Skip to contentSkip to conversation

MIDI port names

DISCUSSION Pedro Lopez-Cabanillas 3 participants 8 messages Feb 19, 2003 – Feb 25, 2003 1 message not in the archive

lore
Share & tools
lore

A message that is not in the archive (sent off-list or not yet received): [email protected]

#1 lore raw
Quoted 9 lines · Takashi Iwai

there is the name field for each rawmidi substream, and the sequencer looks up this string.

this reminds me the former patch by Clemens, and i've forgotten to check this issue until now. sorry.

i modified the sequencer part (and mpu401_uart) on the cvs so that the sequencer retrieves the rawmidi name string if the substream name is not defined.

But Clemens' patch (attached is a slightly modified version) was not for port names but for client names, from "External MIDI x" to the more meaningful rawmidi name. I think that this is what some people is requesting, and makes things easier for large studio setups when some applications, like kaconnect, show client names but not port names. Please, apply.

Regards,
Pedro

Signature · 2 lines
ALSA Library Bindings for Pascal
http://alsapas.alturl.com
core/seq/seq_midi.c renamed from core/seq/seq_midi.c.old +4 -1
@@ -329,7 +329,10 @@
 		memset(&inf,0,sizeof(snd_seq_client_info_t));
 		inf.client = client->seq_client;
 		inf.type = KERNEL_CLIENT;
-		sprintf(inf.name, "External MIDI %i", card->number);
+		if (info.name[0])
+			strncpy(inf.name, info.name, sizeof(inf.name) - 1);
+		else
+			sprintf(inf.name, "External MIDI %i", card->number);
 		snd_seq_kernel_client_ctl(client->seq_client, SNDRV_SEQ_IOCTL_SET_CLIENT_INFO, &inf);
 	}
 
#2 lore raw
Quoted 11 lines · Pedro Lopez-Cabanillas
Quoted 9 lines · Takashi Iwai

there is the name field for each rawmidi substream, and the sequencer looks up this string.

this reminds me the former patch by Clemens, and i've forgotten to check this issue until now. sorry.

i modified the sequencer part (and mpu401_uart) on the cvs so that the sequencer retrieves the rawmidi name string if the substream name is not defined.

Quoted 5 lines

But Clemens' patch (attached is a slightly modified version) was not for port names but for client names, from "External MIDI x" to the more meaningful rawmidi name. I think that this is what some people is requesting, and makes things easier for large studio setups when some applications, like kaconnect, show client names but not port names. Please, apply.

I don't agree with this patch. kaconnect or other applications might simply parse the string and if matches - get the real name over the control interface. Otherwise, it is not clear, that the port is equal to a rawmidi device.

Jaroslav

-----
Jaroslav Kysela <[email protected]>
Linux Kernel Sound Maintainer
ALSA Project, SuSE Labs

-------------------------------------------------------
This SF.net email is sponsored by: SlickEdit Inc. Develop an edge. The most comprehensive and flexible code editor you can use. Code faster. C/C++, C#, Java, HTML, XML, many more. FREE 30-Day Trial. www.slickedit.com/sourceforge

#3 lore raw

At Thu, 20 Feb 2003 09:55:18 +0100 (CET),

Quoted 20 lines · Jaroslav
Quoted 11 lines · Pedro Lopez-Cabanillas
Quoted 9 lines · Takashi Iwai

there is the name field for each rawmidi substream, and the sequencer looks up this string.

this reminds me the former patch by Clemens, and i've forgotten to check this issue until now. sorry.

i modified the sequencer part (and mpu401_uart) on the cvs so that the sequencer retrieves the rawmidi name string if the substream name is not defined.

Quoted 5 lines

But Clemens' patch (attached is a slightly modified version) was not for port names but for client names, from "External MIDI x" to the more meaningful rawmidi name. I think that this is what some people is requesting, and makes things easier for large studio setups when some applications, like kaconnect, show client names but not port names. Please, apply.

Quoted 4 lines

I don't agree with this patch. kaconnect or other applications might simply parse the string and if matches - get the real name over the control interface. Otherwise, it is not clear, that the port is equal to a rawmidi device.

it's of course a bit dangerous to change such behavior.

but basically, the application shouldn't rely on the client name string to get its information. and, AFAIK, there are no applications to do that, so far. hence, i don't think it would cause much problems.

if it looks ok for you, i'll commit more changes in this regard, including:

- set the sequencer client name from rawmidi name (like above)
- reset the sequencer client name for the rawmidi device 0 in the case that other device was registered formerly.
- set the name of mpu401_uart from card's shortname if already defined.

the last one requires the definition of the shortname field before calling snd_mpu401_uart_new(). if not defined, "MPU401 (UART)" is used like the older version.

