Skip to content

RFC vdpa: dedicated descriptor table group

Si-Wei Liu virtualization 2 versions – In review

Get series with b4
b4 am [email protected]

Versions newest first · linked by author and title

  1. v2 RFC Latest3 patches 3 repliesIn review
  2. v1 RFC3 patches 7 repliesSuperseded

Patches in v2 No applies recorded yet

#Subject and filesSizeRepliesApplied
1/3vdpa: introduce dedicated descriptor group for virtqueueinclude/linux/vdpa.h+11 -00 replies
2/3vhost-vdpa: introduce descriptor group backend featuredrivers/vhost/vdpa.c include/uapi/linux/vhost_types.h+22 -00 replies
3/3vhost-vdpa: uAPI to get dedicated descriptor group iddrivers/vhost/vdpa.c include/uapi/linux/vhost.h+18 -00 replies

Reviews trailers per patch

All 3 patches have a Reviewed-by or Acked-by.

PatchEugenio Pérez
1/3A-b
2/3A-b
3/3A-b

Trailers given in replies are filled; those carried in the patches from earlier versions are outlined with dashes.

Read the v2 thread

Cover letter [PATCH RFC v2 0/3] vdpa: dedicated descriptor table group

Following patchset introduces dedicated group for descriptor table to reduce live migration downtime when passthrough VQ is being switched to shadow VQ. This RFC v2 is sent to incorporate the early feedback from reviewers on the uAPI and driver API part of changes, the associated driver patch set consuming ths API will come around soon along with formal submission of this series.

Some initial performance data will be gathered using the real hardware device with mlx5_vdpa. The target goal of this series is to reduce the SVQ switching overhead to less than 300ms on a ~100GB guest with 2 non-mq vhost-vdpa devices. The reduction in the downtime is thanks to avoiding the full remap in the switching.

The plan of the intended driver implementation is to use a dedicated group (specifically, 2 in below table) to host the descriptor tables for data vqs, different from where buffer addresses are contained (in group 0 as below). cvq does not have to allocate dedicated group for descriptor table, so its buffers and descriptor table would always belong to the same group (1 in table below).

| data vq | ctrl vq
==============+==========+===========

vq_group      |    0     |    1
vq_desc_group |    2     |    1

---

Si-Wei Liu (3):
vdpa: introduce dedicated descriptor group for virtqueue
vhost-vdpa: introduce descriptor group backend feature
vhost-vdpa: uAPI to get dedicated descriptor group id

 drivers/vhost/vdpa.c             | 27 +++++++++++++++++++++++++++
 include/linux/vdpa.h             | 11 +++++++++++
 include/uapi/linux/vhost.h       |  8 ++++++++
 include/uapi/linux/vhost_types.h |  5 +++++
 4 files changed, 51 insertions(+)
Signature · 6 lines
1.8.3.1

_______________________________________________
Virtualization mailing list
[email protected]
https://lists.linuxfoundation.org/mailman/listinfo/virtualization