Skip to content

Add power control for lm90

Wei Ni linux-tegra lm-sensors 1 version In review

Get series with b4
b4 am [email protected]

Versions newest first

  1. v5 Latest3 patches 12 repliesIn review

Changes in v5 from the cover letter

1. set vcc-supply as required property.

Patches in v5 No applies recorded yet

#Subject and filesSizeRepliesApplied
1/3hwmon: (lm90) Add power controldrivers/hwmon/lm90.c+19 -01 reply
2/3of: add vendor prefix for GMTDocumentation/devicetree/bindings/vendor-prefixes.txt+1 -02 replies
3/3Documentation: dt: hwmon: add OF document for LM90Documentation/devicetree/bindings/hwmon/lm90.txt+44 -03 replies

Reviews trailers per patch

None of the 3 patches has a Reviewed-by or Acked-by of their own; the series has one for all of them.

PatchStephen Warren
SeriesA-b
1/3
2/3
3/3

Trailers given in replies are filled; those carried in the patches from earlier versions are outlined with dashes.

Read the v5 thread

Cover letter [PATCH v5 0/3] Add power control for lm90

The device lm90 can be controlled by the vcc rail. Add function to power on/off the vcc.
I will update all .dts files referencing this driver to match the new requirement in my next series.

This series is v5, previous version patches are:
[v4]: http://www.spinics.net/lists/lm-sensors/msg39583.html
[v3]: http://www.spinics.net/lists/lm-sensors/msg39503.html
[v2]: http://www.spinics.net/lists/arm-kernel/msg265373.html
[v1]: http://www.mail-archive.com/[email protected]/msg12034.html

Changes from v4:
1. set vcc-supply as required property.

Changes from v3:
1. change to use devm_regulator_get, as per discussion in previous patches.
2. just return errors when get error from regulator_get(), Mark's new dummy regulator can cope with errors.
3. add vendor prefix for GMT
3. list manufacturer in the binding doc.

Changes from v2:
1. use devm_regulator_get_optional(), as suggested by Mark.
2. remove the lm90_power_control(), enable the regulator in the probe() directly, so the codes are more clear, as suggested by Alexander and Guenter.
3. change the binding documentation, as per Stephen suggestion.
4. couple of changes, as per previous review.

Changes from v1:
1. if get regulator failed, we should continue to run probe function, not return fail.
2. call regulator_put() in error handler and remove function.
3. add LM90 DT binding document.

Wei Ni (3):
hwmon: (lm90) Add power control
of: add vendor prefix for GMT
Documentation: dt: hwmon: add OF document for LM90

 Documentation/devicetree/bindings/hwmon/lm90.txt   |   44 ++++++++++++++++++++
 .../devicetree/bindings/vendor-prefixes.txt        |    1 +
 drivers/hwmon/lm90.c                               |   19 +++++++++
 3 files changed, 64 insertions(+)
 create mode 100644 Documentation/devicetree/bindings/hwmon/lm90.txt
Signature · 1 line
1.7.9.5