RFC media: uvcvideo: reset interface on bulk stream stop
Get series with b4
b4 am [email protected]Versions newest first
- v1 RFC Latest1 patch 7 repliesIn review
Patches in v1 No applies recorded yet
| # | Subject and files | Size | Replies | Applied |
|---|---|---|---|---|
| 1/1 | media: uvcvideo: reset interface on bulk stream stopdrivers/ | +2 | 0 replies |
Reviews trailers per patch
No Reviewed-by, Acked-by or Tested-by trailers for v1 yet.
Cover letter [RFC PATCH 0/1] media: uvcvideo: reset interface on bulk stream stop
Hi,
I would like to revive an old UVC bulk-streaming issue originally reported by Hans Yang. I am sending this RFC on his behalf for discussion before submitting a non-RFC patch.
Hans previously proposed making uvcvideo call usb_set_interface(..., 0) when stopping a bulk-based stream, before clearing halt on the bulk endpoint. The issue was discussed here:
https://www.spinics.net/lists/linux-usb/msg171584.html
The current upstream stop path calls usb_set_interface(..., 0) only when the streaming interface has more than one alternate setting. For single-altsetting bulk devices, uvcvideo only sends CLEAR_FEATURE(ENDPOINT_HALT) to the bulk endpoint.
The patch in this RFC changes uvc_video_stop_streaming() to always call usb_set_interface(..., 0) to reset the streaming interface first. For bulk devices, the existing CLEAR_FEATURE(ENDPOINT_HALT) request is still sent afterwards.
On the affected devices, current upstream stop/start sequence can leave the next bulk stream failing immediately with transfer errors such as:
uvcvideo: Non-zero status (-71) in video completion handler.
USB bus traces show that, without usb_set_interface(..., 0), the host continues the next bulk stream with the previous stream's sequence state, while the device expects the new stream to start from the initial sequence state. With usb_set_interface(..., 0), the host and device sequence states match again and repeated stop/start cycles complete successfully.
The affected devices we have seen include:
- ID 8086:0b07 Intel Corp. RealSense D435
- ID 2560:c1d0 e-con Systems See3CAM_CU130
- ID 2b03:f582 STEREOLABS ZED camera
I understand that the earlier discussion raised two important concerns:
1. Whether this should be fixed in uvcvideo or lower in the USB/xHCI stack, since CLEAR_FEATURE(ENDPOINT_HALT) should normally reset the endpoint halt condition and data toggle/sequence state.
2. Whether calling usb_set_interface(..., 0) for single-altsetting bulk UVC devices could regress existing devices.
For the first point, my understanding is that the kernel helper usb_set_interface(..., 0) issues SET_INTERFACE and lets the USB core reinitialize the endpoints for the selected alternate setting, including their data toggle/sequence state. The traces suggest that, in this stop/start path, CLEAR_FEATURE(ENDPOINT_HALT) alone is not enough to make the host and device restart the next bulk stream from the same sequence state. The additional usb_set_interface(..., 0) call makes repeated stop/start cycles reliable on the affected hardware.
For the second point, I can provide before/after test results from the affected hardware listed above. I can also test a quirk-based version if that would be preferred over changing the generic bulk-stream stop path.
I would appreciate guidance on whether this one-patch RFC is the preferred direction, or whether upstream would prefer a UVC quirk-based change for the affected devices listed above.
Thanks,
Henry