: Friday, July 16, 2021 5:04 PM
To: Sa, Nuno <[email protected]>
Cc: Rob Herring <[email protected]>; [email protected]; [email protected]; Jean Delvare <[email protected]>
Subject: Re: [RFC PATCH 3/6] dt-bindings: axi-fan-control: add tacho properties

[External]

On 7/16/21 12:44 AM, Sa, Nuno wrote:
[ ... ]

Quoted 9 lines
Quoted 9 lines

Are you sure you can ever get this stable ? Each fan has its own properties
and tolerances. If you replace a fan in a given system, you might get different RPM numbers. The RPM will differ widely from system to system
and from fan to fan. Anything that assumes a specific RPM in devicetree
data seems to be quite vulnerable to failures. I have experienced

that

Quoted 5 lines
Quoted 5 lines

recently with a different chip which also tries to correlate RPM and PWM
and fails quite miserably.

In my experience, anything other than minimum fan speed is really

a

Quoted 2 lines
Quoted 2 lines

recipe
for instability and sporadic false failures. Even setting a minimum

fan

Quoted 4 lines
Quoted 2 lines

speed
is tricky because it depends a lot on the fan.

I see what you mean. So, I had to go through this process when

testing

Quoted 1 line

this changes because the fan I'm using is different from the default

one

Quoted 1 line

used to develop and stablish the default values in the IP core. The

core

Exactly my point.

Quoted 1 line

provides you with a register which contains the tacho measurements

in

Quoted 2 lines

clock cycles. You can read that for all the PWM points of interest (with devmem2 for example) and make your own "calibration". I

assume

Quoted 1 line

that people have to go through this process before putting some

values

Quoted 1 line

in the devicetree. I'm aware this is not the neatest process but I

guess it's

Quoted 9 lines
Quoted 2 lines

acceptable...

Do you really expect everyone using a system with this chip to go through
this process and update its devicetree configuration, and then repeat it whenever a fan is changed ? Given how dynamic this is, I really wonder if that information should be in devicetree in the first place.

My naive assumption was that we would only do this work at evaluation time. After that and after we settled with a fan for some system, I expected that changing to a different fan is not that likely. From your inputs, I guess this is not really the case which makes this process more cumbersome (as it also implies recompiling the devicetree for your system).

However, even if we export these as runtime parameters, services/daemons will also have an hard time doing this "calibration" in a dynamic way. The reason is because the way the controller works is that it only accepts a new PWM request if it is an higher value than whatever the HW has at that moment. Thus, going through the calibration points might be very cumbersome. I can see some ways of handling this though but not very neat...

Since this is a FPGA core, we might have some flexibility here. Something that came to my mind would be to have a calibration mode in the HW that would allow us to freely control the PWM values. In that way we could go freely over the calibration points. I guess, for safety reasons, this calibration mode would expire after some reasonable time (that give us enough time for doing the whole thing). The best place for doing the calibration, I guess it would be directly in the driver since we do receive the interrupts about new tacho measurements making things easier to sync and handle. However, given the time that takes for a new PWM to settle + new tacho measurements, it would not be very acceptable to do this during probe which is definitely also not ideal (we could defer this to a worker/timer).

Quoted 3 lines

I'm not sure if the above makes much sense to you and it also depends on the HW guys being on board with this mechanism.

I don't really know what to say or recommend here. Personally I think any attempt to tie PWM values to RPM are doomed to fail. Here are a couple of examples:

Take your test system and move the fan to a restricted place (eg close to a wall). You'll see the fan RPM change, potentially significantly. Put it into some place with airflow towards or away from the system (eg blow air into the system from another place, which may happen if the system is installed in a lab), and again you'll see fan speed changes. Open the chassis, and the fan speed will change. I have seen fan speeds vary by up to 50% when changing airflow.

That doesn't even take into account that replacing a fan even with a similar model (eg after a fan failed) will likely result in potentially significant rpm changes.

Ultimately, anything that does more than determine if a fan is still running is potentially unstable.

Having said all that, it is really your call to decide how you want to detect fan failures.

Thanks,
Guenter

author maintainer
#13 lore raw

RE: [RFC PATCH 3/6] dt-bindings: axi-fan-control: add tacho properties

Quoted 145 lines

From: Guenter Roeck <[email protected]> On Behalf Of Guenter Roeck
Sent: Wednesday, July 21, 2021 5:00 PM
To: Sa, Nuno <[email protected]>
Cc: Rob Herring <[email protected]>; [email protected]; [email protected]; Jean Delvare <[email protected]>
Subject: Re: [RFC PATCH 3/6] dt-bindings: axi-fan-control: add tacho properties

Quoted 8 lines · Nuno
Quoted 8 lines

-----Original Message-----
From: Guenter Roeck <[email protected]> On Behalf Of Guenter Roeck
Sent: Friday, July 16, 2021 5:04 PM
To: Sa, Nuno <[email protected]>
Cc: Rob Herring <[email protected]>; linux-

[email protected];

Quoted 2 lines
Quoted 2 lines

[email protected]; Jean Delvare <[email protected]>
Subject: Re: [RFC PATCH 3/6] dt-bindings: axi-fan-control: add

tacho

Quoted 10 lines
Quoted 10 lines

properties

[External]

