qcom: Add FIT capsule support with multi-partition updates
Get series with b4
b4 am [email protected] change-id 20260522-capsule-90a61c84ffb8Versions newest first
- v1 Latest7 patches 37 repliesIn review
Patches in v1 No applies recorded yet
| # | Subject and files | Size | Replies | Applied |
|---|---|---|---|---|
| 1/7 | qcom: capsule: add FIT capsule support with multi-partitionarch/ arch/ | +712 | 34 replies | |
| 2/7 | efi_loader: firmware: track last attempt status for ESRT reportinglib/ | +118 | 0 replies | |
| 3/7 | efi_loader: firmware: add last attempt tracking for RAW capsuleslib/ | +30 | 0 replies | |
| 4/7 | efi_loader: Extract FW version even on authentication failurelib/ | +10 | 0 replies | |
| 5/7 | configs: qcom: enable FIT capsule support by defaultconfigs/ | +1 | 3 replies | |
| 6/7 | tools: add fvupdate_to_fit.py for FIT capsule generationtools/ | +605 | 0 replies | |
| 7/7 | doc: add fvupdate_to_fit.py documentation and example XMLdoc/ doc/ | +530 | 0 replies |
Reviews trailers per patch
No Reviewed-by, Acked-by or Tested-by trailers for v1 yet.
Cover letter [PATCH 0/7] qcom: Add FIT capsule support with multi-partition updates
This patch series introduces FIT-based capsule updates alongside the existing RAW capsule implementation, enabling atomic multi-partition firmware updates. The implementation automatically discovers all partitions across SCSI/UFS and eMMC devices, applies A/B slot selection based on GPT vendor attributes, and generates a single ESRT entry representing all partitions for simplified management.
The series also improves ESRT reporting by tracking last attempt status for both FIT and RAW capsules.
Patch 1 adds the core FIT capsule infrastructure with comprehensive partition discovery, A/B selection logic, and multi-partition DFU string generation for both UFS and eMMC storage.
Patch 2 implements last attempt status tracking for FIT capsules, enabling proper ESRT reporting with version and status information.
Patch 3 extends last attempt tracking to RAW capsules for consistent ESRT behavior across both capsule types.
Patch 4 ensures firmware version extraction even when capsule authentication fails, improving error reporting accuracy.
Patch 5 switches the default Qualcomm configuration from RAW to FIT capsule support.
Patch 6 provides fvupdate_to_fit.py, a Python tool for end-to-end conversion from XML files to deployable capsules,
with support for board-specific GUIDs, versioning, and signing.
Patch 7 adds comprehensive documentation and example XML files for the conversion tool.
---
Balaji Selvanathan (7):
qcom: capsule: add FIT capsule support with multi-partition
efi_loader: firmware: track last attempt status for ESRT reporting
efi_loader: firmware: add last attempt tracking for RAW capsules
efi_loader: Extract FW version even on authentication failure
configs: qcom: enable FIT capsule support by default
tools: add fvupdate_to_fit.py for FIT capsule generation
doc: add fvupdate_to_fit.py documentation and example XML
arch/arm/mach-snapdragon/capsule_update.c | 740 +++++++++++++++++++++-- arch/arm/mach-snapdragon/qcom-priv.h | 23 + configs/qcom_defconfig | 2 +- doc/develop/fvupdate_to_fit.rst | 487 +++++++++++++++ doc/develop/fvupdate_to_fit/example_FvUpdate.xml | 43 ++ lib/efi_loader/efi_firmware.c | 176 +++++- tools/fvupdate_to_fit.py | 605 ++++++++++++++++++ 7 files changed, 2006 insertions(+), 70 deletions(-)
---
base-commit: 744cf5d4e398c5f657e5c3eeb44d00fa5175dc85
change-id: 20260522-capsule-90a61c84ffb8
Best regards,
Signature · 1 line