AXI FAN new features and improvements
Nuno Sá
maintainercover AXI FAN new features and improvements
This series adds some new features to the axi-fan-control driver. On top of that, the HW had some changes (basically it now starts automatically out of reset) so that the driver needed some minor refactoring. The reason I'm sending this as RFC, is mainly because of the last patch ("hwmon: axi-fan-control: support temperature vs pwm points"). The core has some predefined values which define a temperature vs pwm curve [1]. It also exposes registers so that users can change it according to their needs. As I could not find standard attributes in the subsystem, I'm proposing some "raw" sysfs files. Looking at [2], the pwm_auto_point stuff looked to be what I want. Obviously I might be wrong :). If this is accepted, I will add a proper sysfs DOC file describing the new files (being lazy in the RFC).
For patch 5 ("hwmon: axi-fan-control: clear the fan fault irq at startup"), it's also arguable if we really need it. The main reason I have it is because of some userland apps that might take some drastic measures by just reading 1 fan_fault alarm. Obviously, we can argue that the problem is in the app and not in the driver. Though it's such a minimal change that I decided to include it (I'm more than fine in dropping the patch).
[1]: https://wiki.analog.com/resources/fpga/docs/axi_fan_control
[2]: https://www.kernel.org/doc/Documentation/hwmon/sysfs-interface
Nuno Sá (6):
hwmon: axi-fan-control: make sure the clock is enabled
hwmon: axi-fan-control: add tacho devicetree properties
dt-bindings: axi-fan-control: add tacho properties
hwmon: axi-fan-control: handle irqs in natural order
hwmon: axi-fan-control: clear the fan fault irq at startup
hwmon: axi-fan-control: support temperature vs pwm points
.../bindings/hwmon/adi,axi-fan-control.yaml | 12 ++ drivers/hwmon/axi-fan-control.c | 160 ++++++++++++++++-- 2 files changed, 156 insertions(+), 16 deletions(-)
Signature · 1 line
2.32.0
Nuno Sá
maintainerRFC PATCH 1/6 hwmon: axi-fan-control: make sure the clock is enabled
The core will only work if it's clock is enabled. This patch is a minor enhancement to make sure that's the case.
--- drivers/hwmon/axi-fan-control.c | 13 +++++++++++++ 1 file changed, 13 insertions(+)
drivers/hwmon/axi-fan-control.c +13 -0
@@ -351,6 +351,11 @@ static int axi_fan_control_init(struct axi_fan_control_data *ctl,return ret; } +static void axi_fan_control_clk_disable (void *clk) +{ +clk_disable_unprepare (clk); +} +static const struct hwmon_channel_info *axi_fan_control_info[] = {HWMON_CHANNEL_INFO (pwm,HWMON_PWM_INPUT ),HWMON_CHANNEL_INFO (fan,HWMON_F_INPUT |HWMON_F_FAULT |HWMON_F_LABEL ),
@@ -406,6 +411,14 @@ static int axi_fan_control_probe(struct platform_device *pdev)return PTR_ERR (clk); } + ret =clk_prepare_enable (clk); +if (ret) +return ret; + + ret =devm_add_action_or_reset (&pdev->dev, axi_fan_control_clk_disable, clk); +if (ret) +return ret; + ctl->clk_rate =clk_get_rate (clk);if (!ctl->clk_rate)return -EINVAL ;
Signature · 1 line
2.32.0
Guenter Roeck
maintainerRe: [RFC PATCH 1/6] hwmon: axi-fan-control: make sure the clock is enabled
Quoted 4 lines · Nuno Sá
The core will only work if it's clock is enabled. This patch is a minor enhancement to make sure that's the case.
Signed-off-by Nuno Sá <[email protected]>
Can I apply this patch as well as patches 4/6 and 5/6 as-is, or do they depend on patches 2/6 and 3/6 ?
Thanks,
Guenter
Sa, Nuno
maintainerRE: [RFC PATCH 1/6] hwmon: axi-fan-control: make sure the clock is enabled
Quoted 17 lines
-----Original Message-----
From: Guenter Roeck <[email protected]> On Behalf Of Guenter Roeck
Sent: Saturday, July 17, 2021 7:25 PM
To: Sa, Nuno <[email protected]>
Cc: [email protected]; [email protected]; Rob Herring <[email protected]>; Jean Delvare <[email protected]>
Subject: Re: [RFC PATCH 1/6] hwmon: axi-fan-control: make sure the clock is enabledQuoted 3 lines · Nuno Sá
The core will only work if it's clock is enabled. This patch is a minor enhancement to make sure that's the case.
Quoted 7 lines
Quoted 1 line
Signed-off-by Nuno Sá <[email protected]>Can I apply this patch as well as patches 4/6 and 5/6 as-is, or do they depend on patches 2/6 and 3/6 ?
Thanks,
Guenter
I think patch 5/6 only makes sense with patch 2/6. If we do not set the tacho evaluation parameters, clearing the fan fault irq has no effect...
- Nuno Sá
Nuno Sá
maintainerRFC PATCH 2/6 hwmon: axi-fan-control: add tacho devicetree properties
In reply to Nuno SáThis core is capable to run without any user interaction and when it does, it uses some predefined values in order to evaluate the tacho signal from the FAN. These values depend on the attached FAN, so that the core now exposes registers to change them accordingly. The values are:
* adi,tacho-25-us: Expected tacho signal when the PWM is 25%;
* adi,tacho-50-us: Expected tacho signal when the PWM is 50%;
* adi,tacho-75-us: Expected tacho signal when the PWM is 75%;
* adi,tacho-100-us: Expected tacho signal when the PWM is 100%.
--- drivers/hwmon/axi-fan-control.c | 34 +++++++++++++++++++++++++++++++++ 1 file changed, 34 insertions(+)
drivers/hwmon/axi-fan-control.c +34 -0
@@ -23,6 +23,14 @@#define ADI_REG_PWM_PERIOD 0x00c0#define ADI_REG_TACH_MEASUR 0x00c4#define ADI_REG_TEMPERATURE 0x00c8 +#define ADI_REG_TACH_25 0x0140 +#define ADI_REG_TACH_50 0x0144 +#define ADI_REG_TACH_75 0x0148 +#define ADI_REG_TACH_100 0x014c +#define ADI_REG_TACH_25_TOL 0x0150 +#define ADI_REG_TACH_50_TOL 0x0154 +#define ADI_REG_TACH_75_TOL 0x0158 +#define ADI_REG_TACH_100_TOL 0x015c#define ADI_REG_IRQ_MASK 0x0040#define ADI_REG_IRQ_PENDING 0x0044
@@ -328,6 +336,7 @@ static int axi_fan_control_init(struct axi_fan_control_data *ctl, const struct device_node *np) {int ret; +u32 tacho_val;/* get fan pulses per revolution */ ret =of_property_read_u32 (np,"pulses-per-revolution" , &ctl->ppr);
@@ -337,6 +346,31 @@ static int axi_fan_control_init(struct axi_fan_control_data *ctl,/* 1, 2 and 4 are the typical and accepted values */ if (ctl->ppr !=1 && ctl->ppr !=2 && ctl->ppr !=4 )return -EINVAL ; + +if (!of_property_read_u32 (np,"adi,tacho-25-us" , &tacho_val)) { + tacho_val =DIV_ROUND_CLOSEST_ULL ((u64 )tacho_val * ctl->clk_rate,1000000 ); +axi_iowrite (tacho_val,ADI_REG_TACH_25 , ctl); +axi_iowrite (DIV_ROUND_CLOSEST (tacho_val *25 ,100 ),ADI_REG_TACH_25_TOL , ctl); + } + +if (!of_property_read_u32 (np,"adi,tacho-50-us" , &tacho_val)) { + tacho_val =DIV_ROUND_CLOSEST_ULL ((u64 )tacho_val * ctl->clk_rate,1000000 ); +axi_iowrite (tacho_val,ADI_REG_TACH_50 , ctl); +axi_iowrite (DIV_ROUND_CLOSEST (tacho_val *25 ,100 ),ADI_REG_TACH_50_TOL , ctl); + } + +if (!of_property_read_u32 (np,"adi,tacho-75-us" , &tacho_val)) { + tacho_val =DIV_ROUND_CLOSEST_ULL ((u64 )tacho_val * ctl->clk_rate,1000000 ); +axi_iowrite (tacho_val,ADI_REG_TACH_75 , ctl); +axi_iowrite (DIV_ROUND_CLOSEST (tacho_val *25 ,100 ),ADI_REG_TACH_75_TOL , ctl); + } + +if (!of_property_read_u32 (np,"adi,tacho-100-us" , &tacho_val)) { + tacho_val =DIV_ROUND_CLOSEST_ULL ((u64 )tacho_val * ctl->clk_rate,1000000 ); +axi_iowrite (tacho_val,ADI_REG_TACH_100 , ctl); +axi_iowrite (DIV_ROUND_CLOSEST (tacho_val *25 ,100 ),ADI_REG_TACH_100_TOL , ctl); + } +/* * Enable all IRQs */
Signature · 1 line
2.32.0
Nuno Sá
maintainerRFC PATCH 3/6 dt-bindings: axi-fan-control: add tacho properties
In reply to Nuno SáAdd the bindings for the tacho signal evaluation parameters which depend on the FAN being used.