On 7/16/21 12:44 AM, Sa, Nuno wrote:
[ ... ]

Quoted 4 lines
Quoted 4 lines

Are you sure you can ever get this stable ? Each fan has its own properties
and tolerances. If you replace a fan in a given system, you might

get

Quoted 1 line
Quoted 1 line
Quoted 1 line
Quoted 1 line

different RPM numbers. The RPM will differ widely from system

to

Quoted 4 lines
Quoted 4 lines
Quoted 4 lines
Quoted 4 lines

system
and from fan to fan. Anything that assumes a specific RPM in devicetree
data seems to be quite vulnerable to failures. I have

experienced

Quoted 2 lines
Quoted 2 lines

that

Quoted 1 line
Quoted 1 line

recently with a different chip which also tries to correlate RPM

and

Quoted 4 lines
Quoted 4 lines
Quoted 4 lines
Quoted 4 lines

PWM
and fails quite miserably.

In my experience, anything other than minimum fan speed is

really

Quoted 3 lines
Quoted 3 lines

a

Quoted 2 lines
Quoted 2 lines

recipe
for instability and sporadic false failures. Even setting a

minimum

Quoted 7 lines
Quoted 7 lines

fan

Quoted 4 lines
Quoted 2 lines

speed
is tricky because it depends a lot on the fan.

I see what you mean. So, I had to go through this process when

testing

Quoted 1 line

this changes because the fan I'm using is different from the

default

Quoted 2 lines
Quoted 2 lines

one

Quoted 1 line

used to develop and stablish the default values in the IP core.

The

Quoted 5 lines
Quoted 5 lines

core

Exactly my point.

Quoted 1 line

provides you with a register which contains the tacho

measurements

Quoted 6 lines
Quoted 6 lines

in

Quoted 2 lines

clock cycles. You can read that for all the PWM points of interest (with devmem2 for example) and make your own "calibration". I

assume

Quoted 1 line

that people have to go through this process before putting some

values

Quoted 8 lines
Quoted 8 lines
Quoted 1 line

in the devicetree. I'm aware this is not the neatest process but I

guess it's

Quoted 2 lines

acceptable...

Do you really expect everyone using a system with this chip to go through
this process and update its devicetree configuration, and then

repeat it

Quoted 1 line
Quoted 1 line

whenever a fan is changed ? Given how dynamic this is, I really

wonder

Quoted 4 lines
Quoted 2 lines

if that information should be in devicetree in the first place.

My naive assumption was that we would only do this work at

evaluation

Quoted 1 line

time. After that and after we settled with a fan for some system, I

expected

Quoted 1 line

that changing to a different fan is not that likely. From your inputs, I

guess

Quoted 1 line

this is not really the case which makes this process more

cumbersome (as it

Quoted 3 lines

also implies recompiling the devicetree for your system).

However, even if we export these as runtime parameters,

services/daemons

Quoted 1 line

will also have an hard time doing this "calibration" in a dynamic way.

The reason

Quoted 1 line

is because the way the controller works is that it only accepts a new

PWM

Quoted 1 line

request if it is an higher value than whatever the HW has at that

moment. Thus,

Quoted 1 line

going through the calibration points might be very cumbersome. I

can see some

Quoted 3 lines

ways of handling this though but not very neat...

Since this is a FPGA core, we might have some flexibility here.

Something that

Quoted 1 line

came to my mind would be to have a calibration mode in the HW that

would

Quoted 1 line

allow us to freely control the PWM values. In that way we could go

freely over

Quoted 1 line

the calibration points. I guess, for safety reasons, this calibration

mode would

Quoted 1 line

expire after some reasonable time (that give us enough time for

doing the whole

Quoted 1 line

thing). The best place for doing the calibration, I guess it would be

directly in the

Quoted 1 line

driver since we do receive the interrupts about new tacho

measurements making

Quoted 1 line

things easier to sync and handle. However, given the time that takes

for a new

Quoted 1 line

PWM to settle + new tacho measurements, it would not be very

acceptable to do this

Quoted 1 line

during probe which is definitely also not ideal (we could defer this to

a worker/timer).

Quoted 2 lines

I'm not sure if the above makes much sense to you and it also

depends on the HW

Quoted 2 lines

guys being on board with this mechanism.

I don't really know what to say or recommend here. Personally I think any
attempt to tie PWM values to RPM are doomed to fail. Here are a couple of
examples:

Quoted 11 lines

Take your test system and move the fan to a restricted place (eg close to a
wall). You'll see the fan RPM change, potentially significantly. Put it into some place with airflow towards or away from the system (eg blow air into
the system from another place, which may happen if the system is installed
in a lab), and again you'll see fan speed changes. Open the chassis, and the fan speed will change. I have seen fan speeds vary by up to 50% when
changing airflow.

Here we can at least control the tolerance for each PWM vs RPM point but I can image this as a very painful process to get these values right and no one will think in setting tolerances of 50%...

