Changes in v2 from the cover letter
- Fix dt binding document
Patches in v2 No applies recorded yet
| # | Subject and files | Size | Replies | Applied |
|---|---|---|---|---|
| 1/2 | dt-bindings: iio: humidity: Add si7020 bindingsDocumentation/ Documentation/ | +47 | 4 replies | |
| 2/2 | iio: humidity: si7020: Check device property for skipping reset in probedrivers/ | +8 | 0 replies |
Reviews trailers per patch
No Reviewed-by, Acked-by or Tested-by trailers for v2 yet.
Cover letter [PATCH v2 0/2] iio: humidity: si7020: Check device property for skipping reset in probe
I2C commands issued after the SI7020 is starting up or after reset can potentially upset the startup sequence. Therefore, the host needs to wait for the startup sequence to finish before issuing further i2c commands. This is impractical in cases where the SI7020 is on a shared bus or behind a mux, which may switch channels at any time (generating I2C traffic). Therefore, check for a device property that indicates that the driver should skip resetting the device when probing.
Changes since v1:
- Fix dt binding document
Eddie James (2):
dt-bindings: iio: humidity: Add si7020 bindings
iio: humidity: si7020: Check device property for skipping reset in probe
.../bindings/iio/humidity/silabs,si7020.yaml | 47 +++++++++++++++++++ .../devicetree/bindings/trivial-devices.yaml | 2 - drivers/iio/humidity/si7020.c | 14 +++--- 3 files changed, 55 insertions(+), 8 deletions(-) create mode 100644 Documentation/devicetree/bindings/iio/humidity/silabs,si7020.yaml