--- .../bindings/hwmon/adi,axi-fan-control.yaml | 12 ++++++++++++ 1 file changed, 12 insertions(+)
Documentation/devicetree/bindings/hwmon/adi,axi-fan-control.yaml +12 -0
@@ -37,6 +37,18 @@ properties: $ref: /schemas/types.yaml#/definitions/uint32 enum: [1, 2, 4] + adi,tacho-25-us: + description: Expected tacho signal when the PWM is at 25%. + + adi,tacho-50-us: + description: Expected tacho signal when the PWM is at 50%. + + adi,tacho-75-us: + description: Expected tacho signal when the PWM is at 75%. + + adi,tacho-100-us: + description: Expected tacho signal when the PWM is at 100%. + required: - compatible - reg
Signature · 1 line
2.32.0
Rob Herring
maintainerRe: [RFC PATCH 3/6] dt-bindings: axi-fan-control: add tacho properties
Quoted 17 lines · Nuno Sá
Add the bindings for the tacho signal evaluation parameters which depend on the FAN being used.
Signed-off-by Nuno Sá <[email protected]>--- .../bindings/hwmon/adi,axi-fan-control.yaml | 12 ++++++++++++ 1 file changed, 12 insertions(+)Documentation/devicetree/bindings/hwmon/adi,axi-fan-control.yaml +1
-0@@ -37,6 +37,18 @@ properties: $ref: /schemas/types.yaml#/definitions/uint32 enum: [1, 2, 4] + adi,tacho-25-us:
Documentation/devicetree/bindings/hwmon/adi,axi-fan-control.yaml properties: · line 50
Quoted 10 lines
Documentation/devicetree/bindings/hwmon/adi,axi-fan-control.yaml +10
-0+ description: Expected tacho signal when the PWM is at 25%. + + adi,tacho-50-us: + description: Expected tacho signal when the PWM is at 50%. + + adi,tacho-75-us: + description: Expected tacho signal when the PWM is at 75%. + + adi,tacho-100-us: + description: Expected tacho signal when the PWM is at 100%.
This looks like it should be common. But having PWM percents in the property names doesn't scale. This is also a property of the fan, not the fan controller.
There's only so many ways a fan can be controlled and I'm going to keep telling folks to make a common fan binding. There's some start to it, but it needs some work.
Rob
Sa, Nuno
maintainerRE: [RFC PATCH 3/6] dt-bindings: axi-fan-control: add tacho properties
Quoted 34 lines
From: Rob Herring <[email protected]>
Sent: Monday, July 12, 2021 7:27 PM
To: Sa, Nuno <[email protected]>
Cc: [email protected]; [email protected]; Guenter Roeck <[email protected]>; Jean Delvare <[email protected]>
Subject: Re: [RFC PATCH 3/6] dt-bindings: axi-fan-control: add tacho properties[External]
Quoted 1 line · Nuno Sá
Add the bindings for the tacho signal evaluation parameters which
depend
Quoted 5 lines
on the FAN being used.
Signed-off-by Nuno Sá <[email protected]>--- .../bindings/hwmon/adi,axi-fan-control.yaml | 12++++++++++++
Review
Quoted 3 lines
1 file changed, 12 insertions(+)(quoted diff) +0
-0
control.yamlb/Documentation/devicetree/bindings/hwmon/adi,axi-fan-control.yamlQuoted 2 lines
index
6747b870f297..0481eb34d9f1100644
--- a/Documentation/devicetree/bindings/hwmon/adi,axi-fan-
control.yamlQuoted 1 line
+++ b/Documentation/devicetree/bindings/hwmon/adi,axi-fan-
control.yamlQuoted 4 lines
Documentation/devicetree/bindings/hwmon/adi,axi-fan-control.yaml +0
-0@@ -37,6 +37,18 @@ properties: $ref: /schemas/types.yaml#/definitions/uint32 enum: [1, 2, 4]
Quoted 15 lines
Documentation/devicetree/bindings/hwmon/adi,axi-fan-control.yaml properties: · line 50
Quoted 11 lines
Documentation/devicetree/bindings/hwmon/adi,axi-fan-control.yaml +11
-0+ adi,tacho-25-us: + description: Expected tacho signal when the PWM is at 25%. + + adi,tacho-50-us: + description: Expected tacho signal when the PWM is at 50%. + + adi,tacho-75-us: + description: Expected tacho signal when the PWM is at 75%. + + adi,tacho-100-us: + description: Expected tacho signal when the PWM is at 100%.This looks like it should be common. But having PWM percents in the property names doesn't scale. This is also a property of the fan, not the fan controller.
Yes, I see that these parameters are definitely a property of the attached fan but the evaluation of these timings are very specific to this controller (I think). The way it works is that the HW can fully operate without any runtime SW configuration. In this case, it will use the values in these registers to evaluate the tacho signal coming from the FAN. And the HW really uses the evaluation points like this (0, 25%, 50% and 100%). It has some predefined values that work for the FAN that was used to develop the IP but naturally the evaluation will fail as soon as other FAN is attached (resulting in fan fault interrupts). And yes, writing these parameters is already SW configuration but what I mean with "runtime" is after probe :).
So, I honestly do not know how we could name this better... Maybe a 'tacho-eval-points-us' array? The question would be the min/max elements? Do you have any suggestion for a more generic property?
Quoted 4 lines
There's only so many ways a fan can be controlled and I'm going to keep
telling folks to make a common fan binding. There's some start to it, but it needs some work.
You mean the pwm-fan.txt? I gave a look to the driver and I don't think it fully fits this controller. I'm ok in sending an fan.yaml binding if you prefer it but I'm just not sure what we would need there... Maybe pulses-per-revolution and the above property
(whatever the decided name) would be a starting point?
- Nuno Sá
Guenter Roeck
maintainerRe: [RFC PATCH 3/6] dt-bindings: axi-fan-control: add tacho properties
Quoted 50 lines · Nuno
Quoted 34 lines
From: Rob Herring <[email protected]>
Sent: Monday, July 12, 2021 7:27 PM
To: Sa, Nuno <[email protected]>
Cc: [email protected]; [email protected]; Guenter Roeck <[email protected]>; Jean Delvare <[email protected]>
Subject: Re: [RFC PATCH 3/6] dt-bindings: axi-fan-control: add tacho properties[External]
Quoted 1 line · Nuno Sá
Add the bindings for the tacho signal evaluation parameters which
depend
Quoted 5 lines
on the FAN being used.
Signed-off-by Nuno Sá <[email protected]>--- .../bindings/hwmon/adi,axi-fan-control.yaml | 12++++++++++++
Review
Quoted 3 lines
1 file changed, 12 insertions(+)(quoted diff) +0
-0
control.yamlb/Documentation/devicetree/bindings/hwmon/adi,axi-fan-control.yamlQuoted 2 lines
index
6747b870f297..0481eb34d9f1100644
--- a/Documentation/devicetree/bindings/hwmon/adi,axi-fan-
control.yamlQuoted 1 line
+++ b/Documentation/devicetree/bindings/hwmon/adi,axi-fan-
control.yamlQuoted 4 lines
Documentation/devicetree/bindings/hwmon/adi,axi-fan-control.yaml +0
-0@@ -37,6 +37,18 @@ properties: $ref: /schemas/types.yaml#/definitions/uint32 enum: [1, 2, 4]Quoted 15 lines
Documentation/devicetree/bindings/hwmon/adi,axi-fan-control.yaml properties: · line 50
Quoted 11 lines
Documentation/devicetree/bindings/hwmon/adi,axi-fan-control.yaml +11
-0+ adi,tacho-25-us: + description: Expected tacho signal when the PWM is at 25%. + + adi,tacho-50-us: + description: Expected tacho signal when the PWM is at 50%. + + adi,tacho-75-us: + description: Expected tacho signal when the PWM is at 75%. + + adi,tacho-100-us: + description: Expected tacho signal when the PWM is at 100%.This looks like it should be common. But having PWM percents in the property names doesn't scale. This is also a property of the fan, not the fan controller.
Quoted 11 lines
Yes, I see that these parameters are definitely a property of the attached fan but the evaluation of these timings are very specific to this controller (I think). The way it works is that the HW can fully operate without any runtime SW configuration. In this case, it will use the values in these registers to evaluate the tacho signal coming from the FAN. And the HW really uses the evaluation points like this (0, 25%, 50% and 100%). It has some predefined values that work for the FAN that was used to develop the IP but naturally the evaluation will fail as soon as other FAN is attached (resulting in fan fault interrupts). And yes, writing these parameters is already SW configuration but what I mean with "runtime" is after probe :).
