Switch internal registers address to 0xF1 on Armada 370/XP
Get series with b4
b4 am [email protected]Versions newest first
- v1 Latest0 of 9 patches 0 repliesNew
Patches in v1 No applies recorded yet
None of the 9 patches the cover letter announces are in this archive.
Reviews trailers per patch
No Reviewed-by, Acked-by or Tested-by trailers for v1 yet.
Cover letter [PATCH 0/9] Switch internal registers address to 0xF1 on Armada 370/XP
Quoted 22 lines · Thomas Petazzoni
Dear Willy Tarreau,
Quoted 2 lines · Willy Tarreau
Just out of curiosity, what happens if you touch the register at the wrong address ?
On Armada 370/XP, it hangs the CPU.
Quoted 3 lines
I mean, if you blindly write to the 0xD0xxxxxx address that you want the registers to be mapped at 0xF1xxxxxx. Will the chip hang, will it silently ignore the sequence ?
Answered above: it hangs.
Quoted 7 lines
Because maybe you don't need to detect using CP15 whether the remapping was done, you could simply perform it unconditionally. Another point would be that if the boot loader is the only one to know whether the registeres were remapped, then maybe it could put something into the atags or DT about this. And maybe we'll simply find that DT-enabled boot loaders are remapped and that non-DT ones are not.
Quoted 7 lines
Quoted 2 lines
Just a few ideas since you feel a bit worried about the fragility of the CP15 bit :-)
No, as explained above, we have considered a way of "detecting" whether the remapping occurred, or to unconditionally do the remapping. But none of those solutions work: we need to know, through some external mechanism, whether the remapping has already taken place or not.
OK, thank you for these precisions.
Best regards,
Willy