pfifo_fast doesn't seem to use bands
Quoted 12 lines · Balazs Miklos
Hi,
I have a Redhat Linux 7.2 box with stock 2.4.7 kernel and I'm trying to do some bandwidth management with tc..
I have created a CBQ class-hierarchy, and I have a class which is limited to 16Kbit and it can grow up to 32Kbits if there is available free bandwidth in the other classes. This class hasn't got any qdiscs attached to it, so (as I understood) it should have thepfifo_fastqdisc by default. But I have made a little test: I've mangled the TOS field of the router's outgoing ICMP packets to be0x10(minimize delay), and I checked with tcpdump that they are actually getting mangled.
Quoted 6 lines
The problem is, that it doesn't seem to make any difference... the ping is fine if the class is empty, but if I'm doing a download and pinging the router at the same time, I experience delays in ping replies in both cases (either if the ICMP headers are mangled or not). Shouldn't the TOS mangled ping replies arrive with no delays at all, while the class is full with bulk traffic?
Why not doing the test after you add a pfifo_qdisc to that class? Just to see if it makes any difference.
Stef
Signature · 8 lines
[email protected] "Using Linux as bandwidth manager" http://www.docum.org/ #lartc @ irc.oftc.net _______________________________________________ LARTC mailing list / [email protected] http://mailman.ds9a.nl/mailman/listinfo/lartc HOWTO: http://lartc.org/
Hi,
I have a Redhat Linux 7.2 box with stock 2.4.7 kernel and I'm trying to do some bandwidth management with tc..
I have created a CBQ class-hierarchy, and I have a class which is limited to 16Kbit and it can grow up to 32Kbits if there is available free bandwidth in the other classes. This class hasn't got any qdiscs attached to it, so (as I understood) it should have the pfifo_fast qdisc by default. But I have made a little test: I've mangled the TOS field of the router's outgoing ICMP packets to be 0x10 (minimize delay), and I checked with tcpdump that they are actually getting mangled.
The problem is, that it doesn't seem to make any difference... the ping is fine if the class is empty, but if I'm doing a download and pinging the router at the same time, I experience delays in ping replies in both cases (either if the ICMP headers are mangled or not). Shouldn't the TOS mangled ping replies arrive with no delays at all, while the class is full with bulk traffic?
Or did I misunderstood something?
Thanks in advance,
Signature · 5 lines
Balazs Miklos <[email protected]> _______________________________________________ LARTC mailing list / [email protected] http://mailman.ds9a.nl/mailman/listinfo/lartc HOWTO: http://lartc.org/