Skip to contentSkip to conversation

ath9k: spectral scan -vs- channel state information

ath9k-devel Dan 4 participants 7 messages Apr 12, 2016 – May 18, 2016

lore
Share & tools
lore

Dan

author
#0 lore raw

Hi

I am having some trouble understanding the difference between channel state information (often requested on the mailing list)
and what is currently available via spectral scan.

My understanding is as follows;
- spectral scan (once triggered via the debugfs) logs channel state estimation for each of the 56 ofdm subcarriers (HT20 case). In the spectral code (for ath9k), the channel state
info is the I and Q values for the subcarriers.
For ath9k, the bulk of the code is in ath_process_fft

Bits I dont understand :
Can channel state information be collected on a more general basis ? --- for example for each phy packet received.

Also, the calibration (ar9003_calib) seems to gather I and Q data also... but its not clear when this is run/collected and used.

Any help appreciated....

#1 lore raw
Quoted 7 lines · Dan

Hi

I am having some trouble understanding the difference between channel state information (often requested on the mailing list)
and what is currently available via spectral scan.

Quoted 6 lines

My understanding is as follows;
- spectral scan (once triggered via the debugfs) logs channel state estimation for each of the 56 ofdm subcarriers (HT20 case). In the spectral code (for ath9k), the channel state
info is the I and Q values for the subcarriers.
For ath9k, the bulk of the code is in ath_process_fft

Right. And it's sent over as a PHY error frame.

Quoted 3 lines

Bits I dont understand :
Can channel state information be collected on a more general basis ? --- for example for each phy packet received.

No. There's not enough bandwidth available in the PHY->MAC connection to also throw over that much data per packet. So, you get to trigger it once, and then the next packet gets the CSI data dumped into a memory region in the chip somewhere. Then you read it out.

Quoted 4 lines

Also, the calibration (ar9003_calib) seems to gather I and Q data also... but its not clear when this is run/collected and used.

Any help appreciated....

That's part of ADC calibration. The idea is to calibrate differences in ADCs on the I and Q side of things.

-adrian

author
#2 lore raw
Quoted 30 lines · Adrian Chadd <adrian <at> freebsd.org> writes:
Quoted 7 lines · On 12 April 2016 at 15:05, Dan <aidan <at> plezica.com> wrote:

Hi

I am having some trouble understanding the difference between channel state information (often requested on the mailing list)
and what is currently available via spectral scan.

Quoted 6 lines

My understanding is as follows;
- spectral scan (once triggered via the debugfs) logs channel state estimation for each of the 56 ofdm subcarriers (HT20 case). In the spectral code (for ath9k), the channel state
info is the I and Q values for the subcarriers.
For ath9k, the bulk of the code is in ath_process_fft

Right. And it's sent over as a PHY error frame.

Quoted 3 lines

Bits I dont understand :
Can channel state information be collected on a more general basis ? --- for example for each phy packet received.

No. There's not enough bandwidth available in the PHY->MAC connection to also throw over that much data per packet. So, you get to trigger it once, and then the next packet gets the CSI data dumped into a memory region in the chip somewhere. Then you read it out.

Quoted 2 lines

Also, the calibration (ar9003_calib) seems to gather I and Q data also... but its not clear when this is run/collected and used.

Quoted 7 lines
Quoted 1 line

Any help appreciated....

That's part of ADC calibration. The idea is to calibrate differences in ADCs on the I and Q side of things.

-adrian

Thanks. A few further questions...
For spectral scan, the I/Q values are 'estimations' based on the
IFFT/FFT maths magic in the hardware - and not data that comes
from transmitters (as might be the case in beam forming)
- right ?

In the data structure for the FFT, I can't see (I may well be blind) where the 'phase' values are
stored (Q).... it seems to mention only 'magnitude'
which I am assuming is the magnitude of
the signal (I)
thanks

#3 lore raw
Quoted 37 lines · Dan
Quoted 35 lines · Adrian Chadd <adrian <at> freebsd.org> writes:
Quoted 7 lines · On 12 April 2016 at 15:05, Dan <aidan <at> plezica.com> wrote:

Hi

I am having some trouble understanding the difference between channel state information (often requested on the mailing list)
and what is currently available via spectral scan.

Quoted 6 lines

My understanding is as follows;
- spectral scan (once triggered via the debugfs) logs channel state estimation for each of the 56 ofdm subcarriers (HT20 case). In the spectral code (for ath9k), the channel state
info is the I and Q values for the subcarriers.
For ath9k, the bulk of the code is in ath_process_fft

Right. And it's sent over as a PHY error frame.

Quoted 3 lines

Bits I dont understand :
Can channel state information be collected on a more general basis ? --- for example for each phy packet received.

No. There's not enough bandwidth available in the PHY->MAC connection to also throw over that much data per packet. So, you get to trigger it once, and then the next packet gets the CSI data dumped into a memory region in the chip somewhere. Then you read it out.

Quoted 4 lines

Also, the calibration (ar9003_calib) seems to gather I and Q data also... but its not clear when this is run/collected and used.

Any help appreciated....

That's part of ADC calibration. The idea is to calibrate differences in ADCs on the I and Q side of things.

Quoted 7 lines
Quoted 2 lines

-adrian

Thanks. A few further questions...
For spectral scan, the I/Q values are 'estimations' based on the
IFFT/FFT maths magic in the hardware - and not data that comes
from transmitters (as might be the case in beam forming)

Hm. Well, everything's based on whatever the signal source is, sure. In this instance, it's based on estimations from the two ADC signals (one I, one Q) for each of the OFDM buckets. What you get is the magnitude of both combined, not separate I and Q values.

Quoted 7 lines

- right ?

