clk: qcom: gcc: Update the SDCC RCGs to use shared_floor_ops
Subsystems (3)
v2 cover clk: qcom: gcc: Update the SDCC RCGs to use shared_floor_ops
This series updates the clock ops to clk_rcg2_shared_floor_ops for the SDCC RCGs on SM8450, SM8750, SM4450, SDX75, Milos, X1E80100, QDU1000 and GLYMUR chipsets.
This change is required to ensure RCG is safely parked during disable and new parent configuration is programmed in hardware only when new parent is enabled, to avoid cases where RCG configuration fails to update and overclocking issues.
---
Changes in v2:
- Added patches 6,7,8 to use shared_floor_ops for SDCC RCGs on X1E80100,
QDU1000 and GLYMUR chipsets also.
- picked the R-By tags received on v1.
- Link to v1: https://lore.kernel.org/r/20251126-sdcc_shared_floor_ops-v1-0-9038430dfed4@oss.qualcomm.com
---
Jagadeesh Kona (8):
clk: qcom: gcc-sm8450: Update the SDCC RCGs to use shared_floor_ops
clk: qcom: gcc-sm8750: Update the SDCC RCGs to use shared_floor_ops
clk: qcom: gcc-sm4450: Update the SDCC RCGs to use shared_floor_ops
clk: qcom: gcc-sdx75: Update the SDCC RCGs to use shared_floor_ops
clk: qcom: gcc-milos: Update the SDCC RCGs to use shared_floor_ops
clk: qcom: gcc-x1e80100: Update the SDCC RCGs to use shared_floor_ops
clk: qcom: gcc-qdu1000: Update the SDCC RCGs to use shared_floor_ops
clk: qcom: gcc-glymur: Update the SDCC RCGs to use shared_floor_ops
drivers/clk/qcom/gcc-glymur.c | 4 ++-- drivers/clk/qcom/gcc-milos.c | 6 +++--- drivers/clk/qcom/gcc-qdu1000.c | 4 ++-- drivers/clk/qcom/gcc-sdx75.c | 4 ++-- drivers/clk/qcom/gcc-sm4450.c | 6 +++--- drivers/clk/qcom/gcc-sm8450.c | 4 ++-- drivers/clk/qcom/gcc-sm8750.c | 4 ++-- drivers/clk/qcom/gcc-x1e80100.c | 4 ++-- 8 files changed, 18 insertions(+), 18 deletions(-)
---
base-commit: 92fd6e84175befa1775e5c0ab682938eca27c0b2
change-id: 20251125-sdcc_shared_floor_ops-722ccecfe787
Best regards,
Signature · 1 line
Jagadeesh Kona <[email protected]>
PATCH v2 1/8 clk: qcom: gcc-sm8450: Update the SDCC RCGs to use shared_floor_ops
Use shared_floor_ops for the SDCC RCGs so the RCG is safely parked during disable and the new parent configuration is programmed in hardware only when the new parent is enabled, avoiding cases where the RCG configuration fails to update.
--- drivers/clk/qcom/gcc-sm8450.c | 4 ++-- 1 file changed, 2 insertions(+), 2 deletions(-)
drivers/clk/qcom/gcc-sm8450.c +2 -2
@@ -1034,7 +1034,7 @@ static struct clk_rcg2 gcc_sdcc2_apps_clk_src = { .parent_data = gcc_parent_data_7, .num_parents = ARRAY_SIZE(gcc_parent_data_7), .flags = CLK_SET_RATE_PARENT, - .ops = &clk_rcg2_floor_ops, + .ops = &clk_rcg2_shared_floor_ops, }, };
@@ -1057,7 +1057,7 @@ static struct clk_rcg2 gcc_sdcc4_apps_clk_src = { .parent_data = gcc_parent_data_0, .num_parents = ARRAY_SIZE(gcc_parent_data_0), .flags = CLK_SET_RATE_PARENT, - .ops = &clk_rcg2_floor_ops, + .ops = &clk_rcg2_shared_floor_ops, }, };
Signature · 1 line
2.34.1
PATCH v2 2/8 clk: qcom: gcc-sm8750: Update the SDCC RCGs to use shared_floor_ops
In reply to Jagadeesh KonaUse shared_floor_ops for the SDCC RCGs so the RCG is safely parked during disable and the new parent configuration is programmed in hardware only when the new parent is enabled, avoiding cases where the RCG configuration fails to update.