Quoted 8 lines

That doesn't even take into account that replacing a fan even with a similar
model (eg after a fan failed) will likely result in potentially significant rpm changes.

Ultimately, anything that does more than determine if a fan is still running
is potentially unstable.

Yeah, I understand your points. The HW does the evaluation and of course it also looks for the presence of a signal... So, in your opinion, not even setting a minimum fan speed is likely to be stable?

Quoted 4 lines

Having said all that, it is really your call to decide how you want to detect
fan failures.

Well, my hands are also tied here. The core is supposed to work without any SW interaction in which case the tacho evaluation is always done. The only thing I could do is to completely ignore fan faults which is also bad...

I can try to persuade the HW guy to completely remove the evaluation and just give fan fauts in case there's no signal but I'm not really sure he will go for it. In that case, I'm tempted to just leave this as-is (with the extra bindings for the tolerance and turn these bindings into a map) if you're willing to take it... The reason is that, as you said, this is likely to be unstable any ways so that the added complexity in the SW does not really pay off (better keep at least the SW simple)...

- Nuno Sá

maintainer
#14 lore raw

Re: [RFC PATCH 3/6] dt-bindings: axi-fan-control: add tacho properties

On 7/22/21 6:00 AM, Sa, Nuno wrote:
[ ... ]

Quoted 27 lines
Quoted 6 lines

I don't really know what to say or recommend here. Personally I think any
attempt to tie PWM values to RPM are doomed to fail. Here are a couple of
examples:

Quoted 11 lines

Take your test system and move the fan to a restricted place (eg close to a
wall). You'll see the fan RPM change, potentially significantly. Put it into some place with airflow towards or away from the system (eg blow air into
the system from another place, which may happen if the system is installed
in a lab), and again you'll see fan speed changes. Open the chassis, and the fan speed will change. I have seen fan speeds vary by up to 50% when
changing airflow.

Here we can at least control the tolerance for each PWM vs RPM point but I can image this as a very painful process to get these values right and no one will think in setting tolerances of 50%...

Quoted 5 lines

That doesn't even take into account that replacing a fan even with a similar
model (eg after a fan failed) will likely result in potentially significant rpm changes.

Quoted 8 lines
Quoted 3 lines

Ultimately, anything that does more than determine if a fan is still running
is potentially unstable.

Yeah, I understand your points. The HW does the evaluation and of course it also looks for the presence of a signal... So, in your opinion, not even setting a minimum fan speed is likely to be stable?

Using the minimum fan speed as detection mechanism for fan failures is ok and widely used. My concern is the desire to associate it with pwm values.

Quoted 9 lines
Quoted 4 lines

Having said all that, it is really your call to decide how you want to detect
fan failures.

Well, my hands are also tied here. The core is supposed to work without any SW interaction in which case the tacho evaluation is always done. The only thing I could do is to completely ignore fan faults which is also bad...

As I said above, it would be perfectly fine to have a parameter that reflects minimum fan speed (or, translated into chip speak, minimum number of pulses per minute).

Quoted 8 lines

I can try to persuade the HW guy to completely remove the evaluation and just give fan fauts in case there's no signal but I'm not really sure he will go for it. In that case, I'm tempted to just leave this as-is (with the extra bindings for the tolerance and turn these bindings into a map) if you're willing to take it... The reason is that, as you said, this is likely to be unstable any ways so that the added complexity in the SW does not really pay off (better keep at least the SW simple)...

Sure, I'll take it, as long as you find a binding that is acceptable for Rob. It is your funeral, after all :-).

Thanks,
Guenter

author maintainer
#15 lore raw

RFC PATCH 4/6 hwmon: axi-fan-control: handle irqs in natural order

In reply to Nuno Sá

The core will now start out of reset at boot as soon as clocking is available. Hence, by the time we unmask the interrupts we already might have some of them set. Thus, it's important to handle them in the natural order the core generates them. Otherwise, we could process 'ADI_IRQ_SRC_PWM_CHANGED' before 'ADI_IRQ_SRC_TEMP_INCREASE' and erroneously set 'update_tacho_params' to true.

---
 drivers/hwmon/axi-fan-control.c | 30 +++++++++++++++---------------
 1 file changed, 15 insertions(+), 15 deletions(-)
drivers/hwmon/axi-fan-control.c +15 -15
index aa5a922f684d..d4b62d54375b 100644
@@ -291,18 +291,9 @@ static irqreturn_t axi_fan_control_irq_handler(int irq, void *data)
 	u32 irq_pending = axi_ioread(ADI_REG_IRQ_PENDING, ctl);
 	u32 clear_mask;
 
-	if (irq_pending & ADI_IRQ_SRC_NEW_MEASUR) {
-		if (ctl->update_tacho_params) {
-			u32 new_tach = axi_ioread(ADI_REG_TACH_MEASUR, ctl);
-
-			/* get 25% tolerance */
-			u32 tach_tol = DIV_ROUND_CLOSEST(new_tach * 25, 100);
-			/* set new tacho parameters */
-			axi_iowrite(new_tach, ADI_REG_TACH_PERIOD, ctl);
-			axi_iowrite(tach_tol, ADI_REG_TACH_TOLERANCE, ctl);
-			ctl->update_tacho_params = false;
-		}
-	}
+	if (irq_pending & ADI_IRQ_SRC_TEMP_INCREASE)
+		/* hardware requested a new pwm */
+		ctl->hw_pwm_req = true;
 
 	if (irq_pending & ADI_IRQ_SRC_PWM_CHANGED) {
 		/*
@@ -318,9 +309,18 @@ static irqreturn_t axi_fan_control_irq_handler(int irq, void *data)
 		}
 	}
 