In the data structure for the FFT, I can't see (I may well be blind) where the 'phase' values are
stored (Q).... it seems to mention only 'magnitude'
which I am assuming is the magnitude of
the signal (I)

Well, there's magnitude and phase, and it gives you the values for each. You have to run it through math to get a power level for each bucket.

https://wiki.freebsd.org/dev/ath_hal%284%29/SpectralScan

You don't get separate readings for I and Q in spectral scan data.

-adrian

#4 lore raw
Quoted 11 lines · Adrian Chadd <adrian <at> freebsd.org> writes:

Well, there's magnitude and phase, and it gives you the values for each. You have to run it through math to get a power level for each bucket.

https://wiki.freebsd.org/dev/ath_hal%284%29/SpectralScan

You don't get separate readings for I and Q in spectral scan data.

-adrian

I'm confused. You say that the spectral scan only gives the magnitude of the I and Q values combined, not separate. But then you say that "there's magnitude and phase, and it gives you the values for each." Doesn't that mean that you do get both the I and Q values (after converting from magnitude/phase values)?

Also, is this the same info that's logged in the "Atheros CSI Tool"
(https://github.com/xieyaxiongfly/Atheros-CSI-Tool)? Or is the spectral scan data completely different?

#5 lore raw

Hi Allen,

Spectral scan sum up I and Q for you and give you the magnitude it. Since I and Q are "merged", no phase information is available.
As Adrian said, you have to run some math to get power in dBm from the special spectral sample format.
If you are able to read Python code, here is an example for the transformation:
https://github.com/bcopeland/speccy/blob/master/spectrum_file.py#L57

If you prefer "real code", there is an implementation how to threat the sample data in Adrians Radarlib:
https://github.com/erikarn/ath_radar_stuff/tree/master/lib/libradarpkt

The paper found on "Atheros CSI Tool" link states:
"The CSI measurements are complex values and hence contain two parts, the amplitude and the phase."
So I guess that with CSI the I and Q values aren't merged. If you do so, you should be able to calculate the power levels - then you should end up with the same information like from spectral scan. But I do not have any first hand experience with CSI, if you have any, please share :)

If you want to play around with the spectral scan feature, I recommend to to give Bob Copelands "Speccy" a try:
https://github.com/bcopeland/speccy

Hope this helps.

Robert

2016-05-09 3:42 GMT+02:00 Allen Welkie <[email protected]>:

Quoted 29 lines
Quoted 11 lines · Adrian Chadd <adrian <at> freebsd.org> writes:

Well, there's magnitude and phase, and it gives you the values for each. You have to run it through math to get a power level for each bucket.

https://wiki.freebsd.org/dev/ath_hal%284%29/SpectralScan

You don't get separate readings for I and Q in spectral scan data.

-adrian

I'm confused. You say that the spectral scan only gives the magnitude of the I and Q values combined, not separate. But then you say that "there's magnitude and phase, and it gives you the values for each." Doesn't that mean that you do get both the I and Q values (after converting from magnitude/phase values)?

Also, is this the same info that's logged in the "Atheros CSI Tool"
(https://github.com/xieyaxiongfly/Atheros-CSI-Tool)? Or is the spectral scan data completely different?

_______________________________________________
ath9k-devel mailing list
ath9k-devel at lists.ath9k.org
https://lists.ath9k.org/mailman/listinfo/ath9k-devel

author
#6 lore raw
Quoted 27 lines · Robert Felten <robert.felten <at> googlemail.com> writes:

Hi Allen,

Spectral scan sum up I and Q for you and give you the magnitude it. Since I and Q are "merged", no phase information is available.
As Adrian said, you have to run some math to get power in dBm from the special spectral sample format.
If you are able to read Python code, here is an example for the transformation:
https://github.com/bcopeland/speccy/blob/master/spectrum_file.py#L57

If you prefer "real code", there is an implementation how to threat the sample data in Adrians Radarlib:
https://github.com/erikarn/ath_radar_stuff/tree/master/lib/libradarpkt

The paper found on "Atheros CSI Tool" link states:
"The CSI measurements are complex values and hence contain two parts, the amplitude and the phase."
So I guess that with CSI the I and Q values aren't merged. If you do so, you should be able to calculate the power levels - then you should end up with the same information like from spectral scan. But I do not have any first hand experience with CSI, if you have any, please share :)

If you want to play around with the spectral scan feature, I recommend to to give Bob Copelands "Speccy" a try:
https://github.com/bcopeland/speccy

Quoted 35 lines

Hope this helps.

Robert

2016-05-09 3:42 GMT+02:00 Allen Welkie <allen.welkie <at> gmail.com>:

Quoted 29 lines
Quoted 11 lines · Adrian Chadd <adrian <at> freebsd.org> writes:

Well, there's magnitude and phase, and it gives you the values for each. You have to run it through math to get a power level for each bucket.

https://wiki.freebsd.org/dev/ath_hal%284%29/SpectralScan

You don't get separate readings for I and Q in spectral scan data.

-adrian

I'm confused. You say that the spectral scan only gives the magnitude of the I and Q values combined, not separate. But then you say that "there's magnitude and phase, and it gives you the values for each." Doesn't that mean that you do get both the I and Q values (after converting from magnitude/phase values)?

Also, is this the same info that's logged in the "Atheros CSI Tool"
(https://github.com/xieyaxiongfly/Atheros-CSI-Tool)? Or is the spectral scan data completely different?

_______________________________________________
ath9k-devel mailing list
ath9k-devel <at> lists.ath9k.org
https://lists.ath9k.org/mailman/listinfo/ath9k-devel

Hi Folks

I have been using both Spectral and CSI.