--- drivers/clk/qcom/gcc-sm8750.c | 4 ++-- 1 file changed, 2 insertions(+), 2 deletions(-)
drivers/clk/qcom/gcc-sm8750.c +2 -2
@@ -1030,7 +1030,7 @@ static struct clk_rcg2 gcc_sdcc2_apps_clk_src = { .parent_data = gcc_parent_data_8, .num_parents = ARRAY_SIZE(gcc_parent_data_8), .flags = CLK_SET_RATE_PARENT, - .ops = &clk_rcg2_floor_ops, + .ops = &clk_rcg2_shared_floor_ops, }, };
@@ -1052,7 +1052,7 @@ static struct clk_rcg2 gcc_sdcc4_apps_clk_src = { .parent_data = gcc_parent_data_0, .num_parents = ARRAY_SIZE(gcc_parent_data_0), .flags = CLK_SET_RATE_PARENT, - .ops = &clk_rcg2_floor_ops, + .ops = &clk_rcg2_shared_floor_ops, }, };
Signature · 1 line
2.34.1
PATCH v2 3/8 clk: qcom: gcc-sm4450: Update the SDCC RCGs to use shared_floor_ops
In reply to Jagadeesh KonaUse shared_floor_ops for the SDCC RCGs so the RCG is safely parked during disable and the new parent configuration is programmed in hardware only when the new parent is enabled, avoiding cases where the RCG configuration fails to update.
--- drivers/clk/qcom/gcc-sm4450.c | 6 +++--- 1 file changed, 3 insertions(+), 3 deletions(-)
drivers/clk/qcom/gcc-sm4450.c +3 -3
@@ -769,7 +769,7 @@ static struct clk_rcg2 gcc_sdcc1_apps_clk_src = { .parent_data = gcc_parent_data_4, .num_parents = ARRAY_SIZE(gcc_parent_data_4), .flags = CLK_SET_RATE_PARENT, - .ops = &clk_rcg2_floor_ops, + .ops = &clk_rcg2_shared_floor_ops, }, };
@@ -791,7 +791,7 @@ static struct clk_rcg2 gcc_sdcc1_ice_core_clk_src = { .parent_data = gcc_parent_data_4, .num_parents = ARRAY_SIZE(gcc_parent_data_4), .flags = CLK_SET_RATE_PARENT, - .ops = &clk_rcg2_floor_ops, + .ops = &clk_rcg2_shared_floor_ops, }, };
@@ -815,7 +815,7 @@ static struct clk_rcg2 gcc_sdcc2_apps_clk_src = { .parent_data = gcc_parent_data_6, .num_parents = ARRAY_SIZE(gcc_parent_data_6), .flags = CLK_SET_RATE_PARENT, - .ops = &clk_rcg2_floor_ops, + .ops = &clk_rcg2_shared_floor_ops, }, };
Signature · 1 line
2.34.1
PATCH v2 4/8 clk: qcom: gcc-sdx75: Update the SDCC RCGs to use shared_floor_ops
In reply to Jagadeesh KonaUse shared_floor_ops for the SDCC RCGs so the RCG is safely parked during disable and the new parent configuration is programmed in hardware only when the new parent is enabled, avoiding cases where the RCG configuration fails to update.