Are you sure you can ever get this stable ? Each fan has its own properties and tolerances. If you replace a fan in a given system, you might get different RPM numbers. The RPM will differ widely from system to system and from fan to fan. Anything that assumes a specific RPM in devicetree data seems to be quite vulnerable to failures. I have experienced that recently with a different chip which also tries to correlate RPM and PWM and fails quite miserably.
In my experience, anything other than minimum fan speed is really a recipe for instability and sporadic false failures. Even setting a minimum fan speed is tricky because it depends a lot on the fan.
Quoted 4 lines
So, I honestly do not know how we could name this better... Maybe a 'tacho-eval-points-us' array? The question would be the min/max elements? Do you have any suggestion for a more generic property?
I am guessing that the "us" refers to the time between pulses from the fan. I think this is a bad value to start with - anything fan speed related should really be expressed in RPM, not in time between pulses.
Overall I don't think this should be handled as generic set of properties. Whatever we come up with as standard set of pwm or fan related properties should not be an expected correlation between pwm and rpm. Assuming such a property is needed here (after all, the controller is what it is), maybe a set of tuples makes sense, such as
adi,pwm-rpm-map = < 25, 250, 50, 500, 75, 750, 100, 1000 >;
though I think that each of those should also include the tolerance instead of just assuming that a 25% tolerance (as implemented in patch 2/6) would work for all fans.
Guenter
Quoted 12 lines
Quoted 4 lines
There's only so many ways a fan can be controlled and I'm going to keep
telling folks to make a common fan binding. There's some start to it, but it needs some work.You mean the pwm-fan.txt? I gave a look to the driver and I don't think it fully fits this controller. I'm ok in sending an
fan.yamlbinding if you prefer it but I'm just not sure what we would need there... Maybe pulses-per-revolution and the above property
(whatever the decided name) would be a starting point?- Nuno Sá
Sa, Nuno
maintainerRE: [RFC PATCH 3/6] dt-bindings: axi-fan-control: add tacho properties
Quoted 98 lines
From: Guenter Roeck <[email protected]> On Behalf Of Guenter Roeck
Sent: Thursday, July 15, 2021 10:40 PM
To: Sa, Nuno <[email protected]>
Cc: Rob Herring <[email protected]>; [email protected]; [email protected]; Jean Delvare <[email protected]>
Subject: Re: [RFC PATCH 3/6] dt-bindings: axi-fan-control: add tacho propertiesQuoted 7 lines · Nuno
Quoted 7 lines
From: Rob Herring <[email protected]>
Sent: Monday, July 12, 2021 7:27 PM
To: Sa, Nuno <[email protected]>
Cc: [email protected]; [email protected]; Guenter Roeck <[email protected]>; Jean Delvare <[email protected]>
Subject: Re: [RFC PATCH 3/6] dt-bindings: axi-fan-control: addtacho
Quoted 6 lines
Quoted 6 lines
properties
[External]
Quoted 1 line · Nuno Sá
Add the bindings for the tacho signal evaluation parameters
which
Quoted 10 lines
Quoted 10 lines
depend
Quoted 5 lines
on the FAN being used.
Signed-off-by Nuno Sá <[email protected]>--- .../bindings/hwmon/adi,axi-fan-control.yaml | 12++++++++++++
Review
Quoted 3 lines
1 file changed, 12 insertions(+)(quoted diff) +0
-0fan-
Quoted 1 line
Quoted 1 line
control.yamlb/Documentation/devicetree/bindings/hwmon/adi,axi-
Quoted 10 lines
Quoted 10 lines
fan-control.yamlQuoted 2 lines
index
6747b870f297..0481eb34d9f1100644
--- a/Documentation/devicetree/bindings/hwmon/adi,axi-fan-
control.yamlQuoted 1 line
+++ b/Documentation/devicetree/bindings/hwmon/adi,axi-fan-
control.yamlQuoted 4 lines
Documentation/devicetree/bindings/hwmon/adi,axi-fan-control.yaml +0
-0@@ -37,6 +37,18 @@ properties: $ref: /schemas/types.yaml#/definitions/uint32 enum: [1, 2, 4]Quoted 13 lines
Quoted 5 lines
Quoted 5 lines
Documentation/devicetree/bindings/hwmon/adi,axi-fan-control.yaml +5
-0+ adi,tacho-25-us: + description: Expected tacho signal when the PWM is at 25%. + + adi,tacho-50-us: + description: Expected tacho signal when the PWM is at 50%.Quoted 8 lines
Documentation/devicetree/bindings/hwmon/adi,axi-fan-control.yaml properties: · line 50
Quoted 6 lines
Documentation/devicetree/bindings/hwmon/adi,axi-fan-control.yaml +6
-0+ + adi,tacho-75-us: + description: Expected tacho signal when the PWM is at 75%. + + adi,tacho-100-us: + description: Expected tacho signal when the PWM is at 100%.This looks like it should be common. But having PWM percents in
the
Quoted 4 lines
Quoted 2 lines
property names doesn't scale. This is also a property of the fan, not the fan controller.
Yes, I see that these parameters are definitely a property of the
attached
Quoted 1 line
fan but the evaluation of these timings are very specific to this
controller
Quoted 1 line
(I think). The way it works is that the HW can fully operate without
any
Quoted 2 lines
runtime SW configuration. In this case, it will use the values in these registers to evaluate the tacho signal coming from the FAN. And the
HW
Quoted 1 line
really uses the evaluation points like this (0, 25%, 50% and 100%). It
has
Quoted 1 line
some predefined values that work for the FAN that was used to
develop
Quoted 1 line
the IP but naturally the evaluation will fail as soon as other FAN is
attached
Quoted 1 line
(resulting in fan fault interrupts). And yes, writing these parameters
is
Quoted 1 line
already SW configuration but what I mean with "runtime" is after
probe :).
Quoted 1 line
Are you sure you can ever get this stable ? Each fan has its own properties
and tolerances. If you replace a fan in a given system, you might get different RPM numbers. The RPM will differ widely from system to system
and from fan to fan. Anything that assumes a specific RPM in devicetree
data seems to be quite vulnerable to failures. I have experienced that recently with a different chip which also tries to correlate RPM and PWM
and fails quite miserably.
Quoted 5 lines
In my experience, anything other than minimum fan speed is really a recipe
for instability and sporadic false failures. Even setting a minimum fan speed
is tricky because it depends a lot on the fan.
I see what you mean. So, I had to go through this process when testing this changes because the fan I'm using is different from the default one used to develop and stablish the default values in the IP core. The core provides you with a register which contains the tacho measurements in clock cycles. You can read that for all the PWM points of interest (with devmem2 for example) and make your own "calibration". I assume that people have to go through this process before putting some values in the devicetree. I'm aware this is not the neatest process but I guess it's acceptable...
Quoted 26 lines
Quoted 1 line
So, I honestly do not know how we could name this better... Maybe
a
Quoted 3 lines
'tacho-eval-points-us' array? The question would be the min/max elements? Do you have any suggestion for a more generic property?
I am guessing that the "us" refers to the time between pulses from the fan. I think this is a bad value to start with - anything fan speed related should really be expressed in RPM, not in time between pulses.
Overall I don't think this should be handled as generic set of properties.
Whatever we come up with as standard set of pwm or fan related properties
should not be an expected correlation between pwm and rpm. Assuming such
a property is needed here (after all, the controller is what it is), maybe a set of tuples makes sense, such asadi,pwm-rpm-map = < 25, 250, 50, 500, 75, 750, 100, 1000 >;
Quoted 3 lines
though I think that each of those should also include the tolerance instead of just assuming that a 25% tolerance (as implemented in patch 2/6) would work for all fans.
Yes, this makes sense thanks. As the HW default tolerance is 25% I was somehow attached to that. Since all these values are correlated it makes complete sense to also give the tolerance here as it makes things more flexible. The map is also a good tip, I just have to see if there is a nice way to specify that the pwm column is constant...
Thanks!
- Nuno Sá
Guenter Roeck
maintainerRe: [RFC PATCH 3/6] dt-bindings: axi-fan-control: add tacho properties
On 7/16/21 12:44 AM, Sa, Nuno wrote:
[ ... ]
Quoted 19 lines
Quoted 13 lines
Are you sure you can ever get this stable ? Each fan has its own properties
and tolerances. If you replace a fan in a given system, you might get different RPM numbers. The RPM will differ widely from system to system
and from fan to fan. Anything that assumes a specific RPM in devicetree
data seems to be quite vulnerable to failures. I have experienced that recently with a different chip which also tries to correlate RPM and PWM
and fails quite miserably.Quoted 5 lines
In my experience, anything other than minimum fan speed is really a recipe
for instability and sporadic false failures. Even setting a minimum fan speed
is tricky because it depends a lot on the fan.
