hwmon: (tmp513) Fix interpretation of values of TMP513 registers
Status from this message: Applied, after fixing checkpatch complaints.
Get series with b4
b4 am [email protected]Versions newest first
Patches in v1 Applied
| # | Subject and files | Size | Replies | Applied |
|---|---|---|---|---|
| 1/3 | hwmon: (tmp513) Fix interpretation of values of Shunt Voltage and Limit Registersdrivers/ | +4 | 1 reply | |
| 2/3 | hwmon: (tmp513) Fix Current Register value interpretationdrivers/ | +1 | 1 reply | |
| 3/3 | hwmon: (tmp513) Fix interpretation of values of Temperature Result and Limit Registersdrivers/ | +1 | 0 replies |
Reviews trailers per patch
No Reviewed-by, Acked-by or Tested-by trailers for v1 yet.
Cover letter [PATCH 0/3] hwmon: (tmp513) Fix interpretation of values of TMP513 registers
The function tmp51x_get_value returns processed values of the TMP513 device registers. Raw register values are converted to signed integer values by sign extension in accordance with the algorithm provided in the specification, but due to the off-by-one error in the sign bit index, the result is incorrect. There are also some other mistakes, such as incorrect cast.
Changes introduced by these patches are based on the TMP512/TMP513 datasheets that are specified in Documentation/hwmon/tmp513.rst. They have not actually been tested in any real or virtual environment. However the calculations have been tested separately to make sure they work as expected.
Found by Linux Verification Center (linuxtesting.org) with SVACE.
Murad Masimov (3):
hwmon: (tmp513) Fix interpretation of values of Shunt Voltage and
Limit Registers
hwmon: (tmp513) Fix Current Register value interpretation
hwmon: (tmp513) Fix interpretation of values of Temperature Result and
Limit Registers
drivers/hwmon/tmp513.c | 10 ++++++---- 1 file changed, 6 insertions(+), 4 deletions(-)
--
2.39.2