--- drivers/clk/qcom/gcc-sdx75.c | 4 ++-- 1 file changed, 2 insertions(+), 2 deletions(-)
drivers/clk/qcom/gcc-sdx75.c +2 -2
@@ -1033,7 +1033,7 @@ static struct clk_rcg2 gcc_sdcc1_apps_clk_src = { .name = "gcc_sdcc1_apps_clk_src", .parent_data = gcc_parent_data_17, .num_parents = ARRAY_SIZE(gcc_parent_data_17), - .ops = &clk_rcg2_floor_ops, + .ops = &clk_rcg2_shared_floor_ops, }, };
@@ -1057,7 +1057,7 @@ static struct clk_rcg2 gcc_sdcc2_apps_clk_src = { .name = "gcc_sdcc2_apps_clk_src", .parent_data = gcc_parent_data_18, .num_parents = ARRAY_SIZE(gcc_parent_data_18), - .ops = &clk_rcg2_floor_ops, + .ops = &clk_rcg2_shared_floor_ops, }, };
Signature · 1 line
2.34.1
PATCH v2 5/8 clk: qcom: gcc-milos: Update the SDCC RCGs to use shared_floor_ops
In reply to Jagadeesh KonaUse shared_floor_ops for the SDCC RCGs to avoid any overclocking issues in SDCC usecases.
--- drivers/clk/qcom/gcc-milos.c | 6 +++--- 1 file changed, 3 insertions(+), 3 deletions(-)
drivers/clk/qcom/gcc-milos.c +3 -3
@@ -917,7 +917,7 @@ static struct clk_rcg2 gcc_sdcc1_apps_clk_src = { .name = "gcc_sdcc1_apps_clk_src", .parent_data = gcc_parent_data_9, .num_parents = ARRAY_SIZE(gcc_parent_data_9), - .ops = &clk_rcg2_shared_ops, + .ops = &clk_rcg2_shared_floor_ops, }, };
@@ -938,7 +938,7 @@ static struct clk_rcg2 gcc_sdcc1_ice_core_clk_src = { .name = "gcc_sdcc1_ice_core_clk_src", .parent_data = gcc_parent_data_10, .num_parents = ARRAY_SIZE(gcc_parent_data_10), - .ops = &clk_rcg2_shared_ops, + .ops = &clk_rcg2_shared_floor_ops, }, };
@@ -962,7 +962,7 @@ static struct clk_rcg2 gcc_sdcc2_apps_clk_src = { .name = "gcc_sdcc2_apps_clk_src", .parent_data = gcc_parent_data_11, .num_parents = ARRAY_SIZE(gcc_parent_data_11), - .ops = &clk_rcg2_shared_ops, + .ops = &clk_rcg2_shared_floor_ops, }, };
Signature · 1 line
2.34.1
PATCH v2 6/8 clk: qcom: gcc-x1e80100: Update the SDCC RCGs to use shared_floor_ops
In reply to Jagadeesh KonaUse shared_floor_ops for the SDCC RCGs so the RCG is safely parked during disable and the new parent configuration is programmed in hardware only when the new parent is enabled, avoiding cases where the RCG configuration fails to update.
--- drivers/clk/qcom/gcc-x1e80100.c | 4 ++-- 1 file changed, 2 insertions(+), 2 deletions(-)
drivers/clk/qcom/gcc-x1e80100.c +2 -2
@@ -1516,7 +1516,7 @@ static struct clk_rcg2 gcc_sdcc2_apps_clk_src = { .parent_data = gcc_parent_data_9, .num_parents = ARRAY_SIZE(gcc_parent_data_9), .flags = CLK_SET_RATE_PARENT, - .ops = &clk_rcg2_floor_ops, + .ops = &clk_rcg2_shared_floor_ops, }, };
@@ -1538,7 +1538,7 @@ static struct clk_rcg2 gcc_sdcc4_apps_clk_src = { .parent_data = gcc_parent_data_0, .num_parents = ARRAY_SIZE(gcc_parent_data_0), .flags = CLK_SET_RATE_PARENT, - .ops = &clk_rcg2_floor_ops, + .ops = &clk_rcg2_shared_floor_ops, }, };
Signature · 1 line
2.34.1
Re: [PATCH v2 6/8] clk: qcom: gcc-x1e80100: Update the SDCC RCGs to use shared_floor_ops
Quoted 7 lines · Jagadeesh Kona
Use
