Hi,
Following up to https://lore.kernel.org/all/[email protected]/ and https://lore.kernel.org/all/[email protected]/ I experimented with the thermal subsystem and these are my results so far, but I'm hitting a bit of a wall:
As far as I can tell to implement "2. As long as GTMP is > 80°C fan speed must be at least 30%." I would need to add a new gevenor, lets call it "user_space_with_safeguards". I would be nice when the temp <-> fanspeed relation could be passed via the thermal_trip structure. And safeguarding the hardware from userspace only works when I can restrict userspace from just selecting the preexisting "user_space" govenor.
So my ideas/questions:
- Add a field "min_fanspeed_percent" to the thermal_trip struct that will only be used by the "user_space_with_safeguards" govenor
- Add a "user_space_with_safeguards" govenor that is the same as the "user_space" govenor, but on trip, a minimum speed is applied
- How can i ensure that on further speed updates the min speed is applied to? I could just implement it directly in the cdev, but that would be spagetti coding around the govenor.
- Can I somehow restrict userspace from using certain govenors?
- I'm a litte bit confused about the thermal zone "mode" sysfs switch, here it says deactivate for userspace control: https://elixir.bootlin.com/linux/v6.12/source/Documentation/ABI/testing/sysfs-class-thermal#L20, but what about the user_space govenor then?
Best regards,
Werner
Werner Sembach (1):
platform: x86: tuxi: Implement TUXEDO TUXI ACPI TFAN as thermal
subsystem
drivers/platform/x86/Makefile | 3 + drivers/platform/x86/tuxedo/Kbuild | 6 + drivers/platform/x86/tuxedo/nbxx/Kbuild | 8 + drivers/platform/x86/tuxedo/nbxx/Kconfig | 9 + drivers/platform/x86/tuxedo/nbxx/acpi_tuxi.c | 96 +++++++ drivers/platform/x86/tuxedo/nbxx/acpi_tuxi.h | 84 ++++++ .../x86/tuxedo/nbxx/acpi_tuxi_thermal.c | 241 ++++++++++++++++++ .../x86/tuxedo/nbxx/acpi_tuxi_thermal.h | 14 + 8 files changed, 461 insertions(+) create mode 100644 drivers/platform/x86/tuxedo/Kbuild create mode 100644 drivers/platform/x86/tuxedo/nbxx/Kbuild create mode 100644 drivers/platform/x86/tuxedo/nbxx/Kconfig create mode 100644 drivers/platform/x86/tuxedo/nbxx/acpi_tuxi.c create mode 100644 drivers/platform/x86/tuxedo/nbxx/acpi_tuxi.h create mode 100644 drivers/platform/x86/tuxedo/nbxx/acpi_tuxi_thermal.c create mode 100644 drivers/platform/x86/tuxedo/nbxx/acpi_tuxi_thermal.h