Refactor thermal pressure update to avoid code duplication
Status from this message: Applied. Thanks.
Get series with b4
b4 am [email protected]Versions newest first · linked by author and title
- v4 Latest5 patches 10 repliesApplied
- v35 patches 21 repliesSuperseded
- v25 patches 11 repliesSuperseded
Earlier versions · 1
| Version | Posted | Patches | Replies | Status |
|---|---|---|---|---|
| v1 | 5 patches | 4 replies | Superseded |
Changes in v4 from the cover letter
- remove the warning when boost frequency is passed and set thermal pressure to 0 in that case, which means the capping is totally removed (issue reported by Steev)
- remove the check from patch 4/5 with
'throttled_freq > policy->cpuinfo.max_freq' since it doesn't have effect; instead relay on new arch_update_thermal_pressure() handling correctly such use case; this would also fix an issue in that original driver code, where the reduced capacity was calculated wrongly due to 'policy->cpuinfo.max_freq' used as a divider
- adjusted comments stressing the fact that the boost frequencies are supported
v3 [3]:
- added warning and check if provided capped frequency is lower than max (Viresh)
- removed check for empty cpu mask (Viresh)
- replaced tabs with spaces in the doxygen comment (Viresh)
- renamed {arch|topology}_thermal_pressure_update() to {arch|topology}_update_thermal_pressure() so it's align with scheme (Dietmar)
- added info about MHz in freq_factor into patch description (Dietmar) v2 [2]:
- added Reviewed-by from Thara for patch 3/5
- changed the doxygen comment and used mult_frac()
according to Thara's suggestion in patch 1/5
v1 -> [1]
Patches in v4 Applied
| # | Subject and files | Size | Replies | Applied |
|---|---|---|---|---|
| 1/5 | arch_topology: Introduce thermal pressure update functionarch/ arch/ drivers/ +2 more | +54 | 2 replies | |
| 2/5 | thermal: cpufreq_cooling: Use new thermal pressure update functiondrivers/ | +1 | 0 replies | |
| 3/5 | cpufreq: qcom-cpufreq-hw: Update offline CPUs per-cpu thermal pressuredrivers/ | +2 | 0 replies | |
| 4/5 | cpufreq: qcom-cpufreq-hw: Use new thermal pressure update functiondrivers/ | +3 | 4 replies | |
| 5/5 | arch_topology: Remove unused topology_set_thermal_pressure() and relatedarch/ arch/ drivers/ +3 more | +6 | 0 replies |
Reviews trailers per patch
3 of 5 patches have a Reviewed-by or Acked-by.
| Patch | Thara Gopinath |
|---|---|
| 1/5 | R-b |
| 2/5 | |
| 3/5 | R-b |
| 4/5 | R-b |
| 5/5 |
Trailers given in replies are filled; those carried in the patches from earlier versions are outlined with dashes.
Cover letter [PATCH v4 0/5] Refactor thermal pressure update to avoid code duplication
Hi all,
This patch set v4 aims to refactor the thermal pressure update code. There are already two clients which do similar thing:
convert the capped frequency value into the capacity of affected CPU and call the 'set' function to store the reduced capacity into the per-cpu variable.
There might be more than two of these users. In near future it will be scmi-cpufreq driver, which receives notification from FW about reduced frequency due to thermal. Other vendors might follow. Let's avoid code duplication and potential conversion bugs. Move the conversion code into the arch_topology.c where the capacity calculation setup code and thermal pressure sit.
Apart from that $subject patches, there is one patch (3/5) which fixes issue in qcom-cpufreq-hw.c when the thermal pressure is not updated for offline CPUs. It's similar fix that has been merged recently for cpufreq_cooling.c:2ad8ccc17d1e4270cf65a3f2
The patch 4/5 fixes also qcom-cpufreq-hw.c driver code which did the translation from frequency to capacity wrongly when there was a boost frequency available and stored in 'policy->cpuinfo.max_freq'.
Changes:
v4:
- remove the warning when boost frequency is passed and set thermal pressure to 0 in that case, which means the capping is totally removed (issue reported by Steev)
- remove the check from patch 4/5 with
'throttled_freq > policy->cpuinfo.max_freq' since it doesn't have effect; instead relay on new arch_update_thermal_pressure() handling correctly such use case; this would also fix an issue in that original driver code, where the reduced capacity was calculated wrongly due to 'policy->cpuinfo.max_freq' used as a divider
- adjusted comments stressing the fact that the boost frequencies are supported
v3 [3]:
- added warning and check if provided capped frequency is lower than max (Viresh)
- removed check for empty cpu mask (Viresh)
- replaced tabs with spaces in the doxygen comment (Viresh)
- renamed {arch|topology}_thermal_pressure_update() to {arch|topology}_update_thermal_pressure() so it's align with scheme (Dietmar)
- added info about MHz in freq_factor into patch description (Dietmar) v2 [2]:
- added Reviewed-by from Thara for patch 3/5
- changed the doxygen comment and used mult_frac()
according to Thara's suggestion in patch 1/5
v1 -> [1]
Regards,
Lukasz Luba
[1] https://lore.kernel.org/linux-pm/[email protected]/
[2] https://lore.kernel.org/linux-pm/[email protected]/
[3] https://lore.kernel.org/linux-pm/[email protected]/
Lukasz Luba (5):
arch_topology: Introduce thermal pressure update function
thermal: cpufreq_cooling: Use new thermal pressure update function
cpufreq: qcom-cpufreq-hw: Update offline CPUs per-cpu thermal pressure
cpufreq: qcom-cpufreq-hw: Use new thermal pressure update function
arch_topology: Remove unused topology_set_thermal_pressure() and
related
arch/arm/include/asm/topology.h | 2 +- arch/arm64/include/asm/topology.h | 2 +- drivers/base/arch_topology.c | 42 ++++++++++++++++++++++++++++--- drivers/cpufreq/qcom-cpufreq-hw.c | 14 +++-------- drivers/thermal/cpufreq_cooling.c | 6 +---- include/linux/arch_topology.h | 4 +-- include/linux/sched/topology.h | 6 ++--- init/Kconfig | 2 +- 8 files changed, 50 insertions(+), 28 deletions(-)