Takashi

-------------------------------------------------------
This SF.net email is sponsored by: SlickEdit Inc. Develop an edge. The most comprehensive and flexible code editor you can use. Code faster. C/C++, C#, Java, HTML, XML, many more. FREE 30-Day Trial. www.slickedit.com/sourceforge

#4 lore raw
Quoted 43 lines · Takashi Iwai

At Thu, 20 Feb 2003 09:55:18 +0100 (CET),

Quoted 20 lines · Jaroslav
Quoted 11 lines · Pedro Lopez-Cabanillas
Quoted 9 lines · Takashi Iwai

there is the name field for each rawmidi substream, and the sequencer looks up this string.

this reminds me the former patch by Clemens, and i've forgotten to check this issue until now. sorry.

i modified the sequencer part (and mpu401_uart) on the cvs so that the sequencer retrieves the rawmidi name string if the substream name is not defined.

Quoted 5 lines

But Clemens' patch (attached is a slightly modified version) was not for port names but for client names, from "External MIDI x" to the more meaningful rawmidi name. I think that this is what some people is requesting, and makes things easier for large studio setups when some applications, like kaconnect, show client names but not port names. Please, apply.

Quoted 4 lines

I don't agree with this patch. kaconnect or other applications might simply parse the string and if matches - get the real name over the control interface. Otherwise, it is not clear, that the port is equal to a rawmidi device.

it's of course a bit dangerous to change such behavior.

but basically, the application shouldn't rely on the client name string to get its information. and, AFAIK, there are no applications to do that, so far. hence, i don't think it would cause much problems.

if it looks ok for you, i'll commit more changes in this regard, including:

- set the sequencer client name from rawmidi name (like above)
- reset the sequencer client name for the rawmidi device 0 in the case that other device was registered formerly.
- set the name of mpu401_uart from card's shortname if already defined.

Quoted 3 lines

the last one requires the definition of the shortname field before calling snd_mpu401_uart_new(). if not defined, "MPU401 (UART)" is used like the older version.

If there is a way to determine the connection between sequencer port and rawmidi device, I'm ok with any solution. Otherwise, please, solve this problem.

Jaroslav

-----
Jaroslav Kysela <[email protected]>
Linux Kernel Sound Maintainer
ALSA Project, SuSE Labs

-------------------------------------------------------
This SF.net email is sponsored by: SlickEdit Inc. Develop an edge. The most comprehensive and flexible code editor you can use. Code faster. C/C++, C#, Java, HTML, XML, many more. FREE 30-Day Trial. www.slickedit.com/sourceforge

#5 lore raw

At Thu, 20 Feb 2003 15:14:45 +0100 (CET),

Quoted 4 lines · Jaroslav

If there is a way to determine the connection between sequencer port and rawmidi device, I'm ok with any solution. Otherwise, please, solve this problem.

one of the advantages of the sequencer is that it hides the lowlevel implementations, regardless of mpu401 or wavetable. hence, there is no explicit link between the lowlevel device and the sequencer client/port, so far. there are only bit flags indicating what kind of functions are supported by the port.

it's not bad to have such an attribute, though. but if we have that, it will be an addition.

Takashi

-------------------------------------------------------
This SF.net email is sponsored by: SlickEdit Inc. Develop an edge. The most comprehensive and flexible code editor you can use. Code faster. C/C++, C#, Java, HTML, XML, many more. FREE 30-Day Trial. www.slickedit.com/sourceforge

#6 lore raw
Quoted 7 lines · Takashi Iwai

At Thu, 20 Feb 2003 15:14:45 +0100 (CET),

Quoted 4 lines · Jaroslav

If there is a way to determine the connection between sequencer port and rawmidi device, I'm ok with any solution. Otherwise, please, solve this problem.

Quoted 8 lines

one of the advantages of the sequencer is that it hides the lowlevel implementations, regardless of mpu401 or wavetable. hence, there is no explicit link between the lowlevel device and the sequencer client/port, so far. there are only bit flags indicating what kind of functions are supported by the port.

it's not bad to have such an attribute, though. but if we have that, it will be an addition.

We can use different name for client like:

RawMIDI - %s

Where %s is whatever you want ;-)) card->shortname, card->id or anything else. The card number can be calculated from the client address and device / subdevice from the port address.

