Hi ,

I have copied ".bin" file of an application program onto "0xb0300000" flash location in the INCA-IP board from Infineon .
When trying to execute this application from flash , using "go 0xb0300000" , the following message is displayed.

INCA-IP-ROM # go 0xb0300000
## Starting application at 0xB0300000 ...

After this message , no more execution was happening ( the board is hanging).

Kindly, provide me with tips on how I can solve this issue..

Thank You,
Verma.

Signature · 2 lines
View this message in context: http://www.nabble.com/u-boot-%22go%22-command-query-tf4729580.html#a13523892
Sent from the Uboot - Users mailing list archive at Nabble.com.
#1 lore raw
Quoted 6 lines · In message <[email protected]> you wrote:

I have copied ".bin" file of an application program onto "0xb0300000" flash location in the INCA-IP board from Infineon .
When trying to execute this application from flash , using "go 0xb0300000" , the following message is displayed.

Quoted 7 lines

INCA-IP-ROM # go 0xb0300000
## Starting application at 0xB0300000 ...

After this message , no more execution was happening ( the board is hanging).

Kindly, provide me with tips on how I can solve this issue..

Did you read the FAQ? Especially
http://www.denx.de/wiki/view/DULG/MyStandaloneProgramDoesNotWork ???

Best regards,

Wolfgang Denk

Signature · 4 lines
DENX Software Engineering GmbH,     MD: Wolfgang Denk & Detlev Zundel
HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany
Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80 Email: wd at denx.de
I am more bored than you could ever possibly be.  Go back to work.
author
#2 lore raw
In reply to Verma

When we have obtained the symbol table for the stand alone application , we have noticed that the addresses of all the global variables and function definitions are starting with 0x802xxxxx. Hence, any standalone application developed for INCA-IP has to be copied into the 0x80200000 location of the RAM.

Verma.

Quoted 19 lines · Verma

Hi ,

I have copied ".bin" file of an application program onto "0xb0300000" flash location in the INCA-IP board from Infineon .
When trying to execute this application from flash , using "go 0xb0300000" , the following message is displayed.

INCA-IP-ROM # go 0xb0300000
## Starting application at 0xB0300000 ...

After this message , no more execution was happening ( the board is hanging).

Kindly, provide me with tips on how I can solve this issue..

Thank You,
Verma.

Signature · 2 lines
View this message in context: http://www.nabble.com/u-boot-%22go%22-command-query-tf4729580.html#a13739789
Sent from the Uboot - Users mailing list archive at Nabble.com.
#3 lore raw

Hi Verma,

Quoted 5 lines

When we have obtained the symbol table for the stand alone application , we have noticed that the addresses of all the global variables and function definitions are starting with 0x802xxxxx. Hence, any standalone application developed for INCA-IP has to be copied into the 0x80200000 location of the RAM.

If you check examples/Makefile, you will notice these two lines:

ifeq ($(ARCH),mips)
LOAD_ADDR = 0x80200000 -T mips.lds
endif

So your hypothesis is correct, as the binary is intentionally linked to that address on MIPS platforms.

Cheers
Detlev

Signature · 7 lines
(let ((s "bottles of beer on the wall")) ((lambda (f) (f f 99))
(lambda (f i) (or (= i 0) (format #t "~a ~a - take one down pass it around
~a ~a\n" i s (- i 1) s) (f f (- i 1))))))
--
DENX Software Engineering GmbH,      MD: Wolfgang Denk & Detlev Zundel
HRB 165235 Munich,  Office: Kirchenstr.5, D-82194 Groebenzell, Germany
Phone: (+49)-8142-66989-40 Fax: (+49)-8142-66989-80 Email: dzu at denx.de