Marvell EBU thermal sensor consolidation
Get series with b4
b4 am 20130321122609.GB22714@localhostVersions newest first
- v1 Latest0 of 16 patches 0 repliesNew
Patches in v1 No applies recorded yet
None of the 16 patches the cover letter announces are in this archive.
Reviews trailers per patch
No Reviewed-by, Acked-by or Tested-by trailers for v1 yet.
Cover letter [PATCH 00/16] Marvell EBU thermal sensor consolidation
Quoted 18 lines · Andrew Lunn
Quoted 6 lines · Ezequiel Garcia
This patchset is my first attempt at adding basic thermal sensor support on Armada 370 and Armada XP.
Given Armada 370/XP and the other Marvell SoC with thermal support, namely Kirkwood and Dove, have fairly similar thermal devices it made sense to integrate all of them into a single driver: mvebu-thermal.
I went this way to start with, merging Dove, Kirkwood and something which nearly worked for 370. But then i looked at the code, at how little is actually shared, and went back to separate drivers.
Kirkwood has no control registers, so needs a special case in the probe. The bit location of the temperate value moves around in the register. Each SoC needs its own initialization sequence.
Each SoC needs its ownis_valid()function.
Each Soc needs its own formula to convert to milli centigrad.
Quoted 4 lines
I've never seen the datasheets for 370/XP, just a list of registers for
370. But i get the impression it has two temperate sensors, so should export two values?
Why do you think it has two sensors?
Signature · 3 lines
Ezequiel Garc?a, Free Electrons Embedded Linux, Kernel and Android Engineering http://free-electrons.com