net: pse-pd: Add LTC4266 PSE controller driver
Get series with b4
b4 am [email protected]Versions newest first · linked by author and title
- v3 Latest2 patches 8 repliesIn review
- v2 RFC2 patches 4 repliesSuperseded
Changes in v3 from the cover letter
- The admin power limit is now configurable before the port is powered and is independent from the class limit. However, when a PD is powered, the current limit is set by the minimum between the PD's class and the admin power limit, to maintain compliance with the IEEE spec.
- The LTC4266 doesn't support reading a port's voltage (or current) until that port is completely and successfully powered. Since we don't have a good way to measure the port voltage, we'll first try to use the vpwr-supply voltage if available during probe, and fall back to 50V (the Type 2 PSE minimum) if the regulator isn't available (ENODEV or EPROBE_DEFER) or doesn't have a readable voltage for the port. This is the voltage the LTC4266 driver will return back to pse core when a port's power good bit is not set.
- Report the hardware admin state from the "Power Enabled" bit instead of the "Power Good" bit. The latter is set when the port is fully powered (after inrush) so a port in the process of powering up looked disabled to the core and had power domain budget allocated to it twice.
- Added a Maintainers entry for the driver.
- Avoid precision loss in pi_get_actual_pw.
- Demote a dev_err in a common path on device disconnection to dev_dbg.
- Add an err: label in map_event that'll clear all the event registers via the INTCLR push-button to prevent a possible interrupt storm.
- The supply and over-temperature faults were too hard to test, but they will result in a disconnection event for one or more channels. Replace those faults with a combination of a "power good" change and a port status check to send a disconnect event to the pse core.
- Bail out of probe early if we don't have the required IRQ.
- Replace the driver's .remove with a devm action registered before the controller and the IRQ to ensure the IRQ is freed before this driver is removed.
- Drop reset-gpios from the binding, since the driver doesn't support it at the moment (because my hardware doesn't have it correctly wired)
- Expand the description for sense-resistor-micro-ohms to indicate the property is required by the chip for accurate current limiting.
Patches in v3 No applies recorded yet
| # | Subject and files | Size | Replies | Applied |
|---|---|---|---|---|
| 1/2 | dt-bindings: net: pse-pd: Add bindings for LTC4266 PSE ControllerDocumentation/ | +180 | 5 replies | |
| 2/2 | net: pse-pd: Add LTC4266 PSE controller driverMAINTAINERS drivers/ drivers/ +1 more | +1405 | 3 replies |
Reviews trailers per patch
No Reviewed-by, Acked-by or Tested-by trailers for v3 yet.
Cover letter [PATCH net-next v3 0/2] net: pse-pd: Add LTC4266 PSE controller driver
Add support for an older PSE controller that supports powering Type 1 and Type 2 PDs.
The chip has four individually controllable power channels, each with it own detection, classification and current-limiting abilities. The driver declares the static power budgeting strategy.
---
RFC v2 -> v3:
- The admin power limit is now configurable before the port is powered and is independent from the class limit. However, when a PD is powered, the current limit is set by the minimum between the PD's class and the admin power limit, to maintain compliance with the IEEE spec.
- The LTC4266 doesn't support reading a port's voltage (or current) until that port is completely and successfully powered. Since we don't have a good way to measure the port voltage, we'll first try to use the vpwr-supply voltage if available during probe, and fall back to 50V (the Type 2 PSE minimum) if the regulator isn't available (ENODEV or EPROBE_DEFER) or doesn't have a readable voltage for the port. This is the voltage the LTC4266 driver will return back to pse core when a port's power good bit is not set.
- Report the hardware admin state from the "Power Enabled" bit instead of the "Power Good" bit. The latter is set when the port is fully powered (after inrush) so a port in the process of powering up looked disabled to the core and had power domain budget allocated to it twice.
- Added a Maintainers entry for the driver.
- Avoid precision loss in pi_get_actual_pw.
- Demote a dev_err in a common path on device disconnection to dev_dbg.
- Add an err: label in map_event that'll clear all the event registers via the INTCLR push-button to prevent a possible interrupt storm.
- The supply and over-temperature faults were too hard to test, but they will result in a disconnection event for one or more channels. Replace those faults with a combination of a "power good" change and a port status check to send a disconnect event to the pse core.
- Bail out of probe early if we don't have the required IRQ.
- Replace the driver's .remove with a devm action registered before the controller and the IRQ to ensure the IRQ is freed before this driver is removed.
- Drop reset-gpios from the binding, since the driver doesn't support it at the moment (because my hardware doesn't have it correctly wired)
- Expand the description for sense-resistor-micro-ohms to indicate the property is required by the chip for accurate current limiting.
Link to RFC v2: https://lore.kernel.org/all/[email protected]/
Kyle Swenson (2):
dt-bindings: net: pse-pd: Add bindings for LTC4266 PSE Controller
net: pse-pd: Add LTC4266 PSE controller driver
.../bindings/net/pse-pd/lltc,ltc4266.yaml | 180 +++ MAINTAINERS | 7 + drivers/net/pse-pd/Kconfig | 11 + drivers/net/pse-pd/Makefile | 1 + drivers/net/pse-pd/ltc4266.c | 1386 +++++++++++++++++ 5 files changed, 1585 insertions(+) create mode 100644 Documentation/devicetree/bindings/net/pse-pd/lltc,ltc4266.yaml create mode 100644 drivers/net/pse-pd/ltc4266.c
Signature · 1 line
2.55.0