Skip to contentSkip to conversation

Fail to Capture QOS data packets in Monitoring mode - QCA988x‏‏

DISCUSSION sdhrtht 2 participants 3 messages Jul 26, 2016 Qualcomm Atheros ATH10K wireless driver

lore
Share & tools
lore

sdhrtht

author
#0 lore raw

ath10k monitor failing to capture data packets with WMM enabled on AP.

AP Status: (when no QOS data Packets. MGMT and CTRL Packets are able to captured)
1) 0x03 (3) - Secondary channel is below Primary
2) 1 - any Channel width in secondary channel width
3) 1 - Use of RIFS permitted
4) 0x02 - Only HT STAs in the BSS, however there exists at least on 20Mhz STA
5) 0 - all Associated HT STAs are greenfield capable

Tested with latest CT and non-CT firmware's.

_______________________________________________
ath10k mailing list
[email protected]
http://lists.infradead.org/mailman/listinfo/ath10k

#1 lore raw

Hi,

The following may not necessarily be your case. But since you mentioned MGMT and CTRL packets are captured and not QoS data packets, I observed a similar behavior when my configuration was as below:
* Sender: Operating 80Mhz dynamic channel width (secondary channel either above or below primary channel, doesn't matter)
* Sniffer: Operating on 80MHz width. However, the sniffer's primary channel doesn't overlap with the sender's primary channel; basically they have different primary channels.

It is necessary that the primary channels of the sender and the sniffer match. Otherwise, the sniffer is able to only see the non-HT duplicate frames sent by the sender. This is because those frames are sent on all the four 20MHz channels, one of which is your sniffer's primary channel.

I am not sure if the greenfield configuration could be a culprit here. But you might want to check the above first :)

Cheers,
Raj Joshi

Quoted 11 lines · sdhrtht

ath10k monitor failing to capture data packets with WMM enabled on AP.

AP Status: (when no QOS data Packets. MGMT and CTRL Packets are able to captured)
1) 0x03 (3) - Secondary channel is below Primary
2) 1 - any Channel width in secondary channel width
3) 1 - Use of RIFS permitted
4) 0x02 - Only HT STAs in the BSS, however there exists at least on 20Mhz STA
5) 0 - all Associated HT STAs are greenfield capable

Quoted 7 lines

Tested with latest CT and non-CT firmware's.

_______________________________________________
ath10k mailing list
[email protected]
http://lists.infradead.org/mailman/listinfo/ath10k

_______________________________________________
ath10k mailing list
[email protected]
http://lists.infradead.org/mailman/listinfo/ath10k

#2 lore raw

Went through same path and verified with COMMVIEW on primary and secondary channels.

on the other hand, surprisingly Qos packets appears when there another devices associates with  AP and disappears when it disconnects. only greenfield mode is disabled during the transition when second STA association happens.

----------------------------------------

Quoted 23 lines

From: [email protected]
Date: Tue, 26 Jul 2016 10:07:45 +0800
Subject: Re: Fail to Capture QOS data packets in Monitoring mode - QCA988x‏‏
To: [email protected]
CC: [email protected]

Hi,

The following may not necessarily be your case. But since you mentioned MGMT and CTRL packets are captured and not QoS data packets, I observed a similar behavior when my configuration was as below:
* Sender: Operating 80Mhz dynamic channel width (secondary channel either above or below primary channel, doesn't matter)
* Sniffer: Operating on 80MHz width. However, the sniffer's primary channel doesn't overlap with the sender's primary channel; basically they have different primary channels.

It is necessary that the primary channels of the sender and the sniffer match. Otherwise, the sniffer is able to only see the non-HT duplicate frames sent by the sender. This is because those frames are sent on all the four 20MHz channels, one of which is your sniffer's primary channel.

Quoted 26 lines

I am not sure if the greenfield configuration could be a culprit here. But you might want to check the above first :)

Cheers,
Raj Joshi

Quoted 18 lines · sdhrtht

ath10k monitor failing to capture data packets with WMM enabled on AP.

AP Status: (when no QOS data Packets. MGMT and CTRL Packets are able to captured)
1) 0x03 (3) - Secondary channel is below Primary
2) 1 - any Channel width in secondary channel width
3) 1 - Use of RIFS permitted
4) 0x02 - Only HT STAs in the BSS, however there exists at least on 20Mhz STA
5) 0 - all Associated HT STAs are greenfield capable

Tested with latest CT and non-CT firmware's.

_______________________________________________
ath10k mailing list
[email protected]
http://lists.infradead.org/mailman/listinfo/ath10k

_______________________________________________
ath10k mailing list
[email protected]
http://lists.infradead.org/mailman/listinfo/ath10k