Quoted 3 lines
I see what you mean. So, I had to go through this process when testing this changes because the fan I'm using is different from the default one used to develop and stablish the default values in the IP core. The core
Exactly my point.
Quoted 7 lines
provides you with a register which contains the tacho measurements in clock cycles. You can read that for all the PWM points of interest (with devmem2 for example) and make your own "calibration". I assume that people have to go through this process before putting some values in the devicetree. I'm aware this is not the neatest process but I guess it's acceptable...
Do you really expect everyone using a system with this chip to go through this process and update its devicetree configuration, and then repeat it whenever a fan is changed ? Given how dynamic this is, I really wonder if that information should be in devicetree in the first place.
Guenter
Sa, Nuno
maintainerRE: [RFC PATCH 3/6] dt-bindings: axi-fan-control: add tacho properties
Quoted 56 lines
-----Original Message-----
From: Guenter Roeck <[email protected]> On Behalf Of Guenter Roeck
Sent: Friday, July 16, 2021 5:04 PM
To: Sa, Nuno <[email protected]>
Cc: Rob Herring <[email protected]>; [email protected]; [email protected]; Jean Delvare <[email protected]>
Subject: Re: [RFC PATCH 3/6] dt-bindings: axi-fan-control: add tacho properties[External]
On 7/16/21 12:44 AM, Sa, Nuno wrote:
[ ... ]Quoted 9 lines
Quoted 9 lines
Are you sure you can ever get this stable ? Each fan has its own properties
and tolerances. If you replace a fan in a given system, you might get different RPM numbers. The RPM will differ widely from system to system
and from fan to fan. Anything that assumes a specific RPM in devicetree
data seems to be quite vulnerable to failures. I have experiencedthat
Quoted 5 lines
Quoted 5 lines
recently with a different chip which also tries to correlate RPM and PWM
and fails quite miserably.In my experience, anything other than minimum fan speed is really
a
Quoted 2 lines
Quoted 2 lines
recipe
for instability and sporadic false failures. Even setting a minimumfan
Quoted 4 lines
Quoted 2 lines
speed
is tricky because it depends a lot on the fan.I see what you mean. So, I had to go through this process when
testing
Quoted 1 line
this changes because the fan I'm using is different from the default
one
Quoted 1 line
used to develop and stablish the default values in the IP core. The
core
Exactly my point.
Quoted 1 line
provides you with a register which contains the tacho measurements
in
Quoted 2 lines
clock cycles. You can read that for all the PWM points of interest (with devmem2 for example) and make your own "calibration". I
assume
Quoted 1 line
that people have to go through this process before putting some
values
Quoted 1 line
in the devicetree. I'm aware this is not the neatest process but I
guess it's
Quoted 9 lines
Quoted 2 lines
acceptable...
Do you really expect everyone using a system with this chip to go through
this process and update its devicetree configuration, and then repeat it whenever a fan is changed ? Given how dynamic this is, I really wonder if that information should be in devicetree in the first place.
My naive assumption was that we would only do this work at evaluation time. After that and after we settled with a fan for some system, I expected that changing to a different fan is not that likely. From your inputs, I guess this is not really the case which makes this process more cumbersome (as it also implies recompiling the devicetree for your system).
However, even if we export these as runtime parameters, services/daemons will also have an hard time doing this "calibration" in a dynamic way. The reason is because the way the controller works is that it only accepts a new PWM request if it is an higher value than whatever the HW has at that moment. Thus, going through the calibration points might be very cumbersome. I can see some ways of handling this though but not very neat...
Since this is a FPGA core, we might have some flexibility here. Something that came to my mind would be to have a calibration mode in the HW that would allow us to freely control the PWM values. In that way we could go freely over the calibration points. I guess, for safety reasons, this calibration mode would expire after some reasonable time (that give us enough time for doing the whole thing). The best place for doing the calibration, I guess it would be directly in the driver since we do receive the interrupts about new tacho measurements making things easier to sync and handle. However, given the time that takes for a new PWM to settle + new tacho measurements, it would not be very acceptable to do this during probe which is definitely also not ideal (we could defer this to a worker/timer).
I'm not sure if the above makes much sense to you and it also depends on the HW guys being on board with this mechanism.
- Nuno Sá
Guenter Roeck
maintainerRe: [RFC PATCH 3/6] dt-bindings: axi-fan-control: add tacho properties
Quoted 90 lines · Nuno
Quoted 56 lines
-----Original Message-----
From: Guenter Roeck <[email protected]> On Behalf Of Guenter Roeck
Sent: Friday, July 16, 2021 5:04 PM
To: Sa, Nuno <[email protected]>
Cc: Rob Herring <[email protected]>; [email protected]; [email protected]; Jean Delvare <[email protected]>
Subject: Re: [RFC PATCH 3/6] dt-bindings: axi-fan-control: add tacho properties[External]
On 7/16/21 12:44 AM, Sa, Nuno wrote:
[ ... ]Quoted 9 lines
Quoted 9 lines
Are you sure you can ever get this stable ? Each fan has its own properties
and tolerances. If you replace a fan in a given system, you might get different RPM numbers. The RPM will differ widely from system to system
and from fan to fan. Anything that assumes a specific RPM in devicetree
data seems to be quite vulnerable to failures. I have experiencedthat
Quoted 5 lines
Quoted 5 lines
recently with a different chip which also tries to correlate RPM and PWM
and fails quite miserably.In my experience, anything other than minimum fan speed is really
a
Quoted 2 lines
Quoted 2 lines
recipe
for instability and sporadic false failures. Even setting a minimumfan
Quoted 4 lines
Quoted 2 lines
speed
is tricky because it depends a lot on the fan.I see what you mean. So, I had to go through this process when
testing
Quoted 1 line
this changes because the fan I'm using is different from the default
one
Quoted 1 line
used to develop and stablish the default values in the IP core. The
core
Exactly my point.
Quoted 1 line
provides you with a register which contains the tacho measurements
in
Quoted 2 lines
clock cycles. You can read that for all the PWM points of interest (with devmem2 for example) and make your own "calibration". I
assume
Quoted 1 line
that people have to go through this process before putting some
values
Quoted 1 line
in the devicetree. I'm aware this is not the neatest process but I
guess it's
Quoted 9 lines
Quoted 2 lines
acceptable...
Do you really expect everyone using a system with this chip to go through
this process and update its devicetree configuration, and then repeat it whenever a fan is changed ? Given how dynamic this is, I really wonder if that information should be in devicetree in the first place.My naive assumption was that we would only do this work at evaluation time. After that and after we settled with a fan for some system, I expected that changing to a different fan is not that likely. From your inputs, I guess this is not really the case which makes this process more cumbersome (as it also implies recompiling the devicetree for your system).
However, even if we export these as runtime parameters, services/daemons will also have an hard time doing this "calibration" in a dynamic way. The reason is because the way the controller works is that it only accepts a new PWM request if it is an higher value than whatever the HW has at that moment. Thus, going through the calibration points might be very cumbersome. I can see some ways of handling this though but not very neat...
Since this is a FPGA core, we might have some flexibility here. Something that came to my mind would be to have a calibration mode in the HW that would allow us to freely control the PWM values. In that way we could go freely over the calibration points. I guess, for safety reasons, this calibration mode would expire after some reasonable time (that give us enough time for doing the whole thing). The best place for doing the calibration, I guess it would be directly in the driver since we do receive the interrupts about new tacho measurements making things easier to sync and handle. However, given the time that takes for a new PWM to settle + new tacho measurements, it would not be very acceptable to do this during probe which is definitely also not ideal (we could defer this to a worker/timer).
Quoted 3 lines
I'm not sure if the above makes much sense to you and it also depends on the HW guys being on board with this mechanism.
I don't really know what to say or recommend here. Personally I think any attempt to tie PWM values to RPM are doomed to fail. Here are a couple of examples:
Take your test system and move the fan to a restricted place (eg close to a wall). You'll see the fan RPM change, potentially significantly. Put it into some place with airflow towards or away from the system (eg blow air into the system from another place, which may happen if the system is installed in a lab), and again you'll see fan speed changes. Open the chassis, and the fan speed will change. I have seen fan speeds vary by up to 50% when changing airflow.
That doesn't even take into account that replacing a fan even with a similar model (eg after a fan failed) will likely result in potentially significant rpm changes.
Ultimately, anything that does more than determine if a fan is still running is potentially unstable.
Having said all that, it is really your call to decide how you want to detect fan failures.