-	if (irq_pending & ADI_IRQ_SRC_TEMP_INCREASE)
-		/* hardware requested a new pwm */
-		ctl->hw_pwm_req = true;
+	if (irq_pending & ADI_IRQ_SRC_NEW_MEASUR) {
+		if (ctl->update_tacho_params) {
+			u32 new_tach = axi_ioread(ADI_REG_TACH_MEASUR, ctl);
+			/* get 25% tolerance */
+			u32 tach_tol = DIV_ROUND_CLOSEST(new_tach * 25, 100);
+
+			/* set new tacho parameters */
+			axi_iowrite(new_tach, ADI_REG_TACH_PERIOD, ctl);
+			axi_iowrite(tach_tol, ADI_REG_TACH_TOLERANCE, ctl);
+			ctl->update_tacho_params = false;
+		}
+	}
 
 	if (irq_pending & ADI_IRQ_SRC_TACH_ERR)
 		ctl->fan_fault = 1;
Signature · 1 line
2.32.0
author maintainer
#16 lore raw

RFC PATCH 5/6 hwmon: axi-fan-control: clear the fan fault irq at startup

In reply to Nuno Sá

The core might pull itself out of reset automatically which means it can run with invalid tacho evaluation parameters for some time. Thus, it will trigger a FAN FAULT interrupt as soon as we unmask it. Some userland apps might be sensitive to this and act drastically. Hence, we will clear it here and if there's something really wrong with the FAN or the evaluation parameters, we'll get that interrupt again...

---
 drivers/hwmon/axi-fan-control.c | 9 +++++++++
 1 file changed, 9 insertions(+)
drivers/hwmon/axi-fan-control.c +9 -0
index d4b62d54375b..59c9babb3850 100644
@@ -379,6 +379,15 @@ static int axi_fan_control_init(struct axi_fan_control_data *ctl,
 		      ADI_IRQ_SRC_PWM_CHANGED | ADI_IRQ_SRC_TEMP_INCREASE),
 		    ADI_REG_IRQ_MASK, ctl);
 
+	/*
+	 * The core might pull itself out of reset automatically which means it can run with
+	 * invalid tacho evaluation parameters for some time. Thus, it will trigger a FAN
+	 * FAULT interrupt as soon as we unmask it(and some userland apps might be sensitive to
+	 * this). Hence, we will clear it here and if there's something really wrong with the
+	 * FAN or the evaluation parameters, we'll get that interrupt again...
+	 */
+	axi_iowrite(ADI_IRQ_SRC_TACH_ERR, ADI_REG_IRQ_PENDING, ctl);
+
 	/* bring the device out of reset */
 	axi_iowrite(0x01, ADI_REG_RSTN, ctl);
 
Signature · 1 line
2.32.0
author maintainer
#17 lore raw

RFC PATCH 6/6 hwmon: axi-fan-control: support temperature vs pwm points

In reply to Nuno Sá

The HW has some predefined points where it will associate a PWM value. However some users might want to better set these points to their usecases. This patch exposes these points as pwm auto_points:

* pwm1_auto_point1_temp: temperature threshold below which PWM should be 0%;
* pwm1_auto_point2_temp: temperature threshold above which PWM should be 25%;
* pwm1_auto_point3_temp: temperature threshold below which PWM should be 25%;
* pwm1_auto_point4_temp: temperature threshold above which PWM should be 50%;
* pwm1_auto_point5_temp: temperature threshold below which PWM should be 50%;
* pwm1_auto_point6_temp: temperature threshold above which PWM should be 75%;
* pwm1_auto_point7_temp: temperature threshold below which PWM should be 75%;
* pwm1_auto_point8_temp: temperature threshold above which PWM should be 100%;

---
 drivers/hwmon/axi-fan-control.c | 74 ++++++++++++++++++++++++++++++++-
 1 file changed, 73 insertions(+), 1 deletion(-)
drivers/hwmon/axi-fan-control.c +73 -1
index 59c9babb3850..80b216448f47 100644
@@ -8,6 +8,7 @@
 #include <linux/clk.h>
 #include <linux/fpga/adi-axi-common.h>
 #include <linux/hwmon.h>
+#include <linux/hwmon-sysfs.h>
 #include <linux/interrupt.h>
 #include <linux/io.h>
 #include <linux/kernel.h>
@@ -31,6 +32,14 @@
 #define ADI_REG_TACH_50_TOL	0x0154
 #define ADI_REG_TACH_75_TOL	0x0158
 #define ADI_REG_TACH_100_TOL	0x015c
+#define ADI_REG_TEMP_00_H	0x0100
+#define ADI_REG_TEMP_25_L	0x0104
+#define ADI_REG_TEMP_25_H	0x0108
+#define ADI_REG_TEMP_50_L	0x010c
+#define ADI_REG_TEMP_50_H	0x0110
+#define ADI_REG_TEMP_75_L	0x0114
+#define ADI_REG_TEMP_75_H	0x0118
+#define ADI_REG_TEMP_100_L	0x011c
 
