hwmon: (aquacomputer_d5next) Add Aquacomputer Aquaero control
Status from this message: Applied. In the future, please make sure that the line length in the
Get series with b4
b4 am [email protected]Versions newest first · linked by author and title
- v2 Latest6 patches 6 repliesApplied
- v15 patches 7 repliesSuperseded
Changes in v2 from the cover letter
- split original patch 3 into three patches to have one logical change each
- explain why Aquaero does not need the checksum
- improve wording of documentation
- drop last patch with pwmX_mode
Patches in v2 Applied
| # | Subject and files | Size | Replies | Applied |
|---|---|---|---|---|
| 1/6 | hwmon: (aquacomputer_d5next) Support one byte control valuesdrivers/ | +38 | 1 reply | |
| 2/6 | hwmon: (aquacomputer_d5next) Support writing multiple control values at oncedrivers/ | +18 | 1 reply | |
| 3/6 | hwmon: (aquacomputer_d5next) Device dependent control report settingsdrivers/ | +14 | 1 reply | |
| 4/6 | hwmon: (aquacomputer_d5next) Add infrastructure for Aquaero control reportsdrivers/ | +26 | 1 reply | |
| 5/6 | hwmon: (aquacomputer_d5next) Add temperature offset control for AquaeroDocumentation/ drivers/ | +10 | 1 reply | |
| 6/6 | hwmon: (aquacomputer_d5next) Add fan PWM control for AquaeroDocumentation/ drivers/ | +60 | 1 reply |
Reviews trailers per patch
No Reviewed-by, Acked-by or Tested-by trailers for v2 yet.
Cover letter [PATCH v2 0/6] hwmon: (aquacomputer_d5next) Add Aquacomputer Aquaero control
Add support for controlling the Aquacomputer Aquaero 5/6 fan controllers. The controllable settings include temperature offsets and fan PWM.
The first four patches expand the capabilities of the control system without changing functionality. Patches 4-6 add support for Aquaero control.
changelog:
v2:
- split original patch 3 into three patches to have one logical change each
- explain why Aquaero does not need the checksum
- improve wording of documentation
- drop last patch with pwmX_mode
Leonard Anderweit (6):
hwmon: (aquacomputer_d5next) Support one byte control values
hwmon: (aquacomputer_d5next) Support writing multiple control values
at once
hwmon: (aquacomputer_d5next) Device dependent control report settings
hwmon: (aquacomputer_d5next) Add infrastructure for Aquaero control
reports
hwmon: (aquacomputer_d5next) Add temperature offset control for
Aquaero
hwmon: (aquacomputer_d5next) Add fan PWM control for Aquaero
Documentation/hwmon/aquacomputer_d5next.rst | 5 +- drivers/hwmon/aquacomputer_d5next.c | 182 ++++++++++++++++---- 2 files changed, 155 insertions(+), 32 deletions(-)