Thanks,
Guenter
Sa, Nuno
maintainerRE: [RFC PATCH 3/6] dt-bindings: axi-fan-control: add tacho properties
Quoted 145 lines
From: Guenter Roeck <[email protected]> On Behalf Of Guenter Roeck
Sent: Wednesday, July 21, 2021 5:00 PM
To: Sa, Nuno <[email protected]>
Cc: Rob Herring <[email protected]>; [email protected]; [email protected]; Jean Delvare <[email protected]>
Subject: Re: [RFC PATCH 3/6] dt-bindings: axi-fan-control: add tacho propertiesQuoted 8 lines · Nuno
Quoted 8 lines
-----Original Message-----
From: Guenter Roeck <[email protected]> On Behalf Of Guenter Roeck
Sent: Friday, July 16, 2021 5:04 PM
To: Sa, Nuno <[email protected]>
Cc: Rob Herring <[email protected]>; linux-Quoted 2 lines
Quoted 2 lines
[email protected]; Jean Delvare <[email protected]>
Subject: Re: [RFC PATCH 3/6] dt-bindings: axi-fan-control: addtacho
Quoted 10 lines
Quoted 10 lines
properties
[External]
On 7/16/21 12:44 AM, Sa, Nuno wrote:
[ ... ]Quoted 4 lines
Quoted 4 lines
Are you sure you can ever get this stable ? Each fan has its own properties
and tolerances. If you replace a fan in a given system, you mightget
Quoted 1 line
Quoted 1 line
Quoted 1 line
Quoted 1 line
different RPM numbers. The RPM will differ widely from system
to
Quoted 4 lines
Quoted 4 lines
Quoted 4 lines
Quoted 4 lines
system
and from fan to fan. Anything that assumes a specific RPM in devicetree
data seems to be quite vulnerable to failures. I haveexperienced
Quoted 2 lines
Quoted 2 lines
that
Quoted 1 line
Quoted 1 line
recently with a different chip which also tries to correlate RPM
and
Quoted 4 lines
Quoted 4 lines
Quoted 4 lines
Quoted 4 lines
PWM
and fails quite miserably.In my experience, anything other than minimum fan speed is
really
Quoted 3 lines
Quoted 3 lines
a
Quoted 2 lines
Quoted 2 lines
recipe
for instability and sporadic false failures. Even setting aminimum
Quoted 7 lines
Quoted 7 lines
fan
Quoted 4 lines
Quoted 2 lines
speed
is tricky because it depends a lot on the fan.I see what you mean. So, I had to go through this process when
testing
Quoted 1 line
this changes because the fan I'm using is different from the
default
Quoted 2 lines
Quoted 2 lines
one
Quoted 1 line
used to develop and stablish the default values in the IP core.
The
Quoted 5 lines
Quoted 5 lines
core
Exactly my point.
Quoted 1 line
provides you with a register which contains the tacho
measurements
Quoted 6 lines
Quoted 6 lines
in
Quoted 2 lines
clock cycles. You can read that for all the PWM points of interest (with devmem2 for example) and make your own "calibration". I
assume
Quoted 1 line
that people have to go through this process before putting some
values
Quoted 8 lines
Quoted 8 lines
Quoted 1 line
in the devicetree. I'm aware this is not the neatest process but I
guess it's
Quoted 2 lines
acceptable...
Do you really expect everyone using a system with this chip to go through
this process and update its devicetree configuration, and thenrepeat it
Quoted 1 line
Quoted 1 line
whenever a fan is changed ? Given how dynamic this is, I really
wonder
Quoted 4 lines
Quoted 2 lines
if that information should be in devicetree in the first place.
My naive assumption was that we would only do this work at
evaluation
Quoted 1 line
time. After that and after we settled with a fan for some system, I
expected
Quoted 1 line
that changing to a different fan is not that likely. From your inputs, I
guess
Quoted 1 line
this is not really the case which makes this process more
cumbersome (as it
Quoted 3 lines
also implies recompiling the devicetree for your system).
However, even if we export these as runtime parameters,
services/daemons
Quoted 1 line
will also have an hard time doing this "calibration" in a dynamic way.
The reason
Quoted 1 line
is because the way the controller works is that it only accepts a new
PWM
Quoted 1 line
request if it is an higher value than whatever the HW has at that
moment. Thus,
Quoted 1 line
going through the calibration points might be very cumbersome. I
can see some
Quoted 3 lines
ways of handling this though but not very neat...
Since this is a FPGA core, we might have some flexibility here.
Something that
Quoted 1 line
came to my mind would be to have a calibration mode in the HW that
would
Quoted 1 line
allow us to freely control the PWM values. In that way we could go
freely over
Quoted 1 line
the calibration points. I guess, for safety reasons, this calibration
mode would
Quoted 1 line
expire after some reasonable time (that give us enough time for
doing the whole
Quoted 1 line
thing). The best place for doing the calibration, I guess it would be
directly in the
Quoted 1 line
driver since we do receive the interrupts about new tacho
measurements making
Quoted 1 line
things easier to sync and handle. However, given the time that takes
for a new
Quoted 1 line
PWM to settle + new tacho measurements, it would not be very
acceptable to do this
Quoted 1 line
during probe which is definitely also not ideal (we could defer this to
a worker/timer).
Quoted 2 lines
I'm not sure if the above makes much sense to you and it also
depends on the HW
Quoted 2 lines
guys being on board with this mechanism.
I don't really know what to say or recommend here. Personally I think any
attempt to tie PWM values to RPM are doomed to fail. Here are a couple of
examples:
Quoted 11 lines
Take your test system and move the fan to a restricted place (eg close to a
wall). You'll see the fan RPM change, potentially significantly. Put it into some place with airflow towards or away from the system (eg blow air into
the system from another place, which may happen if the system is installed
in a lab), and again you'll see fan speed changes. Open the chassis, and the fan speed will change. I have seen fan speeds vary by up to 50% when
changing airflow.
Here we can at least control the tolerance for each PWM vs RPM point but I can image this as a very painful process to get these values right and no one will think in setting tolerances of 50%...
Quoted 8 lines
That doesn't even take into account that replacing a fan even with a similar
model (eg after a fan failed) will likely result in potentially significant rpm changes.Ultimately, anything that does more than determine if a fan is still running
is potentially unstable.
Yeah, I understand your points. The HW does the evaluation and of course it also looks for the presence of a signal... So, in your opinion, not even setting a minimum fan speed is likely to be stable?
Quoted 4 lines
Having said all that, it is really your call to decide how you want to detect
fan failures.
Well, my hands are also tied here. The core is supposed to work without any SW interaction in which case the tacho evaluation is always done. The only thing I could do is to completely ignore fan faults which is also bad...
I can try to persuade the HW guy to completely remove the evaluation and just give fan fauts in case there's no signal but I'm not really sure he will go for it. In that case, I'm tempted to just leave this as-is (with the extra bindings for the tolerance and turn these bindings into a map) if you're willing to take it... The reason is that, as you said, this is likely to be unstable any ways so that the added complexity in the SW does not really pay off (better keep at least the SW simple)...
- Nuno Sá
Guenter Roeck
maintainerRe: [RFC PATCH 3/6] dt-bindings: axi-fan-control: add tacho properties
On 7/22/21 6:00 AM, Sa, Nuno wrote:
[ ... ]
Quoted 27 lines
Quoted 6 lines
I don't really know what to say or recommend here. Personally I think any
attempt to tie PWM values to RPM are doomed to fail. Here are a couple of
examples:Quoted 11 lines
Take your test system and move the fan to a restricted place (eg close to a
wall). You'll see the fan RPM change, potentially significantly. Put it into some place with airflow towards or away from the system (eg blow air into
the system from another place, which may happen if the system is installed
in a lab), and again you'll see fan speed changes. Open the chassis, and the fan speed will change. I have seen fan speeds vary by up to 50% when
changing airflow.Here we can at least control the tolerance for each PWM vs RPM point but I can image this as a very painful process to get these values right and no one will think in setting tolerances of 50%...
Quoted 5 lines
That doesn't even take into account that replacing a fan even with a similar
model (eg after a fan failed) will likely result in potentially significant rpm changes.
Quoted 8 lines
Quoted 3 lines
Ultimately, anything that does more than determine if a fan is still running
is potentially unstable.Yeah, I understand your points. The HW does the evaluation and of course it also looks for the presence of a signal... So, in your opinion, not even setting a minimum fan speed is likely to be stable?
Using the minimum fan speed as detection mechanism for fan failures is ok and widely used. My concern is the desire to associate it with pwm values.
Quoted 9 lines
Quoted 4 lines
Having said all that, it is really your call to decide how you want to detect
fan failures.Well, my hands are also tied here. The core is supposed to work without any SW interaction in which case the tacho evaluation is always done. The only thing I could do is to completely ignore fan faults which is also bad...
As I said above, it would be perfectly fine to have a parameter that reflects minimum fan speed (or, translated into chip speak, minimum number of pulses per minute).