 #define ADI_REG_IRQ_MASK	0x0040
 #define ADI_REG_IRQ_PENDING	0x0044
@@ -70,6 +79,39 @@ static inline u32 axi_ioread(const u32 reg,
 	return ioread32(ctl->base + reg);
 }
 
+/*
+ * The core calculates the temperature as:
+ *	T = /raw * 509.3140064 / 65535) - 280.2308787
+ */
+static ssize_t axi_fan_control_show(struct device *dev, struct device_attribute *da, char *buf)
+{
+	struct axi_fan_control_data *ctl = dev_get_drvdata(dev);
+	struct sensor_device_attribute *attr = to_sensor_dev_attr(da);
+	u32 temp = axi_ioread(attr->index, ctl);
+
+	temp = DIV_ROUND_CLOSEST_ULL(temp * 509314ULL, 65535) - 280230;
+
+	return sprintf(buf, "%u\n", temp);
+}
+
+static ssize_t axi_fan_control_store(struct device *dev, struct device_attribute *da,
+				     const char *buf, size_t count)
+{
+	struct axi_fan_control_data *ctl = dev_get_drvdata(dev);
+	struct sensor_device_attribute *attr = to_sensor_dev_attr(da);
+	u32 temp;
+	int ret;
+
+	ret = kstrtou32(buf, 10, &temp);
+	if (ret)
+		return ret;
+
+	temp = DIV_ROUND_CLOSEST_ULL((temp + 280230) * 65535ULL, 509314);
+	axi_iowrite(temp, attr->index, ctl);
+
+	return count;
+}
+
 static long axi_fan_control_get_pwm_duty(const struct axi_fan_control_data *ctl)
 {
 	u32 pwm_width = axi_ioread(ADI_REG_PWM_WIDTH, ctl);
@@ -418,6 +460,36 @@ static const struct hwmon_chip_info axi_chip_info = {
 	.info = axi_fan_control_info,
 };
 
+/* temperature threshold below which PWM should be 0% */
+static SENSOR_DEVICE_ATTR_RW(pwm1_auto_point1_temp, axi_fan_control, ADI_REG_TEMP_00_H);
+/* temperature threshold above which PWM should be 25% */
+static SENSOR_DEVICE_ATTR_RW(pwm1_auto_point2_temp, axi_fan_control, ADI_REG_TEMP_25_L);
+/* temperature threshold below which PWM should be 25% */
+static SENSOR_DEVICE_ATTR_RW(pwm1_auto_point3_temp, axi_fan_control, ADI_REG_TEMP_25_H);
+/* temperature threshold above which PWM should be 50% */
+static SENSOR_DEVICE_ATTR_RW(pwm1_auto_point4_temp, axi_fan_control, ADI_REG_TEMP_50_L);
+/* temperature threshold below which PWM should be 50% */
+static SENSOR_DEVICE_ATTR_RW(pwm1_auto_point5_temp, axi_fan_control, ADI_REG_TEMP_50_H);
+/* temperature threshold above which PWM should be 75% */
+static SENSOR_DEVICE_ATTR_RW(pwm1_auto_point6_temp, axi_fan_control, ADI_REG_TEMP_75_L);
+/* temperature threshold below which PWM should be 75% */
+static SENSOR_DEVICE_ATTR_RW(pwm1_auto_point7_temp, axi_fan_control, ADI_REG_TEMP_75_H);
+/* temperature threshold above which PWM should be 100% */
+static SENSOR_DEVICE_ATTR_RW(pwm1_auto_point8_temp, axi_fan_control, ADI_REG_TEMP_100_L);
+
+static struct attribute *axi_fan_control_attrs[] = {
+	&sensor_dev_attr_pwm1_auto_point1_temp.dev_attr.attr,
+	&sensor_dev_attr_pwm1_auto_point2_temp.dev_attr.attr,
+	&sensor_dev_attr_pwm1_auto_point3_temp.dev_attr.attr,
+	&sensor_dev_attr_pwm1_auto_point4_temp.dev_attr.attr,
+	&sensor_dev_attr_pwm1_auto_point5_temp.dev_attr.attr,
+	&sensor_dev_attr_pwm1_auto_point6_temp.dev_attr.attr,
+	&sensor_dev_attr_pwm1_auto_point7_temp.dev_attr.attr,
+	&sensor_dev_attr_pwm1_auto_point8_temp.dev_attr.attr,
+	NULL,
+};
+ATTRIBUTE_GROUPS(axi_fan_control);
+
 static const u32 version_1_0_0 = ADI_AXI_PCORE_VER(1, 0, 'a');
 
 static const struct of_device_id axi_fan_control_of_match[] = {
@@ -502,7 +574,7 @@ static int axi_fan_control_probe(struct platform_device *pdev)
 							 name,
 							 ctl,
 							 &axi_chip_info,
-							 NULL);
+							 axi_fan_control_groups);
 
 	return PTR_ERR_OR_ZERO(ctl->hdev);
 }
Signature · 1 line
2.32.0
maintainer
#18 lore raw