shared_floor_opsfor the SDCC RCGs so the RCG is safely parked during disable and the new parent configuration is programmed in hardware only when the new parent is enabled, avoiding cases where the RCG configuration fails to update.Fixes 161b7c401f4b ("clk: qcom: Add Global Clock controller (GCC) driver for X1E80100")Signed-off-by Jagadeesh Kona <[email protected]>
Signature · 2 lines
Best wishes, Vladimir
Re: [PATCH v2 6/8] clk: qcom: gcc-x1e80100: Update the SDCC RCGs to use shared_floor_ops
In reply to Jagadeesh KonaQuoted 11 lines · Jagadeesh Kona
Use
shared_floor_opsfor the SDCC RCGs so the RCG is safely parked during disable and the new parent configuration is programmed in hardware only when the new parent is enabled, avoiding cases where the RCG configuration fails to update.Fixes 161b7c401f4b ("clk: qcom: Add Global Clock controller (GCC) driver for X1E80100")Signed-off-by Jagadeesh Kona <[email protected]>--- drivers/clk/qcom/gcc-x1e80100.c | 4 ++-- 1 file changed, 2 insertions(+), 2 deletions(-)
Thanks,
Imran
PATCH v2 7/8 clk: qcom: gcc-qdu1000: Update the SDCC RCGs to use shared_floor_ops
In reply to Jagadeesh KonaUse shared_floor_ops for the SDCC RCGs so the RCG is safely parked during disable and the new parent configuration is programmed in hardware only when the new parent is enabled, avoiding cases where the RCG configuration fails to update.
--- drivers/clk/qcom/gcc-qdu1000.c | 4 ++-- 1 file changed, 2 insertions(+), 2 deletions(-)
drivers/clk/qcom/gcc-qdu1000.c +2 -2
@@ -904,7 +904,7 @@ static struct clk_rcg2 gcc_sdcc5_apps_clk_src = { .name = "gcc_sdcc5_apps_clk_src", .parent_data = gcc_parent_data_8, .num_parents = ARRAY_SIZE(gcc_parent_data_8), - .ops = &clk_rcg2_floor_ops, + .ops = &clk_rcg2_shared_floor_ops, }, };
@@ -923,7 +923,7 @@ static struct clk_rcg2 gcc_sdcc5_ice_core_clk_src = { .name = "gcc_sdcc5_ice_core_clk_src", .parent_data = gcc_parent_data_2, .num_parents = ARRAY_SIZE(gcc_parent_data_2), - .ops = &clk_rcg2_floor_ops, + .ops = &clk_rcg2_shared_floor_ops, }, };
Signature · 1 line
2.34.1
Re: [PATCH v2 7/8] clk: qcom: gcc-qdu1000: Update the SDCC RCGs to use shared_floor_ops
Quoted 7 lines · Jagadeesh Kona
Use
shared_floor_opsfor the SDCC RCGs so the RCG is safely parked during disable and the new parent configuration is programmed in hardware only when the new parent is enabled, avoiding cases where the RCG configuration fails to update.Fixes baa316580013 ("clk: qcom: gcc-qdu1000: Update the SDCC clock RCG ops")Signed-off-by Jagadeesh Kona <[email protected]>
Signature · 2 lines
Best wishes, Vladimir
Re: [PATCH v2 7/8] clk: qcom: gcc-qdu1000: Update the SDCC RCGs to use shared_floor_ops
In reply to Jagadeesh KonaQuoted 26 lines · Jagadeesh Kona
Use
shared_floor_opsfor the SDCC RCGs so the RCG is safely parked during disable and the new parent configuration is programmed in hardware only when the new parent is enabled, avoiding cases where the RCG configuration fails to update.Fixes baa316580013 ("clk: qcom: gcc-qdu1000: Update the SDCC clock RCG ops")Signed-off-by Jagadeesh Kona <[email protected]>--- drivers/clk/qcom/gcc-qdu1000.c | 4 ++-- 1 file changed, 2 insertions(+), 2 deletions(-)drivers/clk/qcom/gcc-qdu1000.c +1