Quoted 8 lines
I can try to persuade the HW guy to completely remove the evaluation and just give fan fauts in case there's no signal but I'm not really sure he will go for it. In that case, I'm tempted to just leave this as-is (with the extra bindings for the tolerance and turn these bindings into a map) if you're willing to take it... The reason is that, as you said, this is likely to be unstable any ways so that the added complexity in the SW does not really pay off (better keep at least the SW simple)...
Sure, I'll take it, as long as you find a binding that is acceptable for Rob. It is your funeral, after all :-).
Thanks,
Guenter
Nuno Sá
maintainerRFC PATCH 4/6 hwmon: axi-fan-control: handle irqs in natural order
In reply to Nuno SáThe core will now start out of reset at boot as soon as clocking is available. Hence, by the time we unmask the interrupts we already might have some of them set. Thus, it's important to handle them in the natural order the core generates them. Otherwise, we could process 'ADI_IRQ_SRC_PWM_CHANGED' before 'ADI_IRQ_SRC_TEMP_INCREASE' and erroneously set 'update_tacho_params' to true.
--- drivers/hwmon/axi-fan-control.c | 30 +++++++++++++++--------------- 1 file changed, 15 insertions(+), 15 deletions(-)
drivers/hwmon/axi-fan-control.c +15 -15
@@ -291,18 +291,9 @@ static irqreturn_t axi_fan_control_irq_handler(int irq, void *data)u32 irq_pending =axi_ioread (ADI_REG_IRQ_PENDING , ctl);u32 clear_mask; -if (irq_pending &ADI_IRQ_SRC_NEW_MEASUR ) { -if (ctl->update_tacho_params) { -u32 new_tach =axi_ioread (ADI_REG_TACH_MEASUR , ctl); - -/* get 25% tolerance */ -u32 tach_tol =DIV_ROUND_CLOSEST (new_tach *25 ,100 ); -/* set new tacho parameters */ -axi_iowrite (new_tach,ADI_REG_TACH_PERIOD , ctl); -axi_iowrite (tach_tol,ADI_REG_TACH_TOLERANCE , ctl); - ctl->update_tacho_params = false; - } - } +if (irq_pending &ADI_IRQ_SRC_TEMP_INCREASE ) +/* hardware requested a new pwm */ + ctl->hw_pwm_req = true;if (irq_pending &ADI_IRQ_SRC_PWM_CHANGED ) {/*
@@ -318,9 +309,18 @@ static irqreturn_t axi_fan_control_irq_handler(int irq, void *data) } } -if (irq_pending &ADI_IRQ_SRC_TEMP_INCREASE ) -/* hardware requested a new pwm */ - ctl->hw_pwm_req = true; +if (irq_pending &ADI_IRQ_SRC_NEW_MEASUR ) { +if (ctl->update_tacho_params) { +u32 new_tach =axi_ioread (ADI_REG_TACH_MEASUR , ctl); +/* get 25% tolerance */ +u32 tach_tol =DIV_ROUND_CLOSEST (new_tach *25 ,100 ); + +/* set new tacho parameters */ +axi_iowrite (new_tach,ADI_REG_TACH_PERIOD , ctl); +axi_iowrite (tach_tol,ADI_REG_TACH_TOLERANCE , ctl); + ctl->update_tacho_params = false; + } + }if (irq_pending &ADI_IRQ_SRC_TACH_ERR ) ctl->fan_fault =1 ;
Signature · 1 line
2.32.0
Nuno Sá
maintainerRFC PATCH 5/6 hwmon: axi-fan-control: clear the fan fault irq at startup
In reply to Nuno SáThe core might pull itself out of reset automatically which means it can run with invalid tacho evaluation parameters for some time. Thus, it will trigger a FAN FAULT interrupt as soon as we unmask it. Some userland apps might be sensitive to this and act drastically. Hence, we will clear it here and if there's something really wrong with the FAN or the evaluation parameters, we'll get that interrupt again...
--- drivers/hwmon/axi-fan-control.c | 9 +++++++++ 1 file changed, 9 insertions(+)
drivers/hwmon/axi-fan-control.c +9 -0
@@ -379,6 +379,15 @@ static int axi_fan_control_init(struct axi_fan_control_data *ctl, ADI_IRQ_SRC_PWM_CHANGED | ADI_IRQ_SRC_TEMP_INCREASE), ADI_REG_IRQ_MASK, ctl); +/* +* The core might pull itself out of reset automatically which means it can run with +* invalid tacho evaluation parameters for some time. Thus, it will trigger a FAN +* FAULT interrupt as soon as we unmask it(and some userland apps might be sensitive to +* this). Hence, we will clear it here and if there's something really wrong with the +* FAN or the evaluation parameters, we'll get that interrupt again... +*/ +axi_iowrite (ADI_IRQ_SRC_TACH_ERR ,ADI_REG_IRQ_PENDING , ctl); +/* bring the device out of reset */ axi_iowrite (0x01 ,ADI_REG_RSTN , ctl);
Signature · 1 line
2.32.0
Nuno Sá
maintainerRFC PATCH 6/6 hwmon: axi-fan-control: support temperature vs pwm points
In reply to Nuno SáThe HW has some predefined points where it will associate a PWM value. However some users might want to better set these points to their usecases. This patch exposes these points as pwm auto_points:
* pwm1_auto_point1_temp: temperature threshold below which PWM should be 0%;
* pwm1_auto_point2_temp: temperature threshold above which PWM should be 25%;
* pwm1_auto_point3_temp: temperature threshold below which PWM should be 25%;
* pwm1_auto_point4_temp: temperature threshold above which PWM should be 50%;
* pwm1_auto_point5_temp: temperature threshold below which PWM should be 50%;
* pwm1_auto_point6_temp: temperature threshold above which PWM should be 75%;
* pwm1_auto_point7_temp: temperature threshold below which PWM should be 75%;
* pwm1_auto_point8_temp: temperature threshold above which PWM should be 100%;
--- drivers/hwmon/axi-fan-control.c | 74 ++++++++++++++++++++++++++++++++- 1 file changed, 73 insertions(+), 1 deletion(-)
drivers/hwmon/axi-fan-control.c +73 -1
@@ -8,6 +8,7 @@#include <linux/clk.h> #include <linux/fpga/adi-axi-common.h> #include <linux/hwmon.h> +#include <linux/hwmon-sysfs.h> #include <linux/interrupt.h> #include <linux/io.h> #include <linux/kernel.h>
@@ -31,6 +32,14 @@#define ADI_REG_TACH_50_TOL 0x0154#define ADI_REG_TACH_75_TOL 0x0158#define ADI_REG_TACH_100_TOL 0x015c +#define ADI_REG_TEMP_00_H 0x0100 +#define ADI_REG_TEMP_25_L 0x0104 +#define ADI_REG_TEMP_25_H 0x0108 +#define ADI_REG_TEMP_50_L 0x010c +#define ADI_REG_TEMP_50_H 0x0110 +#define ADI_REG_TEMP_75_L 0x0114 +#define ADI_REG_TEMP_75_H 0x0118 +#define ADI_REG_TEMP_100_L 0x011c#define ADI_REG_IRQ_MASK 0x0040#define ADI_REG_IRQ_PENDING 0x0044
@@ -70,6 +79,39 @@ static inline u32 axi_ioread(const u32 reg,return ioread32 (ctl->base + reg); } +/* +* The core calculates the temperature as: +* T = /raw * 509.3140064 / 65535) - 280.2308787 +*/ +static ssize_t axi_fan_control_show (struct device *dev,struct device_attribute *da,char *buf) +{ +struct axi_fan_control_data *ctl =dev_get_drvdata (dev); +struct sensor_device_attribute *attr =to_sensor_dev_attr (da); +u32 temp =axi_ioread (attr->index, ctl); + + temp =DIV_ROUND_CLOSEST_ULL (temp *509314ULL ,65535 ) -280230 ; + +return sprintf (buf,"%u\n" , temp); +} + +static ssize_t axi_fan_control_store (struct device *dev,struct device_attribute *da, +const char *buf,size_t count) +{ +struct axi_fan_control_data *ctl =dev_get_drvdata (dev); +struct sensor_device_attribute *attr =to_sensor_dev_attr (da); +u32 temp; +int ret; + + ret =kstrtou32 (buf,10 , &temp); +if (ret) +return ret; + + temp =DIV_ROUND_CLOSEST_ULL ((temp +280230 ) *65535ULL ,509314 ); +axi_iowrite (temp, attr->index, ctl); + +return count; +} +static long axi_fan_control_get_pwm_duty (const struct axi_fan_control_data *ctl) {u32 pwm_width =axi_ioread (ADI_REG_PWM_WIDTH , ctl);