Re: [RFC PATCH 6/6] hwmon: axi-fan-control: support temperature vs pwm points

Quoted 4 lines · Nuno Sá

The HW has some predefined points where it will associate a PWM value. However some users might want to better set these points to their usecases. This patch exposes these points as pwm auto_points:

Quoted 17 lines

* pwm1_auto_point1_temp: temperature threshold below which PWM should be 0%;
* pwm1_auto_point2_temp: temperature threshold above which PWM should be 25%;
* pwm1_auto_point3_temp: temperature threshold below which PWM should be 25%;
* pwm1_auto_point4_temp: temperature threshold above which PWM should be 50%;
* pwm1_auto_point5_temp: temperature threshold below which PWM should be 50%;
* pwm1_auto_point6_temp: temperature threshold above which PWM should be 75%;
* pwm1_auto_point7_temp: temperature threshold below which PWM should be 75%;
* pwm1_auto_point8_temp: temperature threshold above which PWM should be 100%;

If I understand those correctly, half of those are really hysteresis points. I think it would be better to express this with
pwm1_auto_pointX_temp
pwm1_auto_pointX_temp_hyst

where the hysteresis point is the temperature where the previous pwm value is activated. In other words, change attribute names as follows:

    for 25%:
	pwm1_auto_point1_temp -> pwm1_auto_point1_temp_hyst
	pwm1_auto_point2_temp -> pwm1_auto_point1_temp
    for 50%:
	pwm1_auto_point3_temp -> pwm1_auto_point2_temp_hyst
	pwm1_auto_point4_temp -> pwm1_auto_point2_temp
    for 75%:
	pwm1_auto_point5_temp -> pwm1_auto_point3_temp_hyst
	pwm1_auto_point6_temp -> pwm1_auto_point3_temp
    for 100%:
	pwm1_auto_point7_temp -> pwm1_auto_point4_temp_hyst
	pwm1_auto_point8_temp -> pwm1_auto_point4_temp

Thanks,
Guenter

author maintainer
#19 lore raw

RE: [RFC PATCH 6/6] hwmon: axi-fan-control: support temperature vs pwm points

Quoted 52 lines

From: Guenter Roeck <[email protected]> On Behalf Of Guenter Roeck
Sent: Saturday, July 17, 2021 7:23 PM
To: Sa, Nuno <[email protected]>
Cc: [email protected]; [email protected]; Rob Herring <[email protected]>; Jean Delvare <[email protected]>
Subject: Re: [RFC PATCH 6/6] hwmon: axi-fan-control: support temperature vs pwm points

[External]

Quoted 1 line · Nuno Sá

The HW has some predefined points where it will associate a PWM

value.

Quoted 4 lines

However some users might want to better set these points to their usecases. This patch exposes these points as pwm auto_points:

* pwm1_auto_point1_temp: temperature threshold below which

PWM should be

Quoted 2 lines
   0%;

* pwm1_auto_point2_temp: temperature threshold above which

PWM should be

Quoted 2 lines
   25%;

* pwm1_auto_point3_temp: temperature threshold below which

PWM should be

Quoted 2 lines
   25%;

* pwm1_auto_point4_temp: temperature threshold above which

PWM should be

Quoted 2 lines
   50%;

* pwm1_auto_point5_temp: temperature threshold below which

PWM should be

Quoted 2 lines
   50%;

* pwm1_auto_point6_temp: temperature threshold above which

PWM should be

Quoted 2 lines
   75%;

* pwm1_auto_point7_temp: temperature threshold below which

PWM should be

Quoted 2 lines
   75%;

* pwm1_auto_point8_temp: temperature threshold above which

PWM should be

Quoted 2 lines
   100%;

If I understand those correctly, half of those are really hysteresis points.
I think it would be better to express this with
pwm1_auto_pointX_temp
pwm1_auto_pointX_temp_hyst

where the hysteresis point is the temperature where the previous pwm value
is activated. In other words, change attribute names as follows:

Quoted 13 lines
    for 25%:
	pwm1_auto_point1_temp -> pwm1_auto_point1_temp_hyst
	pwm1_auto_point2_temp -> pwm1_auto_point1_temp
    for 50%:
	pwm1_auto_point3_temp -> pwm1_auto_point2_temp_hyst
	pwm1_auto_point4_temp -> pwm1_auto_point2_temp
    for 75%:
	pwm1_auto_point5_temp -> pwm1_auto_point3_temp_hyst
	pwm1_auto_point6_temp -> pwm1_auto_point3_temp
    for 100%:
	pwm1_auto_point7_temp -> pwm1_auto_point4_temp_hyst
	pwm1_auto_point8_temp -> pwm1_auto_point4_temp

Agree, it makes sense.