-1@@ -904,7 +904,7 @@ static struct clk_rcg2 gcc_sdcc5_apps_clk_src = { .name = "gcc_sdcc5_apps_clk_src", .parent_data = gcc_parent_data_8, .num_parents = ARRAY_SIZE(gcc_parent_data_8), - .ops = &clk_rcg2_floor_ops, + .ops = &clk_rcg2_shared_floor_ops, }, };
drivers/clk/qcom/gcc-qdu1000.c static struct clk_rcg2 gcc_sdcc5_ice_core_clk_src = { · line 929
Quoted 8 lines
drivers/clk/qcom/gcc-qdu1000.c +1
-1@@ -923,7 +923,7 @@ static struct clk_rcg2 gcc_sdcc5_ice_core_clk_src = { .name = "gcc_sdcc5_ice_core_clk_src", .parent_data = gcc_parent_data_2, .num_parents = ARRAY_SIZE(gcc_parent_data_2), - .ops = &clk_rcg2_floor_ops, + .ops = &clk_rcg2_shared_floor_ops, }, };
Signature · 2 lines
Thanks, Taniya Das
Re: [PATCH v2 7/8] clk: qcom: gcc-qdu1000: Update the SDCC RCGs to use shared_floor_ops
In reply to Jagadeesh KonaQuoted 11 lines · Jagadeesh Kona
Use
shared_floor_opsfor the SDCC RCGs so the RCG is safely parked during disable and the new parent configuration is programmed in hardware only when the new parent is enabled, avoiding cases where the RCG configuration fails to update.Fixes baa316580013 ("clk: qcom: gcc-qdu1000: Update the SDCC clock RCG ops")Signed-off-by Jagadeesh Kona <[email protected]>--- drivers/clk/qcom/gcc-qdu1000.c | 4 ++-- 1 file changed, 2 insertions(+), 2 deletions(-)
Thanks,
Imran
PATCH v2 8/8 clk: qcom: gcc-glymur: Update the SDCC RCGs to use shared_floor_ops
In reply to Jagadeesh KonaUse shared_floor_ops for the SDCC RCGs so the RCG is safely parked during disable and the new parent configuration is programmed in hardware only when the new parent is enabled, avoiding cases where the RCG configuration fails to update.
--- drivers/clk/qcom/gcc-glymur.c | 4 ++-- 1 file changed, 2 insertions(+), 2 deletions(-)
drivers/clk/qcom/gcc-glymur.c +2 -2
@@ -2317,7 +2317,7 @@ static struct clk_rcg2 gcc_sdcc2_apps_clk_src = { .parent_data = gcc_parent_data_17, .num_parents = ARRAY_SIZE(gcc_parent_data_17), .flags = CLK_SET_RATE_PARENT, - .ops = &clk_rcg2_floor_ops, + .ops = &clk_rcg2_shared_floor_ops, }, };
@@ -2339,7 +2339,7 @@ static struct clk_rcg2 gcc_sdcc4_apps_clk_src = { .parent_data = gcc_parent_data_3, .num_parents = ARRAY_SIZE(gcc_parent_data_3), .flags = CLK_SET_RATE_PARENT, - .ops = &clk_rcg2_floor_ops, + .ops = &clk_rcg2_shared_floor_ops, }, };
Signature · 1 line
2.34.1
Re: [PATCH v2 8/8] clk: qcom: gcc-glymur: Update the SDCC RCGs to use shared_floor_ops
Quoted 7 lines · Jagadeesh Kona
Use
shared_floor_opsfor the SDCC RCGs so the RCG is safely parked during disable and the new parent configuration is programmed in hardware only when the new parent is enabled, avoiding cases where the RCG configuration fails to update.Fixes efe504300a17 ("clk: qcom: gcc: Add support for Global Clock Controller")Signed-off-by Jagadeesh Kona <[email protected]>
Signature · 2 lines
Best wishes, Vladimir
Re: [PATCH v2 8/8] clk: qcom: gcc-glymur: Update the SDCC RCGs to use shared_floor_ops
In reply to Jagadeesh KonaQuoted 26 lines · Jagadeesh Kona
Use