Jaroslav

-----
Jaroslav Kysela <[email protected]>
Linux Kernel Sound Maintainer
ALSA Project, SuSE Labs

-------------------------------------------------------
This SF.net email is sponsored by: SlickEdit Inc. Develop an edge. The most comprehensive and flexible code editor you can use. Code faster. C/C++, C#, Java, HTML, XML, many more. FREE 30-Day Trial. www.slickedit.com/sourceforge

#7 lore raw

At Thu, 20 Feb 2003 21:19:19 +0100 (CET),

Quoted 19 lines · Jaroslav
Quoted 7 lines · Takashi Iwai

At Thu, 20 Feb 2003 15:14:45 +0100 (CET),

Quoted 4 lines · Jaroslav

If there is a way to determine the connection between sequencer port and rawmidi device, I'm ok with any solution. Otherwise, please, solve this problem.

Quoted 8 lines

one of the advantages of the sequencer is that it hides the lowlevel implementations, regardless of mpu401 or wavetable. hence, there is no explicit link between the lowlevel device and the sequencer client/port, so far. there are only bit flags indicating what kind of functions are supported by the port.

it's not bad to have such an attribute, though. but if we have that, it will be an addition.

Quoted 7 lines

We can use different name for client like:

RawMIDI - %s

Where %s is whatever you want ;-)) card->shortname, card->id or anything else. The card number can be calculated from the client address and device / subdevice from the port address.

done.
now everthing became more verbose :)

Takashi

-------------------------------------------------------
This sf.net email is sponsored by:ThinkGeek
Welcome to geek heaven.
http://thinkgeek.com/sf

#8 lore raw
In reply to Jaroslav Kysela
Quoted 52 lines · Jaroslav Kysela
Quoted 43 lines · Takashi Iwai

At Thu, 20 Feb 2003 09:55:18 +0100 (CET),

Quoted 19 lines · Jaroslav
Quoted 11 lines · Pedro Lopez-Cabanillas
Quoted 9 lines · Takashi Iwai

there is the name field for each rawmidi substream, and the sequencer looks up this string.

this reminds me the former patch by Clemens, and i've forgotten to check this issue until now. sorry.

i modified the sequencer part (and mpu401_uart) on the cvs so that the sequencer retrieves the rawmidi name string if the substream name is not defined.

Quoted 6 lines

But Clemens' patch (attached is a slightly modified version) was not for port names but for client names, from "External MIDI x" to the more meaningful rawmidi name. I think that this is what some people is requesting, and makes things easier for large studio setups when some applications, like kaconnect, show client names but not port names. Please, apply.

Quoted 4 lines

I don't agree with this patch. kaconnect or other applications might simply parse the string and if matches - get the real name over the control interface. Otherwise, it is not clear, that the port is equal to a rawmidi device.

it's of course a bit dangerous to change such behavior.

but basically, the application shouldn't rely on the client name string to get its information. and, AFAIK, there are no applications to do that, so far. hence, i don't think it would cause much problems.

if it looks ok for you, i'll commit more changes in this regard, including:

- set the sequencer client name from rawmidi name (like above)
- reset the sequencer client name for the rawmidi device 0 in the case that other device was registered formerly.
- set the name of mpu401_uart from card's shortname if already defined.

Quoted 3 lines

the last one requires the definition of the shortname field before calling snd_mpu401_uart_new(). if not defined, "MPU401 (UART)" is used like the older version.

If there is a way to determine the connection between sequencer port and rawmidi device, I'm ok with any solution. Otherwise, please, solve this problem.

Quoted 6 lines

Jaroslav

-----
Jaroslav Kysela <[email protected]>
Linux Kernel Sound Maintainer
ALSA Project, SuSE Labs

Hi Jaroslav,

I understand your complaints, so let me to propose another solution. Or almost contribute to the brainstorming session :-)

What about card->id instead of card->number ? I mean, something like "External MIDI ENS1371" for client names. Or perhaps only the card->id field alone. This allows you to reach the relevant information from ctl interface, with only a little more work compared with having card->number inside the client's name.

The card->id field can be used also to compose a path name with ("/proc/asound/" + card->id) giving the name of a symlink to the /proc/asound/cardX directory, allowing an easy way to get some information, inclusively for scripts.

The card->id field allows also a customization level, via the "id" module params available to every ALSA driver, so the user can change, for example, "ENS1371" to something like "SB 128 PCI", or any other meaningful, user friendly name.

Finally, with this solution we don't need to add another field to snd_seq_client_info_t or any other data structure. Hmmm. Sounds too much good to be true, so I think I missed again some point :-)

Regards,
Pedro

Signature · 10 lines
ALSA Library Bindings for Pascal
http://alsapas.alturl.com



-------------------------------------------------------
This SF.net email is sponsored by: SlickEdit Inc. Develop an edge.
The most comprehensive and flexible code editor you can use.
Code faster. C/C++, C#, Java, HTML, XML, many more. FREE 30-Day Trial.
www.slickedit.com/sourceforge