- Nuno Sá

author maintainer
#20 lore raw
In reply to Nuno Sá

Hi Guenter,

Quoted 40 lines

From: Nuno Sá <[email protected]>
Sent: Thursday, July 8, 2021 2:01 PM
To: [email protected]; [email protected]
Cc: Guenter Roeck <[email protected]>; Rob Herring <[email protected]>; Jean Delvare <[email protected]>
Subject: [RFC PATCH 0/6] AXI FAN new features and improvements

This series adds some new features to the axi-fan-control driver. On top
of that, the HW had some changes (basically it now starts automatically out of reset) so that the driver needed some minor refactoring. The reason I'm sending this as RFC, is mainly because of the last patch ("hwmon: axi-fan-control: support temperature vs pwm points"). The core
has some predefined values which define a temperature vs pwm curve [1].
It also exposes registers so that users can change it according to their needs. As I could not find standard attributes in the subsystem, I'm proposing some "raw" sysfs files. Looking at [2], the pwm_auto_point stuff looked to be what I want. Obviously I might be wrong :). If this is accepted, I will add a proper sysfs DOC file describing the new files (being lazy in the RFC).

For patch 5 ("hwmon: axi-fan-control: clear the fan fault irq at startup"),
it's also arguable if we really need it. The main reason I have it is because of some userland apps that might take some drastic measures by
just reading 1 fan_fault alarm. Obviously, we can argue that the problem
is in the app and not in the driver. Though it's such a minimal change that I decided to include it (I'm more than fine in dropping the patch).

[1]: https://wiki.analog.com/resources/fpga/docs/axi_fan_control
[2]:
https://urldefense.com/v3/__https://www.kernel.org/doc/Documen
tation/hwmon/sysfs- interface__;!!A3Ni8CS0y2Y!uwjpaOT8QEBVfKTCWELJNbjJJ69iR7S3tKS WV4B0K742CtcARkTtAqMxknnpPw$

Quoted 8 lines

Nuno Sá (6):
hwmon: axi-fan-control: make sure the clock is enabled
hwmon: axi-fan-control: add tacho devicetree properties
dt-bindings: axi-fan-control: add tacho properties
hwmon: axi-fan-control: handle irqs in natural order
hwmon: axi-fan-control: clear the fan fault irq at startup
hwmon: axi-fan-control: support temperature vs pwm points

The HW guy is willing to change how the core works. This means, that all that unstable pwm - rpm points will go away and we will have a register where we can set the minimum fan speed for evaluating the FAN. He also said that the default value for the this setting will be pretty low so that we should only have _real_ faults at startup which means patch 5 should not be needed anymore...

Anyways, I will send a new pull with patches 1,3 and 5 and as soon as I have some HW ready to test, I will send the other patches. With the new mechanism, we can also simplify the IRQ handling [1]...

For the new devicetree property, I think now it really is a fan property which makes me wonder if the property will be accepted in the controller bindings or if I need to send a fan.yaml...

[1]: https://elixir.bootlin.com/linux/v5.14-rc3/source/drivers/hwmon/axi-fan-control.c#L280

- Nuno Sá

maintainer
#21 lore raw

Hi,

Quoted 60 lines · Nuno

Hi Guenter,

Quoted 40 lines

From: Nuno Sá <[email protected]>
Sent: Thursday, July 8, 2021 2:01 PM
To: [email protected]; [email protected]
Cc: Guenter Roeck <[email protected]>; Rob Herring <[email protected]>; Jean Delvare <[email protected]>
Subject: [RFC PATCH 0/6] AXI FAN new features and improvements

This series adds some new features to the axi-fan-control driver. On top
of that, the HW had some changes (basically it now starts automatically out of reset) so that the driver needed some minor refactoring. The reason I'm sending this as RFC, is mainly because of the last patch ("hwmon: axi-fan-control: support temperature vs pwm points"). The core
has some predefined values which define a temperature vs pwm curve [1].
It also exposes registers so that users can change it according to their needs. As I could not find standard attributes in the subsystem, I'm proposing some "raw" sysfs files. Looking at [2], the pwm_auto_point stuff looked to be what I want. Obviously I might be wrong :). If this is accepted, I will add a proper sysfs DOC file describing the new files (being lazy in the RFC).

For patch 5 ("hwmon: axi-fan-control: clear the fan fault irq at startup"),
it's also arguable if we really need it. The main reason I have it is because of some userland apps that might take some drastic measures by
just reading 1 fan_fault alarm. Obviously, we can argue that the problem
is in the app and not in the driver. Though it's such a minimal change that I decided to include it (I'm more than fine in dropping the patch).

[1]: https://wiki.analog.com/resources/fpga/docs/axi_fan_control
[2]:
https://urldefense.com/v3/__https://www.kernel.org/doc/Documen
tation/hwmon/sysfs- interface__;!!A3Ni8CS0y2Y!uwjpaOT8QEBVfKTCWELJNbjJJ69iR7S3tKS WV4B0K742CtcARkTtAqMxknnpPw$

Quoted 8 lines

Nuno Sá (6):
hwmon: axi-fan-control: make sure the clock is enabled
hwmon: axi-fan-control: add tacho devicetree properties
dt-bindings: axi-fan-control: add tacho properties
hwmon: axi-fan-control: handle irqs in natural order
hwmon: axi-fan-control: clear the fan fault irq at startup
hwmon: axi-fan-control: support temperature vs pwm points

The HW guy is willing to change how the core works. This means, that all that unstable pwm - rpm points will go away and we will have a register where we can set the minimum fan speed for evaluating the FAN. He also said that the default value for the this setting will be pretty low so that we should only have _real_ faults at startup which means patch 5 should not be needed anymore...