shared_floor_opsfor the SDCC RCGs so the RCG is safely parked during disable and the new parent configuration is programmed in hardware only when the new parent is enabled, avoiding cases where the RCG configuration fails to update.Fixes efe504300a17 ("clk: qcom: gcc: Add support for Global Clock Controller")Signed-off-by Jagadeesh Kona <[email protected]>--- drivers/clk/qcom/gcc-glymur.c | 4 ++-- 1 file changed, 2 insertions(+), 2 deletions(-)drivers/clk/qcom/gcc-glymur.c +1
-1@@ -2317,7 +2317,7 @@ static struct clk_rcg2 gcc_sdcc2_apps_clk_src = { .parent_data = gcc_parent_data_17, .num_parents = ARRAY_SIZE(gcc_parent_data_17), .flags = CLK_SET_RATE_PARENT, - .ops = &clk_rcg2_floor_ops, + .ops = &clk_rcg2_shared_floor_ops, }, };
drivers/clk/qcom/gcc-glymur.c static struct clk_rcg2 gcc_sdcc4_apps_clk_src = { · line 2345
Quoted 8 lines
drivers/clk/qcom/gcc-glymur.c +1
-1@@ -2339,7 +2339,7 @@ static struct clk_rcg2 gcc_sdcc4_apps_clk_src = { .parent_data = gcc_parent_data_3, .num_parents = ARRAY_SIZE(gcc_parent_data_3), .flags = CLK_SET_RATE_PARENT, - .ops = &clk_rcg2_floor_ops, + .ops = &clk_rcg2_shared_floor_ops, }, };
Signature · 2 lines
Thanks, Taniya Das
Re: [PATCH v2 8/8] clk: qcom: gcc-glymur: Update the SDCC RCGs to use shared_floor_ops
In reply to Jagadeesh KonaQuoted 11 lines · Jagadeesh Kona
Use
shared_floor_opsfor the SDCC RCGs so the RCG is safely parked during disable and the new parent configuration is programmed in hardware only when the new parent is enabled, avoiding cases where the RCG configuration fails to update.Fixes efe504300a17 ("clk: qcom: gcc: Add support for Global Clock Controller")Signed-off-by Jagadeesh Kona <[email protected]>--- drivers/clk/qcom/gcc-glymur.c | 4 ++-- 1 file changed, 2 insertions(+), 2 deletions(-)
Thanks,
Imran
Quoted 10 lines · Jagadeesh Kona
This series updates the clock ops to
clk_rcg2_shared_floor_opsfor the SDCC RCGs on SM8450, SM8750, SM4450, SDX75, Milos, X1E80100, QDU1000 and GLYMUR chipsets.This change is required to ensure RCG is safely parked during disable and new parent configuration is programmed in hardware only when new parent is enabled, to avoid cases where RCG configuration fails to update and overclocking issues.
[...]
Applied, thanks!
[1/8] clk: qcom: gcc-sm8450: Update the SDCC RCGs to use shared_floor_ops
commit: 4c052c5df93d07e8aa2ce55680f95742f0a08e7a
[2/8] clk: qcom: gcc-sm8750: Update the SDCC RCGs to use shared_floor_ops
commit: 67d7fb1bbdd63eccb9ac6e483e502f88ca9a1e73
[3/8] clk: qcom: gcc-sm4450: Update the SDCC RCGs to use shared_floor_ops
commit: d1fd65ee5555dcfe4b33999b8950d6626cc28d12
[4/8] clk: qcom: gcc-sdx75: Update the SDCC RCGs to use shared_floor_ops
commit: 757ec77514e3e4b345517deef0f5a5152697238e
[5/8] clk: qcom: gcc-milos: Update the SDCC RCGs to use shared_floor_ops
commit: 113fb9649f0d89bfe71dc4e3d98cfc92fda0d73a
[6/8] clk: qcom: gcc-x1e80100: Update the SDCC RCGs to use shared_floor_ops
commit: 988e585fa4d48faccc50a571b569c38ec3bf69c9
[7/8] clk: qcom: gcc-qdu1000: Update the SDCC RCGs to use shared_floor_ops
commit: 0504b96f110f559e130523efeefc8d1d11530c8a
[8/8] clk: qcom: gcc-glymur: Update the SDCC RCGs to use shared_floor_ops
commit: e4dca3e567813cb49e8ffd3b33ec4c6f43c25d10Best regards,
Signature · 1 line
Bjorn Andersson <[email protected]>