@@ -418,6 +460,36 @@ static const struct hwmon_chip_info axi_chip_info = { .info = axi_fan_control_info, }; +/* temperature threshold below which PWM should be 0% */ +static SENSOR_DEVICE_ATTR_RW(pwm1_auto_point1_temp, axi_fan_control, ADI_REG_TEMP_00_H); +/* temperature threshold above which PWM should be 25% */ +static SENSOR_DEVICE_ATTR_RW(pwm1_auto_point2_temp, axi_fan_control, ADI_REG_TEMP_25_L); +/* temperature threshold below which PWM should be 25% */ +static SENSOR_DEVICE_ATTR_RW(pwm1_auto_point3_temp, axi_fan_control, ADI_REG_TEMP_25_H); +/* temperature threshold above which PWM should be 50% */ +static SENSOR_DEVICE_ATTR_RW(pwm1_auto_point4_temp, axi_fan_control, ADI_REG_TEMP_50_L); +/* temperature threshold below which PWM should be 50% */ +static SENSOR_DEVICE_ATTR_RW(pwm1_auto_point5_temp, axi_fan_control, ADI_REG_TEMP_50_H); +/* temperature threshold above which PWM should be 75% */ +static SENSOR_DEVICE_ATTR_RW(pwm1_auto_point6_temp, axi_fan_control, ADI_REG_TEMP_75_L); +/* temperature threshold below which PWM should be 75% */ +static SENSOR_DEVICE_ATTR_RW(pwm1_auto_point7_temp, axi_fan_control, ADI_REG_TEMP_75_H); +/* temperature threshold above which PWM should be 100% */ +static SENSOR_DEVICE_ATTR_RW(pwm1_auto_point8_temp, axi_fan_control, ADI_REG_TEMP_100_L); + +static struct attribute *axi_fan_control_attrs[] = { + &sensor_dev_attr_pwm1_auto_point1_temp.dev_attr.attr, + &sensor_dev_attr_pwm1_auto_point2_temp.dev_attr.attr, + &sensor_dev_attr_pwm1_auto_point3_temp.dev_attr.attr, + &sensor_dev_attr_pwm1_auto_point4_temp.dev_attr.attr, + &sensor_dev_attr_pwm1_auto_point5_temp.dev_attr.attr, + &sensor_dev_attr_pwm1_auto_point6_temp.dev_attr.attr, + &sensor_dev_attr_pwm1_auto_point7_temp.dev_attr.attr, + &sensor_dev_attr_pwm1_auto_point8_temp.dev_attr.attr, +NULL , +}; +ATTRIBUTE_GROUPS (axi_fan_control); +static const u32 version_1_0_0 =ADI_AXI_PCORE_VER (1 ,0 ,'a' );static const struct of_device_id axi_fan_control_of_match[] = {
@@ -502,7 +574,7 @@ static int axi_fan_control_probe(struct platform_device *pdev) name, ctl, &axi_chip_info, - NULL); + axi_fan_control_groups);return PTR_ERR_OR_ZERO (ctl->hdev); }
Signature · 1 line
2.32.0
Guenter Roeck
maintainerRe: [RFC PATCH 6/6] hwmon: axi-fan-control: support temperature vs pwm points
Quoted 4 lines · Nuno Sá
The HW has some predefined points where it will associate a PWM value. However some users might want to better set these points to their usecases. This patch exposes these points as pwm
auto_points:
Quoted 17 lines
*
pwm1_auto_point1_temp: temperature threshold below which PWM should be 0%;
*pwm1_auto_point2_temp: temperature threshold above which PWM should be 25%;
*pwm1_auto_point3_temp: temperature threshold below which PWM should be 25%;
*pwm1_auto_point4_temp: temperature threshold above which PWM should be 50%;
*pwm1_auto_point5_temp: temperature threshold below which PWM should be 50%;
*pwm1_auto_point6_temp: temperature threshold above which PWM should be 75%;
*pwm1_auto_point7_temp: temperature threshold below which PWM should be 75%;
*pwm1_auto_point8_temp: temperature threshold above which PWM should be 100%;
If I understand those correctly, half of those are really hysteresis points. I think it would be better to express this with
pwm1_auto_pointX_temp
pwm1_auto_pointX_temp_hyst
where the hysteresis point is the temperature where the previous pwm value is activated. In other words, change attribute names as follows:
for 25%:
pwm1_auto_point1_temp -> pwm1_auto_point1_temp_hyst
pwm1_auto_point2_temp -> pwm1_auto_point1_temp
for 50%:
pwm1_auto_point3_temp -> pwm1_auto_point2_temp_hyst
pwm1_auto_point4_temp -> pwm1_auto_point2_temp
for 75%:
pwm1_auto_point5_temp -> pwm1_auto_point3_temp_hyst
pwm1_auto_point6_temp -> pwm1_auto_point3_temp
for 100%:
pwm1_auto_point7_temp -> pwm1_auto_point4_temp_hyst
pwm1_auto_point8_temp -> pwm1_auto_point4_tempThanks,
Guenter
Sa, Nuno
maintainerRE: [RFC PATCH 6/6] hwmon: axi-fan-control: support temperature vs pwm points
Quoted 52 lines
From: Guenter Roeck <[email protected]> On Behalf Of Guenter Roeck
Sent: Saturday, July 17, 2021 7:23 PM
To: Sa, Nuno <[email protected]>
Cc: [email protected]; [email protected]; Rob Herring <[email protected]>; Jean Delvare <[email protected]>
Subject: Re: [RFC PATCH 6/6] hwmon: axi-fan-control: support temperature vs pwm points[External]
Quoted 1 line · Nuno Sá
The HW has some predefined points where it will associate a PWM
value.
Quoted 4 lines
However some users might want to better set these points to their usecases. This patch exposes these points as pwm
auto_points:*
pwm1_auto_point1_temp: temperature threshold below whichPWM should be
Quoted 2 lines
0%;*
pwm1_auto_point2_temp: temperature threshold above whichPWM should be
Quoted 2 lines
25%;*
pwm1_auto_point3_temp: temperature threshold below whichPWM should be
Quoted 2 lines
25%;*
pwm1_auto_point4_temp: temperature threshold above whichPWM should be
Quoted 2 lines
50%;*
pwm1_auto_point5_temp: temperature threshold below whichPWM should be
Quoted 2 lines
50%;*
pwm1_auto_point6_temp: temperature threshold above whichPWM should be
Quoted 2 lines
75%;*
pwm1_auto_point7_temp: temperature threshold below whichPWM should be
Quoted 2 lines
75%;*
pwm1_auto_point8_temp: temperature threshold above whichPWM should be
Quoted 2 lines
100%;If I understand those correctly, half of those are really hysteresis points.
I think it would be better to express this with
pwm1_auto_pointX_temp
pwm1_auto_pointX_temp_hystwhere the hysteresis point is the temperature where the previous pwm value
is activated. In other words, change attribute names as follows:
Quoted 13 lines
for 25%:
pwm1_auto_point1_temp -> pwm1_auto_point1_temp_hyst
pwm1_auto_point2_temp -> pwm1_auto_point1_temp
for 50%:
pwm1_auto_point3_temp -> pwm1_auto_point2_temp_hyst
pwm1_auto_point4_temp -> pwm1_auto_point2_temp
for 75%:
pwm1_auto_point5_temp -> pwm1_auto_point3_temp_hyst
pwm1_auto_point6_temp -> pwm1_auto_point3_temp
for 100%:
pwm1_auto_point7_temp -> pwm1_auto_point4_temp_hyst
pwm1_auto_point8_temp -> pwm1_auto_point4_tempAgree, it makes sense.
- Nuno Sá
Sa, Nuno
maintainerHi Guenter,
Quoted 40 lines
From: Nuno Sá <[email protected]>
Sent: Thursday, July 8, 2021 2:01 PM
To: [email protected]; [email protected]
Cc: Guenter Roeck <[email protected]>; Rob Herring <[email protected]>; Jean Delvare <[email protected]>
Subject: [RFC PATCH 0/6] AXI FAN new features and improvementsThis series adds some new features to the axi-fan-control driver. On top
of that, the HW had some changes (basically it now starts automatically out of reset) so that the driver needed some minor refactoring. The reason I'm sending this as RFC, is mainly because of the last patch ("hwmon: axi-fan-control: support temperature vs pwm points"). The core
has some predefined values which define a temperature vs pwm curve [1].