Quoted 1 line

Anyways, I will send a new pull with patches 1,3 and 5 and

That kind of contradicts what you say above, that patch 5 won't be needed anymore. Am I missing something ?

Quoted 8 lines

as soon as I have some HW ready to test, I will send the other patches. With the new mechanism, we can also simplify the IRQ handling [1]...

For the new devicetree property, I think now it really is a fan property which makes me wonder if the property will be accepted in the controller bindings or if I need to send a fan.yaml...

Not really sure myself. At he very least we'll have sysfs properties, so the minimum speed could also be updated from userspace. Ultimately we'll need some set of devicetree properties, not only for fans but for pretty much everything supported by hwmon, but I have no idea what is acceptable and what isn't - if I did I might have proposed something by now.

Guenter

author maintainer
#22 lore raw
Quoted 88 lines

-----Original Message-----
From: Guenter Roeck <[email protected]> On Behalf Of Guenter Roeck
Sent: Wednesday, July 28, 2021 8:38 PM
To: Sa, Nuno <[email protected]>; [email protected]; [email protected]
Cc: Rob Herring <[email protected]>; Jean Delvare <[email protected]>
Subject: Re: [RFC PATCH 0/6] AXI FAN new features and improvements

[External]

Hi,

Quoted 11 lines · Nuno

Hi Guenter,

Quoted 8 lines

From: Nuno Sá <[email protected]>
Sent: Thursday, July 8, 2021 2:01 PM
To: [email protected]; [email protected]
Cc: Guenter Roeck <[email protected]>; Rob Herring <[email protected]>; Jean Delvare <[email protected]>
Subject: [RFC PATCH 0/6] AXI FAN new features and improvements

This series adds some new features to the axi-fan-control driver.

On

Quoted 2 lines
Quoted 2 lines

top
of that, the HW had some changes (basically it now starts

automatically

Quoted 3 lines
Quoted 3 lines

out of reset) so that the driver needed some minor refactoring. The reason I'm sending this as RFC, is mainly because of the last patch ("hwmon: axi-fan-control: support temperature vs pwm points").

The

Quoted 4 lines
Quoted 4 lines

core
has some predefined values which define a temperature vs pwm curve [1].
It also exposes registers so that users can change it according to

their

Quoted 2 lines
Quoted 2 lines

needs. As I could not find standard attributes in the subsystem, I'm proposing some "raw" sysfs files. Looking at [2], the

pwm_auto_point

Quoted 2 lines
Quoted 2 lines

stuff looked to be what I want. Obviously I might be wrong :). If this is accepted, I will add a proper sysfs DOC file describing the new

files

Quoted 6 lines
Quoted 6 lines

(being lazy in the RFC).

For patch 5 ("hwmon: axi-fan-control: clear the fan fault irq at startup"),
it's also arguable if we really need it. The main reason I have it is because of some userland apps that might take some drastic

measures

Quoted 5 lines
Quoted 5 lines

by
just reading 1 fan_fault alarm. Obviously, we can argue that the problem
is in the app and not in the driver. Though it's such a minimal change that I decided to include it (I'm more than fine in dropping the

patch).

Quoted 4 lines
Quoted 4 lines

[1]: https://wiki.analog.com/resources/fpga/docs/axi_fan_control
[2]:

https://urldefense.com/v3/__https://www.kernel.org/doc/Documen

Quoted 2 lines
Quoted 2 lines

tation/hwmon/sysfs-

interface__;!!A3Ni8CS0y2Y!uwjpaOT8QEBVfKTCWELJNbjJJ69iR7S3tKS

Quoted 19 lines
Quoted 10 lines

WV4B0K742CtcARkTtAqMxknnpPw$

Nuno Sá (6):
hwmon: axi-fan-control: make sure the clock is enabled
hwmon: axi-fan-control: add tacho devicetree properties
dt-bindings: axi-fan-control: add tacho properties
hwmon: axi-fan-control: handle irqs in natural order
hwmon: axi-fan-control: clear the fan fault irq at startup
hwmon: axi-fan-control: support temperature vs pwm points

The HW guy is willing to change how the core works. This means, that all that unstable pwm - rpm points will go away and we will have a register where we can set the minimum fan speed for evaluating the FAN. He also said that the default value for the this setting will be pretty low so that we should only have _real_ faults at startup which means patch 5 should not be needed anymore...

Quoted 4 lines
Quoted 1 line

Anyways, I will send a new pull with patches 1,3 and 5 and

That kind of contradicts what you say above, that patch 5 won't be needed anymore. Am I missing something ?

My bad... I meant patch 6 and not 5.

- Nuno Sá