It also exposes registers so that users can change it according to their needs. As I could not find standard attributes in the subsystem, I'm proposing some "raw" sysfs files. Looking at [2], thepwm_auto_pointstuff looked to be what I want. Obviously I might be wrong :). If this is accepted, I will add a proper sysfs DOC file describing the new files (being lazy in the RFC).For patch 5 ("hwmon: axi-fan-control: clear the fan fault irq at startup"),
it's also arguable if we really need it. The main reason I have it is because of some userland apps that might take some drastic measures by
just reading 1fan_faultalarm. Obviously, we can argue that the problem
is in the app and not in the driver. Though it's such a minimal change that I decided to include it (I'm more than fine in dropping the patch).[1]: https://wiki.analog.com/resources/fpga/docs/axi_fan_control
[2]:
https://urldefense.com/v3/__https://www.kernel.org/doc/Documen
tation/hwmon/sysfs- interface__;!!A3Ni8CS0y2Y!uwjpaOT8QEBVfKTCWELJNbjJJ69iR7S3tKS WV4B0K742CtcARkTtAqMxknnpPw$
Quoted 8 lines
Nuno Sá (6):
hwmon: axi-fan-control: make sure the clock is enabled
hwmon: axi-fan-control: add tacho devicetree properties
dt-bindings: axi-fan-control: add tacho properties
hwmon: axi-fan-control: handle irqs in natural order
hwmon: axi-fan-control: clear the fan fault irq at startup
hwmon: axi-fan-control: support temperature vs pwm points
The HW guy is willing to change how the core works. This means, that all that unstable pwm - rpm points will go away and we will have a register where we can set the minimum fan speed for evaluating the FAN. He also said that the default value for the this setting will be pretty low so that we should only have _real_ faults at startup which means patch 5 should not be needed anymore...
Anyways, I will send a new pull with patches 1,3 and 5 and as soon as I have some HW ready to test, I will send the other patches. With the new mechanism, we can also simplify the IRQ handling [1]...
For the new devicetree property, I think now it really is a fan property which makes me wonder if the property will be accepted in the controller bindings or if I need to send a fan.yaml...
[1]: https://elixir.bootlin.com/linux/v5.14-rc3/source/drivers/hwmon/axi-fan-control.c#L280
- Nuno Sá
Guenter Roeck
maintainerHi,
Quoted 60 lines · Nuno
Hi Guenter,
Quoted 40 lines
From: Nuno Sá <[email protected]>
Sent: Thursday, July 8, 2021 2:01 PM
To: [email protected]; [email protected]
Cc: Guenter Roeck <[email protected]>; Rob Herring <[email protected]>; Jean Delvare <[email protected]>
Subject: [RFC PATCH 0/6] AXI FAN new features and improvementsThis series adds some new features to the axi-fan-control driver. On top
of that, the HW had some changes (basically it now starts automatically out of reset) so that the driver needed some minor refactoring. The reason I'm sending this as RFC, is mainly because of the last patch ("hwmon: axi-fan-control: support temperature vs pwm points"). The core
has some predefined values which define a temperature vs pwm curve [1].
It also exposes registers so that users can change it according to their needs. As I could not find standard attributes in the subsystem, I'm proposing some "raw" sysfs files. Looking at [2], thepwm_auto_pointstuff looked to be what I want. Obviously I might be wrong :). If this is accepted, I will add a proper sysfs DOC file describing the new files (being lazy in the RFC).For patch 5 ("hwmon: axi-fan-control: clear the fan fault irq at startup"),
it's also arguable if we really need it. The main reason I have it is because of some userland apps that might take some drastic measures by
just reading 1fan_faultalarm. Obviously, we can argue that the problem
is in the app and not in the driver. Though it's such a minimal change that I decided to include it (I'm more than fine in dropping the patch).[1]: https://wiki.analog.com/resources/fpga/docs/axi_fan_control
[2]:
https://urldefense.com/v3/__https://www.kernel.org/doc/Documen
tation/hwmon/sysfs- interface__;!!A3Ni8CS0y2Y!uwjpaOT8QEBVfKTCWELJNbjJJ69iR7S3tKS WV4B0K742CtcARkTtAqMxknnpPw$Quoted 8 lines
Nuno Sá (6):
hwmon: axi-fan-control: make sure the clock is enabled
hwmon: axi-fan-control: add tacho devicetree properties
dt-bindings: axi-fan-control: add tacho properties
hwmon: axi-fan-control: handle irqs in natural order
hwmon: axi-fan-control: clear the fan fault irq at startup
hwmon: axi-fan-control: support temperature vs pwm pointsThe HW guy is willing to change how the core works. This means, that all that unstable pwm - rpm points will go away and we will have a register where we can set the minimum fan speed for evaluating the FAN. He also said that the default value for the this setting will be pretty low so that we should only have _real_ faults at startup which means patch 5 should not be needed anymore...
Quoted 1 line
Anyways, I will send a new pull with patches 1,3 and 5 and
That kind of contradicts what you say above, that patch 5 won't be needed anymore. Am I missing something ?
Quoted 8 lines
as soon as I have some HW ready to test, I will send the other patches. With the new mechanism, we can also simplify the IRQ handling [1]...
For the new devicetree property, I think now it really is a fan property which makes me wonder if the property will be accepted in the controller bindings or if I need to send a
fan.yaml...
Not really sure myself. At he very least we'll have sysfs properties, so the minimum speed could also be updated from userspace. Ultimately we'll need some set of devicetree properties, not only for fans but for pretty much everything supported by hwmon, but I have no idea what is acceptable and what isn't - if I did I might have proposed something by now.
Guenter
Sa, Nuno
maintainerQuoted 88 lines
-----Original Message-----
From: Guenter Roeck <[email protected]> On Behalf Of Guenter Roeck
Sent: Wednesday, July 28, 2021 8:38 PM
To: Sa, Nuno <[email protected]>; [email protected]; [email protected]
Cc: Rob Herring <[email protected]>; Jean Delvare <[email protected]>
Subject: Re: [RFC PATCH 0/6] AXI FAN new features and improvements[External]
Hi,
Quoted 11 lines · Nuno
Hi Guenter,
Quoted 8 lines
From: Nuno Sá <[email protected]>
Sent: Thursday, July 8, 2021 2:01 PM
To: [email protected]; [email protected]
Cc: Guenter Roeck <[email protected]>; Rob Herring <[email protected]>; Jean Delvare <[email protected]>
Subject: [RFC PATCH 0/6] AXI FAN new features and improvementsThis series adds some new features to the axi-fan-control driver.
On
Quoted 2 lines
Quoted 2 lines
top
of that, the HW had some changes (basically it now startsautomatically
Quoted 3 lines
Quoted 3 lines
out of reset) so that the driver needed some minor refactoring. The reason I'm sending this as RFC, is mainly because of the last patch ("hwmon: axi-fan-control: support temperature vs pwm points").
The
Quoted 4 lines
Quoted 4 lines
core
has some predefined values which define a temperature vs pwm curve [1].
It also exposes registers so that users can change it according totheir
Quoted 2 lines
Quoted 2 lines
needs. As I could not find standard attributes in the subsystem, I'm proposing some "raw" sysfs files. Looking at [2], the
pwm_auto_pointQuoted 2 lines
Quoted 2 lines
stuff looked to be what I want. Obviously I might be wrong :). If this is accepted, I will add a proper sysfs DOC file describing the new
files
Quoted 6 lines
Quoted 6 lines
(being lazy in the RFC).
For patch 5 ("hwmon: axi-fan-control: clear the fan fault irq at startup"),
it's also arguable if we really need it. The main reason I have it is because of some userland apps that might take some drasticmeasures
Quoted 5 lines
Quoted 5 lines
by
just reading 1fan_faultalarm. Obviously, we can argue that the problem
is in the app and not in the driver. Though it's such a minimal change that I decided to include it (I'm more than fine in dropping thepatch).
Quoted 4 lines
Quoted 4 lines
[1]: https://wiki.analog.com/resources/fpga/docs/axi_fan_control
[2]:https://urldefense.com/v3/__https://www.kernel.org/doc/Documen
Quoted 2 lines
Quoted 2 lines
tation/hwmon/sysfs-
interface__;!!A3Ni8CS0y2Y!uwjpaOT8QEBVfKTCWELJNbjJJ69iR7S3tKS
Quoted 19 lines
Quoted 10 lines
WV4B0K742CtcARkTtAqMxknnpPw$
Nuno Sá (6):
hwmon: axi-fan-control: make sure the clock is enabled
hwmon: axi-fan-control: add tacho devicetree properties
dt-bindings: axi-fan-control: add tacho properties
hwmon: axi-fan-control: handle irqs in natural order
hwmon: axi-fan-control: clear the fan fault irq at startup
hwmon: axi-fan-control: support temperature vs pwm pointsThe HW guy is willing to change how the core works. This means, that all that unstable pwm - rpm points will go away and we will have a register where we can set the minimum fan speed for evaluating the FAN. He also said that the default value for the this setting will be pretty low so that we should only have _real_ faults at startup which means patch 5 should not be needed anymore...
Quoted 4 lines
Quoted 1 line
Anyways, I will send a new pull with patches 1,3 and 5 and
That kind of contradicts what you say above, that patch 5 won't be needed anymore. Am I missing something ?
My bad... I meant patch 6 and not 5.
- Nuno Sá